Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

SU-F-I-40: Impact of Scan Length On Patient Dose in Abdomen/pelvis CT Diagnosis

Purpose: To analysis the impact of scan length on patient doses in abdomen/pelvis CT diagnosis of each hospital. Methods: Scan length of 7 hospitals from abdomen/pelvis CT diagnosis was surveyed in Korea. Surveyed scan lengths were additional distance above diaphragm and distance below pubic symphysis except for standard scan range between diaphragm and pubic symphysis. Patient dose was estimated for adult male and female according to scan length of each hospital. CT-Expo was used to estimate the patient dose under identical equipment settings (120 kVp, 100 mAs, 10 mm collimation width, etc.) except scan length. Effective dose was calculated by using tissue weighting factor of ICRP 103 recommendation. Increase rate of effective dose was calculated comparing with effective dose of standard scan range Results: Scan lengths of abdomen/pelvis CT diagnosis of each hospital were different. Also effective dose was increased with increasing the scan length. Generally increasing the distance above diaphragm caused increase of effective dose of male and female, but increasing the distance below pubic symphysis caused increase of effective dose of male. Conclusion: We estimated the patient dose according to scan length of each hospital in abdomen/pelvis CT diagnosis. Effective dose was increased by increasing the scan length because dose of organs with high tissue weighting factor such as lung, breast, testis were increased. Scan length is important factor on patient dose in CT diagnosis. If radiologic technologist interested in patient dose, decreasing the unnecessary scan length will decrease the risk of patients from radiation. This research was supported by a grant of the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea (grant number: HI13C0004).

60 APPLIED LIFE SCIENCES↗

Analytic image reconstruction from partial data for a single-scan cone-beam CT with scatter correction

Purpose: A beam-blocker composed of multiple strips is a useful gadget for scatter correction and/or for dose reduction in cone-beam CT (CBCT). However, the use of such a beam-blocker would yield cone-beam data that can be challenging for accurate image reconstruction from a single scan in the filtered-backprojection framework. The focus of the work was to develop an analytic image reconstruction method for CBCT that can be directly applied to partially blocked cone-beam data in conjunction with the scatter correction. Methods: The authors developed a rebinned backprojection-filteration (BPF) algorithm for reconstructing images from the partially blocked cone-beam data in a circular scan. The authors also proposed a beam-blocking geometry considering data redundancy such that an efficient scatter estimate can be acquired and sufficient data for BPF image reconstruction can be secured at the same time from a single scan without using any blocker motion. Additionally, scatter correction method and noise reduction scheme have been developed. The authors have performed both simulation and experimental studies to validate the rebinned BPF algorithm for image reconstruction from partially blocked cone-beam data. Quantitative evaluations of the reconstructed image quality were performed in the experimental studies. Results: The simulation study revealed that the developed reconstruction algorithm successfully reconstructs the images from the partial cone-beam data. In the experimental study, the proposed method effectively corrected for the scatter in each projection and reconstructed scatter-corrected images from a single scan. Reduction of cupping artifacts and an enhancement of the image contrast have been demonstrated. The image contrast has increased by a factor of about 2, and the image accuracy in terms of root-mean-square-error with respect to the fan-beam CT image has increased by more than 30%. Conclusions: The authors have successfully demonstrated that the proposed scanning method and image reconstruction algorithm can effectively estimate the scatter in cone-beam projections and produce tomographic images of nearly scatter-free quality. The authors believe that the proposed method would provide a fast and efficient CBCT scanning option to various applications particularly including head-and-neck scan.

