Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EVALUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Growth modeling to evaluate alternative cultivation strategies to enhance national microalgal biomass production

In this paper, we present a model-based assessment of alternative cultivation strategies on algal biomass production within the conterminous United States. Our assessment focuses on two basic cultivation strategies: 1) seasonal rotation of three representative freshwater algal strains that are well suited for warm weather, cold weather, and all-season diverse weather conditions, respectively; and 2) variation between three open pond water depths (15cm, 20cm, and 25cm). The enhanced Biomass Assessment Tool (BAT) is applied on a site-specific, hourly basis at 5,832 North American Land Data Assimilation System Phase 2 1/8° meteorological model grid cells over a 30-year period (1980-2009) to evaluate the operational strategies. Recognizing that resource management decisions may also consider scales beyond the individual site, we also conduct a regional assessment of focused on 7 representative climate zones in the conterminous United States. Results demonstrate that the spatial variability of algal productivity is largely affected by the strain-specific growth response to light and temperature that vary significantly by climate zone and latitude. Therefore, with a limited set of alternative cultivation strategies, the BAT identified the best performing combination of cultivation strategies on a site-specific basis that considerably enhances national annual biomass productivity. Specifically, the appropriate choice of seasonal strain rotation is able to significantly dampen climate-driven seasonal and spatial variability.

59 BASIC BIOLOGICAL SCIENCES↗

An evaluation of methodology to determine algal genome completeness

The advancement of sequencing technologies has resulted in a rapid expansion of genome sequencing. One challenge in processing and analyzing this abundance of genomics data is development and application of tools to accurately assess the quality of novel genomes. The quality of a given genome assembly is commonly assessed using the presence of conserved orthologs. However, the applicability and accuracy of identifying conserved orthologs applied to algal genome assemblies, which are uniquely diverse, is unclear. Here, in this study, we analyze the utility of a genome content assessment tool, Benchmarking Universal Single-Copy Orthologs (BUSCO), to evaluate algal genome assembly completeness. We find that Chlorophyta and Stramenopile BUSCO databases are effective tools to analyze genome completeness of these lineages. For other lineages, the Eukaryota database should be utilized until additional lineage-specific databases are developed. Based on these results, suggested best practices for current usage and necessary future improvements are provided.

59 BASIC BIOLOGICAL SCIENCES↗

Comparative performance and technoeconomic analyses of two microalgae harvesting systems evaluated at a commercially relevant scale

Using a commercially scalable system designed for processing thousands of liters a day, here we evaluated the factors that affected the performance, energy consumption and capital/operating costs of both flocculation-based and filtration-based algal harvesting systems over a 16 month period. Coagulation efficiency was the primary driver of harvest efficiency in the flocculation-based method, while cell lysis was important for the filtration-based method. Culture (algae) age differentially influenced harvest efficiency through changes in cell fragility and stickiness. The average energy consumption of the flocculation-based method was 0.389 kWh/m 3 , while that for the filtration-based method was 4.343 kWh/m 3 . The average harvesting cost of the filtration-based method was 5.35 $\$$/m 3 , while for flocculation-based method it was 4.52 $\$$/m 3 . The concentration factor of filtration-based and flocculation-based method were 770–1086 and 407–448, respectively. For both harvesting methods, labor costs dominated and ranged from 55.84%–67.94% of total cost. Further system automation is a potential method to lower the harvesting cost. The filtration-based harvesting method could produce a better quality of algal biomass with higher concentration factors and less ash content, but needed more energy input, as compared with a flocculation-based method. This study highlights the importance of algal culture status to successful harvesting, and it also provides insight into developing more efficient harvesting technology with lower energy and capital cost.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of microalgae cultivation at air-CO 2 equilibrium pH for improving carbon utilization efficiency

Microalgae are often cultivated at near-neutral pH to optimize growth. However, this results in significant CO 2 loss through outgassing in open-pond cultivation systems, leading to low CO 2 utilization efficiency and higher biomass production costs. One potential solution is algal cultivation at air-CO 2 equilibrium pH, which minimizes CO 2 outgassing but may inhibit growth due to stresses at higher pH levels. In this study, we evaluated the viability of this approach by growing Picochlorum celeri and Tetraselmis striata under outdoor relevant conditions at equilibrium pH. Compared to pH 7 cultures, biomass productivity declined by 35 % for P. celeri and 57 % for T. striata. Although CO 2 outgassing could be minimized, the significant loss in productivity led to a higher overall minimum biomass selling price (MBSP). Increased ammonia toxicity at the higher pH was found to be one of the growth-limiting factors and was mitigated by reducing ammonium fertilizer concentration. This adjustment resulted in a more moderate productivity decline of 13 % (instead of 35 %) for T. striata, and consequently, a lower MBSP was achieved. These findings suggest that equilibrium pH cultivation may be a viable method for reducing CO 2 loss without significantly compromising biomass productivity. Depending on the strain, strategies to mitigate stressors, such as ammonia toxicity, may be necessary.

