Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FINS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

ORBITS OF SUBSYSTEMS IN FOUR HIERARCHICAL MULTIPLE STARS

Seven spectroscopic orbits in nearby solar-type multiple stars are presented. The primary of the chromospherically active star HIP 9642 is a 4.8 day double-lined pair; the outer 420 year visual orbit is updated, but remains poorly constrained. HIP 12780 is a quadruple system consisting of the resolved 6.7 year pair FIN 379 Aa,Ab, for which the combined orbit, masses, and orbital parallax are determined here, and the single-lined binary Ba,Bb with a period of 27.8 days. HIP 28790 is a young quintuple system composed of two close binaries, Aa,Ab and Ba,Bb, with periods of 221 and 13 days, respectively, and a single distant component C. Its subsystem Ba,Bb is peculiar, having a spectroscopic mass ratio of 0.89 but a magnitude difference of ∼2.2 mag. HIP 64478 also contains five stars: the A-component is a 29 year visual pair with a previously known 4 day twin subsystem, while the B-component is a contact binary with a period of 5.8 hr, seen nearly pole-on.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparative Evaluation of Four Presumptive Tests for Blood to Detect Epithelial Injury on Fish

Current methods of fish epithelial injury detection are limited to gross macroscopic examination that has a subjective bias as well as an inability to reliably quantify the degree of injury. Fluorescein, a presumptive test for blood, has been shown to have the capability to detect and quantify fish epithelial injury. However, there are several other presumptive tests for blood (Bluestar*, phenolphthalein, and HemastixH) that may have benefits over the use of fluorescein, particularly for field research on wild fish. This study investigated the capabilities of these four tests to detect and quantify a variety of injuries commonly encountered by fish (abrasion, cuts, fin frays, and punctures) using the freshwater bluegill Lepomis macrochirus as a model. Fluorescein was consistently found to be the most reliable (i.e., detected the highest proportion of true positive results and rarely detected false positive reactions) of the four presumptive tests for blood compared. Further testing was conducted to examine the reliability of fluorescein. By 24 h after an injury was inflicted, the injury was no longer detectable by fluorescein, and when fluorescein was applied to an injured fish, the fluorescein was no longer detectable 3 h after application. In a comparison of two common anaesthetics used in fisheries research, there was no significant difference in the proportion of injury detected when 3- aminobenzoic acid ethyl ester methanesulfate (tricaine) was used compared with a clove oil and ethanol (1:9) solution. In summary, fluorescein was the most reliable presumptive test for blood examined in this study for the detection and quantification of recent (hours) fish epithelial injury.

Fluorescein, fish, epithelial damage↗

A new method for operating a continuous-flow diffusion chamber to investigate immersion freezing: assessment and performance study

Abstract. Glaciation in mixed-phase clouds predominantly occurs through the immersion-freezing mode where ice-nucleating particles (INPs) immersed within supercooled droplets induce the nucleation of ice. Model representations of this process currently are a large source of uncertainty in simulating cloud radiative properties, so to constrain these estimates, continuous-flow diffusion chamber (CFDC)-style INP devices are commonly used to assess the immersion-freezing efficiencies of INPs. This study explored a new approach to operating such an ice chamber that provides maximum activation of particles without droplet breakthrough and correction factor ambiguity to obtain high-quality INP measurements in a manner that previously had not been demonstrated to be possible. The conditioning section of the chamber was maintained at −20 ∘C and water relative humidity (RHw) conditions of 113 % to maximize the droplet activation, and the droplets were supercooled with an independently temperature-controlled nucleation section at a steady cooling rate (0.5 ∘C min−1) to induce the freezing of droplets and evaporation of unfrozen droplets. The performance of the modified compact ice chamber (MCIC) was evaluated using four INP species: K-feldspar, illite-NX, Argentinian soil dust, and airborne soil dusts from an arable region that had shown ice nucleation over a wide span of supercooled temperatures. Dry-dispersed and size-selected K-feldspar particles were generated in the laboratory. Illite-NX and soil dust particles were sampled during the second phase of the Fifth International Ice Nucleation Workshop (FIN-02) campaign, and airborne soil dust particles were sampled from an ambient aerosol inlet. The measured ice nucleation efficiencies of model aerosols that had a surface active site density (ns) metric were higher but mostly agreed within 1 order of magnitude compared to results reported in the literature.

54 ENVIRONMENTAL SCIENCES↗

A new method for operating a continuous flow diffusion chamber to investigate immersion freezing: assessment and performance study

Glaciation in mixed-phase clouds predominately occurs through the immersion freezing mode where ice nucleating particles (INPs) immersed within supercooled droplets induce nucleation of ice. Currently, model representations of this process are a large source of uncertainty in simulating cloud radiative properties, and to constrain these estimates, continuous flow diffusion chamber (CFDC)-style INP devices are commonly used to assess the immersion freezing efficiencies of INPs. In this study, a new approach was explored to operating such an ice chamber that provides maximum activation of particles without droplet breakthrough and correction factor ambiguity to obtain high-quality INP measurements in a manner that has not been demonstrated as possible previously. The conditioning section of the chamber was maintained at ~ –20 °C and water relative humidity (RH w ) ~ 113 % conditions to maximize the droplet activation, and the droplets were supercooled with an independently temperature-controlled nucleation section at a steady cooling rate (0.5 °C min –1 ) to induce the freezing of droplets and evaporation of unfrozen droplets. The performance of the modified ice chamber was evaluated using four INP species: K-feldspar, illite-NX, Argentinian soil dust, and airborne arable dust that had shown ice nucleation over a wide span of supercooled temperatures. Dry dispersed and size-selected K-feldspar particles were generated in the laboratory. Illite-NX and soil dust particles were sampled during the second phase of the Fifth International Ice Nucleation Workshop (FIN-02) campaign, and airborne arable dust particles were sampled from the aerosol inlet located on the rooftop of the laboratory. The measured ice nucleation efficiencies of model aerosols with a surface active site density (n s ) metric were higher, but mostly agreed within one order of magnitude compared to literature results.

54 ENVIRONMENTAL SCIENCES↗

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

Program computes zero lift wave drag of entire aircraft

Computer program computes zero lift wave drag of an entire aircraft including any combination of the wing, body, pods, fins, and carnard. The program computes the external volume of the wing and the axial area distribution of the wing equivalent body.

Craidon, C. B.↗