Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Measurement system

A measurement system is described for providing an indication of a varying physical quantity represented by or converted to a variable frequency signal. Timing pulses are obtained marking the duration of a fixed number, or set, of cycles of the sampled signal and these timing pulses are employed to control the period of counting of cycles of a higher fixed and known frequency source. The counts of cycles obtained from the fixed frequency source provide a precise measurement of the average frequency of each set of cycles sampled, and thus successive discrete values of the quantity being measured. The frequency of the known frequency source is made such that each measurement is presented as a direct digital representation of the quantity measured.

Turner, J. W.↗

The graphics and data acquisition software package

A software package was developed for use with micro and minicomputers, particularly the LSI-11/DPD-11 series. The package has a number of Fortran-callable subroutines which perform a variety of frequently needed tasks for biomedical applications. All routines are well documented, flexible, easy to use and modify, and require minimal programmer knowledge of peripheral hardware. The package is also economical of memory and CPU time. A single subroutine call can perform any one of the following functions: (1) plot an array of integer values from sampled A/D data, (2) plot an array of Y values versus an array of X values; (3) draw horizontal and/or vertical grid lines of selectable type; (4) annotate grid lines with user units; (5) get coordinates of user controlled crosshairs from the terminal for interactive graphics; (6) sample any analog channel with program selectable gain; (7) wait a specified time interval, and (8) perform random access I/O of one or more blocks of a sequential disk file. Several miscellaneous functions are also provided.

Crosier, W. G.↗

Degradation of Hubble Space Telescope Metallized Teflon(trademark) FEP Thermal Control Materials

The mechanical and optical properties of the metallized Teflon Fluorinated Ethylene Propylene (FEP) thermal control materials on the Hubble Space Telescope (HST) have degraded over the seven years the telescope has been in orbit. Astronaut observations and photographic documentation from the Second Servicing Mission revealed severe cracks of the multi-layer insulation (MLI) blanket outer layer in many locations around the telescope, particularly on solar facing surfaces. Two samples, the outer Teflon FEP MLI layer and radiator surfaces, were characterized post- mission through exhaustive mechanical, thermal, chemical, and optical testing. The observed damage to the thermal control materials, the sample retrieval and handling, and the significant changes to the radiator surfaces of HST will be discussed. Each of these issues is addressed with respect to current and future mission requirements.

Hansen, Patricia A.↗

Thermal Analysis Of Reluctant Glass Formers

Thermocouple holds sample and monitors temperature during cooling. Ellipsoidal furnace provides controlled cooling rates for studies of thermal properties of reluctant glass formers. Glass tube inserted into furnace and used to blow helium on specimen to cool rapidly. Cooling curve analyzed to determine rate of cooling and such properties of sample as nucleation and recalescence temperatures at cooling rate. Continuous-cooling-crystallization boundaries determined empirically from plots of nucleation time vs. nucleation temperature from runs at large number of different rates of cooling. Apparatus used to examine glass-formation ability of material and critical cooling rate to form glass.

Ethridge, Edwin C.↗

First Results from a Hardware-in-the-Loop Demonstration of Closed-Loop Autonomous Formation Flying

A closed-loop system for the demonstration of formation flying technologies has been developed at NASA s Goddard Space Flight Center. Making use of a GPS signal simulator with a dual radio frequency outlet, the system includes two GPS space receivers as well as a powerful onboard navigation processor dedicated to the GPS-based guidance, navigation, and control of a satellite formation in real-time. The closed-loop system allows realistic simulations of autonomous formation flying scenarios, enabling research in the fields of tracking and orbit control strategies for a wide range of applications. A sample scenario has been set up where the autonomous transition of a satellite formation from an initial along-track separation of 800 m to a final distance of 100 m has been demonstrated. As a result, a typical control accuracy of about 5 m has been achieved which proves the applicability of autonomous formation flying techniques to formations of satellites as close as 50 m.

