Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diffraction optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

MAGELLAN: High resolution spectroscopy at FUV and EUV wavelengths

The aim of ESA's MAGELLAN mission is to provide high resolution spectra of celestial sources down to sixteenth magnitude over the extreme ultraviolet wavelength range (between 50 and 140 nm). This range extends from studies of interstellar matter in the disc and halo of this and other galaxies, to stellar envelopes, hot and evolved stars, clusters, intergalactic matter, nuclei of galaxies, quasars, and, finally, planets and satellites. The instrument has a nonconventional optical design using only one reflecting surface; a high groove density concave grating collects the star light, diffracts it and focuses its spectrum into a bidimensional windowless detector operated in a photon counting mode. The slitless configuration provides the spectra of all the sources (point like and extended) in the field of view of the grating. This field of view is limited by a grid collimator to reduce the diffuse background, the stray light and the probability of overlapping spectra in crowded fields.

Grewing, M.↗

Micas in experimentally shocked gneiss

Powder-propellant guns are used to shock biotites and muscovites from a gneiss at pressures between 18 and 70 GPa. It is shown that shock in biotite and muscovite can produce homogeneous and devolatilized glasses within microseconds. Shock-deformed micas are found to exhibit fracturing, kinking, and complex extinction patterns over the entire pressure range investigated. Localized melting of micas commences at 33 GPa and reaches completion at 70 GPa. Even though melted biotite and muscovite are opaque optically, they exhibit extensive microvesiculation and flow when observed with the SEM. It is confirmed through electron diffraction that biotite and muscovite have transformed to a glass. The distribution of vesicles in shock-vitrified mica reveals escape of volatiles within the short duration of the shock experiment. It is noted that experimentally shocked biotite and muscovite undergo congruent melting. It is noted that the compositions of the glasses are similar to the unshocked micas except for volatiles (H2O loss and and K loss). These unusual glasses produced from mica can be quenched by rapid cooling conditions during the shock experiment. On the basis of the results, it is pointed out that the extremely low H2O content of tektites can be reconciled with a terrestrial origin by impact.

Lambert, P.↗

White light sunspot observations from the Solar Optical Universal Polarimeter on Spacelab-2

The flight of the Solar Optical Universal Polarimeter on Spacelab-2 provided the opportunity for the collection of time sequences of diffraction-limited (0.5 arcsec) solar images with excellent pointing stability (0.003 arcsec) and with freedom from the distortion that plagues ground-based images. A series of white-light images of active region 4682 were obtained on August 5, 1985, and the area containing the sunspot has been analyzed. These data have been digitally processed to remove noise and to separate waves from low-velocity material motions. The results include: (1) proper motion measurements of a radial outflow in the photospheric granulation pattern just outside the penumbra; (2) discovery of occasional bright structures ('streakers') that appear to be ejected outward from the penumbra; (3) broad dark 'clouds' moving outward in the penumbra, in addition to the well-known bright penumbral grains moving inward; (4) apparent extensions and contractions of penumbral filaments over the photosphere; and (5) observation of a faint bubble or looplike structure that seems to expand from two bright penumbral filaments into the photosphere.

Shine, R. A.↗

Integrated Grating Spectrometer

Proposed integrated grating spectrometer made in waveguide layer on silicon wafer. Occupies area of about 2 centimeters to 2nd power on wafer 0.4 mm thick. Operates in visible spectrum (wavelengths of 400 to 700 nm) and blazed to diffract in first order. Array of integrated grating spectrometers performs spectral analysis of picture elements along line. Optical fiber couples light from each picture element into separate integrated spectrometer. Technique enables continous independent variation, along grating, of pitch, curvature, and blaze angle. Grating designed to have large numerical aperture, zero aberration at two selected wavelengths, and very low aberration at intermediate wavelengths.

Lang, Robert J.↗

Measuring Monodisperse Small Particles En Masse

New optical method enables determination of sizes of approximately-micron-sized particles. Arrays of particles act as diffraction gratings. Simple and inexpensive apparatus replaces high-magnification microscopes in measurements of diameters of small polystyrene latex spheres. Device being used to determine monodispersity and diameters of polystyrene latex microspheres used as seeding material for laser-velocimetry flow measurements in NASA's wind tunnels. Characterization of particle sizes important in wide range of fields, including manufacture of plastics and ceramics, biochemistry, and medicine.

