Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compact”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Physics-Based Compact Model for CIGS and CdTe Solar Cells: From Voltage-Dependent Carrier Collection to Light-Enhanced Reverse Breakdown: Preprint

In this paper, we develop a physics-based compact model for copper indium gallium diselenide (CIGS) and cadmium telluride (CdTe) heterojunction solar cells that attributes the failure of superposition to voltage-dependent carrier collection in the absorber layer, and interprets light-enhanced reverse breakdown as a consequence of tunneling-assisted Poole-Frenkel conduction. The temperature dependence of the model is validated against both simulation and experimental data for the entire range of bias conditions. The model can be used to characterize device parameters, optimize new designs, and most importantly, predict performance and reliability of solar panels including the effects of self-heating and reverse breakdown due to partial-shading degradation.

14 SOLAR ENERGY↗

Design and Integration of a Compact Mobile Outdoor Soil Sampling Agricultural Robot

The lack of feedback on soil management for crop systems necessitates the collection of soil samples to derive insights into prevailing soil conditions. Achieving an accurate model of these plantations requires a substantial number of soil samples, which is a labor-intensive process that can suffer from inconsistencies in both the methodology of collection and the locations from which samples are gathered. In addition, the close spacing of crop rows constrains the maneuverability of mobile agricultural equipment during sample collection. This article proposes the use of agricultural robotics to facilitate the acquisition of composite soil samples with minimal human intervention, allowing for precise data collection for a Populus plant system. More specifically, this article presents a case study on the design and construction of a compact agricultural robot for soil sample collection. The performance of the robot, including its soil collection efficacy, maneuverability, and positional accuracy, is evaluated.

42 ENGINEERING↗

A Low Loss, Fast Ramp HTS Solenoid Prototype for Compact Spherical Tokamaks

To explore AC loss characteristics of commercial Bi-2212 conductors made in the USA, a small ohmic heating (OH) prototype coil is being developed for compact tokamaks using high performance Bi-2212 wires newly manufactured by Bruker EST. Here, the goal is to build and test Bi-2212 prototype coils for fast ramp central solenoid (CS) operation of spherical tokamaks (ST). For a ST pilot plant, one of the key challenges is the tight space available for CS in a center column where in-board legs of the toroidal field (TF) and OH coils are assembled into a cryostat with a few millimeters clearance. A high current density Rutherford cable consisting of 17 legacy Bi-2212 wires, a contribution of the US Magnet Development Program (MDP), was fabricated at the Lawrence Berkeley National Laboratory (LBNL) for the development of fast ramp CS magnets in the ST Advanced Reactor (STAR) designed by PPPL. Characterization of the new and legacy HTS wires is presented, along with the coil design wound directly with new wire, and a Rutherford cable-wound solenoid using the legacy wire. A comparison of AC losses is made based on expected performance for a fast ramp ST operation. The HTS cable and cabled coil fabrication issues such as the heat treatment, coil mandrel design, assembly and 2212 quench characteristics are discussed, along with a test plan for CS design validation.

Zhai, Yuhu [Princeton Plasma Physics Laboratory (P↗

High efficiency compact microwave sources using electrostatic potential depression

In this article, we report theoretical and design studies on the application of an electrostatic potential depression (EPD) on two types of traditional microwave sources, the klystron and the inductive output tube (IOT), both operating in the UHF band. Additionally, the EPD is implemented by a section of the metallic beam pipe on which a direct current (dc) negative high voltage is applied. Inside the EPD section, the modulated electron beam develops into bunches over a very short longitudinal distance, indicating a possible design approach for a compact device. With the application of an EPD, the peak value of the first harmonic current in a microwave tube can be further increased compared to that in a conventional design, suggesting higher circuit efficiency. As the electron beam leaves the EPD section, the reacceleration of the beam provides a longitudinal cooling effect. With the addition of an EPD, circuit power extraction efficiency above 80% is achieved in both the modified design of the IOT and the novel conceptual circuit design of the klystron.

