Nonlinear ultrasonic characterization of precipitation in 17-4PH stainless steel
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Despite the progress in understanding the formation and migration of oxygen vacancies in strongly correlated complex oxides, few studies focused on the dynamic behaviors of the oxygen vacancies under the transient and non-equilibrium states. Here we report a series of multi-timescale ultrafast X-ray diffraction experiments using picosecond synchrotron and femtosecond table-top X-ray sources to monitor the structural dynamics in oxygen-vacancy-ordered SrCoO 2.5 thin films excited by photons. A giant photoinduced structure distortion in c-axis direction (with strain $Δc/c$ > 1%) was observed, higher than any previously reported data in the other transition metal oxide films. The femtosecond X-ray diffraction reveals the formation and propagation of the coherent acoustic phonons, indicating an instantaneous and a much larger photoinduced stress within the first 100 ps. Density Function Theory reproduced the photostrictive responses and the strong dependence on excitation wavelength as observed in the experiment. The combined experimental and theoretic results demonstrate that the photoexcitation of bonding to antibonding state via charge transfer is the dominant mechanism in the SrCoO 2.5 thin films distinct from the depolarization effect by photoinduced carriers in the other perovskite oxides.
A vibration welding system includes vibration welding equipment having a welding horn and anvil, a host device, a check station, and a robot. The robot moves the horn and anvil via an arm to the check station. Sensors, e.g., temperature sensors, are positioned with respect to the welding equipment. Additional sensors are positioned with respect to the check station, including a pressure-sensitive array. The host device, which monitors a condition of the welding equipment, measures signals via the sensors positioned with respect to the welding equipment when the horn is actively forming a weld. The robot moves the horn and anvil to the check station, activates the check station sensors at the check station, and determines a condition of the welding equipment by processing the received signals. Acoustic, force, temperature, displacement, amplitude, and/or attitude/gyroscopic sensors may be used.
In this paper, we demonstrate a multi-parameter fiber sensing system based on stimulated Brillouin scattering in a double-Brillouin peak specialty fiber with enhanced Brillouin gain response. The amplitude level of the second Brillouin gain peak, which originated from the higher-order acoustic modes, has been improved with an approximately similar amplitude level to the first Brillouin gain peak from the fundamental acoustic mode. Compared to other multi-Brillouin peak fibers presented in the literature, the proposed fiber significantly reduces the measured Brillouin frequency shift error, thus improving strain and temperature accuracies. By utilizing the sensitivity values of the strain and temperature associated with each Brillouin gain spectrum (BGS) peak, a successful discriminative measurement of strain and temperature is performed with an accuracy of ±13 μɛ, and ±0.5 °C, respectively. The proposed double-Brillouin peak fiber appears to be a possible alternative to other multi-BGS peak fibers, for instance, large effective area fiber and dispersion compensating fibers, which are inherently accompanied by large measurement errors due to the weak Brillouin gain values originating from the higher-order acoustic modes. The demonstrated results show different strain and temperature coefficients of 47 kHz/µɛ, 1.15 MHz/°C for peak 1 and 51 kHz/µɛ, 1.37 MHz/°C for peak 2. Moreover, the enhanced BGS peak gains having nearly the same amplitude levels enable the discriminative measurement of strain and temperature. Such fibers in Brillouin interrogation eliminate the need for complex monitoring setups and reduce measurement errors. We recommend that for long-distance natural gas pipeline monitoring, where discriminative strain and temperature measurement is crucial, the proposed double-Brillouin peak fiber can be highly beneficial.
Acoustic emission (AE) patterns were measured during pressure testing of advanced composite rocket motor cases made of boron/epoxy and graphite/epoxy. Both accelerometers and high frequency AE transducers were used, and both frequency spectrum and amplitude distribution were studied. The AE patterns suggest that precursor emission might be used in certain cases to anticipate failure. The technique of hold-cycle AE monitoring was also evaluated and could become a valuable decision gate for test continuation/termination. Data presented show similarity of accelerometers and AE transducer responses despite the different frequency response, and suggest that structural AE phenomena are broadband.
This easy-to-operate, cost-effective, tabletop purge-and-trap gas chromatograph ensures safe drinking water and monitors disinfection by-product formation at water utilities in real-time without sample preparation or off-site analysis.
