Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computational imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Cric searchable image database as a public platform for conventional pap smear cytology data

Amidst the current health crisis and social distancing, telemedicine has become an important part of mainstream of healthcare, and building and deploying computational tools to support screening more efficiently is an increasing medical priority. The early identification of cervical cancer precursor lesions by Pap smear test can identify candidates for subsequent treatment. However, one of the main challenges is the accuracy of the conventional method, often subject to high rates of false negative. While machine learning has been highlighted to reduce the limitations of the test, the absence of high-quality curated datasets has prevented strategies development to improve cervical cancer screening. The Center for Recognition and Inspection of Cells (CRIC) platform enables the creation of CRIC Cervix collection, currently with 400 images (1,376 × 1,020 pixels) curated from conventional Pap smears, with manual classification of 11,534 cells. This collection has the potential to advance current efforts in training and testing machine learning algorithms for the automation of tasks as part of the cytopathological analysis in the routine work of laboratories.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental study of multiple-orientation muon tomography with image optimization in sparse data environments

Due to the high penetrating power of cosmic-ray muons, they can be used to probe very thick and dense objects. As muons are charged particles, they can be tracked by ionization detectors, determining the position and direction of the muons. With detectors on either side of an object to measure particle direction change, scattering information within the object can be found. This can be used to produce a scattering-intensity image within the object related to density and atomic number. Such imaging is typically performed with a single detector-object orientation, taking advantage of the more intense downward flux of muons, producing planar imaging with some depth-of-field information in the third dimension. Several simulation studies were published with multiorientation tomography, which can form a three-dimensional representation faster than a single-orientation view. In this study, experimental muon-scatter-based tomography was performed using a concrete filled steel drum with several different metal wedges inside, with the drum between detector planes. Data were collected from different detector-object orientations by rotating the steel drum. The data collected from each orientation were combined using two different tomographic methods. A traditional inverse Radon transform approach used for computed tomography and a combination of multiple depth-of-field reconstructions were applied to the data. As cosmic-ray muon flux imaging is rate limited, the imaging techniques were compared for sparse data. Using the combined depth-of-field reconstruction technique, fewer detector-object orientations were needed to reconstruct images that could be used to differentiate the metal wedges.

47 OTHER INSTRUMENTATION↗

Imaging Bragg Edge Analysis TooLs for Engineering Structures (iBeatles)

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) provides pulsed neutrons with energies varying from epithermal to cold. In preparation for VENUS, the neutron imaging beamline to be located at beam port 10, we have performed a series of experiments focused on wavelength-dependent radiography and computed tomography for a broad range of applications, from materials science to biological tissues.One of the time-of-flight (TOF) techniques that is of interest to the scientific community is the 2-dimensional mapping of phases and average crystalline plane orientation in samples both ex-situ and during applied stresses such as tensile loading and heating. This technique is known as Bragg edgeimaging and relies on the identification of changes of transmission values, fitting of the edge to measure its displacement, and thus identify the shift in lattice parameter due to stresses. One of the challenges of TOF imaging measurements is the amount of data and the inability to observe Bragg edge shifts in real time during an experiment. Thus, we have been focusing on creating a Python-based interface that allows fast data processing and instantaneous mapping and fitting of the Bragg edges, and their evolution through time. Python libraries and Jupyter notebooks have been implemented to facilitate decision making during an experiment. The advantage of the notebooks is the possibility to guide an experiment as they can quickly process and display Bragg edge data. These notebooks can be used independently, or can be combined in a Python Graphical User Interface (GUI) tool called iBeatles. This interface permits visualization and fitting of the Bragg edges, and ultimately back-projects the fitting results onto the radiographs to display a strain map. Assuming data collection has sufficient statistics, the strain mapping analysis can be performed on a pixel-by-pixel basis. This development is a step forward toward a better user experience at the future VENUS beamline in terms of live feedback and productivity. Analysis that used to take days of switching between different applications can now be done in minutes within the

