Intelligent Monitoring System for Real-time Geologic Storage, Optimization, and Reservoir Management

The objective of the subtask was to develop a near-real-time monitoring system for seismic data at the Decatur, IL, geologic carbon sequestration (GCS) site and specifically include fiber-optic cable derived distributed acoustic signal (DAS) data in the process. Owing to the large volumes of data, we opted to utilize existing deep borehole conventional seismic sensors for detection and pull DAS and shallow borehole seismic data once a detection has been made. Unfortunately, the horizontal fiber-optic cables did not yield microseismic signals for use in locating events near the GCS site. Various stacking and filtering approaches were tested without any coherent detection becoming apparent. We attribute the insensitivity to local microseismic events to a lack of coupling in downhole, vertical cable and the non-ideal alignment of the horizontal fiber-optic cable to the vertically polarized seismic energy. Despite the inability to detect and utilize the DAS data from the fiber-optic cables, we developed a general processing framework that enables easy adaptation for future deployment of fiber-optic cables with better suited alignment at Decatur or elsewhere.

Kaven, J. Ole↗

Return on Investment and Sustainability of HVDC Links: Role of Diagnostics, Condition Monitoring, and Material Innovations

HVDC cable systems are becoming an upscaled technical option, compared to AC, because of various factors, including easier interconnections, lower losses, and longer transmission distances. In addition, renewables providing direct DC energy, electrified transportation, and aerospace where DC can be favored because of higher carried specific power all point in the direction of broad future usage of HV and MV DC links. However, contrary to AC, there is little return from on-field installation as regards long-term cable reliability and aging processes. This gap must be covered by intensive research, and contributing to this research is the purpose of this paper. The focus is on key points for HVDC (and MVDC) cable reliability and sustainability, from design modeling able to account for voltage transients and extrinsic aging (such as that caused by partial discharges) to the impact of aging on insulation conductivity (which rules the electric field distribution, thus aging rate). Also, recyclable and nanostructured materials, as well as health conditions, are considered. It is shown how cable design can account for accelerated aging due to voltage transients, as well as for aging-time dependence of conductivity, and how design can be free of extrinsic aging caused by PDs. Algorithms for health condition evaluations, which have additional value in a relatively new technology such as HVDC polymeric cables, are applied to insulation system aging under partial discharges, showing how they can provide an indication of insulation degradation globally or locally (weak spots) and of possible maintenance times. All of this can effectively contribute to reducing the risk of major cable breakdown and damage under operation, which would significantly affect the return on investment (ROI).

Montanari, Gian Carlo (ORCID:0000000320258693)↗

System for Measuring Capacitance

A system has been developed for detecting the level of a liquid in a tank wherein a capacitor positioned in the tank has spaced plates which are positioned such that the dielectric between the plates will be either air or the liquid, depending on the depth of the liquid in the tank. An oscillator supplies a sine wave current to the capacitor and a coaxial cable connects the capacitor to a measuring circuit outside the tank. If the cable is very long or the capacitance to be measured is low, the capacitance inherent in the coaxial cable will prevent an accurate reading. To avoid this problem, an inductor is connected across the cable to form with the capacitance of the cable a parallel resonant circuit. The impedance of the parallel resonant circuit is infinite, so that attenuation of the measurement signal by the stray cable capacitance is avoided.