Bruce, Robert A.↗

Research and test facilities for development of technologies and experiments with commercial applications

One of NASA'S agency-wide goals is the commercial development of space. To further this goal NASA is implementing a policy whereby U.S. firms are encouraged to utilize NASA facilities to develop and test concepts having commercial potential. Goddard, in keeping with this policy, will make the facilities and capabilities described in this document available to private entities at a reduced cost and on a noninterference basis with internal NASA programs. Some of these facilities include: (1) the Vibration Test Facility; (2) the Battery Test Facility; (3) the Large Area Pulsed Solar Simulator Facility; (4) the High Voltage Testing Facility; (5) the Magnetic Field Component Test Facility; (6) the Spacecraft Magnetic Test Facility; (7) the High Capacity Centrifuge Facility; (8) the Acoustic Test Facility; (9) the Electromagnetic Interference Test Facility; (10) the Space Simulation Test Facility; (11) the Static/Dynamic Balance Facility; (12) the High Speed Centrifuge Facility; (13) the Optical Thin Film Deposition Facility; (14) the Gold Plating Facility; (15) the Paint Formulation and Application Laboratory; (16) the Propulsion Research Laboratory; (17) the Wallops Range Facility; (18) the Optical Instrument Assembly and Test Facility; (19) the Massively Parallel Processor Facility; (20) the X-Ray Diffraction and Scanning Auger Microscopy/Spectroscopy Laboratory; (21) the Parts Analysis Laboratory; (22) the Radiation Test Facility; (23) the Ainsworth Vacuum Balance Facility; (24) the Metallography Laboratory; (25) the Scanning Electron Microscope Laboratory; (26) the Organic Analysis Laboratory; (27) the Outgassing Test Facility; and (28) the Fatigue, Fracture Mechanics and Mechanical Testing Laboratory.

Source record↗

A 58 x 62 pixel Si:Ga array camera for 5 - 14 micron astronomical imaging

A new infrared array camera system has been successfully applied to high background 5 - 14 micron astronomical imaging photometry observations, using a hybrid 58 x 62 pixel Si:Ga array detector. The off-axis reflective optical design incorporating a parabolic camera mirror, circular variable filter wheel, and cold aperture stop produces diffraction-limited images with negligible spatial distortion and minimum thermal background loading. The camera electronic system architecture is divided into three subsystems: (1) high-speed analog front end, including 2-channel preamp module, array address timing generator, bias power suppies, (2) two 16 bit, 3 microsec per conversion A/D converters interfaced to an arithmetic array processor, and (3) an LSI 11/73 camera control and data analysis computer. The background-limited observational noise performance of the camera at the NASA/IRTF telescope is NEFD (1 sigma) = 0.05 Jy/pixel min exp 1/2.

Gezari, D. Y.↗

The 4-meter lunar engineering telescope

The 16-meter diffraction limited lunar telescope incorporates a primary mirror with 312 one-meter segments; 3 nanometer active optics surface control with laser metrology and hexapod positioners; a space frame structure with one-millimeter stability; and a hexapod mount for pointing. The design data needed to limit risk in this development can be obtained by building a smaller engineering telescope on the moon with all of the features of the 16-meter design. This paper presents a 4.33-meter engineering telescope concept developed by the Summer 1990 Student Program of the NASA/JHU Space Grant Consortium Lunar Telescope Project. The primary mirror, made up of 18 one-meter hexagonal segments, is sized to provide interesting science as well as engineering data. The optics are configured as a Ritchey-Chretien with a coude relay to the focal plane beneath the surface. The optical path is continuously monitored with 3-nanometer precision interferometrically. An active optics processor and piezoelectric actuators operate to maintain the end-to-end optical configuration established by wave front sensing using a guide star. The mirror segments, consisting of a one-centimeter thick faceplate on 30-cm deep ribs, maintain the surface figure to a few nanometers under lunar gravity and thermal environment.