42 ENGINEERING↗

Novel Electrically Tunable Microwave Solenoid Inductor and Compact Phase Shifter Utilizing Permaloy and PZT Thin Films

A Permalloy (Py) thin film enabled tunable 3-D solenoid inductor is designed and fabricated. The special configuration of magnetic core is discussed and by selectively patterning Py thin film, the proposed tunable inductor can work at frequency up to several GHz range. The inductance of the solenoid inductor can be electrically tuned by dc current and the tunability is above 10%. Utilizing the implemented Py enabled tunable solenoid inductor and Lead Zirconate Titanate (PZT) thin film enabled metal-insulator-metal (MIM) capacitor, a compact fully electrically tunable lumped elements phase shifter is achieved. The tunable phase shifter has both inductive and capacitive tunability and the dual tunability significantly improves the tuning range and design flexibility. Moreover, the dual tunability is able to retain the equivalent characteristic impedance of the device in the process of the phase being tuned. Here, the phase of the device can be tuned by fully electrical methods and when dc current and dc voltage are provided, the length normalized phase tunability is up to 210°/cm

36 MATERIALS SCIENCE↗

A Compact Low-Power Driver Array for VCSELs in 65-nm CMOS Technology

This article presents a compact low-power 4 x 10 Gb/s quad-driver module for Vertical-Cavity Surface-Emitting Laser (VCSEL) arrays in a 65 nm CMOS technology. The side-by-side drivers can be directly wire bonded to the VCSEL diode array, supporting up to 4 channels. To increase the bandwidth of the driver, an internal feed-forward path is added for pole-zero cancellation, without increasing the power consumption. An edge-configurable pre-emphasis technique is proposed to achieve high bandwidth and minimize the asymmetry of the fall and rise times of the driver output current. Measurement results demonstrate a RMS jitter of 0.68 ps for 10 Gb/s operation. Tests demonstrate negligible crosstalk between channels. Under irradiation, the modulation amplitude degrades less than 5% up to 300 Mrad ionizing dose. Finally, the area of the quaddriver array is 500 μm by 1000 μm and the total power consumption for the entire driver array chip is 130 mW for the typical current setting.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of a Length Extensional Piezoelectric Transformer for Compact and Efficient Particle Acceleration

To produce a compact and efficient particle accelerator, several different piezoelectric transformer configurations are evaluated for their applicability in this demanding application area. Using a derived 1-D model for three different electroding and mounting schemes, accelerator efficiency and gradient are optimized. In conclusion, it is shown that with some advancements in material yield strength and advanced bonding techniques, reaching 4 MeV/m with over 40% efficiency is possible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design Considerations for Compact High-Average Power Free-Electron Lasers/Masers at Terahertz Frequencies

Interest is increasing in high-power terahertz (THz) sources of radiation. The terminology is fluid, but researchers in the field typically refer to frequencies ranging from about 300 GHz to 10 THz as THz radiation. In this article, we present a description of design considerations for a compact, high-average power free-electron laser. At present, THz radiation is generated by a variety of mechanisms, including laser-based sources and electron-beam-based sources. Here, we provide a short description of current THz source technology to give background against which to compare the present concept; however, this should not be considered a comprehensive discussion of such technologies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PET Imaging of Leg Arteries for Determining the Input Function in PET/MRI Brain Studies Using a Compact, MRI-Compatible PET System

In this work, we used a compact, high-resolution, and magnetic resonance imaging (MRI)-compatible positron emission tomography (PET) camera (VersaPET) to assess the feasibility of measuring the image-derived input function (IDIF) from arteries in the leg with the ultimate goal of enabling fully quantitative PET brain imaging without blood sampling. We used this approach in five 18 F-FDG PET/MRI brain studies in which the input function was also acquired using the gold standard of serial arterial blood sampling. After accounting for partial volume, dispersion, and calibration effects, we compared the metabolic rates of glucose (MRglu) quantified from VersaPET IDIFs in 80 brain regions to those using the gold standard and achieved a bias and variability of <5% which is within the range of reported test-retest values for this type of study. We also achieved a strong linear relationship (R 2 >0.97) against the gold standard across regions. The results of this preliminary study are promising and support further studies to optimize methods, validate in a larger cohort, and extend to the modeling of other radiotracers.

47 OTHER INSTRUMENTATION↗

Quasi‐static confined uniaxial compaction of granular alumina and boron carbide observing the particle size effects