McNichol, Randal S.↗

Ice-Borehole Probe

An instrumentation system has been developed for studying interactions between a glacier or ice sheet and the underlying rock and/or soil. Prior borehole imaging systems have been used in well-drilling and mineral-exploration applications and for studying relatively thin valley glaciers, but have not been used for studying thick ice sheets like those of Antarctica. The system includes a cylindrical imaging probe that is lowered into a hole that has been bored through the ice to the ice/bedrock interface by use of an established hot-water-jet technique. The images acquired by the cameras yield information on the movement of the ice relative to the bedrock and on visible features of the lower structure of the ice sheet, including ice layers formed at different times, bubbles, and mineralogical inclusions. At the time of reporting the information for this article, the system was just deployed in two boreholes on the Amery ice shelf in East Antarctica and after successful 2000 2001 deployments in 4 boreholes at Ice Stream C, West Antarctica, and in 2002 at Black Rapids Glacier, Alaska. The probe is designed to operate at temperatures from 40 to +40 C and to withstand the cold, wet, high-pressure [130-atm (13.20-MPa)] environment at the bottom of a water-filled borehole in ice as deep as 1.6 km. A current version is being outfitted to service 2.4-km-deep boreholes at the Rutford Ice Stream in West Antarctica. The probe (see figure) contains a sidelooking charge-coupled-device (CCD) camera that generates both a real-time analog video signal and a sequence of still-image data, and contains a digital videotape recorder. The probe also contains a downward-looking CCD analog video camera, plus halogen lamps to illuminate the fields of view of both cameras. The analog video outputs of the cameras are converted to optical signals that are transmitted to a surface station via optical fibers in a cable. Electric power is supplied to the probe through wires in the cable at a potential of 170 VDC. A DC-to-DC converter steps the supply down to 12 VDC for the lights, cameras, and image-data-transmission circuitry. Heat generated by dissipation of electric power in the probe is removed simply by conduction through the probe housing to the visible features of the lower structure of the ice sheet, including ice layers formed at different times, bubbles, and mineralogical inclusions. At the time of reporting the information for this article, the system was just deployed in two boreholes on the Amery ice shelf in East Antarctica and after successful 2000 2001 deployments in 4 boreholes at Ice Stream C, West Antarctica, and in 2002 at Black Rapids Glacier, Alaska. The probe is designed to operate at temperatures from 40 to +40 C and to withstand the cold, wet, high-pressure [130-atm (13.20-MPa)] environment at the bottom of a water-filled borehole in ice as deep as 1.6 km. A current version is being outfitted to service 2.4-km-deep boreholes at the Rutford Ice Stream in West Antarctica. The probe (see figure) contains a sidelooking charge-coupled-device (CCD) camera that generates both a real-time analog video signal and a sequence of still-image data, and contains a digital videotape recorder. The probe also contains a downward-looking CCD analog video camera, plus halogen lamps to illuminate the fields of view of both cameras. The analog video outputs of the cameras are converted to optical signals that are transmitted to a surface station via optical fibers in a cable. Electric power is supplied to the probe through wires in the cable at a potential of 170 VDC. A DC-to-DC converter steps the supply down to 12 VDC for the lights, cameras, and image-datatransmission circuitry. Heat generated by dissipation of electric power in the probe is removed simply by conduction through the probe housing to the visible features of the lower structure of the ice sheet, including ice layers formed at different times, bubbles, and mineralogical inclusions. At thime of reporting the information for this article, the system was just deployed in two boreholes on the Amery ice shelf in East Antarctica and after successful 2000 2001 deployments in 4 boreholes at Ice Stream C, West Antarctica, and in 2002 at Black Rapids Glacier, Alaska. The probe is designed to operate at temperatures from 40 to +40 C and to withstand the cold, wet, high-pressure [130-atm (13.20-MPa)] environment at the bottom of a water-filled borehole in ice as deep as 1.6 km. A current version is being outfitted to service 2.4-km-deep boreholes at the Rutford Ice Stream in West Antarctica. The probe (see figure) contains a sidelooking charge-coupled-device (CCD) camera that generates both a real-time analog video signal and a sequence of still-image data, and contains a digital videotape recorder. The probe also contains a downward-looking CCD analog video camera, plus halogen lamps to illuminate the fields of view of both cameras. The analog video outputs of the cameras are converted to optical signals that are transmitted to a surface station via optical fibers in a cable. Electric power is supplied to the probe through wires in the cable at a potential of 170 VDC. A DC-to-DC converter steps the supply down to 12 VDC for the lights, cameras, and image-datatransmission circuitry. Heat generated by dissipation of electric power in the probe is removed simply by conduction through the probe housing to the adjacent water and ice.