Peacock, Keith↗

Numerical sensitivity analysis of passive EHF and SMMW channels to tropospheric water vapor, clouds, and precipitation

Potential uses of specific extremely High Frequency (EHF) and Sub-Millimeter-Wave (SMMW) channels at 90, 166, 183, 220, 325, 340, and 410 GHz for passive spaceborne remote sensing of the troposphere and lower stratosphere are investigated using an iterative numerical radiative transfer model. Collectively, these channels offer potential for high spatial resolution imaging using diffraction-limited apertures of practical size, along with the ability to profile water vapor, map precipitation beneath optically opaque cloud cover, and to measure nonprecipitating cloud (e.g., cirrus) parameters. A widely-spaced set of EHF and SMMW channels can yield observable degrees of freedom related to clouds and precipitation not available by exclusively using the more thoroughly studied microwave channels below 183 GHz. A new passive airborne imaging instrument for tropospheric meteorological sensing is described.

Gasiewski, A. J.↗

Planetary Remote Sensing Science Enabled by MIDAS (Multiple Instrument Distributed Aperture Sensor)

The science capabilities and features of an innovative and revolutionary approach to remote sensing imaging systems, aimed at increasing the return on future space science missions many fold, are described. Our concept, called Multiple Instrument Distributed Aperture Sensor (MIDAS), provides a large-aperture, wide-field, diffraction-limited telescope at a fraction of the cost, mass and volume of conventional telescopes, by integrating optical interferometry technologies into a mature multiple aperture array concept that addresses one of the highest needs for advancing future planetary science remote sensing.

Pitman, Joe↗

Adventures in Classical PSF Subtraction

Circumstellar Disks, exoplanets, stellar companions are often inconveniently close to a bright object (host star). Exposing sufficiently deeply to detect the object of interest can mean that you overexpose the instrument you are using and swamp the signal of interest. This talk will focus on using a simple coronagraph, and how best to separate the signal of interest from light from the star Optical systems, and HST is no exception, typically spread the light from an unresolved source due to diffraction, scattering in the telescope, and in the science instrument, and in some cases within the detector system. This is termed the point spread function (PSF). For the majority of circumstellar disks and exoplanets signal in the wings of the PSF signal of interest. Simplest of the techniques that will be covered in this hands-on demonstrationUse a suitably chosen other observation as an estimate of the light from the star that you want to get rid of. Need to match the science observation in terms of factors affecting the shape of the PSF, and those affecting temporal variation in the measured PSF.

coronagraph↗

The Hyperspectral Thermal Emission Spectrometer (HyTES): Preliminary Results

The Hyperspectral Thermal Emission Spectrometer (HyTES) is being developed as part of the risk reduction activities associated with the Hyperspectral Infrared Imager (HyspIRI). HyspIRI is one of the Tier 2 Decadal Survey Missions. HyTES will provide information on how to place the filters on the HyspIRI Thermal Infrared Instrument (TIR) as well as provide antecedent science data. The pushbroom design has 512 spatial pixels over a 50-degree field of view and 256 spectral channels between 7.5 micrometers to 12 micrometers. HyTES includes many key enabling state-of-the-art technologies including a high performance convex diffraction grating, a quantum well infrared photodetector (QWIP) focal plane array, and a compact Dyson-inspired optical design. The Dyson optical design allows for a very compact and optically fast system (F/1.6). It also minimizes cooling requirements due to the fact it has a single monolithic prism-like grating design which allows baffling for stray light suppression. The monolithic configuration eases mechanical tolerancing requirements which are a concern since the complete optical assembly is operated at cryogenic temperatures ((is) approximately 100K). The QWIP allows for optimum spatial and spectral uniformity and provides adequate responsivity or D-star to allow 200mK noise equivalent temperature difference (NEDT) operation across the LWIR passband. Assembly of the system is nearly complete. After completion, alignment results will be presented which show low keystone and smile distortion. This is required to minimize spatial-spectral mixing between adjacent spectral channels and spatial positions. Predictions show the system will have adequate signal to noise for laboratory calibration targets.

