Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bandwidth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Optic-microwave mixing velocimeter for superhigh velocity measurement

The phenomenon that a light beam reflected off a moving object experiences a Doppler shift in its frequency underlies practical interferometric techniques for remote velocity measurements, such as velocity interferometer system for any reflector (VISAR), displacement interferometer system for any reflector (DISAR), and photonic Doppler velocimetry (PDV). While VISAR velocimeters are often bewildered by the fringe loss upon high-acceleration dynamic process diagnosis, the optic-fiber velocimeters such as DISAR and PDV, on the other hand, are puzzled by high velocity measurement over 10 km/s, due to the demand for the high bandwidth digitizer. Here, we describe a new optic-microwave mixing velocimeter (OMV) for super-high velocity measurements. By using currently available commercial microwave products, we have constructed a simple, compact, and reliable OMV device, and have successfully obtained, with a digitizer of bandwidth 6 GH only, the precise velocity history of an aluminum flyer plate being accelerated up to 11.2 km/s in a three stage gas-gun experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of probe displacement to the thermal resolution limit in photonic force microscopy using a miniature quadrant photodetector

A photonic force microscope comprises of an optically trapped micro-probe and a position detection system to track the motion of the probe. Signal collection for motion detection is often carried out using the backscattered light off the probe-however, this mode has problems of low S/N due to the small backscattering cross sections of the micro-probes typically used. The position sensors often used in these cases are quadrant photodetectors. To ensure maximum sensitivity of such detectors, it would help if the detector size matched with the detection beam radius after the condenser lens (which for backscattered detection would be the trapping objective itself). To suit this condition, we have used a miniature displacement sensor whose dimensions makes it ideal to work with 1:1 images of micrometer-sized trapped probes in the backscattering detection mode. The detector is based on the quadrant photo-integrated chip in the optical pick-up head of a compact disc player. Using this detector, we measured absolute displacements of an optically trapped 1.1 {mu}m probe with a resolution of {approx}10 nm for a bandwidth of 10 Hz at 95% significance without any sample or laser stabilization. We characterized our optical trap for different sized probes by measuring the power spectrum for each probe to 1% accuracy, and found that for 1.1 {mu}m diameter probes, the noise in our position measurement matched the thermal resolution limit for averaging times up to 10 ms. We also achieved a linear response range of around 385 nm with cross talk between axes {approx_equal}4% for 1.1 {mu}m diameter probes. The detector has extremely high bandwidth (few MHz) and low optical power threshold-other factors that can lead to its widespread use in photonic force microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision linac and laser technologies for nuclear photonics gamma-ray sources

Tunable, high precision gamma-ray sources are under development to enable nuclear photonics, an emerging field of research. This paper focuses on the technological and theoretical challenges related to precision Compton scattering gamma-ray sources. In this scheme, incident laser photons are scattered and Doppler upshifted by a high brightness electron beam to generate tunable and highly collimated gamma-ray pulses. The electron and laser beam parameters can be optimized to achieve the spectral brightness and narrow bandwidth required by nuclear photonics applications. A description of the design of the next generation precision gamma-ray source currently under construction at Lawrence Livermore National Laboratory is presented, along with the underlying motivations. Within this context, high-gradient X-band technology, used in conjunction with fiber-based photocathode drive laser and diode pumped solid-state interaction laser technologies, will be shown to offer optimal performance for high gamma-ray spectral flux, narrow bandwidth applications.

43 PARTICLE ACCELERATORS↗

Ultra-wideband coaxial hybrid coupler for load resilient ion cyclotron range of frequency heating at fusion plasmas

We designed a high power and ultra-wideband two-section 3 dB coaxial hybrid coupler for load resilient ion cyclotron range of frequency heating by configuring asymmetric impedance matching using a three-dimensional simulation code, hfss. By adjusting the characteristic impedances of main and coupled lines of the hybrid coupler, we realized that the bandwidth of the proposed circuit is not only wider than that of a conventional three-section coupler, but also that the bandwidth is almost twice as wide compared to the conventional two-section hybrid coupler while maintaining the identical overall size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mach-Zehnder recording systems for pulsed power diagnostics