Bilheux, JeanChristophe [Oak Ridge National Labora↗

TF9 Dataset Analysis

Incident Overview: In the time between November 2, 2019 and November 11, 2019, WheelByte was plagued by breaches in security. These insecurities led to breaches in customer data, company data, and even the death of an employee, Matthew Swift. They have launched an investigation into the company’s computer systems in hopes to find the root cause. We have been provided with the following artifacts from WheelByte: memory images, disk images, network packet captures, and emails. We have found multiple cyber-system attacks against WheelByte. Our investigation lasted from July 13th - August 3rd, 2023. WheelByte allowed us to look at any and every file, and there were no restrictions on what we could or could not use in our investigation. By the end of our investigation, we have been able to deduce who is behind the attack, what they have done, and why they did it. A company that is closely related to WheelByte is called Slyde. Slyde sells electric scooters and it is known that the Chief Executive Officer (CEO) of Slyde, Kimberly Holmes, sees WheelByte as a threat to business, as Wheelbyte sells electric skateboards. We have been able to deduce that Slyde is likely behind many of the malicious attacks. We have seen exfiltration addresses to Slyde domains, along with other Slyde information within their malware. We can see lots of traffic to and from Slyde Internet Protocol (IP) addresses. This may be an attempt to cripple WheelByte’s productivity to remove Slyde’s competitor from the market.

97 MATHEMATICS AND COMPUTING↗

DeepPatent2: A Large-Scale Benchmarking Corpus for Technical Drawing Understanding

Abstract Recent advances in computer vision (CV) and natural language processing have been driven by exploiting big data on practical applications. However, these research fields are still limited by the sheer volume, versatility, and diversity of the available datasets. CV tasks, such as image captioning, which has primarily been carried out on natural images, still struggle to produce accurate and meaningful captions on sketched images often included in scientific and technical documents. The advancement of other tasks such as 3D reconstruction from 2D images requires larger datasets with multiple viewpoints. We introduce DeepPatent2, a large-scale dataset, providing more than 2.7 million technical drawings with 132,890 object names and 22,394 viewpoints extracted from 14 years of US design patent documents. We demonstrate the usefulness of DeepPatent2 with conceptual captioning. We further provide the potential usefulness of our dataset to facilitate other research areas such as 3D image reconstruction and image retrieval.

97 MATHEMATICS AND COMPUTING↗

Randomized Algorithms for Scientific Computing (RASC)

Randomized algorithms have propelled advances in artificial intelligence (AI) and represent a foundational research area in advancing AI for Science. Future advancements in DOE Office of Science priority areas such as climate science, astrophysics, fusion, advanced materials, combustion, and quantum computing all require randomized algorithms for surmounting challenges of complexity, robustness, and scalability. Advances in data collection and numerical simulation have changed the dynamics of scientific research and motivate the need for randomized algorithms. For instance, advances in imaging technologies such as X-ray ptychography, electron microscopy, electron energy loss spectroscopy, or adaptive optics lattice light-sheet microscopy collect hyperspectral imaging and scattering data in terabytes, at breakneck speed enabled by state-of-the-art detectors. The data collection is exceptionally fast compared with its analysis. Likewise, advances in high-performance architectures have made exascale computing a reality and changed the economies of scientific computing in the process. Floating-point operations that create data are essentially free in comparison with data movement. Thus far, most approaches have focused on creating faster hardware. Ironically, this faster hardware has exacerbated the problem by making data still easier to create. Under such an onslaught, scientists often resort to heuristic deterministic sampling schemes (e.g., low-precision arithmetic, sampling every nth element) and sacrifice potentially valuable accuracy. Dramatically better results can be achieved via randomized algorithms, reducing the data size as much as or more than naive deterministic subsampling can achieve, while retaining the high accuracy of computing on the full data set. By randomized algorithms we mean those algorithms that employ some form of randomness in internal algorithmic decisions to accelerate time to solution, increase scalability, or improve reliability. Examples include matrix sketching for solving large-scale least-squares problems (see Figure 1) and stochastic gradient descent for training machine learning models. We are not recommending heuristic methods but rather randomized algorithms that have certificates of correctness and probabilistic guarantees of optimality and near-optimality. Such approaches can be useful beyond acceleration, for example, in understanding how to avoid measure zero worst-case scenarios that plague methods such as QR matrix factorization.

