Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Enhanced absorption in tandem solar cells by applying hydrogenated In{sub 2}O{sub 3} as electrode

To realize the high efficiency potential of perovskite/chalcopyrite tandem solar cells in modules, hydrogenated In{sub 2}O{sub 3} (IO:H) as electrode is investigated. IO:H with an electron mobility of 100 cm{sup 2} V{sup −1} s{sup −1} is demonstrated. Compared to the conventional Sn doped In{sub 2}O{sub 3} (ITO), IO:H exhibits a decreased electron concentration and leads to almost no sub-bandgap absorption up to the wavelength of 1200 nm. Without a trade-off between transparency and lateral resistance in the IO:H electrode, the tandem cell keeps increasing in efficiency as the IO:H thickness increases and efficiencies above 22% are calculated. In contrast, the cells with ITO as electrode perform much worse due to the severe parasitic absorption in ITO. This indicates that IO:H has the potential to lead to high efficiencies, which is otherwise constrained by the parasitic absorption in conventional transparent conductive oxide electrode for tandem solar cells in modules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Why diamond dimensions and electrode geometry are crucial for small photon beam dosimetry

Recent use of very small photon beams (down to 4 mm) in stereotactic radiotherapy requires new detectors to accurately determine the delivered dose. Diamond detectors have been presented in the literature as an attractive candidate for this application, due to their small detection volume and the diamond atomic number (Z = 6) which is close to water effective atomic number (Zeff ∼ 7.42). However, diamond exhibits a density 3.51 times greater than that of water and recent studies using Monte Carlo simulations have demonstrated the drawback of a high-density detector on small beam output factors. The current study focuses on geometrical parameters of diamond detector, namely, the diamond dimensions and the electrode geometry, in order to solve the dosimetric issues still observed in small photon beams with diamond detectors. To give better insights to these open questions, we have used both computational method and experimental analysis. This study highlighted that reducing diamond dimensions is crucial for small beam output factor measurements and to limit the influence of its high density. Furthermore, electrodes covering the whole diamond surface were essential for a dose rate independence of the diamond detector. The optimal dosimeter derived from this work presented small diamond dimensions of approximately 1 × 1 × 0.15 mm{sup 3}, with diamond-like-carbon electrodes covering the whole diamond surface. A dose rate independence of this diamond detector (better than 0.5% over a wide range of dose rates available on a stereotactic dedicated facility) was obtained due to the electrode geometry. Concerning the output factor measurements, a good agreement (better than 1.1%) was observed between this carbon material detector and two types of passive dosimeters (LiF microcubes and EBT2 radiochromic films) for all beam sizes except the smallest field of 0.6 × 0.6 cm{sup 2} with a deviation of 2.6%. This new study showed the high performance of this diamond detector in small photon beams, in comparison with various commercially available passive and active dosimeters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhancing polarization by electrode-controlled strain relaxation in PbTiO{sub 3} heterostructures

A large remanent polarization close to theoretical value 80 μC/cm{sup 2} of bulk PbTiO{sub 3} is achieved in epitaxial heterostructures of (120–600)-nm-thick PbTiO{sub 3} films grown by pulsed laser deposition on (001) SrTiO{sub 3} substrate using a 100-nm-thick SrRuO{sub 3} bottom electrode layer. The heterostructures employing a 50-nm-thick electrode exhibit a significantly smaller polarization of ≤60 μC/cm{sup 2}. A detailed x-ray diffraction analysis of the crystal structure allows for relating this large polarization to electrode-controlled relaxation of epitaxial strain in PbTiO{sub 3}. Based on the observed results, we anticipate that the electrode-promoted strain relaxation can be used to enhance polarization in other epitaxial ferroelectric films.

