Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Survey of quantitative data on the solar energy and its spectra distribution

This paper presents a survey of available quantitative data on the total and spectral solar irradiance at ground level and outside the atmosphere. Measurements from research aircraft have resulted in the currently accepted NASA/ASTM standards of the solar constant and zero air mass solar spectral irradiance. The intrinsic variability of solar energy output and programs currently under way for more precise measurements from spacecraft are discussed. Instrumentation for solar measurements and their reference radiation scales are examined. Insolation data available from the records of weather stations are reviewed for their applicability to solar energy conversion. Two alternate methods of solarimetry are briefly discussed.

Thekaekara, M. P.↗

Assessment of Uncertainty in the Determination of Activation Energy for Polymeric Materials

An assessment of the experimental uncertainty in obtaining the kinetic activation energy from thermogravimetric analysis (TGA) data is presented. A neat phenolic resin, Borden SC1O08, was heated at three heating rates to obtain weight loss vs temperature data. Activation energy was calculated by two methods: the traditional Flynn and Wall method based on the slope of log(q) versus 1/T, and a modification of this method where the ordinate and abscissa are reversed in the linear regression. The modified method produced a more accurate curve fit of the data, was more sensitive to data nonlinearity, and gave a value of activation energy 75 percent greater than the original method. An uncertainty analysis using the modified method yielded a 60 percent uncertainty in the average activation energy. Based on this result, the activation energy for a carbon-phenolic material was doubled and used to calculate the ablation rate In a typical solid rocket environment. Doubling the activation energy increased surface recession by 3 percent. Current TGA data reduction techniques that use the traditional Flynn and Wall approach to calculate activation energy should be changed to the modified method.

Darby, Stephania P.↗

Search for annual modulation in low-energy CDMS-II data

We report limits on annual modulation of the low-energy event rate from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Such a modulation could be produced by interactions from Weakly Interacting Massive Particles (WIMPs) with masses ~10 GeV/c^2. We find no evidence for annual modulation in the event rate of veto-anticoincident single-detector interactions consistent with nuclear recoils, and constrain the magnitude of any modulation to <0.06 event [keVnr kg day]^-1 in the 5-11.9 keVnr energy range at the 99% confidence level. These results disfavor an explanation for the reported modulation in the 1.2-3.2 keVee energy range in CoGeNT in terms of nuclear recoils resulting from elastic scattering of WIMPs at >98% confidence. For events consistent with electron recoils, no significant modulation is observed for either single- or multiple-detector interactions in the 3.0-7.4 keVee range.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Practical Comparison of Data-Driven Prognostics Methods for Energy Systems

This study explores data-driven prognostics for nuclear power plant (NPP) condensers, focusing on tube fouling. We utilized the Asherah nuclear power plant simulator (ANS) to compare four methods: Random Forest (RF), Support Vector Regressor (SVR), Fully Connected Neural Network (FCNN), and Long Short-Term Memory Neural Network (LSTM). By simulating various fouling scenarios in the ANS, we generated data with different degradation rates under transient operations. The models were trained and tested on these data, with performance evaluated visually and numerically including uncertainty assessment. The LSTM model excelled, exhibiting minimal prediction noise and the most accurate remaining useful life estimates across all degradation levels. Its ability to capture long-term dependencies and produce cleaner outputs makes it a strong candidate, although accurate training data across the entire component lifespan are crucial. The RF model emerged as a robust alternative, providing reliable predictions with high confidence. The FCNN and SVR models, while less effective overall, showed potential under specific conditions. FCNN offers a less complex alternative to LSTM and might benefit from larger datasets. SVR excels in precision when the quality of the training data is high. Furthermore, this study highlights the operational benefits of advanced prognostics in the energy sector and emphasizes the need for further research in NPP condenser health management through real-life experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electron impact excitation of the electronic states of N2. III - Transitions in the 12.5-14.2-eV energy-loss region at incident energies of 40 and 60 eV

Analysis of electron energy-loss data at incident electron energies of 40 and 60 eV has led to the determination of normalized absolute differential cross sections for electron-impact excitation of five optically-allowed singlet states, two known triplet states, and two unknown triplet-like states of N2, lying in the energy-loss range 12.5-14.2 eV. The range of scattering angles was 5 to 138 deg. The optically allowed transitions and the known triplet excitations are identified. Cross sections for excitation to two unidentified triplet-like states at 13.155 and 13.395 eV were also obtained. The relationship of the generalized oscillator strength for the dipole-allowed states obtained from the described data to known optical oscillator strengths is discussed.