97 MATHEMATICS AND COMPUTING↗

2.5D Super-Resolution Approaches for X-Ray Computed Tomography-Based Inspection of Additively Manufactured Parts

X-ray computed tomography (XCT) is a key tool in non-destructive evaluation of additively manufactured (AM) parts, allowing for internal inspection and defect detection. Despite its widespread use, obtaining high-resolution CT scans can be extremely time consuming. This issue can be mitigated by performing scans at lower resolutions; however, reducing the resolution compromises spatial detail, limiting the accuracy of defect detection. Super-resolution algorithms offer a promising solution for overcoming resolution limitations in XCT reconstructions of AM parts, enabling more accurate detection of defects. While 2D super-resolution methods have demonstrated state-of-the-art performance on natural images, they tend to under-perform when directly applied to XCT slices. On the other hand, 3D super-resolution methods are computationally expensive, making them infeasible for large-scale applications. To address these challenges, we propose a 2.5D super-resolution approach tailored for XCT of AM parts. Our method enhances the resolution of individual slices by leveraging multi-slice information from neighboring 2D slices without the significant computational overhead of full 3D methods. Specifically, we use neighboring low-resolution slices to super-resolve the center slice, exploiting inter-slice spatial context while maintaining computational efficiency. This approach bridges the gap between 2D and 3D methods, offering a practical solution for high-throughput defect detection in AM parts.

Sullivan, Haley↗

Personalized and uncertainty-aware coronary hemodynamics simulations: From Bayesian estimation to improved multi-fidelity uncertainty quantification

Non-invasive simulations of coronary hemodynamics have improved clinical risk stratification and treatment outcomes for coronary artery disease, compared to relying on anatomical imaging alone. However, simulations typically use empirical approaches to distribute total coronary flow amongst the arteries in the coronary tree, which ignores patient variability, the presence of disease, and other clinical factors. Further, uncertainty in the clinical data often remains unaccounted for in the modeling pipeline. We present an end-to-end uncertainty-aware pipeline to (1) personalize coronary flow simulations by incorporating vessel-specific coronary flows as well as cardiac function; and (2) predict clinical and biomechanical quantities of interest with improved precision, while accounting for uncertainty in the clinical data. We assimilate patient-specific measurements of myocardial blood flow from clinical CT myocardial perfusion imaging to estimate branch-specific coronary artery flows. Simulated noise in the clinical data is used to estimate the joint posterior distributions of the model parameters using adaptive Markov Chain Monte Carlo sampling. Additionally, the posterior predictive distribution for the relevant quantities of interest is determined using a new approach combining multi-fidelity Monte Carlo estimation with non-linear, data-driven dimensionality reduction. This leads to improved correlations between high- and low-fidelity model outputs. Our framework accurately recapitulates clinically measured cardiac function as well as branch-specific coronary flows under measurement noise uncertainty. We observe substantial reductions in confidence intervals for estimated quantities of interest compared to single-fidelity Monte Carlo estimation and state-of-the-art multi-fidelity Monte Carlo methods. This holds especially true for quantities of interest that showed limited correlation between the low- and high-fidelity model predictions. In addition, the proposed multi-fidelity Monte Carlo estimators are significantly cheaper to compute than traditional estimators, under a specified confidence level or variance. The proposed pipeline for personalized and uncertainty-aware predictions of coronary hemodynamics is based on routine clinical measurements and recently developed techniques for CT myocardial perfusion imaging. The proposed pipeline offers significant improvements in precision and reduction in computational cost.