Behar, Alberto↗

Electrically Small Microstrip Quarter-Wave Monopole Antennas

Microstrip-patch-style antennas that generate monopole radiation patterns similar to those of quarter-wave whip antennas can be designed to have dimensions smaller than those needed heretofore for this purpose, by taking advantage of a feed configuration different from the conventional one. The large sizes necessitated by the conventional feed configuration have, until now, made such antennas impractical for frequencies below about 800 MHz: for example, at 200 MHz, the conventional feed configuration necessitates a patch diameter of about 8 ft (.2.4 m) . too large, for example, for mounting on the roof of an automobile or on a small or medium-size aircraft. By making it possible to reduce diameters to between a tenth and a third of that necessitated by the conventional feed configuration, the modified configuration makes it possible to install such antennas in places where they could not previously be installed and thereby helps to realize the potential advantages (concealment and/or reduction of aerodynamic drag) of microstrip versus whip antennas. In both the conventional approach and the innovative approach, a microstrip-patch (or microstrip-patch-style) antenna for generating a monopole radiation pattern includes an electrically conductive patch or plate separated from an electrically conductive ground plane by a layer of electrically insulating material. In the conventional approach, the electrically insulating layer is typically a printed-circuit board about 1/16 in. (.1.6 mm) thick. Ordinarily, a coaxial cable from a transmitter, receiver, or transceiver is attached at the center on the ground-plane side, the shield of the cable being electrically connected to the ground plane. In the conventional approach, the coaxial cable is mated with a connector mounted on the ground plane. The center pin of this connector connects to the center of the coaxial cable and passes through a hole in the ground plane and a small hole in the insulating layer and then connects with the patch above one-third of the radial distance from the center. The modified feed configuration of the innovative approach is an inductive-short-circuit configuration that provides impedance matching and that has been used for many years on other antennas but not on microstrip-style monopole antennas. In this configuration, the pin is connected to both the conductive patch and the ground plane. As before, the shield of the coaxial cable is connected to the ground plane, but now the central conductor is connected to a point on the pin between the ground plane and the conductive plate (see figure). The location of the connection point on the pin is chosen so that together, the inductive short circuit and the conductive plate or patch act as components of a lumped-element resonant circuit that radiates efficiently at the resonance frequency and, at the resonance frequency, has an impedance that matches that of the coaxial cable. It should be noted that the innovative design entails two significant disadvantages. One disadvantage is that the frequency bandwidth for efficient operation is only about 1/20 to 1/15 that of a whip antenna designed for the same nominal frequency. The other disadvantage is that the estimated gain is between 3-1/2 and 4-1/2 dB below that of the whip antenna. However, if an affected radio-communication system used only a few adjacent frequency channels and the design of the components of the system other than the antenna provided adequate power or gain margin, then these disadvantages could be overcome.

Young, W. Robert↗

Evaluate Techniques for Penetrating a Shielded Enclosure Using Twisted Pair Wire

The aim of this project is to demonstrate techniques for effectively penetrating a radio shielded enclosure using Ethernet cable (CAT-6). This process requires that we measure the shielding performance by means of testing and data orchestration to collect and analyze our data to present observations with different test cases. Each test case would represent a different penetration strategy that utilizes distinctive wire coupling and characteristics (i.e. the type of bulkhead link, the twist of each CAT-6 cable, the shielding type of each CAT-6 cable, and the length of the cable). As the different cable setups are fabricated a prototype evaluation of setup is conducted to measure the signal integrity of our testing configuration. Our signal integrity is measured through the analysis of different parameters found in the prototype evaluation such as RF leakage, impedance mismatch, and decay rate. As each of these data values are effectively collected and analyzed the most effective cable setup is selected based upon its ability to penetrate the shielded enclosure. The testing data is compared in conjunction with the cost of the manufacturing of the prototype wire penetration.