Moon Mineralogical Mapper (M3).↗

Deep learning of structural morphology imaged by scanning X-ray diffraction microscopy

Scanning X-ray nanodiffraction microscopy is a powerful technique for spatially resolving nanoscale structural morphologies by diffraction contrast. One of the critical challenges in experimental nanodiffraction data analysis is posed by the convergence angle of nanoscale focusing optics which creates simultaneous dependency of the far-field scattering data on three independent components of the local strain tensor-corresponding to dilation and two potential rigid body rotations of the unit cell. All three components are in principle resolvable through a spatially mapped sample tilt series; however, traditional data analysis is computationally expensive and prone to artifacts. In this study, we implement NanobeamNN, a convolutional neural network specifically tailored to the analysis of scanning probe X-ray microscopy data. NanobeamNN learns lattice strain and rotation angles from simulated diffraction of a focused X-ray nanobeam by an epitaxial thin film and can directly make reasonable predictions on experimental data without the need for additional fine-tuning. We demonstrate that this approach represents a significant advancement in computational speed over conventional methods, as well as a potential improvement in accuracy over the current standard.

Luo, Aileen [Cornell Univ., Ithaca, NY (United Sta↗

X-ray diffraction measurements and pressure determination in nanosecond compression of solids up to 600 GPa

X-ray diffraction measurements under laser-driven dynamic compression now allow us to investigate the atomic structure of matter at TPa pressures and thousands of degree temperatures with broad implications for condensed matter physics, planetary science and astronomy. Furthermore, pressure determination in these experiments often relies on velocimetry measurements coupled with modeling that requires accurate knowledge of the optical and thermo-mechanical properties of a window material, resulting in significant systematic uncertainty. Here we demonstrate different approach applicable to X-ray diffraction experiments under quasi-isentropic ramp-compression based on the use of in-situ pressure calibrants, similar to the methods often adopted in static-compression experiments with diamond anvil cells. Focusing on experiments using a diamond window, we discuss challenges and mitigation strategies for the novel approach. Our study, in addition to providing new structural information of 5 metals up to hundreds of GPa, provides validation to the currently used methods based on time-resolved measurement of the diamond free-surface velocity, and reveals that the use of in-situ calibrants enables a factor of four reduction in the pressure uncertainty in these experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stabilized Synthesis of 2D Verbeekite: Monoclinic PdSe 2 Crystals with High Mobility and In-Plane Optical and Electrical Anisotropy

PdSe 2 has a layered structure with an unusual, puckered Cairo pentagonal tiling. Its atomic bond configuration features planar 4-fold-coordinated Pd atoms and intralayer Se–Se bonds that enable polymorphic phases with distinct electronic and quantum properties, especially when atomically thin. PdSe 2 is conventionally orthorhombic, and direct synthesis of its metastable polymorphic phases is still a challenge. Here, we report an ambient-pressure chemical vapor deposition approach to synthesize metastable monoclinic PdSe 2 . Monoclinic PdSe 2 is shown to be synthesized selectively under Se-deficient conditions that induce Se vacancies. These defects are shown by first-principles density functional theory calculations to reduce the free energy of the metastable monoclinic phase, thereby stabilizing it during synthesis. Further, the structure and composition of the monoclinic PdSe 2 crystals are identified and characterized by scanning transmission electron microscopy imaging, convergent beam electron diffraction, and electron energy loss spectroscopy. Polarized Raman spectroscopy of the monoclinic PdSe 2 flakes reveals their strong in-plane optical anisotropy. Electrical transport measurements show that the monoclinic PdSe 2 exhibits n-type charge carrier conduction with electron mobilities up to ~298 cm 2 V –1 s –1 and a strong in-plane electron mobility anisotropy of ~1.9. The defect-mediated growth pathway identified in this work is promising for phase-selective direct synthesis of other 2D transition metal dichalcogenides.

