Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM SHAPING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Inclusive dielectron cross sections in p + p and p + d interactions at beam energies from 1.04 to 4.88 GeV

Measurements of dielectron production in p + p and p + d collisions with beamkinetic energies from 1.04 to 4.88 GeV are presented. The differential cross section is presented as a function of invariant pair mass, transverse momentum, and rapidity. The shapes of the mass spectra and their evolution with beam energy provide information about the relative importance of the various dielectron production mechanisms in this energy regime. The p + d to p + p ratio of the dielectron yield is also presented as a function of invariant pair mass, transverse momentum, and rapidity. The shapes of the transverse momentum and rapidity spectra from the p + d and p + p systems are found to be similar to one another for each of the beam energies studied. The beam energy dependence of the integrated cross sections is also presented.

NASA Discipline Radiation Health↗

Coherent Beam Combining of High Power Broad-Area Laser Diode Array with a Closed-V-shape External Talbot Cavity

We have coherently combined a high-power broad-area laser diode array by using a feedback loop closed off-axis external Talbot cavity. The off-axis feedback from two gratings provides transverse-mode control of broad-area lasers. The Talbot configuration of the external cavity implements diffractive coupling among laser diodes. Feedback from two gratings increases external cavity quality factor and spectrum selection capability. As a result, spatial coherence was improved and spectral linewidth was narrowed down. The high visibility of the far-field profile indicates that high spatial coherence was achieved. We also observed symmetric far-field profiles indicating that laser array was phase locked to in-phase and out-of-phase super-modes, respectively. Transition between these super-modes was observed by tuning one grating's tilted angle.

42 ENGINEERING↗

Matrix Analysis of Longitudinal and Torsional Vibrations in Nonuniform Multibranch Beams

Since longitudinal modes and frequencies provide basic data for dynamic analyses of arbitrary beam-like structures and since closed-form solutions for the modes are generally not feasible to obtain, an approximate method is developed for computing the natural frequencies and the corresponding mode shapes for a variable-section, unconstrained multibranch beam. A lumped mass analogy employing influence coefficients is used to represent the beam. The simultaneous equations of motion for the lumped mass system are derived in matrix form and algebraically manipulated to yield a classical eigenvalue equation solvable by standard procedures. The orthogonality relationship of the natural modes is derived and used to form the basis of an orthogonal sweeping process for determination of modes above the fundamental. Numerical examples including an application to a solid-fuel launch system are presented. Also, a detailed discussion is devoted to the theoretical verifications of the approximate modes and frequencies.

Wingate, Robert T.↗

An experimental-theoretical study of free vibrations of plates on elastic point supports

A theoretical and experimental study is made to investigate the effect on plate vibrations of varying the stiffness of corner elastic point supports. An experiment is conducted in which the bending stiffness of horizontal beams is used to support a square plate at its four corners. The stiffness of these supports can be varied over such a range that the plate fundamental frequency is lowered to 40% of the rigid support frequency. The variation with support stiffness of the frequencies of the first eight plate modes is measured and is compared with results from a theoretical model in which a Rayleigh-Ritz analysis is used which approximates the plate mode shapes as products of free-free beam modes. The elastic point supports are modeled both as massless translational springs and springs with tip masses, which are included to better represent the experimental supports.

Leuner, T. R.↗

Automatic tracking of arbitrarily shaped implanted markers in kilovoltage projection images: A feasibility study