36 MATERIALS SCIENCE↗

Transient photoresponse of nitrogen-doped ultrananocrystalline diamond electrodes in saline solution

Beyond conventional electrically-driven neuronal stimulation methods, there is a growing interest in optically-driven approaches. In recent years, nitrogen-doped ultrananocrystalline diamond (N-UNCD) has emerged as a strong material candidate for use in electrically-driven stimulation electrodes. This work investigates the electrochemical activity of N-UNCD in response to pulsed illumination, to assess its potential for use as an optically-driven stimulation electrode. Whilst N-UNCD in the as-grown state exhibits a weak photoresponse, the oxygen plasma treated film exhibits two orders of magnitude enhancement in its sub-bandgap open circuit photovoltage response. The enhancement is attributed to the formation of a dense network of oxygen-terminated diamond nanocrystals at the N-UNCD surface. Electrically connected to the N-UNCD bulk via sub-surface graphitic grain boundaries, these diamond nanocrystals introduce a semiconducting barrier between the sub-surface graphitic semimetal and the electrolyte solution, leading to a photovoltage under irradiation with wavelengths of λ = 450 nm and shorter. Within the safe optical exposure limit of 2 mW mm{sup −2}, charge injection capacity of 0.01 mC cm{sup −2} is achieved using a 15 × 15 μm electrode, meeting the requirements for extracellular and intercellular stimulation. The nanoscale nature of processes presented here along with the diamond's biocompatibility and biostability open an avenue for the use of oxygen treated N-UNCD as optically driven stimulating electrodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Carbon electrode for desalination purpose in capacitive deionization

Carbon electrodes for desalination purpose have been successfully synthesized using activated carbon powder (BET surface area=700 – 1400 m{sup 2}/g), carbon black and polyvinyl alcohol (PVA) binder by cross-linking method with glutaric acid (GA) at 120 °C. The electrochemical properties of the carbon electrodes were analyzed using electrical impedance spectroscopy (EIS) and cyclic voltammetry (CV) whilst the physical properties were observed with scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM/EDX). In order to assess the desalting performance, salt removal experiments were performed by constructing a capacitive deionization unit cell with five pairs of carbon electrodes. For each pair consisted of two parallel carbon electrodes separated by a spacer. Desalination and regeneration processes were also observed in the salt-removal experiments. The salt-removal experiments were carried out in single-pass mode using a solution with 0.1 M NaCl at a flow rate of 10 mL/min. A voltage of 3 V was applied to the cell for 60 minutes for both processes in desalination and regeneration. The result showed that the percentage value of the salt-removal was achieved at 20%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transparent electrodes for high E-field production using a buried indium tin oxide layer

We present a design and characterization of optically transparent electrodes suitable for atomic and molecular physics experiments where high optical access is required. The electrodes can be operated in air at standard atmospheric pressure and do not suffer electrical breakdown even for electric fields far exceeding the dielectric breakdown of air. This is achieved by putting an indium tin oxide coated dielectric substrate inside a stack of dielectric substrates, which prevents ion avalanche resulting from Townsend discharge. With this design, we observe no arcing for fields of up to 120 kV/cm. Using these plates, we directly verify the production of electric fields up to 18 kV/cm inside a quartz vacuum cell by a spectroscopic measurement of the dc Stark shift of the 5{sup 2}S{sub 1/2} → 5{sup 2}P{sub 3/2} transition for a cloud of laser cooled rubidium atoms. We also report on the shielding of the electric field and on the residual electric fields that persist within the vacuum cell once the electrodes are discharged. In addition, we discuss observed atom loss that results from the motion of free charges within the vacuum. The observed asymmetry of these phenomena on the bias of the electrodes suggests that field emission of electrons within the vacuum is primarily responsible for these effects and may indicate a way of mitigating them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