Gill, E.↗

A comparison of digital flight control design methods

Many variations in design methods for aircraft digital flight control have been proposed in the literature. In general, the methods fall into two categories: those where the design is done in the continuous domain (or s-plane), and those where the design is done in the discrete domain (or z-plane). This paper evaluates several variations of each category and compares them for various flight control modes of the Langley TCV Boeing 737 aircraft. Design method fidelity is evaluated by examining closed loop root movement and the frequency response of the discretely controlled continuous aircraft. It was found that all methods provided acceptable performance for sample rates greater than 10 cps except the 'uncompensated s-plane design' method which was acceptable above 20 cps. A design procedure based on optimal control methods was proposed that provided the best fidelity at very slow sample rates and required no design iterations for changing sample rates.

Powell, J. D.↗

First results from a laboratory facility for measurement of emission spectra under simulated planetary conditions

We have developed a laboratory spectroscopic facility for the measurement of emission spectra under simulated planetary conditions. Spectral measurements are made from 6 to 13 microns with a scanning grating monochromator equipped with a HgCdTl detector. An environment chamber in service in Hawaii for several years in which we can control the temperature from 77 K to 500 K, the pressure from 10(exp -5) torr to two atmospheres, has been equipped with a 77 K or 273 K cold shield. The shield serves to minimize light reflected off the sample and to aid in development of thermal gradients for obtaining spectra under conditions simulating the thermal environment of airless bodies. Samples are placed in small cups on a temperature controlled substrate allowing measurements of emission due to heating from below by the substrate, or from illumination from a solar simulation source.

Lucey, Paul G.↗

A single-board preprocessor and pulse generator

The Aeronomy Lab. of NOAA has designed and built a single board, programmable radar controller for use with VHF ST (stratosphere troposphere) radars. The controller consists of a coherent integrator preprocessor and a radar pulse generator, both of which are described, as well as interfaces to an antenna beam switch and a receiver bandwidth switch. The controller occupies a single slot in a Data General Nova of Eclipse computer. The integrator and pulse generator take advantage of high density, dual port FIFO chips such as the 512 x 9 Mostek MK 4501. These FIFOs have separate input and output ports and independent read and write cycles with cycle times of less than 200 ns, making them very fast and easy to interface. A simple block diagram of the coherent integrator is shown. The integrator is designed to handle inputs from one receiver (2 channels) with 1 sec sample spacing. The pulse generator is based on controllers designed by R. F. Woodman for the Arecibo and SOUSY radars us a recirculating memory scheme.

Carter, D. A.↗

Adaptive reference voltage generator for firing angle control of line-commutated inverters

A control system for a permanent-magnet motor driven by a multiphase line-commulated inverter is described. It is provided with integrators for integrating the back EMF of each phase of the motor for use in generating system control signals for an inverter gate logic using a sync and firing angle control generator connected to the outputs of the integrators. The firing angle control signals are produced by the control generator by means for combining 120 deg segments of the integrated back EMF signals symmetrical about their maxima into composite positive and negative waveforms, and means for sampling the maxima of each waveform every 120 deg. These samples are then used as positive and negative firing angle control signals. Whereby any change in amplitude of the integrated back EMF signals will not affect a change in the operating power factor of the motor and inverter.

Dolland, C. R.↗

Early Fluid and Protein Shifts in Men During Water Immersion

High precision blood and plasma densitometry was used to measure transvascular fluid shifts during water immersion to the neck. Six men (28-49 years) undertook 30 min of standing immersion in water at 35.0 +/- 0.2 C; immersion was preceded by 30 min control standing in air at 28 +/- 1 C. Blood was sampled from an antecubital catheter for determination of Blood Density (BD), Plasma Density (PD), Haematocrit (Ht), total Plasma Protein Concentration (PPC), and Plasma Albumin Concentration (PAC). Compared to control, significant decreases (p less than 0.01) in all these measures were observed after 20 min immersion. At 30 min, plasma volume had increased by 11.0 +/- 2.8%; the average density of the fluid shifted from extravascular fluid into the vascular compartment was 1006.3 g/l; albumin moved with the fluid and its albumin concentration was about one-third of the plasma protein concentration during early immersion. These calculations are based on the assumption that the F-cell ratio remained unchanged. No changes in erythrocyte water content during immersion were found. Thus, immersion-induced haemodilution is probably accompanied by protein (mainly albumin) augmentation which accompanies the intra-vascular fluid shift.