Purpose: Certain types of commonly used fiducial markers take on irregular shapes upon implantation in soft tissue. This poses a challenge for methods that assume a predefined shape of markers when automatically tracking such markers in kilovoltage (kV) radiographs. The authors have developed a method of automatically tracking regularly and irregularly shaped markers using kV projection images and assessed its potential for detecting intrafractional target motion during rotational treatment. Methods: Template-based matching used a normalized cross-correlation with simplex minimization. Templates were created from computed tomography (CT) images for phantom studies and from end-expiration breath-hold planning CT for patient studies. The kV images were processed using a Sobel filter to enhance marker visibility. To correct for changes in intermarker relative positions between simulation and treatment that can introduce errors in automatic matching, marker offsets in three dimensions were manually determined from an approximately orthogonal pair of kV images. Two studies in anthropomorphic phantom were carried out, one using a gold cylindrical marker representing regular shape, another using a Visicoil marker representing irregular shape. Automatic matching of templates to cone beam CT (CBCT) projection images was performed to known marker positions in phantom. In patient data, automatic matching was compared to manual matching as an approximate ground truth. Positional discrepancy between automatic and manual matching of less than 2 mm was assumed as the criterion for successful tracking. Tracking success rates were examined in kV projection images from 22 CBCT scans of four pancreas, six gastroesophageal junction, and one lung cancer patients. Each patient had at least one irregularly shaped radiopaque marker implanted in or near the tumor. In addition, automatic tracking was tested in intrafraction kV images of three lung cancer patients with irregularly shaped markers during 11 volumetric modulated arc treatments. Purpose-built software developed at our institution was used to create marker templates and track the markers embedded in kV images. Results: Phantom studies showed mean ± standard deviation measurement uncertainty of automatic registration to be 0.14 ± 0.07 mm and 0.17 ± 0.08 mm for Visicoil and gold cylindrical markers, respectively. The mean success rate of automatic tracking with CBCT projections (11 frames per second, fps) of pancreas, gastroesophageal junction, and lung cancer patients was 100%, 99.1% (range 98%–100%), and 100%, respectively. With intrafraction images (approx. 0.2 fps) of lung cancer patients, the success rate was 98.2% (range 97%–100%), and 94.3% (range 93%–97%) using templates from 1.25 mm and 2.5 mm slice spacing CT scans, respectively. Correction of intermarker relative position was found to improve the success rate in two out of eight patients analyzed. Conclusions: The proposed method can track arbitrary marker shapes in kV images using templates generated from a breath-hold CT acquired at simulation. The studies indicate its feasibility for tracking tumor motion during rotational treatment. Investigation of the causes of misregistration suggests that its rate of incidence can be reduced with higher frequency of image acquisition, templates made from smaller CT slice spacing, and correction of changes in intermarker relative positions when they occur.

60 APPLIED LIFE SCIENCES↗

Mechanism of directional emission from a peanut-shaped microcavity

Collimated directional emission is essentially required for an asymmetric resonant cavity. In this paper, we theoretically investigate a type of peanut-shaped microcavity which can support highly directional emission with a beam divergence as small as 2.5 deg. The mechanism of the collimated emission of this type of peanut-shaped microcavity is explained with a short-term ray trajectory. Moreover, the explanations are also confirmed by a numerical wave simulation. This extremely narrow divergence of the emission holds great potential in highly collimated lasing from on-chip microcavities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of Feschenko BSM and Fast Faraday Cup with Low Energy Ion Beams

A comparison between Fast Faraday Cup and Feschenko longitudinal bunch shape detectors was recently performed at HELIAC Advanced Demonstrator beamline at GSI. Feschenko bunch shape monitor (BSM) uses the time to space conversion by means of secondary electrons emitted from a wire correlated to a rf deflector, while the fast Faraday cup (FFC) measures the deposited charge in a cup geometry matched to 50 Ohm. The FFC design aims to minimize the bunch shape dilution due to field polarization and secondary electrons produced on irradiation. An He¹⁺ with 100 µA average current and 1.4 MeV/u kinetic energy is utilized for this comparison. A buncher upstream of the detectors was operated to focus the beam longitudinally. The results are discussed in this contribution.

43 PARTICLE ACCELERATORS↗

Cavitation Damage Experiments for Mercury Spallation Targets At the LANSCE WNR in 2008

Proton beam experiments investigating cavitation damage in short pulse mercury spallation targets were performed at LANSCE WNR in July of 2008. They included two main areas for investigation: damage dependence on mercury velocity using geometry more prototypic to the SNS target than previously employed and damage dependence on incident proton beam flux intensity. The flow dependence experiment employed six test targets with mercury velocity in the channel ranging from 0 to more than 4 m/s. Each was hit with 100 WNR beam pulses with peak proton flux equivalent to that of SNS operating at 2.7 MW. Damage dependence on incident proton beam flux intensity was also investigated with three intensity levels used on simple rectangular shaped targets without mercury flow. Intensity variation was imposed by focusing the beam differently while maintaining protons per pulse. This kept total energy deposited in each target constant. A fourth test target was hit with various beams: constant protons and varied spot size; constant spot size and varied protons. No damage will be assessed in this case. Instead, acoustic emissions associated with cavitation collapse were measured by laser Doppler vibrometer (LDV) from readings of exterior vessel motions as well as by mercury wetted acoustic transducers. This paper will provide a description of the experiment and present available results. Damage assessment will require several months before surface analysis can be completed and was not available in time for IWSMT-9.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Self-focusing of a high current density ion beam extracted with concave electrodes in a low energy region around 150 eV

