Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

EVIDENCE FOR GAMMA-RAY HALOS AROUND ACTIVE GALACTIC NUCLEI AND THE FIRST MEASUREMENT OF INTERGALACTIC MAGNETIC FIELDS

Intergalactic magnetic fields (IGMFs) can cause the appearance of halos around the gamma-ray images of distant objects because an electromagnetic cascade initiated by a high-energy gamma-ray interaction with the photon background is broadened by magnetic deflections. We report evidence of such gamma-ray halos in the stacked images of the 170 brightest active galactic nuclei (AGNs) in the 11 month source catalog of the Fermi Gamma-Ray Space Telescope. Excess over the point-spread function in the surface brightness profile is statistically significant at 3.5{sigma} (99.95% confidence level), for the nearby, hard population of AGNs. The halo size and brightness are consistent with IGMF, B {sub IGMF} {approx} 10{sup -15} G. The knowledge of IGMF will facilitate the future gamma-ray and charged-particle astronomy. Furthermore, since IGMFs are likely to originate from the primordial seed fields created shortly after the big bang, this potentially opens a new window on the origin of cosmological magnetic fields, inflation, and the phase transitions in the early universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance and Molière radius measurements using a compact prototype of LumiCal in an electron test beam

A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear e \(^{+}\) e \(^{-}\) collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY with an electron beam of energy 1–5 GeV. The performance of a prototype of a compact LumiCal comprising eight detector planes was studied. The effective Molière radius at 5 GeV was determined to be (8.1 ± 0.1 (stat) ± 0.3 (syst)) mm, a value well reproduced by the Monte Carlo (MC) simulation (8.4 ± 0.1) mm. The dependence of the effective Molière radius on the electron energy in the range 1–5 GeV was also studied. Good agreement was obtained between data and MC simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Studies of the Electromagnetic Structure of Mesons at Jefferson Lab

The Jefferson Laboratory Hall B PrimEx Collaboration is using tagged photons to perform an absolute 1.4% level cross section measurement of the photoproduction of neutral pions in the Coulomb field of a nucleus. The absolute cross section for this process is directly proportional to the neutral pion radiative decay width and consequently the uncertainty in the luminosity is directly reflected in the final error bar of the measurement. The PI has taken primary responsibility for the photon flux determination and in this technical report, we outline the steps taken to limit the uncertainty in the tagged photon flux to the 1% level. These include the use of a total absorption counter for absolute flux calibration, a pair spectrometer for online relative flux monitoring, and updated procedures for postbremsstrahlung electron counting. The photon tagging technique has been used routinely in its various forms to provide quasimonochromatic photons for absolute photonuclear cross section measurements. The analysis of such experiments in the context of bremsstrahlung photon tagging was summarized by Owens in 1990. Since then, a number of developments have made possible significant improvements in the implementation of this technique. Here, we describe the steps taken by the PrimEx Collaboration in Hall B of Jefferson Laboratory to limit the systematic uncertainty in the absolute photon flux to 1%. They include an absolute flux calibration at low intensity with a total absorption counter, online relative flux monitoring with a pair spectrometer, and the use of multihit time to digital converters for post bremsstrahlung electron counting during production data runs. While this discussion focuses on the analysis techniques utilized by the PrimEx Collaboration which involves a bremsstrahlung based photon tagging system to measure the neutral pion lifetime, the methods described herein readily apply to other types of photon tagging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils

In this paper, we propose a method to estimate the position, orientation, and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer, and model these discreetly sampled fields using vector spherical harmonics (VSH) functions. We then localize and calibrate an OPM by minimizing the sum of squared errors between the model signals and the OPM responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the OPM sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. The currents that should be applied to the coils for approximating these low-order field components can be determined based on the VSH models. Computationally simple initial estimates of the OPM sensor parameters follow. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2°, and 0.8%, respectively. Lastly, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average dipole position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.