60 APPLIED LIFE SCIENCES↗

Kimberlina 1.2 CCUS Geophysical Models and Synthetic Data Sets

This synthetic multi-scale and multi-physics data set was produced in collaboration with teams at the Lawrence Berkeley National Laboratory, National Energy Technology Laboratory, Los Alamos National Laboratory, and Colorado School of Mines through the Science-informed Machine Learning for Accelerating Real-Time Decisions in Subsurface Applications (SMART) Initiative. Data are associated with the following publication: Alumbaugh, D., Gasperikova, E., Crandall, D., Commer, M., Feng, S., Harbert, W., Li, Y., Lin, Y., and Samarasinghe, S., “The Kimberlina Synthetic Geophysical Model and Data Set for CO2 Monitoring Investigations”, The Geoscience Data Journal, 2023, DOI: 10.1002/gdj3.191. The dataset uses the Kimberlina 1.2 CO2 reservoir flow model simulations based on a hypothetical CO2 storage site in California (Birkholzer et al., 2011; Wainwright et al., 2013). Geophysical properties models (P- and S-wave seismic velocities, saturated density, and electrical resistivity) were produced with an approach similar to that of Yang et al. (2019) and Gasperikova et al. (2022) for 100 Kimberlina 1.2 reservoir models. Links to individual resources are provided below: [CO2 Saturation Models](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-co2-saturation-models); Resistivity Models – [part 1](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-resistivity-models-part-1), [part 2](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-resistivity-models-part-2), and [part 3](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-resistivity-models-part-3); [Vp Velocity Models](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-vp-velocity-models); [Vs Velocity Models](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-vs-velocity-models); [Density Models](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-density-models). The 3D distributions of geophysical properties for the 33 time stamps of the SIM001 model were used to generate synthetic seismic, gravity, and electromagnetic (EM) responses for 33 times between zero and 200 years. Synthetic surface seismic data were generated using 2D and 3D finite-difference codes that simulate the acoustic wave equation (Moczo et al., 2007). 2D data were simulated for six point-pressure sources along a 2D line with 10 m receiver spacing and a time spacing of 0.0005 s. 3D simulations were completed for 25 surface pressure sources using a source separation of 1 km in both the x and y directions and a time spacing of 0.001 s. Links to individual resources are provided below: [2D velocity models](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-2d-velocity-models) and [2D surface seismic data](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-2d-surface-seismic-data). [3D velocity models](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-velocity-models), and 3D seismic data [year0](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year0), [year1](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year1), [year2](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year2), [year5](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year5), [year10](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year10), [year15](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year15), [year20](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year20), [year25](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year25), [year30](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year30), [year35](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year35), [year40](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year40), [year45](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year45), [year49](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year49), [year50](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year50), [year51](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year51), [year52](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year52), [year55](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year55), [year60](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year60), [year65](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year65), [year70](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year70), [year75](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year75), [year80](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year80), [year85](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year85), [year90](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year90), [year95](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year95), [year100](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year100), [year110](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year110), [year120](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year120), [year130](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year130), [year140](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year140), [year150](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year150), [year175](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year175), [year200](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year200). The Python scripts to read these models and data are provided [here](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-python-scripts). EM simulations used a borehole-to-surface survey configuration, with the source located near the reservoir level and receivers on the surface using the code developed by Commer and Newman (2008). Pseudo-2D data for the source at [2500 m](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-pseudo-2d-csem-data-tz2500m) and [3025 m](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-pseudo-2d-csem-data-tz3025m), used a 2D inline receiver configuration to simulate a response over 3D resistivity models. The [3D data](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-csem-data) contain electric fields generated by borehole sources at monitoring well locations and measured over a surface receiver grid. Vector gravity data, both on the surface and in boreholes, were simulated using a modeling code developed by Rim and Li (2015). The simulation scenarios were parallel to those used for the EM: [pseudo-2D data](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-gravity-data) were calculated along the same lines and within the same boreholes, and [3D data](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-gravity-data) were simulated over 3D models on the surface and in three monitoring wells. A series of [synthetic well logs](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-well-logs) of CO2 saturation, acoustic velocity, density, and induction resistivity in the injection well and three monitoring wells are also provided at 0, 1, 2, 5, 10, 15, and 20 years after the initiation of injection. These were constructed by combining the low-frequency trend of the geophysical models with the high-frequency variations of actual well logs collected in the Kimberlina 1 well that was drilled at the proposed site. Measurements of permeability and pore connectivity were made on cores of Vedder Sandstone, which forms the primary reservoir unit: [CT micro scans](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-ct-micro-scans-of-vedder-formation) and [Industrial CT Images](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-industrial-ct-images-vedder-formation). These measurements provide the range of scales in the otherwise synthetic data set to be as close to a real-world situation as possible. References: Birkholzer, J.T., Zhou, Q., Cortis, A. and Finsterle, S., 2011. A sensitivity study on regional pressure buildup from large-scale CO2 storage projects. Energy Procedia, 4, 4371-4378. Commer, M., and Newman, G.A., 2008. New advances in three-dimensional controlled-source electromagnetic inversion, Geophysical Journal International, 172, 513-535. Gasperikova, E., Appriou, D., Bonneville, A., Feng, Z., Huang, L., Gao, K., Yang, X., Daley, T., 2022, Sensitivity of geophysical techniques for monitoring secondary CO2 storage plumes, Int. J. Greenh. Gas Control, Volume 114, 103585, ISSN 1750-5836, https://doi.org/10.1016/j.ijggc.2022.103585. Moczo, P., J.O. Robertsson and L. Eisner, 2007, The finite-difference time-domain method for modeling of seismic wave propagation: Advances in geophysics, 48, 421-516. Rim, H., and Y. Li, 2015, Advantages of borehole vector gravity in density imaging, Geophysics, 80, G1-G13. Wainwright, H. M.; Finsterle, S.; Zhou, Q.; Birkholzer, J. T., 2013. Modeling the Performance of Large-Scale CO2 Storage Systems: A Comparison of Different Sensitivity Analysis Methods. International Journal of Greenhouse Gas Control, 17, 189205. https://doi.org/10.1016/j.ijggc.2013.05.007, DOI: 10.18141/1603331. Yang, X., Buscheck, T.A., Mansoor, K., Wang, Z., Gao, K., Huang, L., Appriou, D., and Carroll, S.A., 2019. Assessment of geophysical monitoring methods for detection of brine and CO2 leakage in drinking water aquifers, International Journal of Greenhouse Gas Control, 90, 102803, https://doi.org/10.1016/j.ijggc.2019.102803.