Bayesian parameter estimation↗

Impact of simulated reduced injected dose on the assessment of amyloid PET scans

To investigate the impact of reduced injected doses on the quantitative and qualitative assessment of the amyloid PET tracers [ 18 F]flutemetamol and [ 18 F]florbetaben. Cognitively impaired and unimpaired individuals (N = 250, 36% Aβ-positive) were included and injected with [ 18 F]flutemetamol (N = 175) or [ 18 F]florbetaben (N = 75). PET scans were acquired in list-mode (90–110 min post-injection) and reduced-dose images were simulated to generate images of 75, 50, 25, 12.5 and 5% of the original injected dose. Images were reconstructed using vendor-provided reconstruction tools and visually assessed for Aβ-pathology. SUVRs were calculated for a global cortical and three smaller regions using a cerebellar cortex reference tissue, and Centiloid was computed. Absolute and percentage differences in SUVR and CL were calculated between dose levels, and the ability to discriminate between Aβ- and Aβ + scans was evaluated using ROC analyses. Finally, intra-reader agreement between the reduced dose and 100% images was evaluated. At 5% injected dose, change in SUVR was 3.72% and 3.12%, with absolute change in Centiloid 3.35CL and 4.62CL, for [ 18 F]flutemetamol and [ 18 F]florbetaben, respectively. At 12.5% injected dose, percentage change in SUVR and absolute change in Centiloid were < 1.5%. AUCs for discriminating Aβ- from Aβ + scans were high (AUC ≥ 0.94) across dose levels, and visual assessment showed intra-reader agreement of > 80% for both tracers. This proof-of-concept study showed that for both [ 18 F]flutemetamol and [ 18 F]florbetaben, adequate quantitative and qualitative assessments can be obtained at 12.5% of the original injected dose. However, decisions to reduce the injected dose should be made considering the specific clinical or research circumstances.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hydroscanner: Instrumentation for Water Ingress Imaging in Photovoltaic Module Packaging Materials

A new iteration of the Hydroscanner prototype was designed and built during the execution of the contract. Compared to the previous designs, the communication port was changed from ethernet to USB C, since it provides a more seamless integration as a peripheral unit. An additional advantage is that one single port can be used for both communication and power up of the infrared camera. Although the power requirements are higher than the typical amount provided by a laptop computer, the camera can be run as a peripheral from a docking station when connected to a thunderbolt charging port. The software interface was modified to accommodate two imaging modes, an 8-bit and 14-bit image display. The 8-bit images use a custom colorization scheme that divides all pixels in the image into bins of equal width, such that images containing a wide range of brightness display the intermediate pixel intensities in greyscale values that enhance the contrast. The 14-bit images provide the direct readout from the focal plane array of the camera and can be saved as a text file for later processing in other software packages (MATLAB, Python).