47 OTHER INSTRUMENTATION↗

Challenges for the statistical gravitational-wave method to measure the Hubble constant

Gravitational waves (GW) can be employed as standard sirens that will soon measure the Hubble constant with sufficient precision to weigh in on the ~5σ Hubble tension. Most GW sources will have no identified electromagnetic counterpart, leading to uncertainty in the redshift of the source, and in turn a degeneracy between host galaxy distance, redshift, and H 0 . In the case where no electromagnetic counterparts are identified, it has been proposed that a statistical canvassing of candidate GW hosts, found in a large galaxy survey for example, can be used to accurately constrain the Hubble constant. We study and simulate this "galaxy voting" method to compute H 0 . Here, we find that the Hubble constant posterior is in general biased relative to the true value even when making optimistic assumptions about the statistical properties of the sample. Using the MICECAT light-cone catalog, we find that the bias in the H0 posteriors depends on the realization of the underlying galaxy sample and the precision of the GW source distance measurement.

79 ASTRONOMY AND ASTROPHYSICS↗

Electromagnetic Analysis of ITER Electron Cyclotron Emission Components and Support Structures for the Preliminary Design Review

The ITER electron cyclotron emission (ECE) diagnostic system is located at Design Shield Module (DSM) 2, Equatorial Port (EP) 9 to measure electron temperature profile and electron temperature fluctuations and also to assess nonthermal electron distributions via the oblique view. Therefore, ECE has both radial and oblique views with two couples of mirrors for two different optical views. This ECE diagnostic system shall be exposed to significant power due to unabsorbed electron cyclotron heating power in the plasma. It shall also receive large electromagnetic (EM) loads up to 100 MN/m 3 force density due to the eddy currents generated by the short 16-ms transient plasma disruption. The global EM models of EP12 and EP11 with the worst case of plasma disruption Major Disruption Downward Exponential 16 ms Category III (MD_DW_EXP16MS_CATIII) have been provided by ITER. However, the support structure for these critical components, including four mirrors, is still under the design and development phase, especially during the period of preliminary design reviews (PDRs). For those small in-vessel components that are not modeled explicitly for the PDRs, we can extract the magnetic field (B) data and flux variations (dB/dt) at those locations from the global model and then use the B and dB/dt method to calculate the eddy currents, EM forces, and torques on those components in the local submodels. In conclusion, this paper will present the detailed PDR EM analysis results of the ECE components and support structures.

Electromagnetic↗

A DEEP CHANDRA ACIS STUDY OF NGC 4151. III. THE LINE EMISSION AND SPECTRAL ANALYSIS OF THE IONIZATION CONE

This paper is the third in a series in which we present deep Chandra ACIS-S imaging spectroscopy of the Seyfert 1 galaxy NGC 4151, devoted to study its complex circumnuclear X-ray emission. Emission features in the soft X-ray spectrum of the bright extended emission (L{sub 0.3-2{sub keV}} {approx} 10{sup 40} erg s{sup -1}) at r > 130 pc (2'') are consistent with blended brighter O VII, O VIII, and Ne IX lines seen in the Chandra HETGS and XMM-Newton RGS spectra below 2 keV. We construct emission line images of these features and find good morphological correlations with the narrow-line region clouds mapped in [O III] {lambda}5007. Self-consistent photoionization models provide good descriptions of the spectra of the large-scale emission, as well as resolved structures, supporting the dominant role of nuclear photoionization, although displacement of optical and X-ray features implies a more complex medium. Collisionally ionized emission is estimated to be {approx}<12% of the extended emission. Presence of both low- and high-ionization spectral components and extended emission in the X-ray image perpendicular to the bicone indicates leakage of nuclear ionization, likely filtered through warm absorbers, instead of being blocked by a continuous obscuring torus. The ratios of [O III]/soft X-ray flux are approximately constant ({approx}15) for the 1.5 kpc radius spanned by these measurements, indicating similar relative contributions from the low- and high-ionization gas phases at different radial distances from the nucleus. If the [O III] and X-ray emission arise from a single photoionized medium, this further implies an outflow with a wind-like density profile. Using spatially resolved X-ray features, we estimate that the mass outflow rate in NGC 4151 is {approx}2 M{sub Sun} yr{sup -1} at 130 pc and the kinematic power of the ionized outflow is 1.7 Multiplication-Sign 10{sup 41} erg s{sup -1}, approximately 0.3% of the bolometric luminosity of the active nucleus in NGC 4151.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the neutron magnetic form factor at high Q-2 using the ratio method on deuterium