CCUS↗

SU-F-P-42: “To Navigate, Or Not to Navigate: HDR BT in Recurrent Spine Lesions”

Purpose: We compare the accuracy of HDR catheter placement for paraspinal lesions using O-arm CBCT imaging combined with StealthStation navigation and traditional fluoroscopically guided catheter placement. Methods: CT and MRI scans were acquired pre-treatment to outline the lesions and design treatment plans (pre-plans) to meet dosimetric constrains. The pre-planned catheter trajectories were transferred into the StealthStation Navigation system prior to the surgery. The StealthStation is an infra red (IR) optical navigation system used for guidance of surgical instruments. An intraoperative CBCT scan (O-arm) was acquired with reference IR optical fiducials anchored onto the patient and registered with the preplan image study to guide surgical instruments in relation to the patients’ anatomy and to place the brachytherapy catheters along the pre-planned trajectories. The final treatment plan was generated based on a 2nd intraoperative CBCT scan reflecting achieved implant geometry. The 2nd CBCT was later registered with the initial CT scan to compare the preplanned dwell positions with actual dwell positions (catheter placements). Similar workflow was used in placement of 8 catheters (1 patient) without navigation, but under fluoroscopy guidance in an interventional radiology suite. Results: A total of 18 catheters (3 patients) were placed using navigation assisted surgery. Average displacement of 0.66 cm (STD=0.37cm) was observed between the pre-plan source positions and actual source positions in the 3 dimensional space. This translates into an average 0.38 cm positioning error in one direction including registration errors, digitization errors, and the surgeons ability to follow the planned trajectory. In comparison, average displacement of non-navigated catheters was 0.50 cm (STD=0.22cm). Conclusion: Spinal lesion HDR brachytherapy planning is a difficult task. Catheter placement has a direct impact on target coverage and dose to critical structures. While limited to a handful of patients, our experience shows navigation and fluoroscopy guided placement yield similar results.

60 APPLIED LIFE SCIENCES↗

Using Fluorodeoxyglucose Positron Emission Tomography to Assess Tumor Volume During Radiotherapy for Non-Small-Cell Lung Cancer and Its Potential Impact on Adaptive Dose Escalation and Normal Tissue Sparing

Purpose: To quantify changes in fluorodeoxyglucose (FDG)-avid tumor volume on positron emission tomography/computed tomography (PET/CT) during the course of radiation therapy and examine its potential use in adaptive radiotherapy for tumor dose escalation or normal tissue sparing in patients with non-small-cell lung cancer (NSCLC). Methods and Materials: As part of a pilot study, patients with Stage I-III NSCLC underwent FDG-PET/CT before radiotherapy (RT) and in mid-RT (after 40-50 Gy). Gross tumor volumes were contoured on CT and PET scans obtained before and during RT. Three-dimensional conformal RT plans were generated for each patient, first using only pretreatment CT scans. Mid-RT PET volumes were then used to design boost fields. Results: Fourteen patients with FDG-avid tumors were assessed. Two patients had a complete metabolic response, and 2 patients had slightly increased FDG uptake in the adjacent lung tissue. Mid-RT PET scans were useful in the 10 remaining patients. Mean decreases in CT and PET tumor volumes were 26% (range, +15% to -75%) and 44% (range, +10% to -100%), respectively. Designing boosts based on mid-RT PET allowed for a meaningful dose escalation of 30-102 Gy (mean, 58 Gy) or a reduction in normal tissue complication probability (NTCP) of 0.4-3% (mean, 2%) in 5 of 6 patients with smaller yet residual tumor volumes. Conclusions: Tumor metabolic activity and volume can change significantly after 40-50 Gy of RT. Using mid-RT PET volumes, tumor dose can be significantly escalated or NTCP reduced. Clinical studies evaluating patient outcome after PET-based adaptive RT are ongoing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated bone removal in CT angiography: Comparison of methods based on single energy and dual energy scans