Abrupt, local frictional fault failure comprises a displacement that is normally accompanied by acoustic emission (AE)—an impulsive elastic wave broadcast with an amplitude proportional to particle velocity. The aggregate of these displacements is the basic fault motion. In laboratory shear experiments, the examination of a sequence of laboratory earthquakes includes continuous measurements of fault motion and the associated AE that is broadcast. From these measurements, connections between the fault motion and cumulative sum of the AE amplitude can be identified. The composition of the AE broadcasts reveals inhomogeneity in the fault mechanical structure from which they arise. This inhomogeneity can be decomposed into a time invariant AE component and an articulated AE component. The articulated AE component serves as a “state of the fault diagnostic” that follows a distinctive pattern to fault failure. Thus, the articulated AE component can be used directly to monitor the state of the fault.
We directly monitored the lattice dynamics in PbSe quantum dots induced by laser excitation using ultrafast electron di raction. The energy relaxation between the carriers and the lattice took place within 10 ps, showing no evidence of any signi cant phonon bottleneck e ect. Meanwhile, the lattice dilation exhibited some unusual features that could not be explained by the available mechanisms of photon- induced acoustic vibrations in semiconductors alone. The heat transport between the QDs and the substrate deviates signi cantly from Fourier's Law, which opens questions about the heat transfer under nonequilibrium conditions in nanoscale materials.
This report serves as the first delivery of a four-year applied science effort to transform and advance the error bounds for the yield estimate of an explosion. Each year’s delivery will be in this form, culminating in the submission of this work for peer review to a scientific journal. Importantly, the yearly progress reports can then also be viewed as expanding drafts working towards a formal journal article submission. For the first tranche of funding, we collaborated with Air Force Technical Applications Center (AFTAC) scientists to identify unclassified real-world data that demonstrate and validate our advanced error propagation methods. Collaboration includes visits to AFTAC and telecons. For this development, we illustrate the fusion of seismic, acoustic, optical, and surface effect signatures from an explosion. The mathematics and code being adapted to this specific application (Williams et al., 2021) involves physics models of multiple sensor signatures. We have also identified related physics models and have integrated them into code. Current methods of underground explosion yield estimation for the Threshold Test Ban Treaty (TTBT) have served the US treaty monitoring mission well for decades. A research objective of the Defense Nuclear Nonproliferation Research and Development (DNN R&D) office of the National Nuclear Security Administration (NNSA) has always been to provide new technical capabilities for monitoring lower thresholds. The general model and error propagation code to be developed in this project is based on significant advances in error modeling and propagation needed to analyze data at lower detection thresholds. The second tranche of funding for this project began on May 1, 2022, and planned work for the second tranche includes: i) completing the integration of physical model code into the general error model framework; this code accommodates a wide range of linear/nonlinear source models, fixed/ random effects, and frequentist/Bayesian analyses (the purpose of which is not to dictate to users how to analyze data, but instead to allow users the maximum flexibility in their work); ii) illustrative application of code to identified data, and; iii) initial planning with AFTAC researchers on delivery of code to the Common Development Environment at AFTAC, and continued writing of the planned final journal article submission (year two of this progress report), with particular emphasis on descriptions of data identified for this effort.
Plasma sprayed coatings have a complex structure which is produced by the overlaying of many molten or semi-molten particles in the diameter range of 20 to 120 microns. The failure behavior of coatings has been characterized by using acoustic emission (AE) methodology. Coatings of NiCrAlY bond coat with a zirconia-12 wt pct yttria overlay were applied to disk-shaped specimens of U-700 alloy. A waveguide of 1-mm diameter platinum was TlG welded to the specimen and allowed it to be suspended in a tubular furnace. The specimen was thermally cycled to 1150 C and the AE monitored. Analyses have been carried out with the aim of establishing parameters which are related to the crack size population. These studies have been used to postulate types of cracking mechanisms which may occur in plasma sprayed coatings during thermal cycling. It is shown that microcracking gave rise to a large amount of AE. However, this coating still survived more thermal cycles than a coating which exhibited macrocracking events.
