Comparative lubrication studies of OH-58A tail rotor drive shaft bearings

Comparative lubrication tests were run with OH-58A helicopter tail rotor drive shaft bearings. The tests were run in an outdoor environment with ambient temperatures ranging from 10 to 75 F. Dust was periodically applied to the bearings to simulate field conditions. The cause of bearing failure was associated with dust penetration. Rotor shaft failure was found to be caused by the shaft rotating in the standard rubber collar due to seizure of the bearings. Bearings with a positive rubbing seal having a MIL-G-81322 grease produced lives greater than with bearings having labyrinth seals and a mineral oil paste lubricant. An elongated collar prevented failure of the rotor shaft during bearing seizure. In a limited test, installation of tail boom shrouds over the bearings which excluded dust and water resulted in bearing lives in excess of 1800 hours or 1200 hours greater than the current 600 hours TBO, regardless of the lubricant-bearing combination used.

Dietrich, M. W.↗

Delta launch vehicle isogrid structure NASTRAN analysis

Structural analysis applications of NASTRAN to the isogrid structure of the Delta launch vehicle are discussed. Isogrid is a method employed to stiffen the booster cylindrical shell surface by integrally machining ribs and skin from one piece of metal. The ribs are arranged in a repetitive equilateral triangular pattern; this results in a structural surface whose stiffness is orthogonally isotopic. For that structure, both static and general instability buckling analyses are described and the theoretical results are compared to test data. One of the parameters included in the analysis is the effect of pressure loadings on the buckling allowable load. In addition, a description of a supplementary computer program is presented.

Knighton, D. J.↗

Quiet engine demonstration

A description of the performance test to compare noise output from a quiet engine with acoustic nacelle to the noise output of the JT3D turbofan engine is presented. Tabulations depict comparative thrusts, bypass ratios, core jet velocities, and fan jet velocities for both engines during simulated takeoff and approach performances.

Bloomer, H. E.↗

Study of inducer load and stress, volume 2

A program of analysis, design, fabrication and testing has been conducted to develop computer programs for predicting rocket engine turbopump inducer hydrodynamic loading, stress magnitude and distribution, and vibration characteristics. Methods of predicting blade loading, stress, and vibration characteristics were selected from a literature search and used as a basis for the computer programs. An inducer, representative of typical rocket engine inducers, was designed, fabricated, and tested with special instrumentation selected to provide measurements of blade surface pressures and stresses. Data from the tests were compared with predicted values and the computer programs were revised as required to improve correlation. For Volume 1 see N71-20403. For Volume 2 see N71-20404.

Source record↗

Application of compressibility correction to calculation of flow in inlets.

An application of the compressibility correction developed by Lieblein and Stockman (1972) to the calculation of flow in axisymmetric inlets is described. The results with experimental data from wind tunnel model tests are compared. The configuration is a conventional subsonic inlet with a NACA series one external cowl shape and a two-to-one ellipse internal lip. It is shown that the compressibility correction gives a relatively good approximation to the internal compressible flow behavior, and thus should be useful in the design and analysis of engine nacelle inlets.

Albers, J. A.↗

Two-dimensional cold-air cascade study of a film-cooled turbine stator blade. 1: Experimental results of pressure-surface film cooling tests

The effect of film coolant ejection from the pressure side of a stator blade was determined in a two-dimensional cascade. Stator exit surveys were made for each of six rows of coolant holes. Successive multirow tests were made with two, three, four, five, and six rows of coolant holes open. The results of the multirow tests are compared with the predicted multirow performance obtained by adding the single-row data. Results are presented in terms of stator primary-air efficiency as a function of coolant fraction.

Moffitt, T. P.↗

Combined effects of hydrazine exposure and endurance testing on solenoid-actuated valve performance

Results are presented from a test program which was conducted to assess the capability of various solenoid-actuated valve design concepts to provide performance characteristics commensurate with long-duration (ten-year) missions to explore the outer planets. The valves were installed in a hydrazine flow test setup and periodically cycled during a nine-month test period under test conditions comparable to anticipated mission operating conditions. In situ valve performance was periodically determined, and leakage was continuously monitored.