Abstract The quasi‐static confined uniaxial compaction of granular alumina and boron carbide was studied, and the effect of triaxial stress on the materials as a function of increasing particle size was observed. The average particle sizes studied for granular alumina were 170 ± 63, 230 ± 55, 330 ± 67, and 450 ± 83 µm. The average particle size studied for granular boron carbide were 170 ± 40, 190 ± 34, 320 ± 59, and 470 ± 90 µm. The material response at hydrostatic pressure as a function of porosity, the bulk modulus as a function of hydrostatic pressure, and the transmission ratio as a function of applied load was evaluated for increasing particle size. For alumina, the increase in particle size resulted in an increase in strength for a fixed porosity, the bulk modulus of this material did not show clear particle size‐dependent trends, and the transmission ratio increased with increase in particle size. Conversely, for granular boron carbide, the hydrostatic pressure‐porosity curve shifted to the right with increasing particle size, the change in bulk modulus increased with increasing particle size, and no clear particle size‐dependent trends were observed when looking at the transmission ratio during the experiment. Post‐experiment scanning electron microscopy revealed that alumina powder fragmented from elongated shapes to block‐like structures, while boron carbide powder appeared more circular before the experiments and fragmented into smaller comminuted pieces. This paper discusses the implication of the work in the context of the limited experimental data in the field and the modeling of granular advanced ceramics behavior.

Nicewicz, Piotr↗

Preparing Li-garnet electrodes with engineered structures by phase inversion and high shear compaction processes

We report solid-state lithium batteries are promising for safety and energy density com-pared with traditional lithium-ion batteries. However, the large interfacial resistance between the electrode and electrolyte is a bottleneck to achieving high-performance solid-state batteries. Engineered electrode structures with a porous scaffold of the solid electrolyte material are promising to lower the interfacial resistance and provide a mechanical support for a thin solid electrolyte layer. In this work, two ceramic processing techniques are used to fabricate porous/dense bilayer architectures based on a Li 6.25 Al 0.25 La 3 Zr 2 O 12 (LLZO) Li-garnet material. Finger-like vertically aligned pores are created by the phase inversion (PI) process. A water bath presaturated with Li salt prevents Li loss during the PI solvent exchange step. Pore size and porosity can be optimized by adjusting the bath temperature. The high shear compaction process was used to prepare LLZO tapes with 40, 60, and 80 vol% poreformer. The porosity of the tapes after sintering is 39.5%, 58.4%, and 75.4%, respectively. Microtomography exhibits the porosity, pore shape, and pore distribution of the tapes. A typical cathode material LiNi 0.33 Mn 0.33 Co 0.33 O 2 (NMC) is filled into the pores via vacuum infiltration, and a dense cathode layer is formed within the garnet scaffold.

25 ENERGY STORAGE↗

Characterization and Scaling of Forced Convective Swirl in Sinusoidal Wavy-Plate-Fin Cores of Compact Heat Exchangers

The characterization and scaling of the thermal-hydraulic performance in wavy plate-fin compact heat exchanger cores, based on the understanding of the physical phenomena and heat transfer enhancement mechanism is delineated. Experimental data are presented for forced convection in air (Pr = 0.71) with flow rates in the range 50 ≤ Re ≤ 4000. A variety of wavy-fin cores that span viable applications, with geometrical attributes described by the cross section aspect ratio α (ratio of fin spacing to height), fin corrugation aspect ratio γ (ratio of 2× corrugation amplitude to wave pitch), and fin spacing ratio ζ (ratio of fin spacing to wave pitch), are considered. To characterize and correlate the vortex-flow mixing in interfin spaces, a Swirl number Sw is introduced from the balance of viscous, inertial and centrifugal forces. It is shown that the laminar, transitional and turbulent flow regimes can be explicitly identified by this Swirl number. Based on the experimental results and extended analysis, new correlations for Fanning friction factor f and Colburn factor j are developed with Sw, α, γ, and ζ as scaling parameters. Requisite expressions are devised by a superposition of both enhancement components due to the corrugated surface area enlargement and induced swirl flow field, and they are combined to cover the laminar, transitional and turbulent regimes by the method of asymptotic matching. The resulting generalized correlations are further shown to predict all available experimental data for f and j factors to within ±20% and ±15%, respectively.

42 ENGINEERING↗

High Power Density Thermal Energy Storage With Phase Change Material in Enhanced Compact Heat Exchangers

Abstract Performance of a novel ultracompact thermal energy storage (TES) heat exchanger, designed as a microchannel finned-tube exchanger is presented. With water as the heating–cooling fluid in the microchannels, a salt hydrate phase change material (PCM), lithium nitrate trihydrate (LiNO3 · 3H2O), was encased on the fin side. To establish the hypothesis that small-length-scale encasement (<3 mm) of PCM substantially enhances heat transfer to yield very high power-density energy storage, heat exchanger designs with 10 and 24 fins/inch were considered. They were subjected to thermal cycling, or repeated heating (melting) and cooling (freezing), with inlet fluid flow mimicking diurnal variation between 42 °C and 25 °C (representing typical arid-region conditions) over an accelerated time period. By employing salt self-seeding to obviate subcooling during cooling or recrystallization, the TES was found to exhibit stable long-term (100 heating–cooling cycles) operation with very high PCM-side heat transfer coefficients (∼100–500 W/m2 K) and storage power density (∼160–175 kW/m3). In fact, with optimization of heating–cooling fluid flowrate for given charging–discharging time period and exchanger size, power density >300 kW/m3 can be achieved. The results clearly establish that highly compact heat exchangers used as TES units can provide very high-performance alternatives to conventional ones.