Fiber-optic transmission and recording systems, based on Mach-Zehnder modulators, have been developed and installed at the National Ignition Facility (NIF), and are being developed for other pulsed-power facilities such as the Z accelerator at Sandia, with different requirements. We present the design and performance characteristics for the mature analog links, based on the system developed for the Gamma Reaction History diagnostic at the OMEGA laser and at NIF. For a single detector channel, two Mach-Zehnders are used to provide high dynamic range at the full recording bandwidth with no gaps in the coverage. We present laboratory and shot data to estimate upper limits on the radiation effects as they impact recorded data quality. Finally, we will assess the technology readiness level for mature and developing implementations of Mach-Zehnder links for these environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear photofission studies with monochromatic {gamma} ray beams

Two new research facilities will be ready for operation very soon (MEGa-Ray at Liver-more National Laboratory) or start construction (ELI-Nuclear Physics in Bucharest), both providing highly brilliant {gamma} beams with so far unprecedented properties via Compton backscattering of laser photons from a high-quality, relativistic electron beam. With these intense, monochromatic {gamma} beams, a new era of photonuclear physics will be enabled. A new research campaign is proposed to exploit the unprecedented properties of these highly-brilliant, novel {gamma} beams on highly-selective studies of extremely deformed nuclei in the multiple-humped potential energy landscape of the actinides via photofission. With the unique {gamma} beam bandwidth of {Delta}E/E = 10{sup -3}, we can aim at resolving individual resonances which could never be achieved so far due to the limited {gamma} bandwidth of bremsstrahlung beams. Exploratory, non-bremsstrahlung photofission experiments are going to be performed very soon at the HI{gamma}S facility (Duke University, USA) to investigate the fine structure of the sub-barrier transmission resonances of the actinides.

43 PARTICLE ACCELERATORS↗

A single-shot, multiwavelength electro-optic data-acquisition system for inertial confinement fusion applications (invited)

Electro-optic data-acquisition systems encode the output from voltage-history diagnostics onto optical signals. The optical signals can propagate long distances over fiber-optic links without degrading the bandwidth of the encoded signal while protecting the recording electronics from overvoltage damage. The sinusoidal response and tolerance to high-input voltages of the Mach-Zehnder modulator used for the encoding leads to the additional advantage of a high dynamic range and a reduced need for manually swapping attenuators. We have demonstrated a single-shot, electro-optic data-acquisition system with a 600:1 dynamic range. This system provides optical isolation and a bandwidth of 6 GHz. The prototype system uses multiple optical wavelengths to allow for the multiplexing of up to eight signals onto one photodetector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Omnidirectional photonic band gap enlarged by one-dimensional ternary unmagnetized plasma photonic crystals based on a new Fibonacci quasiperiodic structure

In this paper, an omnidirectional photonic band gap realized by one-dimensional ternary unmagnetized plasma photonic crystals based on a new Fibonacci quasiperiodic structure, which is composed of homogeneous unmagnetized plasma and two kinds of isotropic dielectric, is theoretically studied by the transfer matrix method. It has been shown that such an omnidirectional photonic band gap originates from Bragg gap in contrast to zero-n gap or single negative (negative permittivity or negative permeability) gap, and it is insensitive to the incidence angle and the polarization of electromagnetic wave. From the numerical results, the frequency range and central frequency of omnidirectional photonic band gap can be tuned by the thickness and density of the plasma but cease to change with increasing Fibonacci order. The bandwidth of omnidirectional photonic band gap can be notably enlarged. Moreover, the plasma collision frequency has no effect on the bandwidth of omnidirectional photonic band gap. It is shown that such new structure Fibonacci quasiperiodic one-dimensional ternary plasma photonic crystals have a superior feature in the enhancement of frequency range of omnidirectional photonic band gap compared with the conventional ternary and conventional Fibonacci quasiperiodic ternary plasma photonic crystals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A tunable low-energy photon source for high-resolution angle-resolved photoemission spectroscopy

We describe a tunable low-energy photon source consisting of a laser-driven xenon plasma lamp coupled to a Czerny-Turner monochromator. The combined tunability, brightness, and narrow spectral bandwidth make this light source useful in laboratory-based high-resolution photoemission spectroscopy experiments. The source supplies photons with energies up to {approx}7 eV, delivering under typical conditions >10{sup 12} ph/s within a 10 meV spectral bandwidth, which is comparable to helium plasma lamps and many synchrotron beamlines. We first describe the lamp and monochromator system and then characterize its output, with attention to those parameters which are of interest for photoemission experiments. Finally, we present angle-resolved photoemission spectroscopy data using the light source and compare its performance to a conventional helium plasma lamp.