Spontaneous self-focusing of ion beam with high current density (J{sub c} ∼ 2 mA/cm{sup 2}, I{sub b} ∼ 65 mA) in low energy region (∼150 eV) is observed in a hydrogen ion beam extracted from an ordinary bucket type ion source with three electrodes having concave shape (acceleration, deceleration, and grounded electrodes). The focusing appears abruptly in the beam energy region over ∼135–150 eV, and the J{sub c} jumps up from 0.7 to 2 mA/cm{sup 2}. Simultaneously a strong electron flow also appears in the beam region. The electron flow has almost the same current density. Probably these electrons compensate the ion space charge and suppress the beam divergence.

43 PARTICLE ACCELERATORS↗

Modeling of transient interference phenomena in colinear laser spectroscopy

Colinear laser spectroscopy of fast atomic beams has been established as one of the main tools to perform precision experiments with atoms containing short-lived nuclei. Although highly sensitive, the spectral resolution of these techniques is typically limited to several MHz. Here, we study the use of transient interference phenomena to potentially improve the experimental resolution. Previous attempts to implement Ramsey-type measurements with fast beams were limited by the lack of understanding of the observed line shapes. Additionally, by using a simple model, we provide a satisfactory description of the previously observed line shapes and propose alternative experimental schemes to improve the resolution in fast ion-beam experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structural dynamic model obtained from flight use with piloted simulation and handling qualities analysis

The ability to use flight data to determine an aircraft model with structural dynamic effects suitable for piloted simulation. and handling qualities analysis has been developed. This technique was demonstrated using SR-71 flight test data. For the SR-71 aircraft, the most significant structural response is the longitudinal first-bending mode. This mode was modeled as a second-order system, and the other higher order modes were modeled as a time delay. The distribution of the modal response at various fuselage locations was developed using a uniform beam solution, which can be calibrated using flight data. This approach was compared to the mode shape obtained from the ground vibration test, and the general form of the uniform beam solution was found to be a good representation of the mode shape in the areas of interest. To calibrate the solution, pitch-rate and normal-acceleration instrumentation is required for at least two locations. With the resulting structural model incorporated into the simulation, a good representation of the flight characteristics was provided for handling qualities analysis and piloted simulation.

Powers, Bruce G.↗

Current Control in ITER Steady State Plasmas With Neutral Beam Steering

Predictions of quasi steady state DT plasmas in ITER are generated using the PTRANSP code. The plasma temperatures, densities, boundary shape, and total current (9 - 10 MA) anticipated for ITER steady state plasmas are specified. Current drive by negative ion neutral beam injection, lower-hybrid, and electron cyclotron resonance are calculated. Four modes of operation with different combinations of current drive are studied. For each mode, scans with the NNBI aimed at differing heights in the plasma are performed to study effects of current control on the q profile. The timeevolution of the currents and q are calculated to evaluate long duration transients. Quasi steady state, strongly reversed q profiles are predicted for some beam injection angles if the current drive and bootstrap currents are sufficiently large.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The challenges of beam polarization and keV-scale centre-of-mass energy calibration at the FCC-ee

The capability to determine the FCC-ee centre-of-mass energies (ECM) at the ppm level using resonant depolarization of the beams is essential for the Z line shape measurements, the W mass and the possible observation of the Higgs boson s-channel production. A first analysis (Blondel A et al Polarization and centre-of-mass energy calibration at FCC-ee. demonstrated the feasibility of this programme, conditional to careful preparation and a number of further developments. The existing simulation codes must be unified; the analysis and design of the instrumentation must be developed; and a detailed planning must be developed for the simultaneous and coordinated operation of the accelerator, of the continuous polarization and depolarization measurements, and of the beam monitoring devices, ensuring a precise extrapolation from beam energies to centre-of-mass energy and energy spread.

