Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

The MESUR Mission

The MESUR mission will place a network of small, robust landers on the Martian surface, making a coordinated set of observations for at least one Martian year. MESUR presents some major challenges for development of instruments, instrument deployment systems, and on board data processing techniques. The instrument payload has not yet been selected, but the straw man payload is (1) a three-axis seismometer; (2) a meteorology package that senses pressure, temperature, wind speed and direction, humidity, and sky brightness; (3) an alphaproton-X-ray spectrometer (APXS); (4) a thermal analysis/evolved gas analysis (TA/EGA) instrument; (5) a descent imager, (6) a panoramic surface imager; (7) an atmospheric structure instrument (ASI) that senses pressure, temperature, and acceleration during descent to the surface; and (8) radio science. Because of the large number of landers to be sent (about 16), all these instruments must be very lightweight. All but the descent imager and the ASI must survive landing loads that may approach 100 g. The meteorology package, seismometer, and surface imager must be able to survive on the surface for at least one Martian year. The seismometer requires deployment off the lander body. The panoramic imager and some components of the meteorology package require deployment above the lander body. The APXS must be placed directly against one or more rocks near the lander, prompting consideration of a micro rover for deployment of this instrument. The TA/EGA requires a system to acquire, contain, and heat a soil sample. Both the imagers and, especially, the seismometer will be capable of producing large volumes of data, and will require use of sophisticated data compression techniques.

Squyres, S. W.↗

Analysis of a Destructive Wind Storm on 16 November 2008 in Brisbane, Australia

During the late afternoon on 16 November 2008 the Brisbane (Australia) suburb of “The Gap” experienced extensive wind damage caused by an intense local thunderstorm. The CP2 research radar nearby detected near-surface radial velocities exceeding 44 m s -1 above The Gap while hail size reports did not exceed golf ball size, and no tornadoes were reported. This study shows that the storm environment was characterized by a layer of very moist (mixing ratios exceeding 12 g kg -1 ) near-surface air embedded in strong storm-relative low-level flow, whereas the storm-relative winds aloft were significantly weaker. And while the thermodynamic storm environment contained a range of downdraft promoting ingredients such as a ~4 km high melting level above a ~2 km deep layer with nearly dry adiabatic lapse rates mostly collocated with dry ambient air, a ~1 km deep stable layer near the ground would generally lower expectations of destructive surface winds based on the downburst mechanism. We also found that once observed reflectivities exceed 70 dBZ that downdraft cooling due to hail melting and downdraft acceleration based on hail loading are likely to become non-negligible forcing mechanisms for a strong downdraft. The study found a close proximity of the hydrostatically and dynamically driven mesohigh at the base of the downdraft to a dynamically driven mesolow associated with a radar-observed low-level circulation. This proximity is hypothesized to have been instrumental in the observed anisotropic horizontal acceleration of the near-ground outflow and the ultimate strength of the Gap storm surface winds. Finally, we speculate that the 44 weak storm-relative midlevel winds allowed the downdraft to descend close to the low45 level circulation which set up this strong horizontal perturbation pressure gradient.

54 ENVIRONMENTAL SCIENCES↗

Demonstration of low-level biogenic fuel content using quench curve and direct liquid scintillation counting (LSC) methods

In this work, an investigation into the direct method for liquid scintillation counting (LSC) quantification of biogenic fuel content in fuel blendstock is presented. This method development intentionally used a colored matrix (~99 wt%), fossil diesel fraction, and low-level biogenic fractions (~1 wt%) to determine the applicability of the LSC technique in colored blend mixtures. LSC procedures for quench correction, including the use of an instrument internal standard (Quantulus SQP values), color quench curves, and an internal 14 C standard spike on samples containing low-level amounts of biogenic gasoline, jet, and diesel mixed with fossil fuel, were compared. Samples were analyzed on both Perkin-Elmer Quantulus and Tri-Carb instruments, and the 14 C contents were compared with those determined by accelerator mass spectrometry (AMS). Results from the Tri-Carb instrument showed that percent differences of <10 % compared to AMS-reported values are achievable at 5-hour count times despite colored samples. A comparison between the impact of chemical and color quenching in the fuel samples showed that color quenching in highly colored samples reduces efficiency significantly more than chemical quenching, indicating that chemical quench curves are not appropriate for highly colored biofuel/fossil-fuel blended samples. Results indicate that both the direct method with internal spike quench correction and the use of a color-quench curve provide accurate results for 1 % biogenic fuel blends. Additionally, we have explored the use of Fourier transform infrared (FTIR) spectroscopy in measuring the biogenic content of the colored blended fuel samples. Preliminary results show the presence of biogenic carbon-derived fingerprints that are absent in fossil-derived sample. However, further work is needed to develop an FTIR-based quantitative method.