47 OTHER INSTRUMENTATION↗

Deep learning to estimate permeability using geophysical data

Time-lapse electrical resistivity tomography (ERT) is a popular geophysical method to estimate three-dimensional (3D) permeability fields from electrical potential difference measurements. Traditional inversion and data assimilation methods are used to ingest this ERT data into hydrogeophysical models to estimate permeability. Due to ill-posedness and the curse of dimensionality, existing inversion strategies provide poor estimates and low resolution of the 3D permeability field. Recent advances in deep learning provide us with powerful algorithms to overcome this challenge. This paper presents a deep learning (DL) framework to estimate the 3D subsurface permeability from time-lapse ERT data. To test the feasibility of the proposed framework, we train DL-enabled inverse models on simulation data. Each measurement in both synthetic and field data is standardized by removing the mean and scaling the time-series to unit variance. This pre-processing step is necessary to bring simulation data closer to field observations. Subsurface process models based on hydrogeophysics are used to generate this synthetic data. Training performed on limited simulation data resulted in the DL model over-fitting. An advanced data augmentation based on mixup is implemented to generate additional training samples to overcome this issue. This mixup technique creates weakly labeled (low-fidelity) samples from strongly labeled (high-fidelity) data. The weakly labeled training data is then used to develop DL-enabled inverse models and reduce over-fitting. As both time-lapse ERT (1133048 features/realization) and 3D permeability (585453 features/realization) data samples are from a high-dimensional space, principal component analysis (PCA) is employed to reduce dimensionality. Encoded ERT and encoded permeability are generated using the trained PCA estimators. A deep neural network is then trained to map the encoded ERT to encoded permeability. This mixup training and unsupervised learning allowed us to build a fast and reasonably accurate DL-based inverse model under limited simulation data. Results show that proposed weak supervised learning can capture salient spatial features in the 3D permeability field. Quantitatively, the average mean squared error (in terms of the natural log) on the strongly labeled training, validation, and test datasets is less than 0.5. The R 2 -score (global metric) is greater than 0.75, and the percent error in each cell (local metric) is less than 10%. Finally, an added benefit in terms of computational cost is that the proposed DL-based inverse model is at least O(10 4 ) times faster than running a forward model once it is trained. Data generation, DL model training, and hyperparameter tuning to identify optimal neural network architectures utilized high-performance computing resources while the DL inference is performed on a standard laptop. Approximately, O(10 5 ) processor hours are used for generating data and DL tuning and training. We acknowledge that the data generation and DL model development are expensive. But once a DL model is trained, it can be re-used for inversion rapidly for the given system, with set physics and domain. Note that traditional inversion may require multiple forward model simulations (e.g., in the order of 10 to 1000), which are very expensive. This computational savings ≈ O(10 5 ) – O(10 7 )) makes the proposed DL-based inverse model attractive for subsurface imaging and real-time ERT monitoring applications due to fast and yet reasonably accurate estimations of permeability field.

58 GEOSCIENCES↗

Detailed mixing measurements from single-hole converging ECN injectors using Rayleigh scattering

Time resolved liquid and vapor fields of dodecane and oxymethylene ethers are measured from Spray A-3 and Spray D using high speed Rayleigh scattering and diffuse back illumination at the Engine Combustion Network (ECN) Spray A condition of 900 K and 22.8 kg/m 3 . Global quantities including mixture fraction, vapor and liquid penetration, as well as spreading angle are measured. The mixture fraction fields and vapor penetration profiles are well predicted by the 1-D Musculus-Kattke model. The mixture fraction field and vapor penetration from Spray A-3 are similar to those measured from Spray A in previous works. Spray D exhibits higher mixture fraction fields and vapor penetration due to its larger nozzle diameter. The quasi-steady mixture fraction fields from these injectors scale well when distance from the injector is normalized by the nozzle diameter. The turbulent dissipation structures were also analyzed based on the orientation, thickness, and magnitude of the mixing layers. Furthermore, the orientation and thickness are similar to other measurements in atmospheric gas jets, while the magnitude is lower. The thickness and magnitude are subject to uncertainties due to limitations in the imaging resolution of the system but still provide an order of magnitude as a useful reference for comparison against computational fluid dynamic simulations.

33 ADVANCED PROPULSION SYSTEMS↗

Implementation and experimental validation of nonlocal damage in a large-strain elasto-viscoplastic FFT-based framework for predicting ductile fracture in 3D polycrystalline materials

Ductile materials, such as metal alloys, can undergo substantial deformation before failure. Additionally, these materials are usually of polycrystalline composition and exhibit strongly anisotropic behavior at small length scales. Previously developed fast Fourier transform (FFT)-based models can model ductile fracture of isotropic materials or the elastic–plastic behavior of anisotropic polycrystalline materials; however, there remains a need to couple both capabilities. This work extends a large-strain FFT-based crystal plasticity model to simulate ductile fracture of polycrystalline materials. In this work, a triaxiality-based continuum damage mechanics (CDM) formulation is incorporated into a large-strain elasto-viscoplastic FFT (LS-EVPFFT) framework. The CDM formulation is augmented with an integral-based nonlocal regularization approach that correctly handles gas-phase material necessary to model unconstrained surfaces. To validate the damage-enabled LS-EVPFFT framework, mesoscale copper tensile coupons were machined using microwire electrical discharge machining and experimentally characterized using electron backscatter diffraction. In-situ optical digital image correlation was performed during uniaxial testing to provide a side-by-side comparison of the experimental and computational strain fields and stress–strain responses. The damage-enabled LS-EVPFFT framework can simulate the complete macroscopic stress–strain response of ductile polycrystals to failure. The model reproduces necking behavior that qualitatively agrees with experimental observations. By leveraging the relatively low computational cost of the damage-enabled LS-EVPFFT framework, the framework presented here allows the ductile fracture response of 3D polycrystalline materials to be tractably predicted.