Purpose: To evaluate dual energy based methods for bone removal in computed tomography angiography (CTA) images and compare these with single energy based methods that use an additional, nonenhanced, CT scan. Methods: Four different bone removal methods were applied to CT scans of an anthropomorphic thorax phantom, acquired with a second generation dual source CT scanner. The methods differed by the way information on the presence of bone was obtained (either by using an additional, nonenhanced scan or by scanning with two tube voltages at the same time) and by the way the bone was removed from the CTA images (either by masking or subtracting the bone). The phantom contained parts which mimic vessels of various diameters in direct contact with bone. Both a quantitative and qualitative analysis of image quality after bone removal was performed. Image quality was quantified by the contrast-to-noise ratio (CNR) normalized to the square root of the dose (CNRD). At locations where vessels touch bone, the quality of the bone removal and the vessel preservation were visually assessed. The dual energy based methods were assessed with and without the addition of a 0.4 mm tin filter to the high voltage x-ray tube filtration. For each bone removal method, the dose required to obtain a certain CNR after bone removal was compared with the dose of a reference scan with the same CNR but without automated bone removal. The CNRD value of the reference scan was maximized by choosing the lowest tube voltage available. Results: All methods removed the bone completely. CNRD values were higher for the masking based methods than for the subtraction based methods. Single energy based methods had a higher CNRD value than the corresponding dual energy based methods. For the subtraction based dual energy method, tin filtration improved the CNRD value with approximately 50%. For the masking based dual energy method, it was easier to differentiate between iodine and bone when tin filtration was applied. The CNRD value decreased only with 4% in that case. Compared to the dual scan based methods, the dual energy based methods had the advantage that only a single scan was made without the need of image registration. This might be easier to implement in clinical practice. Vessel preservation was better with bone subtraction than with bone masking. Smaller vessels were completely occluded by the bone mask. None of the bone removal methods was dose neutral. Conclusions: In general, dual scan based methods that use the lowest tube voltage available, have a higher CNR than the dual energy based approaches at the same dose level. Tin filtration improves the ability to differentiate between iodine and bone for the dual energy based masking method. In clinical practice, the advantages of the dual energy masking method might outweigh its disadvantage of a slightly higher dose penalty compared to the conventional dual scan masking method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of a Robotic Assistance Device in Computed Tomography-Guided Percutaneous Diagnostic and Therapeutic Procedures

PurposeTo evaluate a commercially available robotic assistance device for computed tomography-guided diagnostic and therapeutic interventions, compared to regular, manually performed CT scan-guided interventions in terms of precision, exposure to radiation to the patient and intervention time.Materials and MethodsOver a period of 6 months, 55 consecutive patients were recruited and treated using robotic assistance and compared to a control group of 101 patients previously treated with a regular CT scan-guided, manual approach. Evaluated parameters were precision (deviation from planned target and number of needle replacements), radiation exposure to the patient and intervention time. Evaluations were performed with regard to complexity (in-plane vs out-of-plane interventions) and type of anesthesia (general vs local).ResultsParameters related to precision were in general significantly better in the robotic assistance group (p < 0.01) with a mean deviation of 1.2 mm (± 1.6 mm) compared to 2.6 mm (± 1.1 mm) in the comparison group. Compared to manual procedure, the mean intervention time was reduced by 15 min (± 5.4 min) on average for an out-of-plane needle placement in the robotic group. There was no increase of exposure to radiation to the patient while radiation exposure for the physician was reduced to zero when the navigation system was used.ConclusionCompared to manual placement, the use of a robotic assistance device in out-of-plane CT-guided interventions under general anesthesia allows for probe placement with high precision. Intervention time is reduced with no increase of exposure to radiation to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-480: Radiobiological Dose Comparison of Single Fraction SRS, Multi-Fraction SRT and Multi-Stage SRS of Large Target Volumes Using the Linear-Quadratic Formula