2D material↗

Optical systems integrated modeling

An integrated modeling capability that provides the tools by which entire optical systems and instruments can be simulated and optimized is a key technology development, applicable to all mission classes, especially astrophysics. Many of the future missions require optical systems that are physically much larger than anything flown before and yet must retain the characteristic sub-micron diffraction limited wavefront accuracy of their smaller precursors. It is no longer feasible to follow the path of 'cut and test' development; the sheer scale of these systems precludes many of the older techniques that rely upon ground evaluation of full size engineering units. The ability to accurately model (by computer) and optimize the entire flight system's integrated structural, thermal, and dynamic characteristics is essential. Two distinct integrated modeling capabilities are required. These are an initial design capability and a detailed design and optimization system. The content of an initial design package is shown. It would be a modular, workstation based code which allows preliminary integrated system analysis and trade studies to be carried out quickly by a single engineer or a small design team. A simple concept for a detailed design and optimization system is shown. This is a linkage of interface architecture that allows efficient interchange of information between existing large specialized optical, control, thermal, and structural design codes. The computing environment would be a network of large mainframe machines and its users would be project level design teams. More advanced concepts for detailed design systems would support interaction between modules and automated optimization of the entire system. Technology assessment and development plans for integrated package for initial design, interface development for detailed optimization, validation, and modeling research are presented.

Shannon, Robert R.↗

Measurement bias in self-heating x-ray free electron laser experiments from diffraction studies of phase transformation in titanium

X-ray self-heating is a common by-product of X-ray Free Electron Laser (XFEL) techniques that can affect targets, optics, and other irradiated materials. Diagnosis of heating and induced changes in samples may be performed using the x-ray beam itself as a probe. However, the relationship between conditions created by and inferred from x-ray irradiation is unclear and may be highly dependent on the material system under consideration. Here, we report on a simple case study of a titanium foil irradiated, heated, and probed by a MHz XFEL pulse train at 18.1 keV delivered by the European XFEL using measured x-ray diffraction to determine temperature and finite element analysis to interpret the experimental data. We find a complex relationship between apparent temperatures and sample temperature distributions that must be accounted for to adequately interpret the data, including beam averaging effects, multivalued temperatures due to sample phase transitions, and jumps and gaps in the observable temperature near phase transformations. The results have implications for studies employing x-ray probing of systems with large temperature gradients, particularly where these gradients are produced by the beam itself. Finally, this study shows the potential complexity of studying nonlinear sample behavior, such as phase transformations, where biasing effects of temperature gradients can become paramount, precluding clear observation of true transformation conditions.

Crystallography↗

Temporally continuous thermofluidic–thermomechanical modeling framework for metal additive manufacturing

Additive manufacturing (AM) is known to generate large magnitudes of residual stresses (RS) within builds due to steep and localized thermal gradients. In the current state of commercial AM technology, manufacturers generally perform heat treatments in effort to reduce the generated RS and its detrimental effects on part distortion and in-service failure. Computational models that effectively simulate the deposition process can provide valuable insights to improve RS distributions. Accordingly, it is common to employ Computational fluid dynamics (CFD) models or finite element (FE) models. While CFD can predict geometric and thermal-fluid behavior, it cannot predict the structural response (e.g., stress–strain) behavior. On the other hand, an FE model can predict mechanical behavior, but it lacks the ability to predict geometric and fluid behavior. Thus, an effectively integrated thermofluidic–thermomechanical modeling framework that exploits the benefits of both techniques while avoiding their respective limitations can offer valuable predictive capability for AM processes. In contrast to previously published efforts, the work herein describes a one-way coupled CFD-FEA framework that abandons major simplifying assumptions, such as geometric steady-state conditions, the absence of material plasticity, and the lack of detailed RS evolution/accumulation during deposition, as well as insufficient validation of results. Here, the presented framework is demonstrated for a directed energy deposition (DED) process, and experiments are performed to validate the predicted geometry and RS profile. Both single- and double-layer stainless steel 316L builds are considered. Geometric data is acquired via 3D optical surface scans and X-ray micro-computed tomography, and residual stress is measured using neutron diffraction (ND). Comparisons between the simulations and measurements reveal that the described CFD-FEA framework is effective in capturing the coupled thermomechanical and thermofluidic behaviors of the DED process. The methodology presented is extensible to other metal AM processes, including power bed fusion and wire-feed-based AM.

42 ENGINEERING↗