St. Julian, Christopher↗

Detectors Ensure Function, Safety of Aircraft Wiring

Pedro Medelius waited patiently in his lab at Kennedy Space Center. He had just received word that a colleague was bringing over a cable from a Space Shuttle solid rocket booster to test Medelius new invention. Medelius was calm until his colleague arrived, with about 30 other people. "Talk about testing under pressure," says Medelius. "There were people there from the Navy, the Air Force, and the Federal Aviation Administration." After the group s arrival, Medelius took a deep breath and connected his Standing Wave Reflectometer (SWR) to the cable. He wiggled the cable around, and the display showed a fault (a short or open circuit in wire) about an inch and a half inside the connector on the cable. His colleague questioned the results, because he had already checked that area on the cable. Medelius used the SWR to check again but got the same result. "That is when we took the cable apart and looked inside," Medelius says. "Lo and behold, that was exactly where the fault was." The impetus for Medelius new wire inspection technology came about in 1999 when one of the space shuttles lost power due to a fault somewhere in its more than 200 miles of electrical wiring. "The backup circuit was activated and prevented a major dysfunction, but nevertheless, there was a problem with the wiring," Medelius describes. Even though technicians used a device called a multimeter to measure the electrical current to find which wire had a fault, it could not pinpoint exactly where on the wire the fault was located. For that, technicians had to visually inspect the wire. "Sometimes they would have to remove the whole wire assembly and visually inspect every single wire. It was a very tedious operation because the wires are behind cabinets. They go all over the place in the shuttle," says Medelius. "NASA needed an instrument capable of telling them exactly where the faults were occurring." To meet NASA s needs for a highly precise device to inspect electrical power bundles, wires, and connectors, Medelius devised the SWR. "It came down to what was affected when a wire is short circuited or opened," he says. "We worked out a few equations based on physical principles." The SWR proved very sensitive, and the technology was patented.

Source record↗

Regolith Particle Erosion of Material in Aerospace Environments

This paper studies the effect of exposing thermal control S13GP:6N/LO-I white paint, Kapton flex cable, fiber optic cable, HEPA filter, and M55J graphite composite to high-velocity regolith environment that spacecraft landing on Mars are commonly exposed to. Due to the similarity between the Mars 2020 Rover design and Mars Science Laboratory design, it is expected that the Mars 2020 rover will be exposed to a similar high-speed regolith environment that the Mars Science Laboratory was exposed to. This environment is replicated to test the survivability of susceptible materials. The testing is performed at the University of Dayton Research Institute in Dayton, Ohio. The experiments expose different materials to basaltic–like particles ranging in size from approximately 40 μm to 2 cm, at velocities ranging from 19 m/s to 250 m/s, with varied particle fluxes (measured in mg/cm2). Depending on the size of the particle used, the particles can either embed in or erode the material. Posttest analysis shows that all materials tested will survive the expected environment observed during the Mars 2020 landing event. Some materials are tested to failure in order to better characterize material response. Materials that fail in some test scenarios include the paint, fiber optic cable, and the graphite composite. After being exposed to regolith, the α/ε ratio of the paint increased by ~37% due to particles embedding in the paint. Darkening of the paint can negatively affect thermal control of the rover. With high particle mass fluxes, the paint eventually degraded enough to expose the aluminum substrate. When impacted by a 1.5 cm particle traveling at 20 m/s, the fiber optic cable did not sever, but the impact did cause the cable to deform enough to crack the glass, which resulted in a significant increase in attenuation, rendering the cable unable to transmit data. The graphite composite also failed when exposed to high particle fluxes. All of the observed failures occurred for test cases above the expected landing environment with significant margin. Tests performed beyond the requirements help characterize how well these materials will survive in even more extreme environments for future missions.