Purpose: To compare the radiobiological effect on large tumors and surrounding normal tissues from single fraction SRS, multi-fractionated SRT, and multi-staged SRS treatment. Methods: An anthropomorphic head phantom with a centrally located large volume target (18.2 cm{sup 3}) was scanned using a 16 slice large bore CT simulator. Scans were imported to the Multiplan treatment planning system where a total prescription dose of 20Gy was used for a single, three staged and three fractionated treatment. Cyber Knife treatment plans were inversely optimized for the target volume to achieve at least 95% coverage of the prescription dose. For the multistage plan, the target was segmented into three subtargets having similar volume and shape. Staged plans for individual subtargets were generated based on a planning technique where the beam MUs of the original plan on the total target volume are changed by weighting the MUs based on projected beam lengths within each subtarget. Dose matrices for each plan were export in DICOM format and used to calculate equivalent dose distributions in 2Gy fractions using an alpha beta ratio of 10 for the target and 3 for normal tissue. Results: Singe fraction SRS, multi-stage plan and multi-fractionated SRT plans had an average 2Gy dose equivalent to the target of 62.89Gy, 37.91Gy and 33.68Gy, respectively. The normal tissue within 12Gy physical dose region had an average 2Gy dose equivalent of 29.55Gy, 16.08Gy and 13.93Gy, respectively. Conclusion: The single fraction SRS plan had the largest predicted biological effect for the target and the surrounding normal tissue. The multi-stage treatment provided for a more potent biologically effect on target compared to the multi-fraction SRT treatments with less biological normal tissue than single-fraction SRS treatment.

60 APPLIED LIFE SCIENCES↗

Distance-preserving rigidity penalty on deformable image registration of multiple skeletal components in the neck

Purpose: This study aims at developing and testing a novel rigidity penalty suitable for the deformable registration of tightly located skeletal components in the head and neck from planning computed tomography (CT) and daily cone-beam CT (CBCT) scans of patients undergoing radiotherapy. Methods: The proposed rigidity penalty is designed to preserve intervoxel distances within each bony structure. This penalty was tested in the intensity-based B-spline deformable registration of five cervical vertebral bodies (C1–C5). The displacement vector fields (DVFs) from the registrations were compared to the DVFs generated by using rigid body motions of the cervical vertebrae, measured by the surface registration of vertebrae delineated on CT and CBCT images. Twenty five pairs of planning CT (reference) and treatment CBCTs (target) from five patients were aligned without and with the penalty. An existing penalty based on the orthonormality of the deformation gradient tensor was also tested and the effects of the penalties compared. Results: The mean magnitude of the maximum registration error with the proposed distance-preserving penalty was (0.86, 1.12, 1.33) mm compared to (2.11, 2.49, 2.46) without penalty and (1.53, 1.64, 1.64) with the existing orthonormality-based penalty. The improvement in the accuracy of the deformable image registration was also verified by comparing the Procrustes distance between the DVFs. With the proposed penalty, the average distance was 0.11 (σ 0.03 mm) which is smaller than 0.53 (0.1 mm) without penalty and 0.28 (0.04 mm) with the orthonormality-based penalty. Conclusions: The accuracy of aligning multiple bony elements was improved by using the proposed distance-preserving rigidity penalty. The voxel-based statistical analysis of the registration error shows that the proposed penalty improved the integrity of the DVFs within the vertebral bodies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is There a Dose-Response Relationship for Heart Disease With Low-Dose Radiation Therapy?

Purpose: To quantify cardiac radiation therapy (RT) exposure using sensitive measures of cardiac dysfunction; and to correlate dysfunction with heart doses, in the setting of adjuvant RT for left-sided breast cancer. Methods and Materials: On a randomized trial, 32 women with node-positive left-sided breast cancer underwent pre-RT stress single photon emission computed tomography (SPECT-CT) myocardial perfusion scans. Patients received RT to the breast/chest wall and regional lymph nodes to doses of 50 to 52.2 Gy. Repeat SPECT-CT scans were performed 1 year after RT. Perfusion defects (PD), summed stress defects scores (SSS), and ejection fractions (EF) were evaluated. Doses to the heart and coronary arteries were quantified. Results: The mean difference in pre- and post-RT PD was −0.38% ± 3.20% (P=.68), with no clinically significant defects. To assess for subclinical effects, PD were also examined using a 1.5-SD below the normal mean threshold, with a mean difference of 2.53% ± 12.57% (P=.38). The mean differences in SSS and EF before and after RT were 0.78% ± 2.50% (P=.08) and 1.75% ± 7.29% (P=.39), respectively. The average heart Dmean and D95 were 2.82 Gy (range, 1.11-6.06 Gy) and 0.90 Gy (range, 0.13-2.17 Gy), respectively. The average Dmean and D95 to the left anterior descending artery were 7.22 Gy (range, 2.58-18.05 Gy) and 3.22 Gy (range, 1.23-6.86 Gy), respectively. No correlations were found between cardiac doses and changes in PD, SSS, and EF. Conclusions: Using sensitive measures of cardiac function, no clinically significant defects were found after RT, with the average heart Dmean <5 Gy. Although a dose response may exist for measures of cardiac dysfunction at higher doses, no correlation was found in the present study for low doses delivered to cardiac structures and perfusion, SSS, or EF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relative plan robustness of step-and-shoot vs rotational intensity–modulated radiotherapy on repeat computed tomographic simulation for weight loss in head and neck cancer