Hinghofer-Szalkay, H.↗

Observation of an Aligned Gas - Solid "Eutectic" during Controlled Directional Solidification Aboard the International Space Station - Comparison with Ground-based Studies

Direct observation of the controlled melting and solidification of succinonitrile was conducted in the glovebox facility of the International Space Station (ISS). The experimental samples were prepared on ground by filling glass tubes, 1 cm ID and approximately 30 cm in length, with pure succinonitrile (SCN) in an atmosphere of nitrogen at 450 millibar pressure for eventual processing in the Pore Formation and Mobility Investigation (PFMI) apparatus in the glovebox facility (GBX) on board the ISS. Real time visualization during controlled directional melt back of the sample showed nitrogen bubbles emerging from the interface and moving through the liquid up the imposed temperature gradient. Over a period of time these bubbles disappear by dissolving into the melt. Translation is stopped after melting back of about 9 cm of the sample, with an equilibrium solid-liquid interface established. During controlled re-solidification, aligned tubes of gas were seen growing perpendicular to the planar solid/liquid interface, inferring that the nitrogen previously dissolved into the liquid SCN was now coming out at the solid/liquid interface and forming the little studied liquid = solid + gas eutectic-type reaction. The observed structure is evaluated in terms of spacing dimensions, interface undercooling, and mechanisms for spacing adjustments. Finally, the significance of processing in a microgravity environment is ascertained in view of ground-based results.

Grugel, R. N.↗

Knowledge based imaging for terrain analysis

A planetary rover will have various vision based requirements for navigation, terrain characterization, and geological sample analysis. In this paper we describe a knowledge-based controller and sensor development system for terrain analysis. The sensor system consists of a laser ranger and a CCD camera. The controller, under the input of high-level commands, performs such functions as multisensor data gathering, data quality monitoring, and automatic extraction of sample images meeting various criteria. In addition to large scale terrain analysis, the system's ability to extract useful geological information from rock samples is illustrated. Image and data compression strategies are also discussed in light of the requirements of earth bound investigators.

Holben, Rick↗

Robust and real-time control of magnetic bearings for space engines

Currently, NASA Lewis Research Center is developing magnetic bearings for Space Shuttle Main Engine (SSME) turbopumps. The control algorithms which have been used are based on either the proportional-intergral-derivative control (PID) approach or the linear quadratic (LQ) state space approach. These approaches lead to an acceptable performance only when the system model is accurately known, which is seldom true in practice. For example, the rotor eccentricity, which is a major source of vibration at high speeds, cannot be predicted accurately. Furthermore, the dynamics of a rotor shaft, which must be treated as a flexible system to model the elastic rotor shaft, is infinite dimensional in theory and the controller can only be developed on the basis of a finite number of modes. Therefore, the development of the control system is further complicated by the possibility of closed loop system instability because of residual or uncontrolled modes, the so called spillover problem. Consequently, novel control algorithms for magnetic bearings are being developed to be robust to inevitable parametric uncertainties, external disturbances, spillover phenomenon and noise. Also, as pointed out earlier, magnetic bearings must exhibit good performance at a speed over 30,000 rpm. This implies that the sampling period available for the design of a digital control system has to be of the order of 0.5 milli-seconds. Therefore, feedback coefficients and other required controller parameters have to be computed off-line so that the on-line computational burden is extremely small. The development of the robust and real-time control algorithms is based on the sliding mode control theory. In this method, a dynamic system is made to move along a manifold of sliding hyperplanes to the origin of the state space. The number of sliding hyperplanes equals that of actuators. The sliding mode controller has two parts; linear state feedback and nonlinear terms. The nonlinear terms guarantee that the systems would reach the intersection of all sliding hyperplanes and remain on it when bounds on the errors in the system parameters and external disturbances are known. The linear part of the control drives the system to the origin of state space. Another important feature is that the controller parameter can be computed off-line. Consequently, on-line computational burden is small.