Abid, Mohamed↗

Human Stability While Exercising on a VIS Device in Zero Gravity

BACKGROUND: A Vibration Isolation and Stabilization (VIS) system is being designed for use with the European Enhanced Exploration Exercise Device (E4D) [1]. The exercise bar is attached to cables that extend and retract through openings in the E4D platform, which the subject stands on while exercising. Since the E4D is mounted on a moving VIS device, the whole system moves under the subject’s feet. While tension in the cables does help stabilize a crew member in 0g by bracing him or her against the moving platform, flexible cables do not offer full support against falling. This raises the question of whether various exercises that are successfully performed in 1g on a stationary device can be performed without losing balance in 0g on a moving device. Quantifying stability conditions and establishing stability requirements for exercise countermeasure systems is a long-standing challenge and this work helped to inform this specific need for integrated E4D/VIS flight project development. METHODS AND RESULTS: A simplified stability analysis can be attempted based on platform accelerations generated by the VIS device simulation. In this type of analysis, the subject is conceived as standing on the platform in 0g while being held down to it by the tension in the cables. If the sideways acceleration of the platform is such that the cables cannot generate a sufficient moment relative to, e.g., the heels or the toes of the subject to overcome the tipping moment from the inertial forces on the accelerated subject’s body, the subject becomes unstable. This approach, which we refer to as the ‘static’ approximation, indicated failure of all the exercises that were considered in the comprehensive VIS analysis of the E4D. It was realized, however, that platform accelerations are not externally imposed but are themselves induced by the motion of the subject’s body during exercise, and a model calculation confirmed that this drastically altered the tipping moment on the subject, with the potential to even switch the direction in which the body would tip over. This made it imperative to consider in a coupled manner both the motion of the exercising subject’s body and the induced VIS platform motion while considering stability. The coupled dynamics requirement was met by the VIS simulation incorporating time-dependent human mass properties atop the platform and driven by the inertial forces from the prescribed subject motion relative to the platform based on motion-capture recorded human trajectories in 1g on a stationary E4D [2]. To analyze simulation results, a stability criterion was also needed. We do not know how to account for the human ‘control system’ that would take visual and vestibular cues as inputs as the platform moves in 0g. We thus chose to follow an approach we had previously used to analyze the dynamic feasibility of performing a task in lunar gravity along the human body trajectory recorded in 1g [3]. In this approach, one analyzes the center of pressure (COP) between the shoes and the ground (or platform) and checks if the COP remains within the convex hull of the footprints on the ground (or platform), commonly referred to as base of support (BOS). Since pressure is vertical and, in the absence of foot restraints, positive, the COP going outside the BOS indicates that the trajectory recorded in 1g is not dynamically feasible in microgravity and/or on the moving platform of the device. The outcome of the COP-based analysis was that some of the key exercises, especially the deadlift and the back squat exercises, were found to be dynamically feasible for at least some number of the exercise cycles, this number increasing with the cable tension. While this type of stability analysis does not account for the likely alteration of the exercise trajectory from its 1g form in space, it does show that there exist at least some realistic trajectories that pass the dynamic feasibility criterion. This adds confidence that, with further adjustment by the subject of the exercise form in 0g on a moving device, a number of exercises can be performed without losing balance.

D Frenkel↗

Space Launch System (SLS) Human Factors Engineering Modeling & Analysis

The Human Systems Integration & Engineering (HSI&E) team at NASA’s Marshall Space Flight Center (MSFC) strives to advocate for the humans in the loop of Space Launch System’s (SLS) ground operations. Using assessment methods like human simulation, virtual reality, and physical mockups, both flight hardware and ground support equipment (GSE) are evaluated for human integration. Those ranging from 5th percentile female (approximately 5’2” tall) to 95th percentile male (approximately 6’2” tall) should be able to perform all SLS stacking operations. Operations include element physical mates, element electrical mates, and testing activities. The primary human simulation software used is Process Simulate Human (PSH) made by Siemens. This software supplies highly accurate human manikins that can interact with CAD models. PSH was used to evaluate the Transportation and Integration Platform’s (TIP) side opening that was designed for access to the Payload Adapter (PLA) cables. Technicians will need to access these cables for testing purposes before element stacking at Kennedy Space Center (KSC). After performing an analysis in PSH using the TIP side opening, it was found that neither a 5th percentile female or a 95th percentile male could perform the task as the designers had intended. There is a C-beam that blocks access to the cables (both physically and visually). An alternative analysis was performed using PSH to look at another access point to the PLA cables. Although this method would disrupt already established procedures and produce more work, the designers confirmed it was an option. Instead of technicians accessing the cables through the side opening in the TIP, a human simulation was performed for going through a panel opening in the bottom of the TIP. This method requires removal of a TIP panel and a stepladder of at least 36 inches for a 5th percentile female to access the cables.