09 BIOMASS FUELS↗

Evaluation of mitigation strategies for radioactive fission gases in fluoride-salt-cooled high-temperature reactors

Here, the Fluoride-salt-cooled High-temperature Reactor (FHR) is a promising Generation IV nuclear reactor due to its improved safety design, near atmospheric working pressure, and high electric power conversion efficiency. However, control of radioactive fission gases, such as tritium, is a critical issue in FHRs due to the significantly larger production rate and potentially larger leakage rate of tritium compared to those in Light Water Reactors (LWRs). Therefore, this study proposes two mitigation strategies for tritium in FHRs: Double-Wall Heat eXchanger with a Tritium Carrier (DWHX-TC) option and Single-Wall Heat eXchanger with a Tritium Barrier (SWHX-TB) option. For the DWHX-TC option, two tube surface configurations, i.e., plain and fluted tubes, and four tritium carriers, i.e., helium, FLiBe, FLiNaK, and KF-ZrF 4 , are initially considered, among which the best tube configuration and promising tritium carrier are then selected and used for design optimization of the DWHX. For the SWHX-TB option, two cases, tritium barriers with and without cracks, are investigated in this study. In addition, the two mitigation strategies are evaluated by an in-house, one-dimensional, coupled HEat and MAss Transfer (HEMAT) code developed to predict the leakage rate of tritium in nuclear systems. Our analysis shows that (1) a double-wall configuration using fluted tubes as both the inner and outer tubes is better than other double-wall configurations investigated; (2) helium, as a tritium carrier, is superior to other candidates, including FLiBe, FLiNaK, and KF-ZrF 4 ; (3) the leakage rate of tritium (into the atmosphere) is reduced from 3400 Ci/day, taking the Advanced High-Temperature Reactor (AHTR) as a reference, to 4.0 Ci/day for an optimum design of the DWHX-TC option using helium as the tritium carrier and 1.7 Ci/day for an optimum design of the SWHX-TB option using 30-µm thick silicon carbide (SiC) as the tritium barrier (no cracks); and (4) potential cracks in tritium barriers may significantly deteriorate mass transfer performance of the SWHX-TB option. For example, a cracking rate of 0.1% leads to an increase of 694.1% in the leakage rate under the conditions investigated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multiphysics analysis of fuel fragmentation, relocation, and dispersal susceptibility–Part 3: Thermal hydraulic evaluation of large break LOCA under high-burnup conditions

Increasing the peak rod average burnup of pressurized water reactor (PWR) fuel beyond 62 GWd/tU may increase fuel fragmentation, relocation, and dispersal (FFRD) susceptibility during a large break loss of coolant accident (LBLOCA). TRACE thermal hydraulic (TH) LBLOCA analyses were performed for a realistic 24-month high-burnup PWR equilibrium cycle, to inform subsequent transient BISON high-burnup FFRD susceptibility evaluations. Realistic LBLOCA systems behavior was first established by configuring to and comparing with the BEMUSE OECD LBLOCA benchmark. Fuel and operating conditions were then applied from high-burnup VERA depletion calculations. LBLOCA simulations were performed for 281 selected high-burnup rods, for which transient TH boundary conditions were collected for later use in BISON. The TRACE results indicated that rod linear heat rate (rather than burnup) is the main predictor of peak cladding temperature (PCT) during the event. PCT typically occurred at a local burnup lower than the rod-average burnup, especially for twice-burned fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Model for Evaluating the Configuration and Dispatch of PV Plus Battery Power Plants

An open-source model was developed to optimize energy storage operation for photovoltaic- (PV-) plus-battery systems with AC-coupled and DC-coupled configurations. It includes the ability to use forecast energy prices to optimize battery charge and discharge on a rolling time horizon. The model allows for exploration of different configurations, including capital costs, inverter performance, dispatch flexibility, and capturing otherwise clipped energy for the DC-coupled system. The model can run 20 full years of hourly data in approximately two seconds, allowing comparison of a large number of configurations. We applied the model in a test case demonstrating reduced inverter clipping for DC-coupled systems and yielded slightly higher overall value than AC-coupled systems, with an approximately 2 percent increase in internal rate of return or benefit/cost ratio. Our results show that at current estimated prices for lithium-ion battery systems, large-scale PV-plus-battery plants are economically viable under the right conditions, with the configuration playing a role in system flexibility and performance. This model provides the ability for project developers, industry professionals, and researchers to use readily available software to quickly evaluate and design these systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Evaluation of smart charging for electric vehicle-to-building integration: A case study