Hagler, R., Jr.↗

M558 radioactive tracer diffusion

This experiment was performed in Skylab 3 with two objectives in mind. First, the experimental self-diffusion coefficients for liquid zinc were to be determined in a convection-free environment. Secondly the reduction in convective mixing in earth gravity by going into the zero-gravity environment of space was to be estimated. The experiment was designed to utilize high temperatures and linear thermal gradients provided by the M518 Multipurpose Electric Furnace, and the radioactivity of zinc-65 of 245-day half-life to investigate self-diffusion in liquid zinc. The distribution of zinc-65 tracer, after melting, maintaining at soak temperature for 1 hour of soak time and then resolidifying, was obtained by sample sectioning. The concentration of activity of each section (microcurie-gram) was plotted against positions along the sample axial and radial position. Experimental data and theoretical results from solution of Fick's law of diffusion in one dimensional were compared. Samples tested on earth showed very rapid diffusion. Diffusion coefficient in unit gravity was 50 times the zero-gravity diffusion coefficient of Skylab.

Ukanwa, A. O.↗

Mapping soils, crops, and rangelands by machine analysis of multitemporal ERTS-1 data

ERTS-1 data, obtained during the period 25 August 1972 to 5 September 1973 over a range of test sites in the Central United States, have been used for identifying and mapping differences in soil patterns, species and conditions of cultivated crops, and conditions of rangelands. Multispectral scanner data from multiple ERTS passes over certain test sites have provided the opportunity to study temporal changes in the scene. Multispectral classifications delineating soils boundaries in different test sites compared well with existing soil association maps prepared by conventional means. Spectral analysis of ERTS data was used to identify, maps, and make areal measurements of wheat in western Kansas. Multispectral analysis of ERTS-1 data provided patterns in rangelands which can be related to soils differences, range management practices, and the extent of infestation of grasslands by mesquite (prosopis fuliflora) and juniper (juniperus spp.).

Baumgardner, M. F.↗

Design, manufacture, development, test, and evaluation of boron/aluminum structural components for space shuttle. Volume 4: Repairability

The repairability of boron/aluminum structural components was investigated. It was demonstrated that metal matrix composite material, damaged in service, can be repaired by techniques that are not very different from those currently in use for conventional materials. A list of repair guidelines was prepared to aid in determining the proper repair techniques for a given structure. The guidelines include specifying types of repair material and their applicability, corrosion prevention procedures, design criteria, and inspection criteria. Boron/aluminum structural components were repaired and tested to compare as-fabricated and repaired performance. All but one set of specimens, when repaired, exceeded the strength of the original specimens.

Miller, M. F.↗

Liquid rocket propellant feedline dynamics

An analytical and experimental study of liquid rocket propellant feedline dynamics has been performed. The analytical model, which includes the effects of turbulent flow, distributed and local compliances, bellows, side branches, and structural mounting stiffness, was verified by an experimental program. Water was used as the internal fluid and the dynamic perturbations in pressure and flow were created by a piston pulser. Measurements were made to determine the pressure perturbation amplitude and phase at the line terminal due to a sinusoidal pulser excitation. The frequency response of the various line configurations tested were compared with the computed theoretical results.

Holster, J. L.↗

Bistatic scatter from rain

An experimental investigation of bistatic scatter from rain was conducted, using a 143-km scatter path at frequencies of 4.5 and 7.7 GHz. The ratio of transmitted to received power (transmission loss) was measured for scattering angles ranging from 6 to 130 deg. Simultaneous weather radar observations were made at a frequency of 1.3 GHz. Transmission loss estimates for the bistatic scatter path were computed, using the weather radar data, the bistatic radar equation, and a model for the scattering cross section per unit volume of rain based upon Rayleigh scattering by an ensemble of water spheres. The measured and estimated transmission loss values were compared to test the use of the scattering model for the estimation of interference. The averaged ratio of measured-to-calculated transmission loss for the 4.5 GHz data is 1.2 plus or minus 0.4 dB. The averaged ratio for the 7.7 GHz data is -1.6 plus or minus 0.5 dB.