43 PARTICLE ACCELERATORS↗

Stability analysis of a two-stage tapered gyrotron traveling-wave tube amplifier with distributed losses

The two-stage tapered gyrotron traveling-wave tube (gyro-TWT) amplifier has achieved wide bandwidth in the millimeter wave range. However, possible oscillations in each stage limit this amplifier's operating beam current and thus its output power. To further enhance the amplifier's stability, distributed losses are applied to the interaction circuit of the two-stage tapered gyro-TWT. A self-consistent particle-tracing code is used for analyzing the beam-wave interactions. The stability analysis includes the effects of the wall losses and the length of each stage on the possible oscillations. Simulation results reveal that the distributed-loss method effectively stabilizes all the oscillations in the two stages. Under stable operating conditions, the device is predicted to produce a peak power of 60 kW with an efficiency of 29% and a saturated gain of 52 dB in the Ka-band. The 3-dB bandwidth is 5.7 GHz, which is approximately 16% of the center frequency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Compton gamma-ray sources at LLNL

Compact Compton scattering gamma-ray sources offer the potential of studying nuclear photonics with new tools. The optimization of such sources depends on the final application, but generally requires maximizing the spectral density (photons/eV) of the gamma-ray beam while simultaneously reducing the overall bandwidth on target to minimize noise. We have developed an advanced design for one such system, comprising the RF drive, photoinjector, accelerator, and electron-generating and electron-scattering laser systems. This system uses a 120 Hz, 250 pC, 2 ps, 0.35 mm mrad electron beam with 250 MeV maximum energy in an X-band accelerator scattering off a 150 mJ, 10 ps, 532 nm laser to generate 5 Multiplication-Sign 10{sup 10} photons/eV/s/Sr at 0.5 MeV with an overall bandwidth of less than 1%. The source will be able to produce photons up to energies of 2.5 MeV. We also discuss Compton scattering gamma-ray source predictions given by numerical codes.

43 PARTICLE ACCELERATORS↗

12 GeV detector technology at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) is presently in the middle of an upgrade to increase the energy of its CW electron beam from 6 GeV to 12 GeV along with the addition of a fourth experimental hall. Driven both by necessity and availability, novel detectors and electronics modules have been used in the upgrade. One such sensor is the Silicon Photomultiplier (SiPM), specifically a Multi-Pixel Photon Counter (MPPC), which is an array of avalanche photodiode pixels operating in Geiger mode that are used to sense photons. The SiPMs replace conventional photomultiplier tubes and have several distinct advantages including the safe operation in a magnetic field and the lack of need for high voltage. Another key to 12 GeV success is advanced fast electronics. Jlab will use custom 250 MHz and 125 MHz 12-bit analog to digital converters (ADCs) and time to digital converters (TDCs) all of which take advantage of VME Switched Serial (VXS) bus with its GB/s high bandwidth readout capability. These new technologies will be used to readout drift chambers, calorimeters, spectrometers and other particle detectors at Jlab once the 12 GeV upgrade is complete. The largest experiment at Jlab utilizing these components is GlueX - an experiment in the newly constructed Hall D that will study the photoproduction of light mesons in the search for hybrid mesons. The performance of these components and their respective detectors will be presented.

43 PARTICLE ACCELERATORS↗

Gain analysis of higher-order-mode amplification in a dielectric-implanted multi-beam traveling wave structure

A multi-beam traveling wave amplifier designed with an overmoded staggered double grating array was examined by small signal analysis combined with simulation. Eigenmode and S-parameter analyses show that the 2 cm long slow wave structure (SWS) has 1–5 dB insertion loss over the passband (TM{sub 31} mode) with ∼28% cold bandwidth. Analytic gain calculation indicates that in the SWS, TM{sub 31}-mode is amplified with 15–20 dB/beam at 64–84 GHz with three elliptical beams of 10 kV and 150 mA/beam, which was compared with particle-in-cell (PIC) simulations. PIC analysis on the analysis of instability with zero-input driving excitations demonstrated that background noises and non-operating lower order modes are noticeably suppressed by implanting equidistant dielectric absorbers; the overmoded structure only allowed the desired 3rd order mode to propagate in the structure. The designed circuit structure can be widely applied to multi-beam devices for high power RF generation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a Ka-band gyro-TWT amplifier for broadband operation