Higher electric vehicle (EV) adoption will stress the importance of demand flexibility to achieve more economic, efficient, and reliable grid operation. Charging technologies will be paramount in shifting temporally to better fit the variable generation of wind and solar. As such, analysis is warranted on the benefits of EV charge scheduling with respect to installation cost, operation cost, difficulty of implementation, and grid flexibility. We tackle this by analyzing the cost savings of implementing an EV charge scheduling infrastructure to reduce demand charges and installation costs. In this paper, we analyze a case study for operation of 16 level 2 chargers and 1 fast charger for two different building types. We then evaluate various test phases for controlling building and charging loads using an adaptive charging network (ACN) algorithm to characterize the ACN’s potential to reduce overall project cost.

30 DIRECT ENERGY CONVERSION↗

Development of an integrated platform for hardware-in-the-loop evaluation of microgrids prior to site commissioning

This paper presents an integrated hardware-in-the-loop (HIL) platform for testing the operation and control of a real-world microgrid system prior to site commissioning. The proposed testing approach shows the value of setting up an integrated HIL platform to test multiple hardware devices (including the system-level controller, device controllers, and field devices). A test bed developed for the Borrego Springs community microgrid is used as an example to demonstrate the feasibility of the integrated platform. Comprehensive tests are carried out using the Borrego Springs test bed to validate the platform, meet the test objectives, and gain valuable insight prior to site commissioning. The selected test scenarios, initial conditions, events, test metrics, etc., are similar to those defined in IEEE P2030.8. The test objectives are to evaluate the microgrid controller and the operation of the microgrid. The HIL platform presented in this paper shows good value for microgrid testing in terms of its flexibility and scalability for testing various microgrids; its accuracy in its representation of the field; the comprehensiveness of the testing capability; and the efficiency of testing, which can reduce risks prior to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and performance evaluation of a dual-circuit thermal energy storage module for air conditioners

We present experimental results and a validated numerical model of a dual-circuit phase-change thermal energy storage module for air conditioners. The module incorporates a phase-change material encapsulated in compressed expanded natural graphite foam. We used n-tetradecane as the PCM with a transition temperature (~4.5 °C) suitable for air-conditioning applications. Heat exchange to and from the module is accomplished through two fluid loops operating as a heat source and sink embedded inside multiple slabs of the composite material. This dual-circuit design enables easier integration with air-conditioning equipment and provides enhanced flexibility in system operation as compared to the state-of-the-art thermal storage systems. When integrated with an air-conditioner, this design will enable peak-load shaving and enhances operational efficiency. The thermal storage device was designed for a nominal storage capacity of ~ 3.5 kWh. We evaluated the heat transfer and energy storage performance of this device using standalone heat transfer experiments to estimate key thermal resistances and identify design improvements before integration with an air conditioner. The numerical model of the heat exchanger uses a combination of discretized and lumped parameter approaches to maintain a balance between accuracy and computational expense. Our analyses show that the geometric features and integration of fluid tubes are key contributors to the thermal contact resistance between the fluid and the thermal storage material, and consequently, to the overall performance of the thermal storage module. Our standalone experiments also identified important operating scenarios in which this thermal storage module can be used for air-conditioning in buildings.

25 ENERGY STORAGE↗

Evaluating the Feasibility of Transactive Approach for Voltage Management Using Inverters of a PV Plant

This article evaluates the feasibility of a double-auction-based Transactive Energy System (TES) for engaging the reactive power (Var) capability of inverters in a utility-scale pho¬tovoltaic (PV) plant for voltage management in distribution feed¬ers. In this approach, a PV plant owner (seller) provides Var supply curves in terms of price-quantity pairs consider¬ing the inverters’ P-Q capability, efficiency, opportunity cost for real power curtail¬ment, losses, etc. At the same time, the utility (buyer) proposes Var demand curves in price-quantity pairs exhibiting the marginal price of Var. Then, market clearing points are obtained from the intersection points of supply and demand curves which are then used to create Var dispatch sig-nals from the PV plant. To conduct a fea¬sibility study of this approach, an Australian distribution network with a utility-scale PV plant (capacity 3.275 MWP) is modeled in RSCAD and simu¬lated in real-time on MATLAB, RSCAD-RTDS co-simulation platform using real historical data. Consid¬ering a use case, namely, conservation voltage reduction (CVR), the operational feasibility along with cost-benefit analysis is demonstrated in software-in-the-loop (SIL) and hardware-in-the-loop (HIL) platform. Another use case, exploring the benefit from tap-change reduction of step-voltage-regulator, is investigated. These studies explore further use cases, e.g., PV hosting capacity, network reconfiguration, etc., to be incorporated in TES for experiencing substantial economic benefits.