Aircraft engine rotating equipment operates at high temperatures and stresses. Noninvasive inspection of microcracks in those components poses a challenge for nondestructive evaluation. A low-cost, low-profile, high-temperature ultrasonic guided wave sensor was developed that detects cracks in situ. The transducer design provides nondestructive evaluation of structures and materials. A key feature of the sensor is that it withstands high temperatures and excites strong surface wave energy to inspect surface and subsurface cracks. The sol-gel bismuth titanate-based surface acoustic wave (SAW) sensor can generate efficient SAWs for crack inspection. The sensor is very thin (submillimeter) and can generate surface waves up to 540 C. Finite element analysis of the SAW transducer design was performed to predict the sensor behavior, and experimental studies confirmed the results. The sensor can be implemented on structures of various shapes. With a spray-coating process, the sensor can be applied to the surface of large curvatures. It has minimal effect on airflow or rotating equipment imbalance, and provides good sensitivity.
We report high temperature surface acoustic wave (SAW) gas sensors with conducting sensing layers require tuning of the sheet conductivity for optimal response. Conducting metal oxides are attractive sensing materials for their tunable electronic properties and high thermal stability, amongst others. Here, we have investigated the application of indium oxide (IO) and indium tin oxide (ITO) films on langasite (LGS)-based SAW reflective delay line sensor devices for monitoring hydrogen at 350 °C. Specifically, we modeled the effect of the IO and ITO sensing layer thickness on the wave velocity, attenuation, and effective electromechanical coefficient. This was followed by an experimental demonstration of tuning of the ITO film sheet conductivity by controlling the dopant concentration and yielding an improvement in the sensor sensitivity. The current study provides a pathway towards the development of conductivity-based sensing layers for high temperature SAW gas sensors with improved sensitivity.
This study was mainly focused on evaluating the route-specific passage and migration success of steelhead kelts passing downstream through The Dalles Dam (TDA) and Bonneville Dam (BON) at Columbia River (CR) river kilometers 309 and 234 respectively. Oregon Department of Fish and Wildlife (ODFW) personnel collected, tagged and released out-migrating steelhead kelts in the tributaries of the Deschutes River, 15 Mile Creek and Hood River between April 14 and June 4, 2012. A PIT tag was injected into each kelt’s dorsal sinus whereas a Juvenile Salmon Acoustic Telemetry System (JSATS) acoustic micro-transmitter was attached to an external FLoy T-bar tag and inserted into the dorsal back musculature using a Floy tagging gun. JSATS cabled arrays were deployed at TDA and BON and autonomous node arrays were deployed near Celilo, Oregon (CR325); the BON forebay (CR236); the BON tailrace (CR233); near Knapp, Washington (CR156); and near Kalama, Washington (CR113) to monitor the kelts movement while passing through the dams and above mentioned river cross-sections.
The Source Physics Experiment series is a long-term research and development (R&D) effort under the U.S. Department of Energy’s National Nuclear Security Administration focused on improving the physical understanding of how chemical explosions generate seismoacoustic signals. Beginning in 2011, a series of subsurface chemical explosions in two different and highly contrasting geologies were conducted at the Nevada National Security Site in Nevada, USA with the objective of improving simulation and modeling approaches to explosion identification, yield estimation and other monitoring applications. The two executed phases of the series provide new explosion signature source data from a wide range of geophysical diagnostic equipment; recorded data from the test series is now openly available to the broader seismoacoustic community. This manuscript details the executed test series, deployed seismoacoustic networks, and summarizes major scientific achievements utilizing recorded signatures from the explosive tests.
ModalMax is a very innovative means of harnessing the vibration of a piezoelectric actuator to produce an energy efficient low-profile device with high-bandwidth high-fidelity audio response. The piezoelectric audio device outperforms many commercially available speakers made using speaker cones. The piezoelectric device weighs substantially less (4 g) than the speaker cones which use magnets (10 g). ModalMax devices have extreme fabrication simplicity. The entire audio device is fabricated by lamination. The simplicity of the design lends itself to lower cost. The piezoelectric audio device can be used without its acoustic chambers and thereby resulting in a very low thickness of 0.023 in. (0.58 mm). The piezoelectric audio device can be completely encapsulated, which makes it very attractive for use in wet environments. Encapsulation does not significantly alter the audio response. Its small size (see Figure 1) is applicable to many consumer electronic products, such as pagers, portable radios, headphones, laptop computers, computer monitors, toys, and electronic games. The audio device can also be used in automobile or aircraft sound systems.