human factors↗

ACCELERATED THERMAL AGING OF HARVESTED HYPALON JACKET FOR REMAINING USEFUL LIFE DETERMINATION AND DIAGNOSIS

For nuclear power plants (NPPs) that are considering second license renewal for their operation beyond 60 years, knowledge of long-term operation, condition monitoring, and viability for the reactor components including reactor pressure vessel, concrete structures, and cable systems is essential. Such knowledge will provide NPPs with a game plan to predict performance and to estimate costs that are associated with monitoring or replacement programs for the affected systems. For cable systems that encompass a wide variety of materials, manufacturers, and in-plant location, accelerated aging of harvested cable jacket and insulation can provide insight as to remaining useful life and methods for monitoring. Accelerated thermal aging in air at temperatures between 80°C and 120°C was carried out on a multi-conductor control rod cable that had been in-service for over 30 years and was made by Boston Insulated Wire with Hypalon cable jacket and ethylene-propylene rubber insulation. From elongation at break (EAB) measurements and supporting Arrhenius analysis of the jacket material, an activation energy of 97.84 kJ/mol was estimated and the time to degradation, as represented by 50% EAB at the expected maximum operating temperature of 45°C, was estimated as consistent with 80 years. These values were slightly below previous measurements and could either be attributed to in-service degradation or variations in material properties from a given manufacturer. In addition, results from indenter modulus measurements and Fourier transform infrared spectroscopy suggest possible markers that could be beneficial to monitor cable conditions.

Glass III, Samuel W.↗

ELECTRICAL BREAKDOWN STRENGTH AND AC WITHSTAND IN HARVESTED EPR INSULATIONS FOR NUCLEAR POWER PLANTS

While the operating voltages for some instrument and control (I&C) cables can be greater than 4 kV to operate pumps, controls, and provide auxiliary power, the operating voltage for most I&C cables is near 600 V. Although the electrical stress is not nearly as high in the insulation of these cables, an ac withstand two and one-half times greater than the operating voltage after a simulated design basis exposure (DBE) has been used in environmental qualification (EQ) to determine the ability of an insulation to meet a 40-year lifetime at an operating voltage. While multiple cable lengths greater than 10 feet are needed to replicate this EQ, systematic measurement of the electrical insulation strength in harvested cable insulations can be beneficial to better understand the remaining useful life of the insulation. This understanding can only be realized through systematic comparison to some level of DBE, and electrical insulation strength measurement can provide a baseline for comparison with other mechanical, chemical, and electrical characterizations that have been utilized. Accelerated aging of two types of ethylene propylene rubber (EPR) insulations from harvested cables was carried out, and the electrical breakdown strength and indenter modulus for both insulations were determined. Results showed that degradation of electrical breakdown strength occurred in only one type of BIW insulation and that this degradation did track with that measured by indenter modulus. The methodology for using Weibull statistics for electrical breakdown strength relative to time to failure is discussed.

Duckworth, Robert↗

Vertical Extraction Process Implemented at the 118-K-1 Burial Ground for Removal of Irradiated Reactor Debris from Silo Structures - 12431