The 12-GeV Upgrade at Jefferson Lab will create an opportunity to dramatically extend our knowledge of the magnetic form factor of the neutron G^n_M and the other elastic, electromagnetic form factors. We describe here an approved experiment that will cover a Q2 range (3.5 – 14 GeV2) with significant discovery potential. Different theoretical approaches (generalized parton distributions, Dyson-Schwinger equations, etc) diverge is this region and existing data cannot distinguish among them. The proposed measurement will be performed in Hall B with the CLAS12 detector and will have statistical and systematic uncertainties below 3%. It is based on the ratio of electron-neutron to electron-proton scattering that was successfully applied in the CLAS detector at Jefferson Lab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Full Hemisphere Fermi Surface Mapping Using A Novel Toroidal Electron Spectrometer

An overview is provided of a next-generation toroidal angle-resolving photoemission spectrometer, currently in operation at BESSY II. The instrument features exceptional multi-detection in energy and angle, facilitating rapid full-hemisphere photoemission measurements. The instrument is ideal for band structure and Fermi Surface (FS) mapping using Angle Resolved Photoemission Spectroscopy (ARPES). Recent full-hemisphere FS measurements of a prototypical material, copper, reveal previously unseen fine structure due to lifetime broadening, demonstrating the high angular resolution and dense {kappa}-space sampling capabilities of the instrument.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulation of radiation energy release in air showers

A simulation study of the energy released by extensive air showers in the form of MHz radiation is performed using the CoREAS simulation code. We develop an efficient method to extract this radiation energy from air-shower simulations. We determine the longitudinal profile of the radiation energy release and compare it to the longitudinal profile of the energy deposit by the electromagnetic component of the air shower. We find that the radiation energy corrected for the geometric dependence of the geomagnetic emission scales quadratically with the energy in the electromagnetic component of the air shower with a second-order dependence on the atmospheric density at the position of the maximum shower development X {sub max}. In a measurement where X {sub max} is not accessible, this second order dependence can be approximated using the zenith angle of the incoming direction of the air shower with only a minor loss in accuracy. Our method results in an intrinsic uncertainty of 4% in the determination of the energy in the electromagnetic air-shower component, which is well below current experimental uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Measurement of the Hubble Constant from a Dark Standard Siren using the Dark Energy Survey Galaxies and the LIGO/Virgo Binary–Black-hole Merger GW170814

We present a multi-messenger measurement of the Hubble constant H 0 using the binary–black-hole merger GW170814 as a standard siren, combined with a photometric redshift catalog from the Dark Energy Survey (DES). The luminosity distance is obtained from the gravitational wave signal detected by the Laser Interferometer Gravitational-Wave Observatory (LIGO)/Virgo Collaboration (LVC) on 2017 August 14, and the redshift information is provided by the DES Year 3 data. Black hole mergers such as GW170814 are expected to lack bright electromagnetic emission to uniquely identify their host galaxies and build an object-by-object Hubble diagram. However, they are suitable for a statistical measurement, provided that a galaxy catalog of adequate depth and redshift completion is available. Here we present the first Hubble parameter measurement using a black hole merger. Our analysis results in , which is consistent with both SN Ia and cosmic microwave background measurements of the Hubble constant. The quoted 68% credible region comprises 60% of the uniform prior range [20, 140] km s−1 Mpc−1, and it depends on the assumed prior range. If we take a broader prior of [10, 220] km s−1 Mpc−1, we find (57% of the prior range). Although a weak constraint on the Hubble constant from a single event is expected using the dark siren method, a multifold increase in the LVC event rate is anticipated in the coming years and combinations of many sirens will lead to improved constraints on H 0.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charge Conservation beyond Uniformity: Spatially Inhomogeneous Electromagnetic Response in Periodic Solids