“Virtual IED sensor” at an rf-biased electrode in low-pressure plasma

Energy distribution and the flux of the ions coming on a surface are considered as the key-parameters in anisotropic plasma etching. Since direct ion energy distribution (IED) measurements at the treated surface during plasma processing are often hardly possible, there is an opportunity for virtual ones. This work is devoted to the possibility of such indirect IED and ion flux measurements at an rf-biased electrode in low-pressure rf plasma by using a “virtual IED sensor” which represents “in-situ” IED calculations on the absolute scale in accordance with a plasma sheath model containing a set of measurable external parameters. The “virtual IED sensor” should also involve some external calibration procedure. Applicability and accuracy of the “virtual IED sensor” are validated for a dual-frequency reactive ion etching (RIE) inductively coupled plasma (ICP) reactor with a capacitively coupled rf-biased electrode. The validation is carried out for heavy (Ar) and light (H{sub 2}) gases under different discharge conditions (different ICP powers, rf-bias frequencies, and voltages). An EQP mass-spectrometer and an rf-compensated Langmuir probe (LP) are used to characterize plasma, while an rf-compensated retarded field energy analyzer (RFEA) is applied to measure IED and ion flux at the rf-biased electrode. Besides, the pulsed selfbias method is used as an external calibration procedure for ion flux estimating at the rf-biased electrode. It is shown that pulsed selfbias method allows calibrating the IED absolute scale quite accurately. It is also shown that the “virtual IED sensor” based on the simplest collisionless sheath model allows reproducing well enough the experimental IEDs at the pressures when the sheath thickness s is less than the ion mean free path λ{sub i} (s < λ{sub i}). At higher pressure (when s > λ{sub i}), the difference between calculated and experimental IEDs due to ion collisions in the sheath is observed in the low energy range. The effect of electron impact ionization in the sheath on the origin and intensity of low-energy peaks in IED is discussed compared to ion charge-exchange collisions. Obviously, the extrapolation of the “virtual IED sensor” approach to higher pressures requires developing some other sheath models, taking into account both ion and electron collisions and probably including even a model of the whole plasma volume instead of plasma sheath one.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Less can be more: Insights on the role of electrode microstructure in redox flow batteries from two-dimensional direct numerical simulations

Understanding how to structure a porous electrode to facilitate fluid, mass, and charge transport is key to enhancing the performance of electrochemical devices, such as fuel cells, electrolyzers, and redox flow batteries (RFBs). Here, using a parallel computational framework, direct numerical simulations are carried out on idealized porous electrode microstructures for RFBs. Strategies to improve an electrode design starting from a regular lattice are explored. By introducing vacancies in the ordered arrangement, it is possible to achieve higher voltage efficiency at a given current density, thanks to improved mixing of reactive species, despite reducing the total reactive surface. Careful engineering of the location of vacancies, resulting in a density gradient, outperforms disordered configurations. Our simulation framework is a new tool to explore transport phenomena in RFBs, and our findings suggest new ways to design performant electrodes.

25 ENERGY STORAGE↗

Investigating the Impact of Thickness, Calendering and Channel Structures of Printed Electrodes on the Energy Density of LIBs - 3D Simulation and Validation

Current lithium ion batteries (LIBs) are expensive and bulky, limited by relatively low charging rates. To increase the rate of charging and reduce weight, thin electrodes with high energy density are required. The increase in energy density can be achieved by several techniques including boosting electrolyte transport, high loading/utilization of active material, employing high conductive electrolytes and electrodes with advanced architectures, and increasing cell temperature. In this paper, a 3D physics-based electrochemical model of LIBs is developed in COMSOL simulation software for different thickness, calendering steps as well as channel structures (conical, cylindrical) to optimize the electrode design and in turn maximize volumetric energy density. The simulation results demonstrated that calendering the electrodes with high initial porosity increases the volumetric energy density of the cell. In addition, cylindrical channel structures with relatively lower edge-to-edge distance also results in increased volumetric energy density. The simulation results of the 3D model was validated by comparing it with experimental results.

improving volumetric energy density↗

SU-E-T-414: Experimental Correction of High-Z Electrode Effect in Mini-Ionization Chambers for Small Beam Dosimetry

Purpose: To correct for the over-response of mini-ionization chambers with high-Z central electrodes. The hypothesis is that by applying a negative/reverse voltage, it is possible to suppress the signal generated in the high-Z central electrode by low-energy photons. Methods: The mini-ionization chambers used in the experiments were a PTW-31014, PTW-31006 and IBA-CC01. The PTW-31014 has an aluminum central electrode while the PTW-31006 and IBA-CC01 have a steel one. Total scatter factors (Scp) were measured for a 6 MV photon beam down to a square field size of 0.5 cm. The measurements were performed in water at 10 cm depth with SAD of 100 cm. The Scp were measured with the dosimeters with +400V bias voltage. In the case of the PTW-31006 and IBA-CC01, the measurements were repeated with −400V bias voltage. Also, the field factors in water were calculated with Monte Carlo simulations for comparison. Results: The measured Scp at +400V with the PTW-31006 and IBA-CC01 detectors were in agreement within 0.2% down to a field size of 1.5 cm. Both dosimeters shown a systematic difference about 2.5% with the Scp measured with the PTW-31014 and the Monte Carlo calculated field factors. The measured Scp at −400V with the PTW-31006 and IBA-CC01 detectors were in close agreement with the PTW-31014 measured Scp and the field factors within 0.3 and 1.0%, respectively. In the case of the IBA-CC01 it was found a good agreement (1%) down to field size of 1.0 cm. All the dosimeters shown differences up to 17% between the measured Scp and the field factor for the 0.5 cm field size. Conclusion: By applying a negative/reverse voltage to the mini-ionization chambers with high-Z central electrode it was possible to correct for their over-response to low energy photons.