The primary objective of a remediation project is the safe extraction and disposition of diverse waste forms and materials. Remediation of a solid waste burial ground containing reactor hardware and irradiated debris involves handling waste with the potential to expose workers to significantly elevated dose rates. Therefore, a major challenge confronted by any remediation project is developing work processes that facilitate compliant waste management practices while at the same time implementing controls to protect personnel. Traditional burial ground remediation is accomplished using standard excavators to remove materials from trenches and other excavation configurations often times with minimal knowledge of waste that will be encountered at a specific location. In the case of the 118-K-1 burial ground the isotopic activity postulated in historic documents to be contained in vertical cylindrical silos was sufficient to create the potential for a significant radiation hazard to project personnel. Additionally, certain reported waste forms posed an unacceptably high potential to contaminate the surrounding environment and/or workers. Based on process knowledge, waste management requirements, historic document review, and a lack of characterization data it was determined that traditional excavation techniques applied to remediation of vertical silos would expose workers to unacceptable risk. The challenging task for the 118-K-1 burial ground remediation project team then became defining an acceptable replacement technology or modification of an existing technology to complete the silo remediation. Early characterization data provided a good tool for evaluating the location of potential high exposure rate items in the silos. Quantitative characterization was a different case and proved difficult because of the large diameter of the silos and the potential for variable density of attenuating soils and waste forms in the silo. Consequently, the most relevant information supporting job planning and understanding of the conditions was the data obtained from the gross gamma meter that was inserted into each casing to provide a rough estimate of dose rates in the tubes. No added value was realized in attempting to quantify the source term and/or associate the isotopic activity with a particular actual waste form (e.g., sludge). Implementing the WRM system allowed monitoring of worker and boundary exposure rates from a distance, maintaining compliance with ALARA principles. This system also provided the project team early knowledge of items being removed that had high exposure rates associated with them, thus creating an efficient method of acknowledging an issue and arriving at a solution prior to having an upset condition. An electronic dosimeter with telemetry capability replaced the excavator mounted AMP-100 system approximately half way through remediation of the silos. Much higher connectivity efficiency was derived from this configuration. Increasing the data feed efficiency additionally led to less interruption of the remediation effort. Early in system testing process a process handicap on the excavator operator was acknowledged. A loss of depth perception resulted when maneuvering the excavator and bucket using the camera feed to an in-cab monitor. Considerable practice and mock-up testing allowed this handicap to be overcome. The most significant equipment failures involved the cable connection to the camera mounted between the clamshell bucket jaws and the video splitter in the excavator cab. Rotation of the clamshell bucket was identified as the cause of cable connection failures because of the cyclic twisting motion and continuous mechanical jarring of the connection. In-cab vibration was identified as the culprit in causing connection failures of the video splitter. While these failures were repaired, substantial production time was lost. Ultimately, the decision was made to purchase a second cable and higher quality video splitter eliminate the down time. An engineering improvement for future operations would be inserting cable pig tails at more stressed cable connection points to facilitate rapid change out of the cable should that be required. Overall, the system performed better than expected in a safe and efficient manner. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CORRTEX Diagnostic Deployment for the SPE-III experiment, 24 July 2012: Fielding Report and Preliminary Data Analysis

The Continuous Reflectometry for Radius vs Time Experiments (CORRTEX) diagnostic system was deployed for the third explosives test in the Source Physics Experiment (SPE) sequence to monitor and verify several conditions of the experiment including the detonation velocity of the explosive package and functioning of explosive initiators. Six distance-marked coaxial cables were installed on the SPE-III explosives canister, and key locations documented through along-cable length measurements and photography. CORRTEX uses electrical-pulse time-domain reflectometry to continuously record the two-way transit time (TWTT) of the cables. As the shock front of the detonation advances, the coaxial cable is shorted or destroyed, and the resulting TWTT also decreases. Interpretation of these changes as a function of TWTT can be converted to positional measurements using known parameters of the cables.

47 OTHER INSTRUMENTATION↗

Development of in-vessel components of the microfission chamber for ITER

Microfission chambers (MFCs) will measure the total neutron source strength in ITER. The MFCs will be installed behind blanket modules in the vacuum vessel (VV). Triaxial mineral insulated (MI) cables will carry signals from the MFCs. The joint connecting triaxial MI cables in the VV must be considered because the MFCs and the MI cables will be installed separately at different times. Vacuum tight triaxial connector of the MI cable has been designed and a prototype has been constructed. Performance tests indicate that the connector can be applied to the ITER environment. A small bending-radius test of the MI cable indicates no observed damage at a curvature radius of 100 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vibration-induced electrical noise in a cryogen-free dilution refrigerator: Characterization, mitigation, and impact on qubit coherence