09 BIOMASS FUELS↗

Assessment of Vibration and Shock Loading Environments on Steels Used in Railroad Applications Considering Hydrogen Embrittlement

Studies that examine the combined effects of hydrogen and rail loading environments in the context of hydrogen embrittlement of steels have not been performed. Large-scale hydrogen storage requires either gaseous hydrogen stored in pressure vessels and tubing or liquid hydrogen in cryogenic, insulated tanks. Since the focus of this study is on steels, we examine the influence of hydrogen on stainless steel used for high pressure tubing and cryogenic tanks and Cr-Mo steel liners used in gaseous pressure vessels. Literature studies show that despite hydrogen degradation, these steels can be used effectively and safely if the stresses are managed. The shock and vibration environment on railcars present unique environments where stresses and loading rates can be high. A literature review was conducted to understand the accelerations experienced in rail by examining instrumented railcars of nuclear fuel casks. Hydrogen studies were examined that focused on steel pressure hardware with an emphasis on fatigue, fast loading rates, and low temperatures. A simplified fatigue assessment was performed to examine design cycles for three different hydrogen components: stainless steel tubing, stainless steel cryogenic tanks, and gaseous pressure vessels. The assessments were idealized and used bounding cases of accelerations in both normal rail conditions and coupling events. In normal shock and vibration environments when accelerations were less than 2 g, infinite design life was calculated. In extreme shock or coupling environments, finite design life was calculated which was shown to be dependent on unsupported lengths of pressure components. It was shown that adjusting the unsupported length can reduce the bending stress thereby increasing design life.

36 MATERIALS SCIENCE↗

Investigation of advanced propulsion technologies: The RAM accelerator and the flowing gas radiation heater

The two principal areas of advanced propulsion investigated are the ram accelerator and the flowing gas radiation heater. The concept of the ram accelerator is presented as a hypervelocity launcher for large-scale aeroballistic range applications in hypersonics and aerothermodynamics research. The ram accelerator is an in-bore ramjet device in which a projectile shaped like the centerbody of a supersonic ramjet is propelled in a stationary tube filled with a tailored combustible gas mixture. Combustion on and behind the projectile generates thrust which accelerates it to very high velocities. The acceleration can be tailored for the 'soft launch' of instrumented models. The distinctive reacting flow phenomena that have been observed in the ram accelerator are relevant to the aerothermodynamic processes in airbreathing hypersonic propulsion systems and are useful for validating sophisticated CFD codes. The recently demonstrated scalability of the device and the ability to control the rate of acceleration offer unique opportunities for the use of the ram accelerator as a large-scale hypersonic ground test facility. The flowing gas radiation receiver is a novel concept for using solar energy to heat a working fluid for space power or propulsion. Focused solar radiation is absorbed directly in a working gas, rather than by heat transfer through a solid surface. Previous theoretical analysis had demonstrated that radiation trapping reduces energy loss compared to that of blackbody receivers, and enables higher efficiencies and higher peak temperatures. An experiment was carried out to measure the temperature profile of an infrared-active gas and demonstrate the effect of radiation trapping. The success of this effort validates analytical models of heat transfer in this receiver, and confirms the potential of this approach for achieving high efficiency space power and propulsion.