Chutjian, A.↗

NLR HPC Facility Power Usage Effectiveness (PUE) Data

Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness

97 MATHEMATICS AND COMPUTING↗

TEP Power Partners Project [Tucson Electric Power]

The Arizona Governor’s Office of Energy Policy, in partnership with Tucson Electric Power (TEP), Tendril, and Next Phase Energy (NPE), formed the TEP Power Partners pilot project to demonstrate how residential customers could access their energy usage data and third party applications using data obtained from an Automatic Meter Reading (AMR) network. The project applied for and was awarded a Smart Grid Data Access grant through the U.S. Department of Energy. The project participants’ goal for Phase I is to actively engage 1,700 residential customers to demonstrate sustained participation, reduction in energy usage (kWh) and cost ($), and measure related aspects of customer satisfaction. This Demonstration report presents a summary of the findings, effectiveness, and customer satisfaction with the 15-month TEP Power Partners pilot project. The objective of the program is to provide residential customers with energy consumption data from AMR metering and empower these participants to better manage their electricity use. The pilot recruitment goals included migrating 700 existing customers from the completed Power Partners Demand Response Load Control Project (DRLC), and enrolling 1,000 new participants. Upon conclusion of the project on November 19, 2013; 1,390 Home Area Networks (HANs) were registered; 797 new participants installed a HAN; Survey respondents’ are satisfied with the program and found value with a variety of specific program components; Survey respondents report feeling greater control over their energy usage and report taking energy savings actions in their homes after participating in the program; On average, 43 % of the participants returned to the web portal monthly and 15% returned weekly; and An impact evaluation was completed by Opinion Dynamics and found average participant savings for the treatment period1 to be 2.3% of their household use during this period.2 In total, the program saved 163 MWh in the treatment period of 2013.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis on Evaluations of Monterey Bay Aquarium Research Institute’s Wave Energy Converter’s Field Data Using WEC-Sim and Gazebo: A Simulation Tool Comparison

Although many studies have validated wave energy converter (WEC) numerical models against scaled prototype experimental data, there remains a notable lack of validation using data from full-scale deployed WECs. This paper compares two numerical models of Monterey Bay Aquarium Research Institute’s Wave Energy Converter (MBARI-WEC), a two-body point absorber with an electro-hydraulic power take-off system (PTO). The models are implemented in WEC-Sim/Simscape and Gazebo Simulator. A statistical analysis of the models was performed, and field results were obtained to compare the models’ accuracy in predicting the RMS piston velocity, RMS motor speed, and mean electric power compared to field data for 56 observations across varying sea states. The Gazebo model demonstrated a closer agreement across all three parameters for a majority of the observations. When compared to the field data, the Gazebo and WEC-Sim models exhibited average mean electric power overestimations of 13% and 22%, respectively.

16 TIDAL AND WAVE POWER↗

IEA EBC annex 53: Total energy use in buildings—Analysis and evaluation methods

One of the most significant barriers to achieving deep building energy efficiency is a lack of knowledge about the factors determining energy use. In fact, there is often a significant discrepancy between designed and real energy use in buildings, which is poorly understood but are believed to have more to do with the role of human behavior than building design. Building energy use is mainly influenced by six factors: climate, building envelope, building services and energy systems, building operation and maintenance, occupants’ activities and behavior, and indoor environmental quality. In the past, much research focused on the first three factors. However, the next three human-related factors can have an influence as significant as the first three. Annex 53 employed an interdisciplinary approach, integrating building science, architectural engineering, computer modeling and simulation, and social and behavioral science to develop and apply methods to analyze and evaluate the real energy use in buildings considering the six influencing factors. Finally, outcomes from Annex 53 improved understanding and strengthen knowledge regarding the robust prediction of total energy use in buildings, enabling reliable quantitative assessment of energy-savings measures, policies, and techniques.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unitarity of the Cabibbo-Kobayashi-Maskawa matrix and a nonuniversal gauge interaction model

