Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Automating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Study of space shuttle orbiter system management computer function. Volume 2: Automated performance verification concepts

The findings are presented of investigations on concepts and techniques in automated performance verification. The investigations were conducted to provide additional insight into the design methodology and to develop a consolidated technology base from which to analyze performance verification design approaches. Other topics discussed include data smoothing, function selection, flow diagrams, data storage, and shuttle hydraulic systems.

Source record↗

Automated space processing payloads study. Volume 2, book 2: Technical report, appendices A through E

Experiment hardware and operational requirements for space shuttle experiments are discussed along with payload and system concepts. Appendixes are included in which experiment data sheets, chamber environmental control and monitoring, method for collection and storage of electrophoretically-separated samples, preliminary thermal evaluation of electromagnetic levitation facilities L1, L2, and L3, and applicable industrial automation equipment are discussed.

Source record↗

Airborne electronics for automated flight systems

The increasing importance of airborne electronics for use in automated flight systems is briefly reviewed with attention to both basic aircraft control functions and flight management systems for operational use. The requirements for high levels of systems reliability are recognized. Design techniques are discussed and the areas of control systems, computing and communications are considered in terms of key technical problems and trends for their solution.

Graves, G. B., Jr.↗

Automated Mars surface sample return mission concepts for achievement of essential scientific objectives

Mission concepts were investigated for automated return to Earth of a Mars surface sample adequate for detailed analyses in scientific laboratories. The minimum sample mass sufficient to meet scientific requirements was determined. Types of materials and supporting measurements for essential analyses are reported. A baseline trajectory profile was selected for its low energy requirements and relatively simple implementation, and trajectory profile design data were developed for 1979 and 1981 launch opportunities. Efficient spacecraft systems were conceived by utilizing existing technology where possible. Systems concepts emphasized the 1979 launch opportunity, and the applicability of results to other opportunities was assessed. It was shown that the baseline missions (return through Mars parking orbit) and some comparison missions (return after sample transfer in Mars orbit) can be accomplished by using a single Titan III E/Centaur as the launch vehicle. All missions investigated can be accomplished by use of Space Shuttle/Centaur vehicles.

Weaver, W. L.↗

The automated multi-stage substructuring system for NASTRAN

The substructuring capability developed for eventual installation in Level 16 is now operational in a test version of NASTRAN. Its features are summarized. These include the user-oriented, Case Control type control language, the automated multi-stage matrix processing, the independent direct access data storage facilities, and the static and normal modes solution capabilities. A complete problem analysis sequence is presented with card-by-card description of the user input.

Field, E. I.↗

Automated Iodine Monitoring System Development (AIMS)

The operating principle of the automated iodine monitoring/controller system (AIMS) is described along with several design modifications. The iodine addition system is also discussed along with test setups and calibration; a facsimile of the optical/mechanical portion of the iodine monitor was fabricated and tested. The appendices include information on shuttle prototype AIMS, preliminary prime item development specifications, preliminary failure modes and effects analysis, and preliminary operating and maintenance instructions.

Source record↗

Automated structural design with aeroelastic constraints - A review and assessment of the state of the art

A review and assessment of the state of the art in automated aeroelastic design is presented. Most of the aeroelastic design studies appearing in the literature deal with flutter, and, therefore, this paper also concentrates on flutter. The flutter design problem is divided into three cases: as isolated flutter mode, neighboring flutter modes, and a hump mode which can rise and cause a sudden, discontinuous change in the flutter velocity. Synthesis procedures are presented in terms of techniques that are appropriate for problems of various levels of difficulty. Current trends, which should result in more efficient, powerful and versatile design codes, are discussed. Approximate analysis procedures and the need for simultaneous consideration of multiple design requirements are emphasized.

Stroud, W. J.↗

An automated and repeatable data analysis procedure for remote sensing applications

A new multispectral data analysis procedure, based on LARSYS, has been developed which substantially reduces the influence of the analyst. The analysis is automated, including the interpretation of clustering results. The classification results obtained are repeatable and not biased by analyst subjectivity during the analysis.