Bruckner, A. P.↗

Changes in mesenteric, renal, and aortic flows with +Gx acceleration

Previous studies in man and dogs have indicated that the splanchnic bed might contribute to the maintenance of arterial pressure during +Gx acceleration. Eight mongrel dogs were chronically instrumented with Doppler flow probes around the superior mesenteric (SMA) and renal arteries (RA) as well as the terminal aorta (TA). A solid-state pressure transducer was placed in the aorta distal to the flow probe. Using alpha-chloralose anesthesia following a 2-4 week recovery period, the animals were subjected to 120 sec at levels of 5, 10 and 15 +Gx acceleration on a 7.6-m radius centrifuge. The results indicate that both an active component and a mechanical component contribute to the maintenance of arterial pressure during +Gx acceleration.

Stone, H. L.↗

Time-Dependent Behavior of High-Strength Kevlar and Vectran Webbing

High-strength Kevlar and Vectran webbings are currently being used by both NASA and industry as the primary load-bearing structure in inflatable space habitation modules. The time-dependent behavior of high-strength webbing architectures is a vital area of research that is providing critical material data to guide a more robust design process for this class of structures. This paper details the results of a series of time-dependent tests on 1-inch wide webbing including an initial set of comparative tests between specimens that underwent realtime and accelerated creep at 65 and 70% of their ultimate tensile strength. Variability in the ultimate tensile strength of the webbings is investigated and compared with variability in the creep life response. Additional testing studied the effects of load and displacement rate, specimen length and the time-dependent effects of preconditioning the webbings. The creep test facilities, instrumentation and test procedures are also detailed. The accelerated creep tests display consistently longer times to failure than their real-time counterparts; however, several factors were identified that may contribute to the observed disparity. Test setup and instrumentation, grip type, loading scheme, thermal environment and accelerated test postprocessing along with material variability are among these factors. Their effects are discussed and future work is detailed for the exploration and elimination of some of these factors in order to achieve a higher fidelity comparison.

Jones, Thomas C.↗

The Gamma-ray Large Area Space Telescope and Gamma-Ray Bursts

The Gamma-ray Large Area Telescope (GLAST) is a satellite-based observatory to study the high energy gamma-ray sky. The main instrument on GLAST, the Large Area Telescope (LAT) is a pair-conversion telescope that will survey the sky from 20 MeV to greater than 300 GeV. With the GLAST launch in 2007, the LAT will open a new and important window on a wide variety of high energy phenomena, including supermassive black holes and active galactic nuclei, gamma-ray bursts, supernova remnants and cosmic ray acceleration and dark matter. A second instrument, the GLAST Burst Monitor (GBM), greatly enhances GLAST s capability to study GRB by providing important spectral and timing information in the 10 keV to 30 MeV range. We describe how the instruments, spacecraft and ground system work together to provide observations of gamma-ray bursts from 8 keV - 300 GeV and to provide rapid notification of bursts to the wider gamma-ray burst community.

McEnery, Julie↗

Beam Instrumentation at the Fermilab IOTA Ring

The Integrable Optics Test Accelerator (IOTA) is a storage ring located at the end of the Fermilab Accelerator Science and Technology (FAST) facility. The complex is intended to support accelerator R&D for the next generation of particle accelerators. The IOTA ring is currently operating with 100 MeV electrons injected from the FAST Linac and will also receive 2.5 MeV protons from the IOTA Proton Injector currently being installed. The current instrumentation and results from the first electron commissioning run will be presented along with future plans.

43 PARTICLE ACCELERATORS↗

Synchrotron radiation based beam diagnostics at the Fermilab Tevatron

Synchrotron radiation has been used for many years as a beam diagnostic at electron accelerators. It is not normally associated with proton accelerators as the intensity of the radiation is too weak to make detection practical. Therefore, if one utilizes the radiation originating near the edge of a bending magnet, or from a short magnet, the rapidly changing magnetic field serves to enhance the wavelengths shorter than the cutoff wavelength, which for more recent high energy proton accelerators such as Fermilab's Tevatron, tends to be visible light. This paper discusses the implementation at the Tevatron of two devices. A transverse beam profile monitor images the synchrotron radiation coming from the proton and antiproton beams separately and provides profile data for each bunch. A second monitor measures the low-level intensity of beam in the abort gaps which poses a danger to both the accelerator's superconducting magnets and the silicon detectors of the high energy physics experiments. Comparisons of measurements from the profile monitor to measurements from the flying wire profile systems are presented as are a number of examples of the application of the profile and abort gap intensity measurements to the modelling of Tevatron beam dynamics.