Recent measurements of |V{sub us}| from kaon decays strongly support the unitarity of the Cabibbo-Kobayashi-Maskawa matrix. The unitarity provides a stringent constraint on the parameter space of the nonuniversal gauge interaction model based on the separate SU(2){sub L} gauge group acting on the third generation fermions. I show that this constraint is stronger than those from the CERN LEP and SLC data and low-energy experiment data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identifying Inefficient Single-Family Homes With Utility Bill Analysis: Preprint

Differentiating between energy-efficient and inefficient single-family homes on a community scale helps identify and prioritize candidates for energy-efficiency upgrades. Prescreening diagnostic procedures can further retrofit efforts by providing efficiency information before a site-visit is conducted. We applied the prescreening diagnostic to a simulated community of homes in Boulder, Colorado and analyzed energy consumption data to identify energy-inefficient homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Methodology to Quantify Residential Energy-Efficiency in a Heating-Dominated Climate

A methodology is presented that uses readily available information such as energy consumption data, limited building characteristics, and local daily temperature data to identify energy-inefficient homes in a heating-dominated climate. Specifically, this methodology is applied to 327 owner-occupied, single-family homes in Boulder, Colorado, which are compared to simulated prototype homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An in vivo dose verification method for SBRT–VMAT delivery using the EPID

Purpose: Radiation treatments have become increasingly more complex with the development of volumetric modulated arc therapy (VMAT) and the use of stereotactic body radiation therapy (SBRT). SBRT involves the delivery of substantially larger doses over fewer fractions than conventional therapy. SBRT–VMAT treatments will strongly benefit from in vivo patient dose verification, as any errors in delivery can be more detrimental to the radiobiology of the patient as compared to conventional therapy. Electronic portal imaging devices (EPIDs) are available on most commercial linear accelerators (Linacs) and their documented use for dosimetry makes them valuable tools for patient dose verification. In this work, the authors customize and validate a physics-based model which utilizes on-treatment EPID images to reconstruct the 3D dose delivered to the patient during SBRT–VMAT delivery. Methods: The SBRT Linac head, including jaws, multileaf collimators, and flattening filter, were modeled using Monte Carlo methods and verified with measured data. The simulation provides energy spectrum data that are used by their “forward” model to then accurately predict fluence generated by a SBRT beam at a plane above the patient. This fluence is then transported through the patient and then the dose to the phosphor layer in the EPID is calculated. Their “inverse” model back-projects the EPID measured focal fluence to a plane upstream of the patient and recombines it with the extra-focal fluence predicted by the forward model. This estimate of total delivered fluence is then forward projected onto the patient’s density matrix and a collapsed cone convolution algorithm calculates the dose delivered to the patient. The model was tested by reconstructing the dose for two prostate, three lung, and two spine SBRT–VMAT treatment fractions delivered to an anthropomorphic phantom. It was further validated against actual patient data for a lung and spine SBRT–VMAT plan. The results were verified with the treatment planning system (TPS) (ECLIPSE AAA) dose calculation. Results: The SBRT–VMAT reconstruction model performed very well when compared to the TPS. A stringent 2%/2 mm χ-comparison calculation gave pass rates better than 91% for the prostate plans, 88% for the lung plans, and 86% for the spine plans for voxels containing 80% or more of the prescribed dose. Patient data were 86% for the lung and 95% for the spine. A 3%/3 mm χ-comparison was also performed and gave pass rates better than 93% for all plan types. Conclusions: The authors have customized and validated a robust, physics-based model that calculates the delivered dose to a patient for SBRT–VMAT delivery using on-treatment EPID images. The accuracy of the results indicates that this approach is suitable for clinical implementation. Future work will incorporate this model into both offline and real-time clinical adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