Alam, Mollah Rezaul↗

Evaluating long-term emission impacts of large-scale electric vehicle deployment in the US using a human-Earth systems model

While large-scale adoption of electric vehicles (EVs) globally would reduce carbon dioxide (CO 2 ) and traditional air pollutant emissions from the transportation sector, emissions from the electric sector, refineries, and potentially other sources would change in response. Here, a multi-sector human-Earth systems model is used to evaluate the net long-term emission implications of large-scale EV adoption in the US over widely differing pathways of the evolution of the electric sector. Our results indicate that high EV adoption would decrease net CO 2 emissions through 2050, even for a scenario where all electric sector capacity additions through 2050 are fossil fuel technologies. Greater net CO 2 reductions would be realized for scenarios that emphasize renewables or decarbonization of electricity production. Net air pollutant emission changes in 2050 are relatively small compared to expected overall decreases from recent levels to 2050. States participating in the Regional Greenhouse Gas Initiative experience greater CO 2 and air pollutant reductions on a percentage basis. These results suggest that coordinated, multi-sector planning can greatly enhance the climate and environmental benefits of EVs. Additional factors are identified that influence the net emission impacts of EVs, including the retirement of coal capacity, refinery operations under reduced gasoline demands, and price-induced fuel switching in residential heating and in the industrial sector.

54 ENVIRONMENTAL SCIENCES↗

Site demonstration and performance evaluation of MPC for a large chiller plant with TES for renewable energy integration and grid decarbonization

Thermal energy storage (TES) for a cooling plant is a crucial resource for load flexibility. Traditionally, simple, heuristic control approaches, such as the storage priority control which charges TES during the nighttime and discharges during the daytime, have been widely used in practice, and shown reasonable performance in the past benefiting both the grid and the end-users such as buildings and district energy systems. However, the increasing penetration of renewables changes the situation, exposing the grid to a growing duck curve, which encourages the consumption of more energy in the daytime, and volatile renewable generation which requires dynamic planning. The growing pressure of diminishing greenhouse gas emissions also increases the complexity of cooling TES plant operations as different control strategies may apply to optimize operations for energy cost or carbon emissions. This paper presents a model predictive control (MPC), site demonstration and evaluation results of optimal operation of a chiller plant, TES and behind-meter photovoltaics for a campus-level district cooling system. The MPC was formulated as a mixed-integer linear program for better numerical and control properties. Compared with baseline rule-based controls, the MPC results show reductions of the excess PV power by around 25%, of the greenhouse gas emission by 10%, and of peak electricity demand by 10%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

CO 2 utilization potential of a novel calcium ferrite based looping process fueled with coal: Experimental evaluation of various coal feedstocks and thermodynamic integrated process analysis

Here, conversion of CO 2 to CO was performed at 800-850C via reduction of calcium ferrite (CaFe 2 O 4 ) with coal followed by oxidation of reduced CaFe 2 O 4 with CO 2 to produce CO and partially oxidized Ca ferrite. The process was evaluated with several types of coals which included lignite, sub-bituminous, bituminous, anthracite and pet-coke. Reduction of CaFe 2 O 4 with sub-bituminous coal and lignite coal was more favorable than that with higher rank coals. Stable reactivity performance was demonstrated for 35-cycle test conducted with lignite coal/CaFe 2 O 4 at 800°C and with high conversion of CO 2 to CO. The rate of conversion of CO 2 to CO with reduced CaFe 2 O 4 was found to be 1st order with respect to CO 2 and had a low activation energy of 7.4 kJ/mol. Thermodynamic integrated process assessments suggest that two and three reactor process concepts can be realized and net CO 2 utilization achievable. The two reactor configuration shows the highest potential for CO 2 utilization while generating a value-added CO rich syngas stream.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Technical and economic evaluation of heat transfer fluids for a TES system integrated to an advanced nuclear reactor

The utilization of thermal energy storage technology has emerged as a potential enhancement for nuclear power plants. Although nuclear energy systems possess the ability to adjust their energy output, prolonged variations in production can impact the plant's overall efficiency and economic viability. However, the nuclear industry can capitalize on thermal energy storage to bolster the power plant's economics by leveraging ancillary services and market hedging strategies. Here this research aims to advance the development of thermal energy storage for advanced nuclear reactors by assessing the thermophysical properties of various heat transfer fluids, including FLiNaK, KCl-MgCl 2 , LiCl-KCl, (LiNaK) 2 CO 3 , NaF-ZrF 4 , and KF-ZrF 4 , at temperatures ranging from 500 to 900oC. The assessment is conducted based on thermophysical correlations established in previous studies and employs figures of merit as a metric to evaluate the heat transfer performance of different salt candidates. Additionally, a cost analysis is conducted to provide an idea of the potential cost associated with each salt candidate.