36 MATERIALS SCIENCE↗

Quantitative Bioluminescence Tomography-Guided Conformal Irradiation for Preclinical Radiation Research

Widely used cone beam computed tomography (CBCT)-guided irradiators in preclinical radiation research are limited to localize soft tissue target because of low imaging contrast. Knowledge of target volume is a fundamental need for radiation therapy (RT). Without such information to guide radiation, normal tissue can be overirradiated, introducing experimental uncertainties. This led us to develop high-contrast quantitative bioluminescence tomography (QBLT) for guidance. The use of a 3-dimensional bioluminescence signal, related to cell viability, for preclinical radiation research is one step toward biology-guided RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A new paradigm in electron microscopy: Automated microstructure analysis utilizing a dynamic segmentation convolutional neutral network

Over the past half century, the transmission electron microscope enabled insight into the fundamental arrangements and structures of materials. State-of-the-art electron microscopes can acquire large image datasets across multiple imaging modalities. However, the manual annotation process for feature or defect quantification may not be feasible with the modern microscope. Convolutional neural networks emerged to characterize individual microstructural features from an image in a cost-effective, consistent manner. However, many of these neural network approaches rely on thousands to hundreds of thousands of manual annotations of each feature type across hundreds of images to train the network for adequate performance. This work focused on the development and application of a pixel-wise defect detection machine-learning dynamic segmentation convolutional neural network with associated automated acquisition and postprocessing to identify microstructural features rapidly and quantitatively from a small initial dataset incorporating multiple imaging modes. The approach was demonstrated for characterization of superalloy 718 from both single image acquisition on multiple detectors to in-situ evolution captured with a single detector on a standard desktop computer to demonstrate the low barrier to entry required for widespread adoption. Pixel-by-pixel class identification was excellent with strong identification of chemically distinct phases, structurally distinct phases, and defect structures, thus demonstrating the new paradigm of machine learning-assisted characterization.

36 MATERIALS SCIENCE↗

Denoising atomic resolution 4D scanning transmission electron microscopy data with tensor singular value decomposition

Tensor singular value decomposition (SVD) is a method to find a low-dimensional representation of data with meaningful structure in three or more dimensions. Here, tensor SVD has been applied to denoise atomic-resolution 4D scanning transmission electron microscopy (4D STEM) data. On data simulated from a SrTiO 3 [100] perfect crystal and a Si [110] edge dislocation, tensor SVD achieved an average peak signal-to-noise ratio (PSNR) of ~40 dB, which matches or exceeds the performance of other denoising methods, with processing times at least 100 times shorter. On experimental data from SrTiO 3 [100] and LiZnSb [11 2 ¯ 0]/GaSb [110] samples, tensor SVD denoises multiple GB 4D STEM data sets in ten minutes on a typical personal computer. Denoising with tensor SVD improves both convergent beam electron diffraction patterns and virtual-aperture annular dark field images.