43 PARTICLE ACCELERATORS↗

RECENT BEAM MEASUREMENTS AND NEW INSTRUMENTATION AT THE ADVANCED LIGHT SOURCE

The Advanced Light Source (ALS) in Berkeley was the first of the soft x-ray third generation light source ever built, and since 1993 has been in continuous and successful operation serving a large community of users in the VUV and soft x-ray community. During these years the storage ring underwent through several important upgrades that allowed maintaining the performance of this veteran facility at the forefront. The ALS beam diagnostics and instrumentation have followed a similar path of innovation and upgrade and nowadays include most of the modem and last generation devices and technologies that are commercially available and used in the recently constructed third generation light sources. In this paper we will not focus on such already widely known systems, but we will concentrate our effort in the description of some measurements techniques, instrumentation and diagnostic systems specifically developed at the ALS and used during the last few years.

43 PARTICLE ACCELERATORS↗

Quick extended x-ray absorption fine structure instrument with millisecond time scale, optimized for in situ applications

In order to learn about in situ structural changes in materials at subseconds time scale, we have further refined the techniques of quick extended x-ray absorption fine structure (QEXAFS) and quick x-ray absorption near edge structure (XANES) spectroscopies at beamline X18B at the National Synchrotron Light Source. The channel cut Si (111) monochromator oscillation is driven through a tangential arm at 5 Hz, using a cam, dc motor, pulley, and belt system. The rubber belt between the motor and the cam damps the mechanical noise. EXAFS scan taken in 100 ms is comparable to standard data. The angle and the angular range of the monochromator can be changed to collect a full EXAFS or XANES spectrum in the energy range 4.7-40.0 KeV. The data are recorded in ascending and descending order of energy, on the fly, without any loss of beam time. The QEXAFS mechanical system is outside the vacuum system, and therefore changing the mode of operation from conventional to QEXAFS takes only a few minutes. This instrument allows the acquisition of time resolved data in a variety of systems relevant to electrochemical, photochemical, catalytic, materials, and environmental sciences.

43 PARTICLE ACCELERATORS↗

Instrument Bearing Life with Non-CFC Cleaners

Accelerated bearing life tests were conducted to evaluate the effects of ODC-free bearing cleaning solvents as a replacement to CFC-113. Three chemically different, ODC-free cleaning solvents were tested against the CFC-113 baseline. Test bearings were representative of the type that would be used for a space scanner bearing application. The bearings were lubricated with two space flight oils. Lives with the replacement solvents exceeded those obtained with CFC-113 baseline. Pennzane-lubricated bearings enjoy a 2 to 6X life advantage over those lubricated with Bray 815Z oil.

Loewenthal, Stuart↗

Beam Instrumentation of the PXIE LEBT Beamline

The PXIE accelerator [1] is the front-end test stand of the proposed Proton Improvement Plan (PIP-II) [2] initiative: a CW-compatible pulsed H- superconducting RF linac upgrade to Fermilab’s injection system. The PXIE Ion Source and Low-Energy Beam Transport (LEBT) section are designed to create and transfer a 1-10 mA $H^{-}$ beam, in either pulsed (0.001–16 ms) or DC mode, from the ion source through to the injection point of the RFQ. This paper discusses the range of diagnostic tools – Allison-type Emittance Scanner, Faraday Cup, Toroid, DCCT, electrically isolated diaphragms – involved in the commissioning of the beam line and preparation of the beam for injection into the RFQ.