Cryogen-free low-temperature setups are becoming more prominent in experimental science due to their convenience and reliability, and concern about the increasing scarcity of helium as a natural resource. Despite not having any moving parts at the cold end, pulse tube cryocoolers introduce vibrations that can be detrimental to the experiments. We characterize the coupling of these vibrations to the electrical signal observed on cables installed in a cryogen-free dilution refrigerator. The dominant electrical noise is in the 5–10 kHz range and its magnitude is found to be strongly temperature dependent. We test the performance of different cables designed to diagnose and tackle the noise, and find triboelectrics to be the dominant mechanism coupling the vibrations to the electrical signal. Flattening a semi-rigid cable or jacketing a flexible cable in order to restrict movement within the cable, successfully reduces the noise level by over an order of magnitude. Furthermore, we characterize the effect of the pulse tube vibrations on an electron spin qubit device in this setup. Coherence measurements are used to map out the spectrum of the noise experienced by the qubit, revealing spectral components matching the spectral signature of the pulse tube.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced critical axial tensile strain limit of CORC ® wires: FEM and analytical modeling

Abstract Conductor on Round Core (CORC ® ) cables and wires are composed of spiraled high-temperature superconducting (HTS) rare-earth barium copper oxide (REBCO) tapes, wound in multiple layers, and can carry very high currents in background magnetic fields of more than 20 T. They combine isotropic flexibility and high resilience to electromagnetic and thermal loads. The brittle nature of HTS tapes limits the maximum allowable axial tensile strain in superconducting cables. An intrinsic tensile strain above about 0.45% will introduce cracks in the REBCO layer of straight HTS tapes resulting in irreversible damage. The helical fashion at which the REBCO tapes are wound around the central core allows tapes to experience only a fraction of the total axial tensile strain applied to the CORC ® wire. As a result, the critical strain limit of CORC ® wires can be increased by a factor of more than 10 that of REBCO tapes. Finite element (FE) and analytical models are developed to predict the performance of CORC ® wires under axial tensile strain. A parametric analysis is carried out by varying the winding angle, the Poisson’s ratio of the CORC ® wire core, the core diameter, and the tape width. The results show that a small variation in winding angle can have a significant impact on the cable’s axial tensile strain tolerance. While the radial contraction of the helically wound tapes in a CORC ® wire under axial tensile strain depends on its winding angle, it is mostly driven by the Poisson’s ratio of the central core, affecting the tape strain state and thus its performance. Contact pressure from multiple layers within the CORC ® wire also affects the CORC ® wire performance. The FE model can be used to optimize the cable design for specific application conditions, resulting in an irreversible strain limit of CORC ® cables and wires as high as 7%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Finite-Element Analysis of the Strain Distribution Due to Bending in a REBCO Coated Conductor for Canted Cosine Theta Dipole Magnet Applications

High-current cables using REBCO tapes can be used to develop high-field dipole magnets. However, the strain accumulated during cable fabrication and coil winding may reduce the critical current of the conductor. Therefore, it is important to properly consider the strain when designing high-field magnets. We used structural finite-element analysis (FEA) to predict the strain experienced by a REBCO tape during bending in configurations relevant to the fabrication of high-field accelerator magnets, in particular, the mechanical strain generated during cable fabrication and winding in a canted-cosθ dipole configuration. We considered two different cable options: (A) Flat tape that lay in the mandrel channel and (B) a REBCO tape helically wound around a circular copper core, the typical configuration of the conductor in round core cable (CORC). Strain accumulated during tape winding is studied for different core diameters and winding tilt angles. FEA longitudinal strain results were compared with the simulations for configuration A, where higher strain was observed experimentally. Configuration B was verified indirectly by comparing experimentally measured I c with the one predicted (based on the longitudinal strain) as a function of the bending diameter. Good agreement was found up to a bending diameter of 30 mm. The presented results will help to understand the impact of bending on REBCO tapes and CORC wires to develop high-field magnets.