Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building Energy Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Energy Auditor and Quality Control Inspector Competency Model

The Energy Auditor (EA) and Quality Control Inspector (QCI) Competency model was developed to identify the soft skills, foundational competencies and define the levels of Knowledge, Skills, and Abilities (KSAs) required to successfully perform the tasks defined in the EA and QCI Job Task Analysis (JTAs), the U.S. Department of Energy (DOE) used the U.S. Department of Labor's (DOL) Competency Model Clearinghouse resources to develop a QCI and EA Competency Model. To keep the QCI and EA competency model consistent with other construction and energy management competency models, DOE and the National Renewable Energy Laboratory used the existing 'Residential Construction Competency Model' and the 'Advanced Commercial Building Competency Model' where appropriate.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Identification of aggregate building thermal dynamic model and unmeasured internal heat load from data

This paper is on the problem of simultaneously identifying the parameters of an aggregate thermal dynamic model of a multi-zone building and unknown disturbances from input-output data. An aggregate model is a single-zone equivalent of a multi-zone building, and is useful for many purposes, including model based control of large heating, ventilation and air conditioning (HVAC) equipment that delivers thermal energy to the entire building. A key challenge in identification is the presence of unknown disturbance since it is not measurable but non-negligible.We first present a principled method to aggregate a multizone building model into a single zone model. We then provide a method to identify thermal parameters and the unknown disturbance for this aggregate (single-zone) model. Finally, we test our proposed identification algorithm to data generated from a virtual building. A key insight provided by the aggregation method allows us to recognize under what conditions the estimation of the disturbance signal will be necessarily poor and uncertain.

Guo, Zhong↗

Development of a topology analysis tool for fifth-generation district heating and cooling networks

Fifth generation district heating and cooling networks are characterized by supply temperatures in the ambient range of 15-25 degrees C, which not only reduces heat loss but also allows for integrating various kinds of low-temperature waste heat sources. The ability of these networks to absorb waste heat that is normally unrecoverable makes them an attractive solution for the future energy supply of urban areas. To enhance the adoption of these networks, this paper describes the development of a software tool to analyze the feasibility of fifth-generation of district heating and cooling systems in both new and existing districts. The research attempts to answer the question: 'Which buildings should be connected to a low-temperature hydraulic network given both the incremental benefits and costs relative to the scenario of decentralized (dedicated) heating and cooling systems for each building?' Therefore, all possible network layouts of the buildings are considered where the heating and cooling demands of each building are met by the fifth-generation of district heating and cooling network. For the heating and cooling load characterization of the buildings, reduced-order models are used while renewable energy and waste heat sources are included in the network. The focus of the research lies in the development of a hydraulic model for flexible use in the urban energy modeling and the optimization of the fifth-generation of district heating and cooling network topology for a given urban district. This research displays simulation results that quantify the performance of the fifth-generation of district heating and cooling network based on various output metrics, including primary energy usage, carbon dioxide emissions, and network implementation cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Public Housing: A Tailored Approach to Energy Retrofits

Over one million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 public housing authorities (PHAs) across the country indicated that there is a high level of interest in developing low-cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with four PHAs to develop packages of energy efficiency retrofit measures the PHAs can cost-effectively implement with their own staffs in the normal course of housing operations at the time when units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing, and measures that improve equipment efficiency. ARIES documented implementation in 18 housing units. Reductions in average air leakage were 16% and duct leakage reductions averaged 23%. Total source energy consumption savings due to implemented measures was estimated at 3-10% based on BEopt modeling with a simple payback of 1.6 to 2.5 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of units per year nationally.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An inverse approach to solving zone air infiltration rate and people count using indoor environmental sensor data

Physics-based simulation of energy use in buildings is typically widely used in building design and performance rating, controls design and operations. However, various challenges exist in the modeling process. Model parameters such as people count and air infiltration rate are usually highly uncertain, yet they have significant impacts on the simulation accuracy. With the increasing availability and affordability of sensors and meters in buildings, a large amount of measured data has been collected including indoor environmental parameters, such as room air dry-bulb temperature, humidity ratio, and CO 2 concentration levels. Fusing these sensor data with traditional energy modeling poses new opportunities to improve simulation accuracy. This study develops a set of physics-based inverse algorithms which can solve the highly uncertain and hard-to-measure building parameters such as zone-level people count and air infiltration rate. A simulation-based case study is conducted to verify the inverse algorithms implemented in EnergyPlus covering various sensor measurement scenarios and different modeling use cases. The developed inverse models can solve the zone people count and air infiltration at sub-hourly resolution using the measured zone air temperature, humidity and/or CO 2 concentration given other easy-to-measure model parameters are known.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical Modeling and Parametric Study of a Dual Purpose Underground Thermal Battery