Engineering↗

Diffusion bonded compact heat exchanger in Inconel 740H for high temperature and high-pressure applications

It is desired to develop heat exchangers able to be operated at high temperatures (750°C) and pressures (3636 psi) for use in advanced Brayton power cycle. Conventional materials have not had the high strength at temperature required for these applications previously, however a fairly new material Inconel 740H developed by Special Metals for the ultra-supercritical water fossil industry has shown good performance under these conditions. In further efforts to capitalize on these new high strength high temperature alloys CompRex has developed a diffusion bonding procedure capable of alloying compact high effectiveness heat exchangers that can perform under these high temperature and high-pressure conditions. Initial tests of the heat exchanger are being conducted at the University of Wisconsin using supercritical CO2 working fluid. The bonding process has been adjusted such that the strength of the bonded block has achieved over 90% yield and tensile strength of the 740H base material values. Grain size before and after bonding were measured to determine the extent of grain growth and grain diffusion across the interface. A discussion of the heat exchanger design, etching and initial tensile tests on sample bonds will be discussed.

14 SOLAR ENERGY↗

SU-E-T-200: IBA ProteusOne Compact Proton Therapy System Radiation Survey Results

Purpose: This study summarizes the results of an initial radiation survey of the Willis-Knighton Cancer Center in Shreveport, Louisiana. The facility houses an IBA ProteusOne compact single room proton therapy unit coupled with a C230 cyclotron that operates at a maximum energy of 230 MeV. Methods: A calibrated survey meter was used for the photon measurements to obtain reliable results. A neutron detector was used as the measuring instrument for neutrons. The locations of the survey and measurements were planned carefully in order to get a proper evaluation of the facility shielding configuration. The walls, ceiling, vault entrance, and the adjacent environment were each surveyed with suitable measurement instruments. A total of 22 locations were chosen for radiation survey. Dose equivalent values were calculated for both the photon and the neutron radiation using measured data. Results: All measured dose values are presented in millisievert per year. The highest dose measured at the vault entrance is 0.34 mSv/year. A dedicated shielding door was not present at the time of the measurement. The vault entrance area is considered as a controlled area. The shielding design goals are not to exceed 5 mSv/year for the controlled area and 1 mSv/year the uncontrolled area. The total combined neutron and photon dose equivalent values were found to be compliant with the Louisiana Department of Environmental Quality radiation protection regulatory codes. Conclusion: In our efforts to evaluate the radiation levels at the Willis-Knighton Cancer Center proton treatment facility, we have found that all the measured values of the radiation shielding are below the critical radiation limits per year. Since the total dose measured at the vault entrance is below the shielding design goal, a shielding door is not required at this proton treatment vault.

60 APPLIED LIFE SCIENCES↗

TH-C-12A-08: New Compact 10 MV S-Band Linear Accelerator: 3D Finite-Element Design and Monte Carlo Dose Simulations

Purpose: To design a new compact S-band linac waveguide capable of producing a 10 MV x-ray beam, while maintaining the length (27.5 cm) of current 6 MV waveguides. This will allow higher x-ray energies to be used in our linac-MRI systems with the same footprint. Methods: Finite element software COMSOL Multiphysics was used to design an accelerator cavity matching one published in an experiment breakdown study, to ensure that our modeled cavities do not exceed the threshold electric fields published. This cavity was used as the basis for designing an accelerator waveguide, where each cavity of the full waveguide was tuned to resonate at 2.997 GHz by adjusting the cavity diameter. The RF field solution within the waveguide was calculated, and together with an electron-gun phase space generated using Opera3D/SCALA, were input into electron tracking software PARMELA to compute the electron phase space striking the x-ray target. This target phase space was then used in BEAM Monte Carlo simulations to generate percent depth doses curves for this new linac, which were then used to re-optimize the waveguide geometry. Results: The shunt impedance, Q-factor, and peak-to-mean electric field ratio were matched to those published for the breakdown study to within 0.1% error. After tuning the full waveguide, the peak surface fields are calculated to be 207 MV/m, 13% below the breakdown threshold, and a d-max depth of 2.42 cm, a D10/20 value of 1.59, compared to 2.45 cm and 1.59, respectively, for the simulated Varian 10 MV linac and brehmsstrahlung production efficiency 20% lower than a simulated Varian 10 MV linac. Conclusion: This work demonstrates the design of a functional 27.5 cm waveguide producing 10 MV photons with characteristics similar to a Varian 10 MV linac.