The Electric Power Research Institute (EPRI) Nuclear Sector and US Department of Energy Light Water Reactor Sustainability Program are committed to engaging in research and development endeavors to address materials aging issues specific to long term operation of light water power reactors. To this effect, EPRI launched an industry initiative to develop nondestructive evaluation systems for online monitoring of existing cracks in light water reactor primary coolant loop piping and components. One of the goals of this initiative is to develop a sensor system (or systems) that can determine nondestructively if cracks are growing or arrested and, in the case of the former, to characterize their growth rates. A missing component of this initiative is an experimental assessment of how sensors and adhesive couplants will perform in service when exposed to chronic energetic neutron radiation, particularly at the primary coolant loop hot and cold leg dissimilar metal welds, which join the primary loop piping to the reactor pressure vessel and reside in the vicinity of the reactor core. The objective of this experimental study was to determine how ultrasonic transducers and adhesive couplants perform when exposed to irradiation in a test reactor to simulate and accelerate in-service exposure. Further, to achieve this objective, the signal stability of piezoelectric transducers and performance of adhesive couplants as a function of accumulated fast neutron fluence were characterized by collecting ultrasonic data in-situ during irradiation. Of particular interest were the ultrasonic signal quality and time decay of the amplitude of acoustic reflections as a function of fast neutron fluence. The results of the study showed that, of the 8 transducer/substrate sample assemblies tested, only 3 generated usable ultrasonic signals through the conclusion of the irradiation campaign. It was found that high temperature epoxy tends to ultrasonically couple the sensors to the substrates better than three types of refractory ceramic cements studied, as is supported by post irradiation examination. The results obtained through this experimental study will be utilized in the achievement of the overall goal of development of a sensor system to perform online monitoring of primary loop components.
The explosive fragmentation of the 2013 Chelyabinsk meteorite generated a large airburst with an equivalent yield of 500 kT TNT. It is the most energetic event recorded by the infrasound component of the Comprehensive Nuclear-Test-Ban Treaty-International Monitoring System (CTBT-IMS), globally detected by 20 out of 42 operational stations. This study performs a station-by-station estimation of the IMS detection capability to explain infrasound detections and nondetections from short to long distances, using the Chelyabinsk meteorite as global reference event. Investigated parameters influencing the detection capability are the directivity of the line source signal, the ducting of acoustic energy, and the individual noise conditions at each station. Findings include a clear detection preference for stations perpendicular to the meteorite trajectory, even over large distances. Only a weak influence of stratospheric ducting is observed for this low-frequency case. As a result, a strong dependence on the diurnal variability of background noise levels at each station is observed, favoring nocturnal detections.
Reliability modeling and parametric yield prediction of GaAs/AlGaAs multiple quantum well (MQW) avalanche photodiodes (APDs), which are of interest as an ultra-low noise image capture mechanism for high definition systems, have been investigated. First, the effect of various doping methods on the reliability of GaAs/AlGaAs multiple quantum well (MQW) avalanche photodiode (APD) structures fabricated by molecular beam epitaxy is investigated. Reliability is examined by accelerated life tests by monitoring dark current and breakdown voltage. Median device lifetime and the activation energy of the degradation mechanism are computed for undoped, doped-barrier, and doped-well APD structures. Lifetimes for each device structure are examined via a statistically designed experiment. Analysis of variance shows that dark-current is affected primarily by device diameter, temperature and stressing time, and breakdown voltage depends on the diameter, stressing time and APD type. It is concluded that the undoped APD has the highest reliability, followed by the doped well and doped barrier devices, respectively. To determine the source of the degradation mechanism for each device structure, failure analysis using the electron-beam induced current method is performed. This analysis reveals some degree of device degradation caused by ionic impurities in the passivation layer, and energy-dispersive spectrometry subsequently verified the presence of ionic sodium as the primary contaminant. However, since all device structures are similarly passivated, sodium contamination alone does not account for the observed variation between the differently doped APDs. This effect is explained by the dopant migration during stressing, which is verified by free carrier concentration measurements using the capacitance-voltage technique.