Sinha, Alok↗

Improvements to pulsed phase locked loop strain monitor

A pulse phase locked loop system according to the present invention is described. A frequency generator such as a voltage controlled oscillator (VCO) generates an output signal and a reference signal having a frequency equal to that of the output signal. A transmitting gate gates the output frequency signal and this gated signal drives a transmitting transducer which transmits an acoustic wave through a material. A sample/hold samples a signal indicative of the transmitted wave which is received by a receiving transducer. Divide-by-n counters control these gating and sampling functions in response to the reference signal of the frequency generator. Specifically, the output signal is gated at a rate of F/h, wherein F is the frequency of the output signal and h is an integer; and the received signal is sampled at a delay of F/n wherein n is an integer.

Froggatt, Mark E.↗

Pulsed phase locked loop strain monitor

A pulse phase locked loop system according to the present invention is described. A frequency generator such as a voltage controlled oscillator (VCO) generates an output signal and a reference signal having a frequency equal to that of the output signal. A transmitting gate gates the output frequency signal and this gated signal drives a transmitting transducer which transmits an acoustic wave through a material. A sample/hold samples a signal indicative of the transmitted wave which is received by a receiving transducer. Divide-by-n counters control these gating and sampling functions in response to the reference signal of the frequency generator. Specifically, the output signal is gated at a rate of F/h, wherein F is the frequency of the output signal and h is an integer; and the received signal is sampled at a delay of F/n wherein n is an integer.

Froggatt, Mark E.↗

Latent Virus Reactivation in Space Shuttle Astronauts

Latent virus reactivation was measured in 17 astronauts (16 male and 1 female) before, during, and after short-duration Space Shuttle missions. Blood, urine, and saliva samples were collected 2-4 months before launch, 10 days before launch (L-10), 2-3 hours after landing (R+0), 3 days after landing (R+14), and 120 days after landing (R+120). Epstein-Barr virus (EBV) DNA was measured in these samples by quantitative polymerase chain reaction. Varicella-zoster virus (VZV) DNA was measured in the 381 saliva samples and cytomegalovirus (CMV) DNA in the 66 urine samples collected from these subjects. Fourteen astronauts shed EBV DNA in 21% of their saliva samples before, during, and after flight, and 7 astronauts shed VZV in 7.4% of their samples during and after flight. It was interesting that shedding of both EBV and VZV increased during the flight phase relative to before or after flight. In the case of CMV, 32% of urine samples from 8 subjects contained DNA of this virus. In normal healthy control subjects, EBV shedding was found in 3% and VZV and CMV were found in less than 1% of the samples. The circadian rhythm of salivary cortisol measured before, during, and after space flight did not show any significant difference between flight phases. These data show that increased reactivation of latent herpes viruses may be associated with decreased immune system function, which has been reported in earlier studies as well as in these same subjects (data not reported here).

Mehta, S. K.↗

Ethylene monitoring and control system

A system that can accurately monitor and control low concentrations of ethylene gas includes a test chamber configured to receive sample gas potentially containing an ethylene concentration and ozone, a detector configured to receive light produced during a reaction between the ethylene and ozone and to produce signals related thereto, and a computer connected to the detector to process the signals to determine therefrom a value of the concentration of ethylene in the sample gas. The supply for the system can include a four way valve configured to receive pressurized gas at one input and a test chamber. A piston is journaled in the test chamber with a drive end disposed in a drive chamber and a reaction end defining with walls of the test chamber a variable volume reaction chamber. The drive end of the piston is pneumatically connected to two ports of the four way valve to provide motive force to the piston. A manifold is connected to the variable volume reaction chamber, and is configured to receive sample gasses from at least one of a plurality of ports connectable to degreening rooms and to supply the sample gas to the reactive chamber for reaction with ozone. The apparatus can be used to monitor and control the ethylene concentration in multiple degreening rooms.

Nelson, Bruce N.↗