07 ISOTOPE AND RADIATION SOURCES↗

SU-C-304-04: A Compact Modular Computational Platform for Automated On-Board Imager Quality Assurance

Purpose: Traditionally, the assessment of X-ray tube output and detector positioning accuracy of on-board imagers (OBI) has been performed manually and subjectively with rulers and dosimeters, and typically takes hours to complete. In this study, we have designed a compact modular computational platform to automatically analyze OBI images acquired with in-house designed phantoms as an efficient and robust surrogate. Methods: The platform was developed as an integrated and automated image analysis-based platform using MATLAB for easy modification and maintenance. Given a set of images acquired with the in-house designed phantoms, the X-ray output accuracy was examined via cross-validation of the uniqueness and integration minimization of important image quality assessment metrics, while machine geometric and positioning accuracy were validated by utilizing pattern-recognition based image analysis techniques. Results: The platform input was a set of images of an in-house designed phantom. The total processing time is about 1–2 minutes. Based on the data acquired from three Varian Truebeam machines over the course of 3 months, the designed test validation strategy achieved higher accuracy than traditional methods. The kVp output accuracy can be verified within +/−2 kVp, the exposure accuracy within 2%, and exposure linearity with a coefficient of variation (CV) of 0.1. Sub-millimeter position accuracy was achieved for the lateral and longitudinal positioning tests, while vertical positioning accuracy within +/−2 mm was achieved. Conclusion: This new platform delivers to the radiotherapy field an automated, efficient, and stable image analysis-based procedure, for the first time, acting as a surrogate for traditional tests for LINAC OBI systems. It has great potential to facilitate OBI quality assurance (QA) with the assistance of advanced image processing techniques. In addition, it provides flexible integration of additional tests for expediting other OBI quality assurance tests, such as 2D/3D image quality, making completely automated QA possible. Research Funding from Varian Medical Systems Inc. . Dr. Sasa Mutic receives compensation for providing patient safety training services from Varian Medical Systems, the sponsor of this study.

60 APPLIED LIFE SCIENCES↗

SU-E-T-188: Commission of World 1st Commercial Compact PBS Proton System

Purpose: ProteusONE is the 1st commercial compact PBS proton system with an upstream scanning gantry and C230 cyclotron. We commissioned XiO and Raystation TPS simultaneously. This is a summary of beam data collection, modeling, and verification and comparison without range shiter for this unique system with both TPS. Methods: Both Raystation and XiO requires the same measurements data: (i) integral depth dose(IDDs) of single central spot measured in water tank; (ii) absolute dose calibration measured at 2cm depth of water with mono-energetic 10×10 cm2 field with spot spacing 4mm, 1MU per spot; and (iii) beam spot characteristics in air at 0cm and ± 20cm away from ISO. To verify the beam model for both TPS, same 15 cube plans were created to simulate different treatment sites, target volumes and positions. PDDs of each plan were measured using a Multi-layer Ionization Chamber(MLIC), absolute point dose verification were measured using PPC05 in water tank and patient-specific QA were measured using MatriXX PT, a 2D ion chamber array. Results: All the point dose measurements at midSOBP were within 2% for both XiO and Raystation. However, up to 5% deviations were observed in XiO’s plans at shallow depth while within 2% in Raystation plans. 100% of the ranges measured were within 1 mm with maximum deviation of 0.5 mm. 20 patient specific plan were generated and measured in 3 planes (distal, proximal and midSOBP) in Raystation. The average of gamma index is 98.7%±3% with minimum 94% Conclusions: Both TPS were successfully commissioned and can be safely deployed for clinical use for ProteusONE. Based on our clinical experience in PBS planning, user interface, function and workflow, we preferably use Raystation as our main clinical TPS. Gamma Index >95% at 3%/3 mm criteria is our institution action level for patient specific plan QAs.

60 APPLIED LIFE SCIENCES↗