Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FACILITIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Adapting federated cyberinfrastructure for shared data collection facilities in structural biology

Early stage experimental data in structural biology is generally unmaintained and inaccessible to the public. It is increasingly believed that this data, which forms the basis for each macromolecular structure discovered by this field, must be archived and, in due course, published. Furthermore, the widespread use of shared scientific facilities such as synchrotron beamlines complicates the issue of data storage, access and movement, as does the increase of remote users. This work describes a prototype system that adapts existing federated cyberinfrastructure technology and techniques to significantly improve the operational environment for users and administrators of synchrotron data collection facilities used in structural biology. This is achieved through software from the Virtual Data Toolkit and Globus, bringing together federated users and facilities from the Stanford Synchrotron Radiation Lightsource, the Advanced Photon Source, the Open Science Grid, the SBGrid Consortium and Harvard Medical School. The performance and experience with the prototype provide a model for data management at shared scientific facilities.

59 BASIC BIOLOGICAL SCIENCES↗

Single Event Effects Test Facility Options at the Oak Ridge National Laboratory

Increasing use of microelectronics of ever diminishing feature size in avionics systems has led to a growing Single Event Effects (SEE) susceptibility arising from the highly ionizing interactions of cosmic rays and solar particles. Single event effects caused by atmospheric radiation have been recognized in recent years as a design issue for avionics equipment and systems. To ensure a system meets all its safety and reliability requirements, SEE induced upsets and potential system failures need to be considered, including testing of the components and systems in a neutron beam. Testing of integrated circuits (ICs) and systems for use in radiation environments requires the utilization of highly advanced laboratory facilities that can run evaluations on microcircuits for the effects of radiation. This paper provides a background of the atmospheric radiation phenomenon and the resulting single event effects, including single event upset (SEU) and latch up conditions. A study investigating requirements for future single event effect irradiation test facilities and developing options at the Spallation Neutron Source (SNS) is summarized. The relatively new SNS—with its 1.0 GeV proton beam, typical operation of 5000 h per year, expertise in spallation neutron sources, user program infrastructure, and decades of useful life ahead—is well suited for hosting a world-class SEE test facility in North America. Emphasis was put on testing of large avionics systems while still providing tunable high flux irradiation conditions for component tests. Makers of ground-based systems would also be served well by these facilities. Three options are described; the most capable, flexible, and highest-test-capacity option is a new stand-alone target station using about one kW of proton beam power on a gas-cooled tungsten target, with dual test enclosures. Less expensive options are also described.

Digital avionics↗

Scalable Multi-Facility Workflows for Artificial Intelligence Applications in Climate Research

Earth observation satellites and earth system models are sources of vast, multi-modal datasets that are invaluable for advancing climate and environmental research. However, their scale and complexity pose significant challenges for processing and analysis. In this paper we discuss our experiences in developing and using a scientific research application using an automated multi-facility workflow that orchestrates data collection, preprocessing, artificial intelligence (AI) inferencing, and data movement across diverse computational resources, leveraging the Advanced Computing Ecosystem Testbed at the Oak Ridge Leadership Computing Facility (OLCF). We demonstrate that our workflow can be seamlessly integrated and orchestrated across research facilities managed by different federal agencies, thus allowing users to extract new scientific insights from climate datasets. The experimental results indicate that the multi-facility workflow significantly reduces processing time, enhances scalability, and maintains high efficiency across varying workloads. Notably, our workflow processes 12,000 high-resolution satellite images in just 44 seconds using 80 workers distributed across 10 nodes on the OLCF systems. Such high throughput is essential for dynamic tokenization and sharding of petascale satellite data for distributed AI model training and inferencing at scale across thousands of GPUs.

