Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

LET spectra measurements from the STS-35 CPDs

Linear energy transfer (LET) spectra derived form automated track analysis system (ATAS) track parameter measurements for crew passive dosimeters (CPD's) flown with the astronauts on STS-35 are plotted. The spread between the seven individual spectra is typical of past manual measurements of sets of CPD's. This difference is probably due to the cumulative net shielding variations experienced by the CPD's as the astronauts carrying them went about their activities on the Space Shuttle. The STS-35 mission was launched on Dec. 2, 1990, at 28.5 degrees inclination and 352-km altitude. This is somewhat higher than the nominal 300-km flights and the orbit intersects more of the high intensity trapped proton region in the South Atlantic Anomaly (SAA). However, in comparison with APD spectra measured on earlier lower altitude missions (STS-26, -29, -30, -32), the flux spectra are all roughly comparable. This may be due to the fact that the STS-35 mission took place close to solar maximum (Feb. 1990), or perhaps to shielding differences. The corresponding dose and dose equivalent spectra for this mission are shown. The effect of statistical fluctuations at the higher LET values, where track densities are small, is very noticeable. This results in an increased spread within the dose rate and dose equivalent rate spectra, as compared to the flux spectra. The contribution to dose and dose equivalent per measured track is much greater in the high LET region and the differences, though numerically small, are heavily weighted in the integral spectra. The optimum measurement and characterization of the high LET tails of the spectra represent an important part of the research into plastic nuclear track detector (PNTD) response. The integral flux, dose rate, dose equivalent rate and mission dose equivalent for the seven astronauts are also given.

Source record↗

The continuum spectral characteristics of gamma-ray bursts observed by BATSE

Distributions of the continuum spectral characteristics of 260 bursts in the first Burst And Transient Source Experiement (BATSE) catalog are presented. The data are derived from flux calculated from BATSE Large Area Detector (LAD) four-channel discriminator data. The data are converted from counts to protons using a direct spectral inversion technique to remove the effects of atmospheric scattering and the energy dependence of the detector angular response. Although there are intriguing clusters of bursts in the spectral hardness ratio distributions, no evidence for the presence of distinct burst classes based in spectral hardness ratios alone is found. All subsets of bursts selected for their spectral characteristics in this analysis exhibit spatial distributions consistent with isotropy. The spectral diversity of the burst population appears to be caused largely by the highly variable nature of the burst production mechanisms themselves.

Pendleton, Geoffrey N.↗

Measurements with the Chandra Flight Contamination Monitor

NASA's Chandra X-ray Observatory includes a Flight Contamination Monitor (FCM), a system of 16 radioactive calibration sources mounted to the inside of the Observatory's forward contamination cover. The purpose of the FCM is to verify the ground-to-orbit transfer of the Chandra flux scale, through comparison of data acquired during the ground calibration with those obtained in orbit, immediately prior to opening the Observatory's sun-shade door. Here we report results of these measurements, which place limits on the change in mirror-detector system response and, hence, on any accumulation of molecular contamination on the mirrors' iridium-coated surfaces.

Elsner, R. E.↗

Simulations of a Thin Sampling Calorimeter with GEANT/FLUKA

The Advanced Cosmic-ray Composition Experiment for the Space Station (ACCESS) will investigate the origin, composition and acceleration mechanism of cosmic rays by measuring the elemental composition of the cosmic rays up to 10(exp 15) eV. These measurements will be made with a thin ionization calorimeter and a transition radiation detector. This paper reports studies of a thin sampling calorimeter concept for the ACCESS thin ionization calorimeter. For the past year, a Monte Carlo simulation study of a Thin Sampling Calorimeter (TSC) design has been conducted to predict the detector performance and to design the system for achieving the ACCESS scientific objectives. Simulation results show that the detector energy resolution function resembles a Gaussian distribution and the energy resolution of TSC is about 40%. In addition, simulations of the detector's response to an assumed broken power law cosmic ray spectra in the region where the 'knee' of the cosmic ray spectrum occurs have been conducted and clearly show that a thin sampling calorimeter can provide sufficiently accurate estimates of the spectral parameters to meet the science requirements of ACCESS. n

Lee, Jeongin↗

Measurements with the Chandra X-ray Observatory's Flight Contamination Monitor

NASA's Chandra X-ray Observatory includes a Flight Contamination Monitor (FCM), a system of 16 radioactive calibration sources mounted to the inside of the Observatory's forward contamination cover. The purpose of the FCM is to verify the ground-to-orbit transfer of the Chandra flux scale, through comparison of data acquired during the ground calibration with those obtained in orbit, immediately prior to opening the Observatory's sun-shade door. Here we report results of these measurements., which place limits on the change in the mirror-detector system response and, hence, on any accumulation of molecular contamination on the mirrors' iridium-coated surfaces between the two sets of measurements.