Introduction: Interfractional anatomical alterations may have a differential effect on the dose delivered by step-and-shoot intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT). The increased degrees of freedom afforded by rotational delivery may increase plan robustness (measured by change in target volume coverage and doses to organs at risk [OARs]). However, this has not been evaluated for head and neck cancer. Materials and methods: A total of 10 patients who required repeat computed tomography (CT) simulation and replanning during head and neck IMRT were included. Step-and-shoot IMRT and VMAT plans were generated from the original planning scan. The initial and second CT simulation scans were fused and targets/OAR contours transferred, reviewed, and modified. The plans were applied to the second CT scan and doses recalculated without repeat optimization. Differences between step-and-shoot IMRT and VMAT for change in target volume coverage and doses to OARs between first and second CT scans were compared by Wilcoxon signed rank test. Results: There were clinically relevant dosimetric changes between the first and the second CT scans for both the techniques (reduction in mean D{sub 95%} for PTV2 and PTV3, D{sub min} for CTV2 and CTV3, and increased mean doses to the parotid glands). However, there were no significant differences between step-and-shoot IMRT and VMAT for change in any target coverage parameter (including D{sub 95%} for PTV2 and PTV3 and D{sub min} for CTV2 and CTV3) or dose to any OARs (including parotid glands) between the first and the second CT scans. Conclusions: For patients with head and neck cancer who required replanning mainly due to weight loss, there were no significant differences in plan robustness between step-and-shoot IMRT and VMAT. This information is useful with increased clinical adoption of VMAT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation assessment to paediatric with F-18-FDG undergo whole-body PET/CT examination

This study was carried out on wholebody radiation dose assessment to paediatrics patient who undergo PET/CT scanner at Institut Kanser Negara. Consist of 68 patients with varies of malignancies and epilepsy disease case covering age between 2 years to 12 years old. This is a retrospective study from 2010-2014. The use of PET/CT scanner as an advanced tool has been proven to give an extra radiation dose to the patient. It is because of the radiation exposure from the combination of both CT and PET scans rather than a single CT or PET scan. Furthermore, a study on radiation dose to paediatric patient undergoing PET/CT is rare in Malaysia. So, the aim of this study is to estimate the wholebody effective dose to paediatric patient in Malaysia. Effective dose from PET scan was calculated based on the activity of F18 FDG and dose coefficient reported in International Commission on Radiological Protection (ICRP) Publication 106. Effective dose from CT was determined using k coefficient as reported in ICRP publication 102 and Dose Length Product (DLP) value. The average effective dose from PET and CT were found to be 7.05mSv and 5.77mSv respectively. The mean wholebody effective dose received by a patient with combined PETCT examination was 12.78mSv. These results could be used as reference for dosimetry of a patient undergoing PETCT examination in Malaysia.

07 ISOTOPE AND RADIATION SOURCES↗

Synthetic CT: Simulating low dose single and dual energy protocols from a dual energy scan

Purpose: The choice of CT protocol can greatly impact patient dose and image quality. Since acquiring multiple scans at different techniques on a given patient is undesirable, the ability to predict image quality changes starting from a high quality exam can be quite useful. While existing methods allow one to generate simulated images of lower exposure (mAs) from an acquired CT exam, the authors present and validate a new method called synthetic CT that can generate realistic images of a patient at arbitrary low dose protocols (kVp, mAs, and filtration) for both single and dual energy scans. Methods: The synthetic CT algorithm is derived by carefully ensuring that the expected signal and noise are accurate for the simulated protocol. The method relies on the observation that the material decomposition from a dual energy CT scan allows the transmission of an arbitrary spectrum to be predicted. It requires an initial dual energy scan of the patient to either synthesize raw projections of a single energy scan or synthesize the material decompositions of a dual energy scan. The initial dual energy scan contributes inherent noise to the synthesized projections that must be accounted for before adding more noise to simulate low dose protocols. Therefore, synthetic CT is subject to the constraint that the synthesized data have noise greater than the inherent noise. The authors experimentally validated the synthetic CT algorithm across a range of protocols using a dual energy scan of an acrylic phantom with solutions of different iodine concentrations. An initial 80/140 kVp dual energy scan of the phantom provided the material decomposition necessary to synthesize images at 100 kVp and at 120 kVp, across a range of mAs values. They compared these synthesized single energy scans of the phantom to actual scans at the same protocols. Furthermore, material decompositions of a 100/120 kVp dual energy scan are synthesized by adding correlated noise to the initial material decompositions. The aforementioned noise constraint also allows us to compute feasible mAs values that can be synthesized for each kVp. Results: The single energy synthesized and actual reconstructed images exhibit identical signal and noise properties at 100 kVp and at 120 kVp, and across a range of mAs values. For example, the noise in both the synthesized and actual images at 100 kVp increases by {radical}(2) when the mAs is halved. The synthesized and actual material decompositions of a dual energy protocol show excellent agreement when the decomposition images are linearly weighted to form monoenergetic images at energies from 40 to 100 keV. For simulated single energy protocols with kVp between 80 and 140, the highest feasible mAs exceeds that of either initial scan. Conclusions: This work describes and validates the synthetic CT theory and algorithm by comparing its results to actual scans. Synthetic CT is a powerful new tool that allows users to realistically see how protocol selection affects CT images and enables radiologists to retrospectively identify the lowest dose protocol achievable that provides diagnostic quality images on real patients.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-R-30: Interscanner Variability of Radiomics Features in Computed Tomography (CT) Using a Standard ACR Phantom