D'Arcy, R.↗

Simple Tools for Characterization of Synchrotron Beam Flux, Energy Resolution and Stability

Flux is a simple yet key indicator of overall beamline alignment. For many synchrotron measurements, the energy resolution and reproducibility are important characteristics as well. However, many beamlines do not have diffractometers capable of measuring the energy resolution in the experimental hutches. For absolute flux measurements, we have found that thickness calibrated Si photodiodes make very convenient, robust detectors capable of handling a wide flux range. For measuring the energy resolution, we have developed a simple, portable instrument analyzer applicable to any beamline with a scanning monochromator. This same instrument is capable of measuring the energy stability and reproducibility as well. We have used these to characterize many of the beamlines on the NSLS X-ray ring, and will present the methods and our experience to date to demonstrate their usefulness.

43 PARTICLE ACCELERATORS↗

First results and planned experiments with the INFN-LNS ray-tracing magnetic spectrometer MAGNEX

The MAGNEX large-acceptance ray-tracing magnetic spectrometer has recently been used with beams from the INFN-LNS Tandem accelerator. After an accurate commissioning, the instrument has started an ambitious experimental program. In the first experiment the {sup 19}F({sup 7}Li,{sup 7}Be){sup 19}O charge-exchange reaction was studied at 52 MeV incident energy. The {sup 19}O excitation energy spectrum was reconstructed and the angular distributions measured. The second experiment was aimed at the study of the {sup 15}C via the {sup 13}C({sup 18}O,{sup 16}O){sup 15}C reaction at 84 MeV incident energy. The ejectiles where detected at forward angles and mass identified by means of an innovative technique. The {sup 15}C excitation energy spectra up to about 20 MeV were obtained with a 250 keV FWHM energy resolution. In addition to several known states, the spectra show two unknown resonant-like structures at 11.4 and 14.0 MeV. The strong population of these structures, together with the measured widths, could indicate the collective nature of these states associated to a correlated neutron pair transfer. Besides the first results of physical interest from these two experiments, future experiments with MAGNEX are briefly outlined.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IMPULSIVE ACCELERATION OF CORONAL MASS EJECTIONS. II. RELATION TO SOFT X-RAY FLARES AND FILAMENT ERUPTIONS

Using high time cadence images from the STEREO EUVI, COR1, and COR2 instruments, we derived detailed kinematics of the main acceleration stage for a sample of 95 coronal mass ejections (CMEs) in comparison with associated flares and filament eruptions. We found that CMEs associated with flares reveal on average significantly higher peak accelerations and lower acceleration phase durations, initiation heights, and heights, at which they reach their peak velocities and peak accelerations. This means that CMEs that are associated with flares are characterized by higher and more impulsive accelerations and originate from lower in the corona where the magnetic field is stronger. For CMEs that are associated with filament eruptions we found only for the CME peak acceleration significantly lower values than for events that were not associated with filament eruptions. The flare rise time was found to be positively correlated with the CME acceleration duration and negatively correlated with the CME peak acceleration. For the majority of the events the CME acceleration starts before the flare onset (for 75% of the events) and the CME acceleration ends after the soft X-ray (SXR) peak time (for 77% of the events). In {approx}60% of the events, the time difference between the peak time of the flare SXR flux derivative and the peak time of the CME acceleration is smaller than {+-}5 minutes, which hints at a feedback relationship between the CME acceleration and the energy release in the associated flare due to magnetic reconnection.

79 ASTRONOMY AND ASTROPHYSICS↗

New Method to Characterize Degradation of First Surface Aluminum Reflectors: Preprint

This paper reports the development of a new optical instrument capable of characterizing the aging process of enhanced first surface aluminum reflectors for concentrating solar power (CSP) application. Samples were exposed outdoors at different sites and in accelerated exposure tests. All samples exposed outdoors showed localized corrosion spots. Degradation originated from points of damage inthe protective coating, but propagated underneath the protective coating. The degraded samples were analyzed with a microscope and with a newly designed space-resolved specular reflectometer (SR)2 that is capable of optically detecting and characterizing the corrosion spots. The device measures the specular reflectance at three acceptance angles and the wavelengths with spatial resolution usinga digital camera's CMOS sensor. It can be used to measure the corrosion growth rate during outdoor and accelerated exposure tests. These results will allow a correlation between the degraded mirror surface and its specular reflectance.

14 SOLAR ENERGY↗