Elsner, R. F.↗

A Compact, Fast, Wide-Field Imaging Spectrometer System

We present test results from a compact, fast (F/1.4) imaging spectrometer system with a 33 degree field of view, operating in the 450-1650 nm wavelength region with an extended response InGaAs detector array. The system incorporates a simple two-mirror telescope and a steeply concave bilinear groove diffraction grating made with gray scale x-ray lithography techniques. High degree of spectral and spatial uniformity (97%) is achieved.

diffraction grating↗

Device and Method of Scintillating Quantum Dots for Radiation Imaging

A radiation imaging device includes a radiation source and a micro structured detector comprising a material defining a surface that faces the radiation source. The material includes a plurality of discreet cavities having openings in the surface. The detector also includes a plurality of quantum dots disclosed in the cavities. The quantum dots are configured to interact with radiation from the radiation source, and to emit visible photons that indicate the presence of radiation. A digital camera and optics may be used to capture images formed by the detector in response to exposure to radiation.

Burke, Eric R.↗

Development of Thin-Window Silicon Drift Detector for X-ray Spectroscopy

A new set of Thin-Window Silicon Drift Detectors composed of an array of hexagonal shaped detectors has been designed, constructed and tested for X-ray spectroscopy. Each individual ThinWinSDD has a thin entrance window on one side and a spiral shaped hexagonal cathode around a center anode on the other side. To produce the thin entrance window a 10 keV implantation of boron through a 500 {angstrom} silicon dioxide was used. The implantation was followed by an annealing at 700 C for 30 min and a reactive ion etching step to ensure the removal of silicon dioxide from the smallest feature (5 {micro}m). An aluminum layer is coated in the same vacuum system after back-sputtering. This step involves removing the native oxide that has formed on the top of the silicon substrate and then sputtering a 1100 {angstrom} thick layer of aluminum onto the X-ray entrance window. The aluminum layer must be thick enough to block visible light, but thin enough to be transparent to soft x-rays down to 280 eV. We discuss first test results that include detector leakage current measurements and the response for multiple detectors exposed to the National Synchrotron Light Source's UV beam line U3C located at Brookhaven National Laboratory for X-ray energies as low as 280 eV.

36 MATERIALS SCIENCE↗

Modeling Passive Fast-Neutron Emission Tomography of Spent Nuclear Fuel

For the past year Oak Ridge National Laboratory has been developing a passive fast-neutron emission tomography capability. Like the passive gamma emission tomography capability presently being evaluated by the International Atomic Energy Agency, the goal of this capability is to detect the removal or substitution of individual fuel pins in spent nuclear fuel assemblies for international safeguards applications, such as verifying the integrity of an assembly before transfer to difficult-to-access storage. The present imaging technique is based on neutron emissions originating primarily from curium-244, which is produced predominantly at the end of the exposure cycle. As a result, this technique may be sensitive not only to fuel pins that are removed or substituted subsequent to all irradiation, but also to fuel pins that are substituted and subsequently irradiated. At present, a laboratory prototype imager is under construction. The purpose of the prototype is to demonstrate an imaging capability sufficient to resolve individual fuel pins using commercially available boron straw detectors that can withstand the high gamma ray dose from a typical spent fuel assembly. To achieve both practical measurement durations and sufficient resolution to discern individual pins, the prototype imager employs a novel collimator design where the slits of a parallel-slit collimator are rearranged to distribute them around a ring surrounding the target fuel assembly. This presentation will report on simulations to understand the neutron signal-to-noise ratio and gamma dose rate as a function of the collimator design, the neutron detector’s response to gamma rays as a function of dose rate, and image reconstruction challenges associated with this collimator design.

Hausladen, Paul↗

On the Ill-Posed Nature of Inverse Problems: An Exactly Solvable Paradigm Inverse Neutron Diffusion Problem Illustrating the Solution's Non-Computability - Paper 48