36 MATERIALS SCIENCE↗

Transient superconductivity at nano- and meso-scales

High-T c superconductivity is surpassed by few, if any, other unsolved problems in contemporary physics in terms of its richness, complexity, impact on other fields, and potential technological importance in energy applications. Recent discoveries reveal that the highest transition temperatures emerge under extraordinary experimental conditions such as the strong perturbation of a single atomic layer material by the underlying substrate, application of ~200 GPa pressure or ~MV/cm static electric fields, or irradiation by intense femtosecond optical fields. Research in superconductivity under extreme experimental conditions is challenging and requires the development of novel experimental methods and new theoretical tools suitable to tackle the problem. Our team has approached the challenges of transient superconductivity under intense optical fields by rethinking the types of experimental observables that are best suited to elucidate the physics of light-induced effects. This exercise has identified the need for: i) ultra-fast spatio-temporal probes enabling access to plasmonic properties and also nano-scale inhomogeneities that are ubiquitous in unconventional superconductors; ii) meso-scale structures and hybrid meta-surfaces imperative for strong enhancement of optical fields and iii) theoretical approaches suitable to explain and predict the response of superconductors under ultra-fast photo-excitation. Co-PIs have already made major advances with developing capabilities i)-iii). Therefore, our team is poised to make significant progress in transient superconductivity by exploring novel spatio-temporal effects that currently remain unattainable. Co-investigators will search for light-induced superconductivity in the high-T c cuprates to build upon spectacular recent results still lacking independent confirmations. Novel data acquisition methods combined with nano-plasmonic imaging will allow our team to test the hypothesis of photo-induced superconducting pairing. Spatio-temporal experiments will provide insights into the interplay between superconductivity and competing orders in the cuprates. Co-PIs will also investigate strong light-matter interaction and superconductivity in FeSe monolayers. Finally, we will study spatio-temporal electrodynamics of planar Josephson junctions. This latter direction will allow our team to thoroughly characterize one of the most fundamental examples of inhomogeneity in all of unconventional superconductivity. The proposed experiments in combination with theoretical analysis will provide information that is difficult to obtain using alternative methods. Basov and Averitt will carry out pump-probe spectroscopy and nano-imaging experiments. Averitt and Hone will design and fabricate state-of-the-art meta-surfaces. Theoretical and computational studies of ultrafast transient phenomena will be carried out by Millis and Fogler. Modeling of time-resolved nano-optical effects will be done by Fogler. The bulk of the requested budget will be used to support graduate students at Columbia & UCSD that will be co-supervised by co-PIs. The proposed program is transformative, since it will enable an entire suite of experiments previously either impossible or technically implausible. It will deliver critically important insights not only into mechanisms of unconventional superconductivity but also to many other correlated quantum materials.

36 MATERIALS SCIENCE↗

Radioimaging for real-time tracking of high-voltage breakdown

Development of a radioimaging diagnostic for high-voltage component reliability testing and electrical breakdown computational model validation is described. Radioimaging has its roots in radio astronomy, where aperture synthesis (also known as synthesis imaging) has been utilized for decades to image radio sources far from Earth. Radioimaging as described herein, in contrast, seeks to image radio sources in close proximity to its receivers (i.e., in a laboratory environment). Here it is shown that corona discharge, a non-destructive precursor to catastrophic (thermal) arc discharge, electromagnetically radiates strongly within a 250 kHz – 2.5 GHz bandwidth, and is readily detected and located by postprocessing the received radio signals. The ability of radioimaging to detect both corona and arc discharge (grouped together herein as high voltage breakdown or HVB) makes it a valuable tool for 100% HVB detection in materials, components, and devices, and has the ability to indicate electrical weakness (via corona detection) prior to a destructive arc discharge event. Radioimaging enables HVB to be located both internal and external to dielectric components under test in near-real-time, with multiple and/or extended HVB events located simultaneously. In contrast, existing non-destructive diagnostics (at the time of this writing) either indicate electrical breakdown without resolving failure locations (e.g., current, voltage, and chemical measurements), locate external HVB (e.g., high-speed optical and ultraviolet (UV) measurements or photography), or locate both external and internal HVB but with low fidelity (e.g., a single HVB source can be located by existing time-of-arrival (TOA) UHF or acoustic emissions). Radioimaging instead creates a sequence of high-fidelity images similar to an optical high-speed camera but at radiofrequencies (RF), and is not limited to two-dimensions. Moreover, radioimaging has already served one internal and two external industry customers, the results of which are detailed in this report. The radioimaging results described herein were part of a three-year effort funded by the Sandia Lab Directed Research and Development (LDRD) program within the Radiation, Electromagnetic, High Energy Density Science (REHEDS) investment area.

47 OTHER INSTRUMENTATION↗