Crane, R. K.↗

Elastic torsional buckling of thin-walled composite cylinders

The elastic torsional buckling strength has been determined experimentally for thin-walled cylinders fabricated with glass/epoxy, boron/epoxy, and graphite/epoxy composite materials and composite-reinforced aluminum and titanium. Cylinders have been tested with several unidirectional-ply orientations and several cross-ply layups. Specimens were designed with diameter-to-thickness ratios of approximately 150 and 300 and in two lengths of 10 in. and 20 in. The results of these tests were compared with the buckling strengths predicted by the torsional buckling analysis of Chao.

Marlowe, D. E.↗

Fast response vanes for sensing flow patterns in helicopter rotor environment

Wind tunnel experiments were conducted on four small-scale flow-direction vanes for the determination of aerodynamic response. The tests were further extended to include a standard sized low-inertia vane currently employed in aircraft flight testing. The four test vanes had different aspect ratios and were about 35 percent of the surface area of the standard vane. The test results indicate satisfactory damping and frequency response for all vanes tested and compare favorably with the standard design.

Barna, P. S.↗

Two dimensional cold air cascade study of a film cooled turbine stator blade. 2: Experimental results of full film cooling tests

The effect of full film cooling on the performance of a turbine stator blade was studied in a two-dimensional cascade. The blade contained 12 rows of coolant holes, 6 rows on the suction surface and 6 on the pressure surface. Separate tests were first made with coolant ejection from each of the 12 rows. Then successive tests were made with various combinations of coolant rows open, including full film cooling. The principal results are presented in terms of primary-air efficiency as a function of coolant fraction. In addition, the efficiency results of the multirow tests are compared with the multi-row efficiency predicted by adding the single-row results.

Prust, H. W., Jr.↗

Fracture mechanics analysis of a high-pressure hydrogen facility compressor

The investigation and analysis of a high-pressure hydrogen facility compressor is chronicled, and a life prediction based on fracture mechanics is presented. Crack growth rates in SA 105 Gr II steel are developed for the condition of sustained loading, using a hypothesis of hydrogen embrittlement associated with plastic zone reverse yielding. The resultant formula is compared with test data obtained from laboratory specimens.

Vroman, G. A.↗

Dynamic Capacity and Surface Fatigue Life for Spur and Helical Gears

A mathematical model for surface fatigue life of gear, pinion, or entire meshing gear train is given. The theory is based on a previous statistical approach for rolling-element bearings. Equations are presented which give the dynamic capacity of the gear set. The dynamic capacity is the transmitted tangential load which gives a 90 percent probability of survival of the gear set for one million pinion revolutions. The analytical results are compared with test data for a set of AISI 9310 spur gears operating at a maximum Hertz stress of 1.71 billion N/sq m and 10,000 rpm. The theoretical life predictions are shown to be good when material constants obtained from rolling-element bearing tests were used in the gear life model.

Coy, J. J.↗

Initial comparisons of solar collector performance data obtained out-of doors and with a solar simulator

A facility was constructed to evaluate solar collector performance outdoors for conditions that would be encountered by collectors if they were incorporated in a solar heating/cooling system. In addition to obtaining initial collector performance data, the outdoor facility will enable collector durability and degradation rates to be evaluated for operating periods of several months. The data obtained from the outdoor tests were compared to collector performance predicted on the basis of results obtained with a solar simulator. The performance measured outdoors was less than the predicted performance.

Vernon, R. W.↗