43 PARTICLE ACCELERATORS↗

On the Use of the Polynomial Annihilation Edge Detection for Locating Cracks in Beam-Like Structures

A crack in a structure causes a discontinuity in the first derivative of the mode shapes: On this basis, a numerical method for detecting discontinuities in smooth piecewise functions and their derivatives, based on a polynomial annihilation technique, has been applied to the problem of crack detection and localisation in beam-like structures for which only post-damage mode shapes are available. Using a finite-element model of a cracked beam, the performance of this methodology has been analysed for different crack depths and increasing amounts of noise. Given the crack position, a procedure to estimate its depth is also proposed and corresponding results shown.

Saxena, Rishu↗

A high flux source of swift oxygen atoms

A source of swift oxygen atoms is described which has several unique features. A high current ion beam is produced by a microwave discharge, accelerated to 10 keV and the mass selected by a modified Du Pont 21-110 mass spectrometer. The O(+) beam exciting the mass spectrometer is focused into a rectangular shape with an energy spread of less than 1 eV. The next section of the machine decelerates the ion beam into a counterpropagating electron beam in order to minimize space charge effects. After deceleration, the ion beam intersects at 90 deg, a neutral oxygen atom beam, which via resonant charge exchange produces a mixture of O(+) and O. Any remaining O(+) are swept out of the beam by an electric field and differentially pumped away while the desired O beam, collimated by slits, impinges on the target. In situ monitoring of the target surface is done by X-ray photoelectron or Auger spectroscopy. Faraday cups provide flux measurements in the ion sections while the neutral flux is determined by a special torsion balance or by a quadrupole mass spectrometer specially adapted for swift atoms. While the vacuum from the source through the mass spectrometer is maintained by diffusion pumps, the rest of the machine is UHV.

Fink, M.↗

R-Matrix Analysis of the 236 U(n,gamma) Reaction in theResolved Resonance Energy Region

The neutron capture cross section of 236U was measured in the neutron energy range from 1 eV to 10 keV by the neutron time-of-flight method at the GELINA white pulsed neutron source of the Institute for Reference Materials and Measurements (IRMM) in Geel (Belgium). The gamma rays originating from neutron capture events were detected by two C6D6-based liquid scintillators using the pulse height weighting technique. The weighting function has been derived from Monte-Carlo simulations of the detector response to monoenergetic gamma rays. The sample under investigation with a total amount of 338 mg of 236U was located in the neutron beam at a distance of 28.6 m from the source. The shape of the neutron flux was determined by a 10B neutron counter, placed approximately 60 cm upstream in the neutron beam line. The neutron capture yield in the resolved resonance region up to 1 keV has been derived from time-of-flight spectra.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Changes of optical properties of retroreflector installed in LHD

This article describes changes of optical properties of retroreflectors installed on the inner wall of the vacuum vessel of the Large Helical Device. They were made of stainless steel and were used for a CO{sub 2} laser polarimeter. The reflectivity for a CO{sub 2} laser beam dropped up to 40% after the start of glow discharge cleanings and main plasma experiments. Then it decreased gradually. The reflectivity in a wavelength range shorter than 10 {mu}m decreased significantly through one experimental campaign (about 4 months). On the other hand the reflectivity in a wavelength range longer than 50 {mu}m was larger than 70%. Decrease in the reflectivity in the central region of mirrors was more significant (the reflectivity for visible beams became almost zero) than that in the edge. The distribution of the reflectivity along the radial direction is expected to be related to the shape of the retroreflector. The parallelism of the reflected beam to an incident one also deteriorated. The changes in the polarization angle and in the ellipticity of reflected light polarization were not observed from the visible to the far infrared range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Machine learning control of an elliptically bent hard x-ray mirror

This article showcases the high-resolution control of an elliptically bent hard X-ray mirror optics at the Advanced Photon Source. The mirror uses a compact laminar flexure bending mechanism to achieve elliptical shapes covering a large range of focal distances. An array of capacitive sensors are used as a surface profiler for in-situ monitoring of the mirror shape. Machine learning and control techniques were used to change the mirror shape and focus the incident X-ray at predefined focal planes. The mirror surface shape error can be controlled to be within 40 nm rms with high repeatability. This technique gives the capability to focus incident X-ray beam within a range of focal distances corresponding to shape deformation range of a mirror optics. This work would be beneficial for controlling similar adaptive optics for multiple adaptive optics systems.

adaptive optics↗