Nonlinear electromagnetic response functions have reemerged as a crucial tool for studying quantum materials, due to recently appreciated connections between optical response functions, quantum geometry, and band topology. Most attention has been paid to responses to spatially uniform electric fields, relevant to low-energy optical experiments in conventional solid state materials. However, magnetic and magnetoelectric phenomena are naturally connected by responses to spatially varying electric fields due to Maxwell’s equations. Furthermore, in the emerging field of moiré materials, characteristic lattice scales are much longer, allowing spatial variation of optical electric fields to potentially have a measurable effect in experiments. In order to address these issues, we develop a formalism for computing linear and nonlinear responses to spatially inhomogeneous electromagnetic fields. Starting with the continuity equation, we derive an expression for the second-quantized current operator that is manifestly conserved and model independent. Crucially, our formalism makes no assumptions on the form of the microscopic Hamiltonian and so is applicable to model Hamiltonians derived from tight-binding or calculations. We then develop a diagrammatic Kubo formalism for computing the wave vector dependence of linear and nonlinear conductivities, using Ward identities to fix the value of the diamagnetic current order by order in the vector potential. We apply our formula to compute the magnitude of the Kerr effect at oblique incidence for a model of a moiré-Chern insulator and demonstrate the experimental relevance of spatially inhomogeneous fields in these systems. We further show how our formalism allows us to compute the (orbital) magnetic multipole moments and magnetic susceptibilities in insulators. Turning to nonlinear response, we use our formalism to compute the second-order transverse response to spatially varying transverse electric fields in our moiré-Chern insulator model, with an eye toward the next generation of experiments in these systems. Published by the American Physical Society 2024

Physics↗

Evaluation of Patient Doses from Verification Techniques in Image-Guided Radiotherapy (IGRT)

The purpose of this work was an evaluation of organ doses and effective doses from kilovoltage (kV) cone-beam CT (CBCT) scans and from pairs of orthogonal kV image projections for two different treatment sites (a head and a pelvis). Measurements of organ doses were performed in an anthropomorphic rando phantom by means of thermoluminescent dosimeters (TLDs). Irradiations were performed using on-board imager (OBI) and X-ray volume imaging (XVI) systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characteristics of temperature rise in variable inductor employing magnetorheological fluid driven by a high-frequency pulsed voltage source

A variable inductor with magnetorheological (MR) fluid has been successfully applied to power electronics applications; however, its thermal characteristics have not been investigated. To evaluate the performance of the variable inductor with respect to temperature, we measured the characteristics of temperature rise and developed a numerical analysis technique. The characteristics of temperature rise were determined experimentally and verified numerically by adopting a multiphysics analysis technique. In order to accurately estimate the temperature distribution in a variable inductor with an MR fluid-gap, the thermal solver should import the heat source from the electromagnetic solver to solve the eddy current problem. To improve accuracy, the B–H curves of the MR fluid under operating temperature were obtained using the magnetic property measurement system. In addition, the Steinmetz equation was applied to evaluate the core loss in a ferrite core. The predicted temperature rise for a variable inductor showed good agreement with the experimental data and the developed numerical technique can be employed to design a variable inductor with a high-frequency pulsed voltage source.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Action of an electromagnetic pulse on a plasma with a high level of ion-acoustic turbulence. Field diffusion and subdiffusion

Specific features of the interaction of a relatively weak electromagnetic pulse with a nonisothermal current-carrying plasma in which the electron drift velocity is much higher than the ion-acoustic velocity, but lower than the electron thermal velocity, are studied. If the state of the plasma with ion-acoustic turbulence does not change during the pulse action, the field penetrates into the plasma in the ordinary diffusion regime, but the diffusion coefficient in this case is inversely proportional to the anomalous conductivity. If, during the pulse action, the particle temperatures and the current-driving field change due to turbulent heating, the field penetrates into the plasma in the subdiffusion regime. It is shown how the presence of subdiffusion can be detected by measuring the reflected field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum cascade laser investigations of CH{sub 4} and C{sub 2}H{sub 2} interconversion in hydrocarbon/H{sub 2} gas mixtures during microwave plasma enhanced chemical vapor deposition of diamond