07 ISOTOPE AND RADIATION SOURCES↗

Influence of the electrode system on the emission characteristics of a vacuum spark

The influence of the electrode system on the emission characteristics of a high-current low-inductance vacuum spark is investigated. It is shown that the structure and composition of the spark plasma radiating in the X-ray spectral range depend substantially on the geometry and relative position of the electrodes. A mechanism related to the effect of the initial distribution of the electric field in the electrode gap is proposed to explain such a dependence. The conditions in which the radiating plasma forms from the erosion products of one or both electrodes are determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of the Heterogeneity of a Mixed-Conducting Electrochemical Electrode

The ionic resistance of membrane–electrode assemblies of oxygen–hydrogen fuel cell electrodes containing platinum nanoparticles on carbon black, carbon nanofibers, and proton-conducting Nafion polymer in a wide range of compositions (10–80 wt %) are studied in situ by the methods of current–voltage characteristics, electrochemical impedance spectroscopy, and simulation of the impedance hodograph. Conditions that make it possible to correctly determine the ionic resistance of the electrode on the basis of an analysis of the linear approximation of the high-frequency region of the impedance hodograph are found. It is shown that the occurrence of inhomogeneities and an anomalous increase in the ionic resistance with an increase in the content of Nafion in the electrode are associated with a decrease in the volume fraction of water-generation centers (particles of electrochemically active platinum), which leads to incomplete wetting of Nafion.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Optimization of Air Electrode for Li/Air Batteries

The effects of carbon microstructure and carbon loading on the performance of Li/air batteries were investigated. The active carbons from various sources were compared, and a dry rolling method was optimized to prepare air electrodes with high mesopore volume. It is found that the capacities of air electrodes improve significantly when the mesopore volume of the carbon source is high. However, for carbons with low mesopore volumes, other factors such as surface activity also play an important role in determining the electrochemical performances of the Li/air batteries. A practical criterion, area-specific capacity, was used to optimize the carbon loading for air electrode. The best area-specific capacity of 13.1 mAh/cm2 was obtained at a carbon loading of 15.1 mg/cm2. Further increasing or decreasing the carbon loading led to a reduced area- specific capacity. Finally, at fixed carbon loading and discharge rates, electrolyte amount was another key factor governing cell performance. A spring mechanism is proposed to explain the formation of the tri-phase regions in air electrodes. After optimizing the parameters listed above, a high capacity of 1,756 mAh/g carbon corresponding to a specific energy of 4,614 Wh/kg carbon was obtained for Li/air batteries operated in a dry air environment.

25 ENERGY STORAGE↗

Modeling the Electrochemistry of an SOFC through the Electrodes and Electrolyte

This paper describes a distributed electrochemistry model of the solid oxide fuel cell (SOFC) electrodes and electrolyte. The distributed electrochemistry (DEC) model solves the transport, reactions, and electric potential through the thickness of the SOFC electrodes. The DEC model allows the local conditions within the electrodes to be studied and allows for a better understanding of how electrochemical and microstructural parameters affect the electrodes. In this paper the governing equations and implementation of the DEC model are presented along with several case studies which are used to investigate the sensitivity of the cathode to the microstructural and electrochemical parameters of the model and to explore methods of improving the electrochemical performance of the SOFC cathode.