Purpose: A simple approach to investigate Interscanner variability of Radiomics features in computed tomography (CT) using a standard ACR phantom. Methods: The standard ACR phantom was scanned on CT scanners from three different manufacturers. Scanning parameters of 120 KVp, 200 mA were used while slice thickness of 3.0 mm on two scanners and 3.27 mm on third scanner was used. Three spherical regions of interest (ROI) from water, medium density and high density inserts were contoured. Ninety four Radiomics features were extracted using an in-house program. These features include shape (11), intensity (22), GLCM (26), GLZSM (11), RLM (11), and NGTDM (5) and 8 fractal dimensions features. To evaluate the Interscanner variability across three scanners, a coefficient of variation (COV) is calculated for each feature group. Each group is further classified according to the COV- by calculating the percentage of features in each of the following categories: COV less than 2%, between 2 and 10% and greater than 10%. Results: For all feature groups, similar trend was observed for three different inserts. Shape features were the most robust for all scanners as expected. 70% of the shape features had COV <2%. For intensity feature group, 2% COV varied from 9 to 32% for three scanners. All features in four groups GLCM, GLZSM, RLM and NGTDM were found to have Interscanner variability ≥2%. The fractal dimensions dependence for medium and high density inserts were similar while it was different for water inserts. Conclusion: We concluded that even for similar scanning conditions, Interscanner variability across different scanners was significant. The texture features based on GLCM, GLZSM, RLM and NGTDM are highly scanner dependent. Since the inserts of the ACR Phantom are not heterogeneous in HU values suggests that matrix based 2nd order features are highly affected by variation in noise. Research partly funded by NIH/NCI R01CA190105-01.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP4-11: Monitoring Tumor Growth in Subcutaneous Murine Tumor Model in Vivo: A Comparison Between MRI and Small Animal CT

Purpose: The purpose of the study is to compare the volume measurement of subcutaneous tumors in mice with different imaging platforms, namely a GE MRI and a Sofie-Biosciences small animal CT scanner. Methods: A549 human lung carcinoma cells and FaDu human head and neck squamous cell carcinoma cells were implanted subcutaneously into flanks of nude mice. Three FaDu tumors and three A549 tumors were included in this study. The MRI scans were done with a GE Signa 1.5 Tesla MR scanner using a fast T2-weighted sequence (70mm FOV and 1.2mm slice thickness), while the CT scans were done with the CT scanner on a Sofie-Biosciences G8 PET/CT platform dedicated for small animal studies (48mm FOV and 0.2mm slice thickness). Imaging contrast agent was not used in this study. Based on the DICOM images from MRI and CT scans, the tumors were contoured with Philips DICOM Viewer and the tumor volumes were obtained by summing up the contoured area and multiplied by the slice thickness. Results: The volume measurements based on the CT scans agree reasonably with that obtained with MR images for the subcutaneous tumors. The mean difference in the absolute tumor volumes between MRI- and CT-based measurements was found to be −6.2% ± 1.0%, with the difference defined as (VMR – VCT)*100%/VMR. Furthermore, we evaluated the normalized tumor volumes, which were defined for each tumor as V/V{sub 0} where V{sub 0} stands for the volume from the first MR or CT scan. The mean difference in the normalized tumor volumes was found to be 0.10% ± 0.96%. Conclusion: Despite the fact that the difference between normal and abnormal tissues is often less clear on small animal CT images than on MR images, one can still obtain reasonable tumor volume information with the small animal CT scans for subcutaneous murine xenograft models.