In this paper, the design of a Ka-band periodically ceramic loaded gyro-TWT amplifier has been carried out. The design predict that the interaction structure can produce more than 80 kW output power, 50 dB saturated gain, and 3 dB bandwidth for 65 kV and 5 A electron beam with velocity ratio (α) of 1.2. This paper describes the design and simulation of a high performance 35 GHz TE{sub 01} mode gyro-TWT that applies the same technique of employing a periodic dielectric loaded interaction structure to achieve stability and wide bandwidth. The design of input coupler with loaded interaction structure for Ka-band Gyro-TWT has been carried out using Ansoft hfss. The return loss (S{sub 11}) and transmission loss (S{sub 21}) of the Ka-band gyro-TWT input coupler have been found to be −27.3 dB and −0.05 dB, respectively. The design of output window for Ka-band Gyro-TWT has been carried out using cst microwave studio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diffracted X-ray tracking for monitoring intramolecular motion in individual protein molecules using broad band X-ray

Diffracted X-ray tracking (DXT) enables the tilting and twisting motions of single protein molecules to be monitored with micro- to milliradian resolution using a highly brilliant X-ray source with a wide energy bandwidth. We have developed a technique to monitor single molecules using gold nanocrystals attached to individual protein molecules using the BL28B2 beamline at SPring-8. In this paper we present the installation of a single toroidal X-ray mirror at BL28B2 to focus X-rays in an energy range of 10–20 keV (△E/E = 82% for an X-ray with a wide energy bandwidth). With this beamline we tracked diffraction spots from gold nanocrystals over a wide angle range than that using quasi-monochromatic X-rays. Application of the wide angle DXT technique to biological systems enabled us to observe the on-site motions of single protein molecules that have been functionalized in vivo. We further extend the capability of DXT by observing the fractional tilting and twisting motions of inner proteins under various conditions. As a proof of this methodology and to determine instrumental performance the intramolecular motions of a human serum albumin complex with 2-anthracenecarboxylic acid was investigated using the BL28B2 beamline. The random tilting and twisting intramolecular motions are shown to be directly linked to the movement of individual protein molecules in the buffer solution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a quantum-voltage-calibrated noise thermometer at NIM

A quantum-voltage-calibrated Johnson-noise thermometer was developed at NIM, which measures the Boltzmann constant k by comparing the thermal noise across a 100 Ω sense resistor at the temperature of the triple point of water with the pseudo-random frequency-comb voltage waveform synthesized with a bipolar-pulse-driven quantum-voltage-noise source. A measurement with integration period of 10 hours and bandwidth of 640 kHz resulted in a relative offset of 0.5×10{sup −6} from the current CODATA value of k, and a type A relative standard uncertainty of 23×10{sup −6}. Benefiting from closely matched noise powers and transmission-line impedances and small nonlinearities in the cross-correlation electronics, the derived k shows self-consistent values and standard uncertainties for different measurement bandwidths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A two-axis in-plane motion measurement system based on optical beam deflection

Measurement of in-plane motion with high resolution and large bandwidth enables model-identification and real-time control of motion-stages. This paper presents an optical beam deflection based system for measurement of in-plane motion of both macro- and micro-scale motion stages. A curved reflector is integrated with the motion stage to achieve sensitivity to in-plane translational motion along two axes. Under optimal settings, the measurement system is shown to theoretically achieve sub-angstrom measurement resolution over a bandwidth in excess of 1 kHz and negligible cross-sensitivity to linear motion. Subsequently, the proposed technique is experimentally demonstrated by measuring the in-plane motion of a piezo flexure stage and a scanning probe microcantilever. For the former case, reflective spherical balls of different radii are employed to measure the in-plane motion and the measured sensitivities are shown to agree with theoretical values, on average, to within 8.3%. For the latter case, a prototype polydimethylsiloxane micro-reflector is integrated with the microcantilever. The measured in-plane motion of the microcantilever probe is used to identify nonlinearities and the transient dynamics of the piezo-stage upon which the probe is mounted. These are subsequently compensated by means of feedback control.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of 140 gigahertz folded frame travelling wave tube

A study on the low voltage, high efficiency and wide bandwidth travelling wave tube by using a novel folded frame slow-wave structure is carried out in this paper. The radio frequency characteristics of the folded frame structure, including dispersion property, interaction impedances, and reflection property are investigated and compared to the similar symmetric double V-shape meander-line structure. Then, the beam-wave interaction process of the folded frame travelling wave tube (TWT) with rectangular sheet electron beam is simulated by 3-D particle-in-cell algorithms. The results show that the output power and electron efficiency can reach 259 W and 13.5% at the center frequency of 140 GHz, respectively. Simultaneously, the instantaneous 3-dB bandwidth is 24 GHz. Compared to the symmetric double V-shaped TWT, the output power and electron efficiency of the folded frame TWT are increased.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