In general, a physical system and/or the result of an indirect experimental measurement are modeled mathematically in terms of: (a) A system of linear and/or nonlinear equations that relate the system's independent variables and parameters to the system's state (i.e., dependent) variables; (b) Probability distributions, moments thereof, inequality and/or equality constraints that define the range of variations of the system's parameters; (c) One or several quantities, customarily referred to as system responses (or objective functions, or indices of performance), which are computed using the mathematical model. The 'direct problem' solves the 'parameter-to-output' mapping that describes the 'cause-to-effect' relationship in the respective physical process. In practice, the model parameters and/or responses are experimentally measured quantities and are therefore subject to uncertainties. Many measurement problems are 'inverse' to the direct problem in that they seek to determine the properties of the medium (i.e., various cross sections), or the properties of the source, and/or the size of the medium on its boundaries from measurements of quantities that depend on the neutron flux (or from direct measurements of the neutron flux). In general, two problems are called inverses of one another if the formulation of each involves all or part of the solution of the other. Some authors further group such inverse problems into 'invasive', when the interior flux is accessible for measurements as opposed to 'non-invasive', in which only fluxes on the boundary of (or exterior to) the medium can be measured. Examples of inverse radiative transfer problems have been reviewed by McCormick, while examples of inverse source problems for neutron transport have been provided by Sanchez and McCormick. More recently, Bledsoe et al., have presented two methods (the Levenberg-Marquard, and 'differential evolution method') for addressing numerically inverse transport problems. However, although these works (as well as other works cited therein) mentioned the detrimental effects of 'small perturbations in the input data', none of the works published thus far on inverse problems for particle transport or diffusion actually showed explicitly the effects that uncertainties in the measured responses (e.g., detector measurements) would actually have on the 'inverse' deduction (from such measurements) of the underlying medium's properties, sources, etc. This work highlights explicitly the nature of the difficulties encountered in so-called 'inverse problems' by presenting a paradigm inverse neutron diffusion problem admitting an exact solution, in which the 'inverse problem' is to determine the medium's diffusion coefficient from flux measurements. It will be shown explicitly (analytically) that this is not possible to achieve in a unique manner, even in the absence of measurement uncertainties, unless additional error-free information is provided about the quantity to be determined (in this case, the medium's diffusion coefficient). It if further shown that, even if this additional error-free information about the diffusion coefficient to be determined is available, the unavoidable experimental measurements errors, albeit it vanishingly small, in the measured flux render the 'exact solution' useless for computational purposes, since the exact solution turns out to be a divergent series. As discussed in this paper's ENDNOTES section, the paradigm problem presented in this work also underscores the need for 'regularization', which is a qualifier indicating that the inverse problem is to be solved in some approximate manner. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Simulation of the LHC BRAN luminosity monitor for high luminosity interaction regions

The BRAN (Beam RAte of Neutrals) detector monitors the collision rates in the high luminosity interaction regions of LHC (ATLAS and CMS). This Argon gas ionization detector measures the forward neutral particles from collisions at the interaction point. To predict and improve the understanding of the detector's performance, we produced a detailed model of the detector and its surroundings in Fluka. In this paper, we present the model and results of our simulations including the detectors estimated response to interactions for beam energies of 3.5, 5, and 7 TeV.

43 PARTICLE ACCELERATORS↗

Development of Thin-Window Silicon Drift Detector for X-ray Spectroscopy

A new set of thin-window silicon drift detectors composed of an array of hexagonal shaped detectors has been designed, constructed and tested for X-ray spectroscopy. Each individual ThinWinSDD has a thin entrance window on one side and a spiral shaped hexagonal cathode around a center anode on the other side. To produce the thin entrance window a 10 keV implantation of boron through a 500 A silicon dioxide was used. The implantation was followed by an annealing at 700 C for 30 min and a reactive ion etching step to ensure the removal of silicon dioxide from the smallest feature (5 mum). An aluminum layer is coated in the same vacuum system after back-sputtering. This step involves removing the native oxide that has formed on the top of the silicon substrate and then sputtering a 1100 A thick layer of aluminum onto the X-ray entrance window. The aluminum layer must be thick enough to block visible light, but thin enough to be transparent to soft X-rays down to 280 eV. We discuss first test results that include detector leakage current measurements and the response for multiple detectors exposed to the National Synchrotron Light Source's UV beam line U3C located at Brookhaven National Laboratory for X-ray energies as low as 280 eV.

36 MATERIALS SCIENCE↗

High efficiency and rapid response superconducting NbN nanowire single photon detector based on asymmetric split ring metamaterial

With asymmetric split ring metamaterial periodically placed on top of the niobium nitride (NbN) nanowire meander, we theoretically propose a kind of metal-insulator-metallic metamaterial nanocavity to enhance absorbing efficiency and shorten response time of the superconducting NbN nanowire single photon detector (SNSPD) operating at wavelength of 1550 nm. Up to 99.6% of the energy is absorbed and 96.5% dissipated in the nanowire. Meanwhile, taking advantage of this high efficiency absorbing cavity, we implement a more sparse arrangement of the NbN nanowire of the filling factor 0.2, which significantly lessens the nanowire and crucially boosts the response time to be only 40% of reset time in previous evenly spaced meander design. Together with trapped mode resonance, a standing wave oscillation mechanism is presented to explain the high efficiency and broad bandwidth properties. To further demonstrate the advantages of the nanocavity, a four-pixel SNSPD on 10 μm × 10 μm area is designed to further reduce 75% reset time while maintaining 70% absorbing efficiency. Utilizing the asymmetric split ring metamaterial, we show a higher efficiency and more rapid response SNSPD configuration to contribute to the development of single photon detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