Buildings’ thermal energy systems for providing space heating/cooling consume a considerable amount of electricity nationwide. Integrating thermal energy storage with buildings’ thermal systems has the potential to shave the peak electric demand and to overcome the mismatch between the intermittent renewable power and the fluctuating daily demand for electricity. A novel dual-purpose underground thermal battery (DPUTB) has been developed to provide diurnal thermal energy storage in conjunction with a dual-source heat pump (DSHP)system. A two-dimensional numerical model is developed to simulate the transient performance of the DPUTB. This model has similar accuracy as a detailed three-dimensional model developed with commercial heat transfer and fluid dynamics simulation program but with 1000 times faster computational speed. A parametric study is performed to identify a design of the DPUTB that can provide 14 kWh thermal storage capacity for each charging and discharging cycle. A system simulation has been developed to assess the performance of the designed DPUTB when it is integrated with a DSHP for conditioning a typical residential building in summer and winter. Simulation results indicate that the DPUTB can meet all the design requirements in both summer and winter with the simple rule-based control strategy and the overall integrated DPUTB and DSHP system can shift the electric load for meeting the thermal demand from the peak hours to off-peak hours during a day, which would result in considerable energy cost savings if a Time of Use electricity tariff is applicable.

25 ENERGY STORAGE↗

Home Energy Scoring Tools (website) and Application Programming Interfaces, APIs (aka HEScore)

A web-based residential energy rating tool with APIs that runs the LBNL website: Provides customized estimates of residential energy use and energy bills based on building description information provided by the user. Energy use is estimated using engineering models developed at LBNL. Space heating and cooling use is based on the DOE-2. 1E building simulation model. Other end-users (water heating, appliances, lighting, and misc. equipment) are based on engineering models developed by LBNL.

Mills, Evan↗

A Data-driven Control Method for Operating the Commercial HVAC Load as a Virtual Battery

Building loads have a great potential to provide ancillary services because of its large power consumption. In order to quantify their flexibility, methods of modeling building loads as virtual battery (VB) have been proposed. The VB model provides an effective way to coordinate building loads and energy storage systems together when providing service to grid. However, after grid send a power signal to VB, the control strategy has not been fully studied to let building consumes this desired amount of power yet. This paper introduces a method to control commercial heating, ventilation, and air conditioning (HVAC) system. First, the thermal model of commercial building is introduced. We then used several data-driven models to approximate this thermal dynamic and the operation of different HVAC components. Base on these data-driven models, we developed a centralized control algorithm to utilize HVAC system consuming the desired amount of power. Finally, we modeled a realistic commercial building in EnergyPlus to test the performance of this proposed control algorithm

Wang, Jiyu↗

Results From Development of Model Specifications for Multifamily Energy Retrofits

Specifications, modeled after CSI MasterFormat, provide the trade contractors and builders with requirements and recommendations on specific building materials, components and industry practices that comply with the expectations and intent of the requirements within the various funding programs associated with a project. The goal is to create a greater level of consistency in execution of energy efficiency retrofits measures across the multiple regions a developer may work. IBACOS and Mercy Housing developed sample model specifications based on a common building construction type that Mercy Housing encounters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards a Techno-Economic Analysis of PCM Integrated Hybrid HVAC Systems

Thermal end uses dominate building energy consumption and are a major driver of peak demand. As heating is electrified, peak electrical power required will surge, prompting a need for innovative HVAC system designs and controls.These designs must incorporate novel technologies at the component level and new integration techniques at the system level. One such possibility involves the addition of thermal energy storage (TES) in heating and cooling equipment using a phase change material (PCM) heat exchanger. Here, thermal energy storage via phase change can be used to shift the HVAC system loads to times of lower electricity cost, reduced carbon intensity, and greater energy efficiency. Most of the current utilization of PCM in buildings involves passive components. By actively controlling when heat is stored and released from PCM, we can optimize the building HVAC system to cost-effectively meet consumer needs with the flexibility to draw on renewable energy resources when they are abundant and available. While this combination of technologies is promising in theory, simulation-based evaluation of a prototype can be difficult due to the modeling requirements at the component level and the large number of possible configurations and operating modes at the system level. To conduct this evaluation, we use the Modelica language for modeling and simulation because it enables users to represent the important physics of the problem, interchange and rearrange components in an efficient manner, and implement a range of control configurations. In this work, we considered three case studies: a portable building, a large commercial retail store, and a multifamily residential apartment unit. Each of these employs a different system design, ranging from a single package vertical unit incorporating PCM to a central plant with independent heat pump, evaporative cooling, and thermal energy storage components. This paper describes the technologies in question, presents modeling at the component and system levels, and demonstrates building energy and demand charge cost savings with local time-of-use tariffs in a hot-dry climate.