brulilo, Version 0.x

brulilo is a Python package for building and evolving thermonuclear reaction networks, such as those used in astrophysical explosion calculations. It is very much a current work in progress, and much of the intended functionality is still under development. The main goal of brulilo is an easy-to-use code for quick calculations or post-processing, as well as a learning tool to test various implementations of solvers on both CPUs and GPUs. Currently, brulilo parses an input text file that specifies the reactions to be included in the network. The notation of the inputs are in the typical astrophysical notation; i.e. hydrogen burning to deuterium in the sun, "p + p + e --> d + neutrino", is given as "p(p,)d." Each reaction is added to a list comprising the reaction network, and once completed, the network contains a list of all isotopes and reactions involved. brulilo then parses publicly available nuclear data (binding energy, spin, partition function data, etc.) for each isotope from the WebNucleo group's data at nucleo.ces.clemson.edu. Fits to reaction rate data for each reaction are obtained from the publicly available data provided by the Joint Institute for Nuclear Astrophysics' Reaclib database. Reverse reactions are calculated from detailed balance. The reaction network then consists of a sparse system of mathematically stiff ordinary differential equations (ODEs). Physically, "stiffness" here means that there are some reaction rates that are occurring much faster than others; the ratio of the fast to slow often being greater than 10^15 in astrophysics. Numerical integration of such systems typically involves implicit integration schemes, which brulilo will leverage from the scientific computing Python package, Numpy, as well as implement its own. There has recently been work from researchers at Oak Ridge National Lab who have found good results from applying quasi-equilibrium and quasi-asymptotic conditions to the stiff system of ODEs, which effectively remove some of the stiffness and allow for efficient explicit integration techniques to be used. The original intent of brulilo was to implement these stiffness-alleviating techniques with explicit integrators and compare the performance to traditional implicit integrations of the full stiff system. This is still underway, as the code is very much in an alpha-release state. Furthermore, explicit integrators are often much easier to parallelize than their implicit counterparts. brulilo will implement parallelization of these techniques, leveraging both the Python implementation of MPI, mpi4py, as well as highly parallelized versions targeted at GPUs with PyOpenCL and/or PyCUDA.

Malone, Chris↗

Implementation of ISO 50001 at Marine Corps Air Station Beaufort

The ISO 50001 implementation demonstration at U.S. Marine Corps Air Station (MCAS) Beaufort proved the feasibility of integrating an ISO 50001-conforming EnMS into existing command structures. The approach of leveraging external experts in gap analysis, EnMS training, and technical assistance were effective. In addition, strong leadership commitment and personnel resources were critical for success. Addressing typical personnel rotations by training newly rotated personnel and partnering key leadership positions in the EnMS structure with civilian counterparts can ensure program continuity. The project team brought forward many creative solutions that address the unique challenges for the Marine Corps and has paved the way for future Marine Corps EnMS implementations with example strategies and work products. Implementation of an ISO 50001 EnMS at additional Marine Corps facilities could provide for integration of base energy-related data systems and standardized energy reporting, using meaningful metrics for energy performance improvement. Beyond the energy performance improvement benefits of ISO 50001, widespread adoption of the standard at Marine Corps facilities would provide the communication and integration basis on which to reduce energy resiliency concern and could integrate energy service cyber security protections base wide. High levels of energy consumption, aggressive mandates from multiple sources, complex organizational structures, and constant personnel rotation make ISO 50001 a uniquely attractive proposition for the Marine Corps in support of the DoD’s overall energy strategy. The recently launched Energy Ethos and Unit Energy Manager (UEM) programs offer dynamic action-based programs over which ISO 50001 based business management can provide integrated governance of the Marine Corps installations’ energy programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stakeholder Engagement Strategy Guide

This document provides guidance on designing a productive stakeholder engagement and outreach strategy to support the development of whole-building data access solutions as part of a successful energy benchmarking policy for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