On-Sun Evaluation of the PHLUX Method for Heliostat Beam Characterization.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Not provided.
Not provided.
The partial-wave inelasticity parameters of the amplitude for elastic pion-nucleon scattering are determined with the aid of the phenomenological amplitude for inelastic {pi}N {yields} {pi}{pi}N processes in the energy range extending to the threshold for the production of two pions. The resulting inelasticity parameters are compared with their counterparts derived from modern partial-wave analyses. The largest inelastic-scattering cross section in the P11 wave is in excellent agreement with the analogous value from the analysis performed at the George Washington University in 2006. For other waves, however, the present results differ in the majority of cases from respective values given by partial-wave analyses (the distinctions are especially large for the isospin-3/2 amplitudes).
In a transmission electron microscope, electrons are described by matter-waves with wavelengths five orders of magnitude smaller than optical electromagnetic waves. Analogous to optical holography, electron wavefronts can be shaped using nanoscale holographic gratings. Here we demonstrate a novel, scalable nanofabrication method for creating off-axis holographic gratings that demonstrate near ideal diffraction efficiencies for binary, sinusoidal, and blazed grating groove profiles. We show that this method can produce up to 50 µm diameter area gratings that diffract up to 68% of the transmitted electron wave into a desired diffraction order with less than 7% into any other order. Additionally, we find that the amount of inelastically scattered electrons from the material gratings remaining in the coherent diffraction orders from the gratings is negligible in the far field.
Explore the source record for details and available documents.
Not Available
Not Available
A data set used to normalize the detector response of the ARCS instrument see ARCS_256693.md in the data set for more details.
A data set used to normalize the detector response of the ARCS instrument see ARCS_58221.md in the data set for more details.
A data set used to normalize the detector response of the ARCS instrument. See ARCS_295641.md in the data set for more details.
A data set used to normalize the detector response of the ARCS instrument. See ARCS_336659.md in the data set for more details.
Accurately recording an electron bunch’s longitudinal profile is an important diagnostic for wakefield accelerators employing shaped bunches to increase transformer ratios. Electro-optic sampling of terahertz radiation from the bunch is an attractive approach due to its non-destructive nature. In preparation for future characterization experiments, the Argonne Wakefield Accelerator test facility has recently installed a 1550 nm laser system, including the necessary support systems to synchronize with the photoinjector laser system at 81.25 MHz. We report here on the initial installation and synchronization demonstrations.
As part of the task to improve and further automate the “AtR BPM Application” we provide the theoretically calculated R_transport_matrices.