Helmns, Dre↗

Incorporating machine learning with building network analysis to predict multi-building energy use

Predicting multi-building energy use at campus or city district scale has recently gained more attention; and more researchers have started to define reference buildings and study inter-impact between building groups. However, how to integrate the relationship to define reference buildings and predict multi-building energy use, using significantly less amount of building data and reducing complexity of prediction models, remains an open research question. To resolve this, this study proposed a novel method to predict multi-building energy use by integrating a social network analysis (SNA) with an Artificial Neural Network (ANN) technique. The SNA method was used to establish a building network (BN) by identifying reference buildings and determine correlations between reference buildings and non-reference buildings. The ANN technique was applied to learn correlations and historical building energy use, and then used to predict multi-building energy use. To validate the SNA-ANN method, 17 buildings in the Southeast University campus, located in Nanjing, China, were studied. These buildings have three years of actual monthly electricity use data and were grouped into four types: office, educational, laboratory, and residential. The results showed the integrated SNA-ANN method achieved average prediction accuracies of 90.67% for the office group, 90.79% for the educational group, 92.34% for the laboratory group, and 83.32% for the residential group. The results demonstrated the proposed SNA-ANN method achieved an accuracy of 90.28% for the predicted energy use for all building groups. Finally, this study provides insights into advancing the interdisciplinary research on multi-building energy use prediction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Multifamily Building Stock Modeling: Cooperative Research and Development Final Report, CRADA Number CRD-17-00701

U.S. multifamily buildings house 35 million households, consuming 4 quads of source energy and spending $48 billion on utility bills every year. Almost all of these households live in urban areas, where cities are taking the lead on setting aggressive energy goals. Cities currently do not have the data and tools necessary to identify and target opportunities to save energy in their building stock. Building on the open-source, OpenStudio-based ResStock platform, this project will extend the publicly-available ResStock modeling capabilities to the multifamily sector, enabling Radiant Labs, and others, to partner with cities to market and strategically deploy cost-effective, energy efficiency (EE) upgrades directly to high-priority households. Radiant Labs has been successful in using ResStock's single-family capabilities to provide value to the City of Boulder, Colorado. However, lack of multifamily capabilities in ResStock is a roadblock for Radiant Labs working with New York City, San Francisco, Washington, D.C., and other cities that have expressed significant interest in working with them. In addition, other cities, companies, and utilities can use these open-source capabilities to grow their EE portfolios, thereby multiplying the impact of this project. This work also enables national-scale analysis of EE potential in multifamily buildings, which is of strong interest to a variety of stakeholders, including the U.S. Department of Energy (DOE) Office of Energy Policy and Systems Analysis (EPSA), DOE Weatherization Assistance Program (WAP), U.S. Department of Housing and Urban Development (HUD), and the Bonneville Power Administration (BPA).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conservation of Dry Air, Water, and Energy in CAM and Its Potential Impact on Tropical Rainfall

Abstract For the Community Atmosphere Model version 6 (CAM6), an adjustment is needed to conserve dry air mass. This adjustment exposes an inconsistency in how CAM6’s energy budget incorporates water—in CAM6 water in the vapor phase has energy, but condensed phases of water do not. When water vapor condenses, only its latent energy is retained in the model, while its remaining internal, potential, and kinetic energy are lost. A global fixer is used in the default CAM6 model to maintain global energy conservation, but locally the energy tendency associated with water changing phase violates the divergence theorem. This error in energy tendency is intrinsically tied to the water vapor tendency, and reaches its highest values in regions of heavy rainfall, where the error can be as high as 40 W m −2 annually averaged. Several possible changes are outlined within this manuscript that would allow CAM6 to satisfy the divergence theorem locally. These fall into one of two categories: 1) modifying the surface flux to balance the local atmospheric energy tendency and 2) modifying the local atmospheric tendency to balance the surface plus top-of-atmosphere energy fluxes. To gauge which aspects of the simulated climate are most sensitive to this error, the simplest possible change—where condensed water still does not carry energy and a local energy fixer is used in place of the global one—is implemented within CAM6. Comparing this experiment with the default configuration of CAM6 reveals precipitation, particularly its variability, to be highly sensitive to the energy budget formulation. Significance Statement This study examines and explains spurious regional sources and sinks of energy in a widely used climate model. These energy errors result from not tracking energy associated with water after it transitions from the vapor phase to either liquid or ice. Instead, the model used a global fixer to offset the energy tendency related to the energy sources and sinks associated with condensed water species. We replace this global fixer with a local one to examine the model sensitivity to the regional energy error and find a large sensitivity in the simulated hydrologic cycle. This work suggests that the underlying thermodynamic assumptions in the model should be revisited to build confidence in the model-simulated regional-scale water and energy cycles.