Kurihana, Takuya [ORNL] (ORCID:0000000156698565)↗

Status and Development of Pulsed Magnets at the NHMFL Pulsed Field Facility

The National High Magnetic Field Laboratory's Pulsed Field Facility at Los Alamos National Laboratory is one of few research centers in the world that can create and use ultrahigh pulsed magnetic field for scientific research. The facility houses several types of nondestructive pulsed magnets which can provide the peak fields ranging from 60 to 100 T for users. This study will report the status of the user magnets and recent magnet developments to improve the quality and magnetic fields of our user magnets. In particular, this paper will present a new cooling technique that significantly reduces the cooling time without affecting the mechanical performance of the magnets. A possible upgrade of our facility with a new duplex magnet that is powered by a 4-MJ capacitor bank to deliver 80 T for users will be also reported. Finally, in addition, we will discuss some valuable lessons learned from magnet failures at our facility and possible further magnet design improvements to increase the magnet longevity or peak magnetic fields.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design, Flow Field, and Heat Transfer Characterization of the Conjugate Aero-Thermal Test Facility at NETL

A new aerothermal test facility was constructed for the purpose of studying film cooling performance in an environment that accurately simulates conjugate heat transfer characteristics that exist in engine operation. Here, this paper details the design of the facility and the plan for conducting steady state film cooling experiments to improve the understanding of conjugate heat transfer scaling from laboratory to engine conditions. The test facility consists of two separate low channels (hot gas/coolant) and each gas path has a flow conditioning section, a convergent nozzle and a test section/channel with viewports. Numerical simulations were conducted to predict flow field characteristics supporting the design of the flow loop facility. Preliminary experiments were conducted to characterize the flow field using velocity and temperature profile measurements. In addition, infrared (IR) thermography methods were developed to measure surface temperatures on the hot side of the test plate. The IR measurement methods including calibration of the IR camera is explained in detail. It was concluded that appropriate hot gas path flow conditioning could be achieved using a strainer-like tube, a perforated plate, and a honeycomb-mesh screen system upstream of the test section. Flow field measurements from preliminary experiments showed that the boundary layer profile follows the law of the wall.

47 OTHER INSTRUMENTATION↗

Deconstructing laws of accessibility and facility distribution in cities

The era of the automobile has seriously degraded the quality of urban life through costly travel and visible environmental effects. A new urban planning paradigm must be at the heart of our road map for the years to come, the one where, within minutes, inhabitants can access their basic living needs by bike or by foot. In this work, we present novel insights of the interplay between the distributions of facilities and population that maximize accessibility over the existing road networks. Results in six cities reveal that travel costs could be reduced in half through redistributing facilities. In the optimal scenario, the average travel distance can be modeled as a functional form of the number of facilities and the population density. As an application of this finding, it is possible to estimate the number of facilities needed for reaching a desired average travel distance given the population distribution in a city.

42 ENGINEERING↗

Magnetic probe measurements of the current sheath on the PF-3 facility

Results are presented from experimental studies of the dynamics of the current sheath (CS) on the PF-3 plasma focus facility. The parameters of the sheath, including the current distribution in it, were measured using absolutely calibrated magnetic probes installed at different positions with respect to the facility axis and the anode surface. The CS dynamics in discharges operating in argon and neon was investigated, and the skin depth in different stages of the discharge was determined. One of the probes was installed at a distance of {approx}2 cm from the facility axis, which made it possible to estimate the efficiency of current transfer to the region of pinch formation. Operating modes were obtained in which the current dynamics detected by magnetic probes at different distances from the axis agreed well with the dynamics of the total discharge current until the instant of singularity in the current time derivative. It is shown that shunting breakdowns can lead to the formation of closed current loops. The shunting of the discharge current by the residual plasma is directly related to the efficiency of snowplowing of the working gas by the CS as it propagates from the insulator toward the facility axis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of energy release zones arising due to current losses in the convolution region of the magnetically insulated transmission lines of the ANGARA-5-1 facility

Among the factors limiting electromagnetic pulse transmission to the load in high-power electro-physical facilities, current losses in magnetically insulated transmission lines (MITLs) are of significant importance. One of such facilities is ANGARA-5-1—a multimodule facility with an output electric power of up to 6 TW. A fairly complicated configuration of the magnetic field in the convolution region of several MITLs makes it difficult to fix the places of current losses there. In this work, these places were determined by detecting the positions of IR sources in the convolution region of the MITLs of the ANGARA-5-1 facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

xGFabric: Coupling Sensor Networks and HPC Facilities with Private 5G Wireless Networks for Real-Time Digital Agriculture