30 DIRECT ENERGY CONVERSION↗

Operando Topography and Mechanical Property Mapping of CO 2 Reduction Gas-Diffusion Electrodes Operating at High Current Densities

Electrochemical atomic force microscopy (EC-AFM) enables measurement of electrode topography and mechanical properties during electrochemical reactions. However, for aqueous-based reactions that make gas products, such as CO 2 reduction and water splitting into CO/H 2 , current densities below 1 mA cm −2 have been necessary to prevent formation of bubbles at the electrode; such bubbles can stick to the AFM probe and prevent further AFM imaging. Here, we demonstrate a novel cell design with a gas-diffusion electrode (GDE) to exhaust the gas products, thereby enabling high current density EC-AFM measurements at 1, 10, and 100 mA cm −2 that are not disturbed by bubble formation at the electrode surface. These experiments revealed a stable morphological structure of Cu catalysts deposited on GDEs during high current density operation. Systematic spatially resolved maps of deformation and adhesion showed no signs of a gas-liquid interface between catalyst particles of the GDE.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantifying the Impact of Charge Rate and Number of Cycles on Structural Degeneration of Li-Ion Battery Electrodes

A quantitative link between crack evolution in lithium-ion positive electrodes and the degrading performance on cells is not yet well established nor is any single technique capable of doing so widely available. Here, we demonstrate a widely accessible high-throughput approach to quantifying crack evolution within electrodes. The approach applies super-resolution scanning electron microscopy (SEM) imaging of cross-sectioned NMC532 electrodes, followed by segmentation and quantification of crack features. Crack properties such as crack intensity, crack width and length are quantified as a function of charge rate (1C, 6C, and 9C) and cycle number (25, 225, and 600 cycles). Hundreds of particles are characterized for statistical confidence in the quantitative crack measurements. The data on crack evolution is compared to electrochemical data from full cells and half cells with the NMC532 positive electrodes. We show that while crack evolution strongly correlates with capacity fade in the first 25 cycles, it does not correlate well for the following hundreds of cycles indicating that cracking may not be the dominant cause of capacity fade throughout the cycle-life of cells.

25 ENERGY STORAGE↗

Identifying Critical Electrode Metrics for Efficient, Selective CO 2 Electrochemical Conversion

Low-temperature electrochemical CO 2 reduction (CO 2 R) in zero-gap membrane electrode assembly (MEA) reactors presents a scalable route to fuels and carbon utilization. However, performance at industrially relevant current densities hinges on mesoscale catalyst layer integration, particularly at the ionomer|catalyst interface. Here, we demonstrate a generalizable in situ electrochemical impedance spectroscopy (EIS) method. We utilize this technique to decouple electrode-level parameters that are correlated to the overall MEA performance. By performing this ex situ EIS method on CO 2 -to-CO catalyst-coated membranes with systematically varied ionomer-to-catalyst (I:C) ratios, we reveal a pronounced dependence of performance, ion transport resistance, and catalyst utilization on the I:C ratio as well as the electrode conditioning. We demonstrate that an optimal I:C ratio exists at which ion transport resistance is minimized and Faradaic efficiency for CO production is maximized. Beyond the electrodes examined, here we compare ion transport resistance to MEA selectivity/Faradaic efficiency obtained in prior studies, revealing a clear correlation between the two. These results suggest that ion transport resistance within the catalyst layer may be a quantitative predictor of MEA performance which underscores the importance of mesoscale integration in achieving scalable CO 2 R technologies.

08 HYDROGEN↗

Layered oxide, graphite and silicon-graphite electrodes for Lithium-ion cells: Effect of electrolyte composition and cycling windows

The electrochemical performance of cells with a Li 1.03 (Ni 0.5 Co 0.2 Mn 0.3 ) 0.97 O 2 (NCM523) positive electrode and a blended silicon-graphite (Si-Gr) negative electrode are investigated using various electrolyte compositions and voltage cycling windows. Voltage profiles of the blended Si-Gr electrode show a superposition of graphite potential plateaus on a sloped Si profile with a large potential hysteresis. The effect of this hysteresis is seen in the cell impedance versus voltage data, which are distinctly different for the charge and discharge cycles. We confirm that the addition of compounds, such as vinylene carbonate (VC) and fluoroethylene carbonate (FEC) to the baseline 1.2 M LiPF 6 in ethylene carbonate (EC): ethyl methyl carbonate (EMC) (3:7 w/w) electrolyte, improves cell capacity retention with higher retention seen at higher additive contents. We show that reducing the lower cutoff voltage (LCV) of full cells to 2.5 V increases the Si-Gr electrode potential to 1.12 V vs. Li/Li + ; this relatively-high delithiation potential correlates with the lower capacity retention displayed by the cell. Hence, we show that raising the upper cutoff voltage (UCV) can increase cell energy density without significantly altering capacity retention over 100 charge discharge cycles.

25 ENERGY STORAGE↗