Harrop, Bryce E.↗

Moving K-12 Zero Energy Schools to the Mainstream: Establishing Design Guidelines and Energy Targets: Preprint

K-12 school buildings are ideal candidates to lead the market shift from buildings that consume energy to buildings that produce as much renewable energy as they use, and there are now resources available to guide owners and project teams as they make that shift. Chief among them is the Advanced Energy Design Guide for K-12 School Buildings: Achieving Zero Energy (K-12 ZE AEDG). Starting with a feasibility study to prove that zero energy schools were possible, a committee of industry experts used extensive energy modeling to create a set of energy use intensity allowances for school buildings such that on-site renewable energy could meet the buildings' energy loads . These energy targets were compared with the energy use intensities of a limited number of schools that have achieved very high levels of energy performance. The allowances represent a 'zero energy ready' (rather than zero energy) school, because in many situations the ability to use on-site renewable sources is limited by utilities, policies, or economics. From these targets, the guidance for achieving a zero energy school was created and developed into the K-12 ZE AEDG, which covers the process of designing and building zero energy schools from the perspective of an owner and a project team. The K-12 ZE AEDG advocates setting an absolute energy target before design begins. The K-12 ZE AEDG also contains practical, cost-effective strategies for achieving the energy target and outreach approaches and disseminating these market-friendly strategies to design and school owner communities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moving K-12 Zero Energy Schools to the Mainstream: Establishing Design Guidelines and Energy Targets

K-12 school buildings are ideal candidates to lead the market shift from buildings that consume energy to buildings that produce as much renewable energy as they use, and there are now resources available to guide owners and project teams as they make that shift. Chief among them is the Advanced Energy Design Guide for K-12 School Buildings: Achieving Zero Energy (K-12 ZE AEDG). Starting with a feasibility study to prove that zero energy schools were possible, a committee of industry experts used extensive energy modeling to create a set of energy use intensity allowances for school buildings such that on-site renewable energy could meet the buildings' energy loads . These energy targets were compared with the energy use intensities of a limited number of schools that have achieved very high levels of energy performance. The allowances represent a 'zero energy ready' (rather than zero energy) school, because in many situations the ability to use on-site renewable sources is limited by utilities, policies, or economics. From these targets, the guidance for achieving a zero energy school was created and developed into the K-12 ZE AEDG, which covers the process of designing and building zero energy schools from the perspective of an owner and a project team. The K-12 ZE AEDG advocates setting an absolute energy target before design begins. The K-12 ZE AEDG also contains practical, cost-effective strategies for achieving the energy target and outreach approaches and disseminating these market-friendly strategies to design and school owner communities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Operation Model (Morpheus) for Dallas Fort Worth Airport (CRADA CRD-19-16301 Final Report)

The primary objective of this project was to leverage digital twin technology to enhance the design and operation of DFW Airport terminals and their associated energy systems. To achieve this, Morpheus, a building digital twin, was developed to guide improvements in airport operations, specifically targeting reductions in peak power demand and overall energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeled Retrofit Package Performance for Schools

This report details modeled energy performance and savings from retrofit packages in prototypical school buildings in climate zones throughout the U.S. The information herein serves as a reference for elementary and secondary schools interested in implementing retrofit packages in their facilities for energy savings as well as health and safety benefits. School models developed for simulating package performance differentiated between rural and urban environments. Simulations were run for 10 distinct climate zones covering a range of climate conditions throughout the U.S. Results include savings estimates for electricity, natural gas, CO 2 emissions, and annual utility costs for nine different retrofit packages that combine energy conservation measures, including HVAC controls and equipment upgrades, lighting efficiency upgrades, and electrification technologies such as heat pumps for space conditioning and domestic hot water. Nine additional retrofit packages were also developed for elementary schools and modeled in two climate zones. Appendix B describes the additional retrofit packages and presents savings estimates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