60 APPLIED LIFE SCIENCES↗

Denoising of polychromatic CT images based on their own noise properties

Purpose: Because of high diagnostic accuracy and fast scan time, computed tomography (CT) has been widely used in various clinical applications. Since the CT scan introduces radiation exposure to patients, however, dose reduction has recently been recognized as an important issue in CT imaging. However, low-dose CT causes an increase of noise in the image and thereby deteriorates the accuracy of diagnosis. In this paper, the authors develop an efficient denoising algorithm for low-dose CT images obtained using a polychromatic x-ray source. The algorithm is based on two steps: (i) estimation of space variant noise statistics, which are uniquely determined according to the system geometry and scanned object, and (ii) subsequent novel conversion of the estimated noise to Gaussian noise so that an existing high performance Gaussian noise filtering algorithm can be directly applied to CT images with non-Gaussian noise. Methods: For efficient polychromatic CT image denoising, the authors first reconstruct an image with the iterative maximum-likelihood polychromatic algorithm for CT to alleviate the beam-hardening problem. We then estimate the space-variant noise variance distribution on the image domain. Since there are many high performance denoising algorithms available for the Gaussian noise, image denoising can become much more efficient if they can be used. Hence, the authors propose a novel conversion scheme to transform the estimated space-variant noise to near Gaussian noise. In the suggested scheme, the authors first convert the image so that its mean and variance can have a linear relationship, and then produce a Gaussian image via variance stabilizing transform. The authors then apply a block matching 4D algorithm that is optimized for noise reduction of the Gaussian image, and reconvert the result to obtain a final denoised image. To examine the performance of the proposed method, an XCAT phantom simulation and a physical phantom experiment were conducted. Results: Both simulation and experimental results show that, unlike the existing denoising algorithms, the proposed algorithm can effectively reduce the noise over the whole region of CT images while preventing degradation of image resolution. Conclusions: To effectively denoise polychromatic low-dose CT images, a novel denoising algorithm is proposed. Because this algorithm is based on the noise statistics of a reconstructed polychromatic CT image, the spatially varying noise on the image is effectively reduced so that the denoised image will have homogeneous quality over the image domain. Through a simulation and a real experiment, it is verified that the proposed algorithm can deliver considerably better performance compared to the existing denoising algorithms.

60 APPLIED LIFE SCIENCES↗

Insufficiency Fractures After Pelvic Radiotherapy in Patients With Prostate Cancer

Purpose: To assess the incidence, predisposing factors, and clinical characteristics of insufficiency fractures (IF) in patients with prostate cancer, who received pelvic radiotherapy as part of their definitive treatment. Methods and Materials: The charts of 134 prostate cancer patients, who were treated with pelvic radiotherapy between 1998 and 2007 were retrospectively reviewed. IF was diagnosed by bone scan and/or CT and/or MRI. The cumulative incidence of symptomatic IF was estimated by actuarial methods. Results: Eight patients were identified with symptomatic IF after a median follow-up period of 68 months (range, 12-116 months). The 5-year cumulative incidence of symptomatic IF was 6.8%. All patients presented with lower back pain. Insufficiency fracture developed at a median time of 20 months after the end of radiotherapy and was managed conservatively without any need for hospitalization. Three patients were thought to have metastatic disease because of increased uptake in their bone scans. However, subsequent CT and MR imaging revealed characteristic changes of IF, avoiding any further intervention. No predisposing factors for development of IF could be identified. Conclusions: Pelvic IF is a rare complication of pelvic radiotherapy in prostate cancer. Knowledge of pelvic IF is essential to rule out metastatic disease and prevent unnecessary treatment, especially in a patient cohort with high-risk features for distant spread.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Beam hardening and smoothing correction effects on performance of micro-ct SkyScan 1173 for imaging low contrast density materials

We have designed and fabricated phantom mimicking breast cancer composition known as a region that has low contrast density. The used compositions are a microcalcifications, fatty tissues and tumor mass by using Al{sub 2}O{sub 3}, C{sub 27}H{sub 46}O, and hard nylon materials. Besides, phantom also has a part to calculate low cost criteria /CNR (Contrast to Noise Ratio). Uniformity will be measured at water distillation medium located in a part of phantom scale contrast. Phantom will be imaged by using micro ct-sky scan 1173 high energy type, and then also can be quantified CT number to examine SkyScan 1173 performance in imaging low contrast density materials. Evaluation of CT number is done at technique configuration parameter using voltage of 30 kV, exposure 0.160 mAs, and camera resolution 560x560 pixel, the effect of image quality to reconstruction process is evaluated by varying image processing parameters in the form of beam hardening corrections with amount of 25%, 66% and100% with each smoothing level S10,S2 and S7. To obtain the better high quality image, the adjustment of beam hardening correction should be 66% and smoothing level reach maximal value at level 10.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