Advanced scientific applications require coupling distributed sensor networks with centralized high-performance computing facilities. Citrus Under Protective Screening (CUPS) exemplifies this need in digital agriculture, where citrus research facilities are instrumented with numerous sensors monitoring environmental conditions and detecting protective screening damage. CUPS demands access to computational fluid dynamics codes for modeling environmental conditions and guiding real-time interventions like water application or robotic repairs. These computing domains have contrasting properties: sensor networks provide low-performance, limited-capacity, unreliable data access, while high-performance facilities offer enormous computing power through high-latency batch processing. Private 5G networks present novel capabilities addressing this challenge by providing low latency, high throughput, and reliability necessary for near-real-time coupling of edge sensor networks with HPC simulations. This work presents xGFabric, an end-to-end system coupling sensor networks with HPC facilities through Private 5G networks. The prototype connects remote sensors via 5G network slicing to HPC systems, enabling real-time digital agriculture simulation.

Digital Agriculture↗

The Rise of US Photovoltaics: An Exploration of Land Use Density Trends in Large‐Scale Solar Facility Attributes, 2012–2021

An energy transition is underway in the United States; renewable energy generation is now on par with coal and nuclear generation. The number of large-scale solar photovoltaic facilities increased approximately tenfold between 2012 and 2021, with an associated 25-fold increase in cumulative installed capacity. With ambitious decarbonization and renewable energy deployment goals at both the federal and state levels, deployments of large-scale solar photovoltaic facilities will continue apace. This growth is likely to be complex with ripples of impacts felt throughout different aspects of society, and thus accurate solar land use metrics allowing more accurate predictions are of value to policymakers, planners, and other stakeholders in the future photovoltaic build-out. In this paper, we leverage data from the newly released US Large-Scale Solar Photovoltaic Database to examine recent trends in large-scale solar photovoltaic land use. We analyze the relationships between solar array capacity density (W/acre) and a range of facility attributes to better understand the future land requirements of solar capacity expansion over the coming years. Installed capacity was the single strongest determinant of solar array area. However, we found substantial variation in capacity density across facility attributes, including mount type, latitude, urbanicity, time, and prior land use.

14 SOLAR ENERGY↗

Globus service enhancements for exascale applications and facilities

Many extreme-scale applications require the movement of large quantities of data to, from, and among leadership computing facilities, as well as other scientific facilities and the home institutions of facility users. These applications, particularly when leadership computing facilities are involved, can touch upon edge cases (e.g., terabyte files) that had not been a focus of previous Globus optimization work, which had emphasized rather the movement of many smaller (megabyte to gigabyte) files. We report here on how automated client-driven chunking can be used to accelerate both the movement of large files and the integrity checking operations that have proven to be essential for large data transfers. In conclusion, we present detailed performance studies that provide insights into the benefits of these modifications in a range of file transfer scenarios.

97 MATHEMATICS AND COMPUTING↗

Evaluation of Cooling Conditions for a High Heat Flux Testing Facility Based on Plasma-Arc Lamps

The new Irradiated Material Target Station (IMTS) facility for fusion materials at Oak Ridge National Laboratory (ORNL) uses an infrared plasma-arc lamp (PAL) to deliver incident heat fluxes as high as 27 MW/m 2 . The facility is being used to test irradiated plasma-facing component materials as part of the joint US-Japan PHENIX program. The irradiated samples are to be mounted on molybdenum sample holders attached to a water-cooled copper rod. Depending on the size and geometry of samples, several sample holders and copper rod configurations have been fabricated and tested. As a part of the effort to design sample holders compatible with the high heat flux (HHF) testing to be conducted at the IMTS facility, numerical simulations have been performed for two different water-cooled sample holder designs using the ANSYS FLUENT 14.0 commercial computational fluid dynamics (CFD) software package. The primary objective of this work is to evaluate the cooling capability of different sample holder designs, i.e. to estimate their maximum allowable incident heat flux values. 2D axisymmetric numerical simulations are performed using the realizable k-ε turbulence model and the RPI nucleate boiling model within ANSYS FLUENT 14.0. The results of the numerical model were compared against the experimental data for two sample holder designs tested in the IMTS facility. The model has been used to parametrically evaluate the effect of various operational parameters on the predicted temperature distributions. The results were used to identify the limiting parameter for safe operation of the two sample holders and the associated peak heat flux limits. The results of this investigation will help guide the development of new sample holder designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Cable Aging Acceptance Criteria for Nuclear Facilities