25 ENERGY STORAGE↗

Evaluation of color in digital nuclear power plant control room displays

Human system interface design in industrial process control is guided by industry standards, human factors best practices, and domain-specific conventions, and often there is a conflict between one or more of the sources of design input for specific design elements. In the nuclear domain, one design element for which conflict arises is the use of color to represent equipment state. Here, this study evaluates the tradeoffs associated with using color in a process control display versus using white and shades of gray. The performance metrics were response time, accuracy, and eye movement metrics using a simplified experimental task and professional operators. Results revealed that adhering to color conventions in nuclear power yielded small advantages in simple tasks, but did not exist for more complex tasks. The results did not provide strong evidence for or against using a particular color scheme and revealed the need for further research on the use of color for commercial nuclear power plants and other process control industries.

99 GENERAL AND MISCELLANEOUS↗

Performance evaluation of a wrapped around condenser for heat pump water heater applications

In this report, accurate performance evaluation of a wrapped-around condenser for heat pump water heaters (WHPWH) is critical since the COP of the system depends heavily on thermal stratification and condenser design. An analytical, quasi-steady state heat balance method has been developed to determine the optimal spacing between adjacent channels, tube diameter, tube shape, and total refrigerant charge amount for the condenser. The heat transfer rate is compared among three approaches: the refrigerant thermodynamic model, the condenser-wrap fin model, and the analytical natural convection model on the inside of the tank for the three regions based on the refrigerant phase (e.g., super-heated, saturated, or subcooled). The heat transfer rate was predicted by a combination of slug-plug and annular flow for a D-shaped helical tube. Experimental data were used as boundary conditions for validating the model. The rate of heat transfer based on tube shape and tank wall temperatures was compared by CFD analysis. Parametric analysis indicates a tradeoff between refrigerant mass, pressure drop, tube diameter, and tube length to maximize the heat transfer rate. The model suggests the saturated region length can be extended by 400%, and the condenser pressure drop can be reduced by 23% with an optimal spacing pattern.

42 ENGINEERING↗

On the validity and limitations of 1D model for heat and mass transfer performance evaluation in a multilayer binder-free desiccant dehumidifier: isothermal dehumidification with internal cooling

Efficient humidity control is essential for maintaining indoor thermal comfort, yet conventional vapor-compression-based dehumidifiers are energy-intensive. Employing separate sensible and latent cooling through desiccant-coated heat exchangers (DCHEs) combined with evaporative coolers offers energy savings of up to 80 % compared to conventional systems. However, the dehumidification performance of DCHEs remains limited due to the use of polymer binders for coating desiccant materials onto heat exchange surfaces. In our previous study, we developed a multilayer fixed-bed binder-free desiccant dehumidifier (MFBDD) that demonstrated high dehumidification capacity and low pressure drop compared to rotary desiccant wheels. Nevertheless, its potential for further enhancement through internal cooling and the use of step-shaped adsorption isotherms has not been explored. In this study, a physics-based one-dimensional (1D) transient model is developed and validated to capture the coupled heat and mass transfer processes in the MFBDD and extended to simulate internal cooling using a high-capacity composite metal–organic framework, MIL-101/GO-6 (water uptake ≈1.6 g/g within 35–47 % RH). The model enables detailed analysis of local air and bed temperature dynamics and quantifies how internal cooling affects the dehumidification performance under a wide range of operating conditions. Results show that integrating internal cooling and using MIL-101/GO-6 enhance mass adsorbed, moisture removal capacity, and dehumidification effectiveness by 50 %–99 % compared with the M.S. Gel baseline. The study further reveals that achieving near-isothermal operation requires simultaneous enhancement of the convective heat transfer coefficient and heat exchange surface area. In conclusion, this work provides the first detailed physical insight into the interplay between internal cooling and step-shaped isotherms in a binder-free desiccant device and establishes a validated modeling framework for scaling up and system-level performance evaluation of next-generation energy-efficient dehumidification systems.

Heat and mass transfer↗