CH{sub 4} and C{sub 2}H{sub 2} molecules (and their interconversion) in hydrocarbon/rare gas/H{sub 2} gas mixtures in a microwave reactor used for plasma enhanced diamond chemical vapor deposition (CVD) have been investigated by line-of-sight infrared absorption spectroscopy in the wavenumber range of 1276.5-1273.1 cm{sup -1} using a quantum cascade laser spectrometer. Parameters explored include process conditions [pressure, input power, source hydrocarbon, rare gas (Ar or Ne), input gas mixing ratio], height (z) above the substrate, and time (t) after addition of hydrocarbon to a pre-existing Ar/H{sub 2} plasma. The line integrated absorptions so obtained have been converted to species number densities by reference to the companion two-dimensional (r,z) modeling of the CVD reactor described in Mankelevich et al. [J. Appl. Phys. 104, 113304 (2008)]. The gas temperature distribution within the reactor ensures that the measured absorptions are dominated by CH{sub 4} and C{sub 2}H{sub 2} molecules in the cool periphery of the reactor. Nonetheless, the measurements prove to be of enormous value in testing, tensioning, and confirming the model predictions. Under standard process conditions, the study confirms that all hydrocarbon source gases investigated (methane, acetylene, ethane, propyne, propane, and butane) are converted into a mixture dominated by CH{sub 4} and C{sub 2}H{sub 2}. The interconversion between these two species is highly dependent on the local gas temperature and the H atom number density, and thus on position within the reactor. CH{sub 4}->C{sub 2}H{sub 2} conversion occurs most efficiently in an annular shell around the central plasma (characterized by 1400<T{sub gas}<2200 K), while the reverse transformation C{sub 2}H{sub 2}->CH{sub 4} is favored in the more distant regions where T{sub gas}<1400 K. Analysis of the multistep interconversion mechanism reveals substantial net consumption of H atoms accompanying the CH{sub 4}->C{sub 2}H{sub 2} conversion, whereas the reverse C{sub 2}H{sub 2}->CH{sub 4} process only requires H atoms to drive the reactions; H atoms are not consumed by the overall conversion.

36 MATERIALS SCIENCE↗

ATLOG Modeling of Buried Cables from the November 2016 HERMES Electromagnetic Pulse Experiments

This report compares ATLOG modeling results for the response of a finite-length dissipative buried conductor interacting with a conducting ground to a measurement taken November 2016 at the High-Energy Radiation Megavolt Electron Source (HERMES) facility. We use the ATLOG frequency-domain method based on transmission line theory. Estimates of the impedance per unit length and admittance per unit length for a cable laying in a PVC pipe embedded in a concrete block are reported. Current wave shapes from both a single conductor and composite differential mode and antenna mode arrangements are close to those observed in the experiments.

42 ENGINEERING↗

FIBRILLAR CHROMOSPHERIC SPICULE-LIKE COUNTERPARTS TO AN EXTREME-ULTRAVIOLET AND SOFT X-RAY BLOWOUT CORONAL JET

We observe an erupting jet feature in a solar polar coronal hole, using data from Hinode/Solar Optical Telescope (SOT), Extreme Ultraviolet Imaging Spectrometer (EIS), and X-Ray Telescope (XRT), with supplemental data from STEREO/EUVI. From extreme-ultraviolet (EUV) and soft X-ray (SXR) images we identify the erupting feature as a blowout coronal jet: in SXRs it is a jet with a bright base, and in EUV it appears as an eruption of relatively cool ({approx}50,000 K) material of horizontal size scale {approx}30'' originating from the base of the SXR jet. In SOT Ca II H images, the most pronounced analog is a pair of thin ({approx}1'') ejections at the locations of either of the two legs of the erupting EUV jet. These Ca II features eventually rise beyond 45'', leaving the SOT field of view, and have an appearance similar to standard spicules except that they are much taller. They have velocities similar to that of 'type II' spicules, {approx}100 km s{sup -1}, and they appear to have spicule-like substructures splitting off from them with horizontal velocity {approx}50 km s{sup -1}, similar to the velocities of splitting spicules measured by Sterling et al. Motions of splitting features and of other substructures suggest that the macroscopic EUV jet is spinning or unwinding as it is ejected. This and earlier work suggest that a subpopulation of Ca II type II spicules are the Ca II manifestation of portions of larger scale erupting magnetic jets. A different subpopulation of type II spicules could be blowout jets occurring on a much smaller horizontal size scale than the event we observe here.

79 ASTRONOMY AND ASTROPHYSICS↗