The aging of nuclear power plant electrical cables has been the subject of substantial research and development (R&D) projects in the nuclear industry, national and international laboratories, universities, and vendor organizations for several years. More specifically, these R&D efforts were conducted to develop equipment and techniques for assessing age-related degradation of in-service cables in nuclear facilities including power plants, research reactors, waste facilities and fuel fabrication plants. In recent years, cable R&D efforts in the nuclear arena have also included work to develop new cables for the next generation of reactors. Over time, exposure to harsh environmental conditions such as elevated temperatures, radiation, and humidity in nuclear installations can result in age-related degradation and failure of cables. In the current fleet of nuclear reactors, there are thousands of miles of cabling installed in each plant and many of these cables are exposed to these harsh environmental conditions. For these cables, the jacket and insulation polymers harden and become brittle over time, making them more susceptible to crack formation and growth, moisture intrusion, and other mechanisms that can lead to cable failure. Moreover, the existing U.S. fleet of 98 nuclear reactors has an average operating age of 38 years. Many of these nuclear power plants have applied for and almost all have been granted regulatory approval for license renewals to operate for 60 years, 20 years beyond their original 40-year life. Further, subsequent license renewals (SLRs) are underway with a few commercial nuclear power sites already approved to operate up to 80 years. As these reactors pursue operating life extensions, utilities must find a way to address issues associated with age-related degradation of cables. Designers of small modular reactors are also in need of technologies to evaluate the performance of cables that will be installed in harsher environments (e.g. higher temperatures, radiation doses, dose rates, etc.) than those present in current-generation reactors. Today, a variety of cable condition monitoring (CM) techniques have been developed and successfully used in nuclear facilities. These techniques are used to identify age-related degradation and assess the condition of cables to determine if their performance characteristics have changed with age. However, objective criteria must be developed for these CM tests to help quantify cable condition and thereby develop repair and replacement schedules. With operating life extending to 80 years and more SLRs on the horizon, both nuclear facilities and regulators need an objective means to determine the aged condition of cables.

36 MATERIALS SCIENCE↗

U.S. Freight Transload Facilities Dataset

The U.S. Freight Transload Facilities Dataset provides location information (latitude, longitude, zip, city, county, state)for more than 9,000 facilities across 50 U.S. States where freight may be transferred between waterways, railways, and roadways. The dataset lists the known modes and available direction(s) for freight transfers at each facility as of 2024. The U.S. Freight Transload Facilities dataset was built by mining and fusing several public sources, such as the USACE Master Docks Plus, the USDOT National Transportation Atlas Database (NTAD), files from the Intermodal Association of North America (IANA), and the industry publication Bulk Transloader. The dataset constitutes a key piece of a multimodal freight transportation network and routing algorithm developed by USACE-ERDC. The dataset is shared as a .csv file. The dataset is published for research purposes and should not be considered exhaustive or authoritative.

Peterson, Steven [ORNL] (ORCID:0000000287672998)↗

2010 Annual Wastewater Reuse Report for the Idaho National Laboratory Site's Central Facilities Area Sewage Treatment Plant

This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (#LA-000141-03), for the wastewater land application site at Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant from November 1, 2009, through October 31, 2010. The report contains the following information: • Site description • Facility and system description • Permit required monitoring data and loading rates • Status of special compliance conditions • Discussion of the facility’s environmental impacts. During the 2010 permit year, approximately 2.2 million gallons of treated wastewater was land-applied to the irrigation area at Central Facilities Area Sewage Treatment plant.

99 GENERAL AND MISCELLANEOUS↗

Final corrective action study for the former CCC/USDA facility in Ramona, Kansas.