Davis, B. J.↗

A fully automated digitally controlled 30-inch telescope

A fully automated 30-inch (75-cm) telescope has been successfully designed and constructed from a military surplus Nike-Ajax radar mount. Novel features include: closed-loop operation between mountain telescope and campus computer 30 km apart via microwave link, a TV-type sensor which is photon shot-noise limited, a special lightweight primary mirror, and a stepping motor drive capable of slewing and settling one degree in one second or a radian in fifteen seconds.

Colgate, S. A.↗

Automated solvent concentrator

Designed for automated drug identification system (AUDRI), device increases concentration by 100. Sample is first filtered, removing particulate contaminants and reducing water content of sample. Sample is extracted from filtered residue by specific solvent. Concentrator provides input material to analysis subsystem.

Griffith, J. S.↗

Automated EEG acquisition

Automated self-contained portable device can be used by technicians with minimal training. Data acquired from patient at remote site are transmitted to centralized interpretation center using conventional telephone equipment. There, diagnostic information is analyzed, and results are relayed back to remote site.

Frost, J. D., Jr.↗

Microcontroller for automation application

A microcontroller for automation application is currently being developed. It is basically an 8-bit microcomputer with a 40K byte random access memory/read only memory, and can control a maximum of 12 devices through standard 15-line interface ports.

H. W. Cooper↗

Automated finite element grid break-up method, a verification of the six node averaging approach

The verification of the nodal averaging method for generating automated finite triangular element grids was demonstrated. This was accomplished with a six node averaging program (SNAP) which was placed on an IBM 2250 vector graphics scope terminal. The advantage of this method is that it is unnecessary to program time consuming geometric division and transition algorithms.

Barten, H. J.↗

Advanced prototype automated iodine monitor system

The technique of detecting and measuring parts-per-million concentrations of aqueous iodine by direct spectrophotometric means is discussed, and development of a prototype Automated Iodine Monitoring/Controller System (AIMS) is elaborated. The present effort is directed primarily toward reducing the power requirement and the weight of the AIMS. Other objectives include determining the maximum concentration of iodine that can be dissolved in an alcohol solution, and in an aqueous potassium iodide solution. Also discussed are the effects of a no flow condition on iodine measurements and the effect of pH on spectrophotometric iodine determinations.

Source record↗

Application of remotely sensed multispectral data to automated analysis of marshland vegetation. Inference to the location of breeding habitats of the salt marsh mosquito (Aedes Sollicitans)

The techniques used for the automated classification of marshland vegetation and for the color-coded display of remotely acquired data to facilitate the control of mosquito breeding are presented. A multispectral scanner system and its mode of operation are described, and the computer processing techniques are discussed. The procedures for the selection of calibration sites are explained. Three methods for displaying color-coded classification data are presented.

Cibula, W. G.↗

Computer automation for feedback system design

Mathematical techniques and explanations of various steps used by an automated computer program to design feedback systems are summarized. Special attention was given to refining the automatic evaluation suboptimal loop transmission and the translation of time to frequency domain specifications.

Source record↗

The NASA-NMSU automated meteor observatory

A new observatory for meteor research which provides data for study of meteor heights, velocities, orbits, and meteoroid abundances is described. The observing equipment is automated to take advantage of the long periods of favorable observing weather common to the region. Four K-24 cameras, electrically operated, provide the triangulation observations, and four Maksutov f/1.3 cameras with blazed transmission grating provide spectral coverage. The patrol cameras have operated for a year and a half, and approximately 6,000 frames have been exposed by 9 March 1975. Meteor trails appear on 260 of these frames. Sixty-eight trails are of meteors photographed from two locations and thus allow trajectory and orbit determinations for 34 meteors. Photoelectric sensors initiate the 2-second spectrograph exposures, and electrical controls open and close the observatory at present times.

Harvey, G. A.↗