Past operations at a grain storage facility formerly leased and operated by the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) in Ramona, Kansas, resulted in low concentrations of carbon tetrachloride in groundwater that slightly exceed the regulatory standard in only one location. As requested by the Kansas Department of Health and Environment, the CCC/USDA has prepared a Corrective Action Study (CAS) for the facility. The CAS examines corrective actions to address groundwater impacted by the former CCC/USDA facility but not releases caused by other potential groundwater contamination sources in Ramona. Four remedial alternatives were considered in the CAS. The recommended remedial alternative in the CAS consists of Environmental Use Control to prevent the inadvertent use of groundwater as a water supply source, coupled with groundwater monitoring to verify the continued natural improvement in groundwater quality. The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) has directed Argonne National Laboratory to prepare a Corrective Action Study (CAS), consistent with guidance from the Kansas Department of Health and Environment (KDHE 2001a), for the CCC/USDA grain storage facility formerly located in Ramona, Kansas. This effort is pursuant to a KDHE (2007a) request. Although carbon tetrachloride levels at the Ramona site are low, they remain above the Kansas Tier 2 risk-based screening level (RBSL) and the U.S. Environmental Protection Agency (EPA) maximum contaminant level (MCL) of 5 {micro}g/L (Kansas 2003, 2004). In its request for the CAS, the KDHE (2007a) stated that, because of these levels, risk is associated with potential future exposure to contaminated groundwater. The KDHE therefore determined that additional measures are warranted to limit future use of the property and/or exposure to contaminated media as part of site closure. The KDHE further requested comparison of at least two corrective action alternatives to the 'no-action' alternative, as the basis for the Draft Corrective Action Decision for the site. The history and nature of the contamination and previous investigations are summarized in Section 2. Also included in Section 2 is an evaluation of human and environmental targets and potential exposure pathways. Section 3 describes the corrective action goals and applicable or relevant and appropriate requirements (ARARs). Section 4 describes four alternatives, Section 5 analyzes the alternatives in detail, and Section 6 compares the alternatives. Section 6 also includes a summary and a recommended corrective action.

54 ENVIRONMENTAL SCIENCES↗

Massachusetts Large Blade Test Facility Final Report

Project Objective: The Massachusetts Clean Energy Center (CEC) will design, construct, and ultimately have responsibility for the operation of the Large Wind Turbine Blade Test Facility, which is an advanced blade testing facility capable of testing wind turbine blades up to at least 90 meters in length on three test stands. Background: Wind turbine blade testing is required to meet international design standards, and is a critical factor in maintaining high levels of reliability and mitigating the technical and financial risk of deploying massproduced wind turbine models. Testing is also needed to identify specific blade design issues that may contribute to reduced wind turbine reliability and performance. Testing is also required to optimize aerodynamics, structural performance, encourage new technologies and materials development making wind even more competitive. The objective of this project is to accelerate the design and construction of a large wind blade testing facility capable of testing blades with minimum queue times at a reasonable cost. This testing facility will encourage and provide the opportunity for the U.S wind industry to conduct more rigorous testing of blades to improve wind turbine reliability.

17 WIND ENERGY↗

Closure Report for Corrective Action Unit 116: Area 25 Test Cell C Facility, Nevada National Security Site, Nevada

This Closure Report (CR) presents information supporting closure of Corrective Action Unit (CAU) 116, Area 25 Test Cell C Facility. This CR complies with the requirements of the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the State of Nevada; the U.S. Department of Energy (DOE), Environmental Management; the U.S. Department of Defense; and DOE, Legacy Management (FFACO, 1996 [as amended March 2010]). CAU 116 consists of the following two Corrective Action Sites (CASs), located in Area 25 of the Nevada National Security Site: (1) CAS 25-23-20, Nuclear Furnace Piping and (2) CAS 25-41-05, Test Cell C Facility. CAS 25-41-05 consisted of Building 3210 and the attached concrete shield wall. CAS 25-23-20 consisted of the nuclear furnace piping and tanks. Closure activities began in January 2007 and were completed in August 2011. Activities were conducted according to Revision 1 of the Streamlined Approach for Environmental Restoration Plan for CAU 116 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2008). This CR provides documentation supporting the completed corrective actions and provides data confirming that closure objectives for CAU 116 were met. Site characterization data and process knowledge indicated that surface areas were radiologically contaminated above release limits and that regulated and/or hazardous wastes were present in the facility.

54 ENVIRONMENTAL SCIENCES↗