Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transient behavior”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Energetics of an rf SQUID Coupled to Two Thermal Reservoirs

We study energetics of a Josephson tunnel junction connecting a superconducting loop pierced by an external magnetic flux (an rf SQUID) and coupled to two independent thermal reservoirs of different temperature. In the framework of the theory of quantum dissipative systems, we analyze energy currents in stationary states. The stationary energy flow can be periodically modulated by the external magnetic flux exemplifying the rf SQUID as a quantum heat interferometer. Additionally, we consider the transient regime and identify three distinct regimes: monotonic decay, damped oscillations and pulse-type behavior of energy currents. Furthermore, the first two regimes can be controlled by the external magnetic flux while the last regime is robust against its variation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear transient responses of structures by the spatial finite-element method.

Based upon the Principle of Virtual Work and D'Alembert's Principle, the assumed-displacement version of the spatial finite-element method is developed to predict the large deflection transient responses of structures including elastic-plastic, strain hardening, and strain-rate material behavior. The formulations are developed in detail for curved beamlike structures undergoing planar (1) Bernouilli-Euler-type or (2) Timoshenko-type deformation behavior. The resulting equations of motion are solved timewise by a finite-difference numerical procedure. The present predictions are evaluated via several beam and ring examples for which experimental measurements and independent finite-difference predictions in both space and time are available; very good agreement is noted. The consequences of employing several types of timewise finite-difference operators are examined. Also, some comparisons between finite-element predictions and finite-difference predictions are shown to illustrate 'typical comparisons' of efficiency for a given prediction accuracy.

Wu, R. W.-H.↗

Mixed time integration methods for transient thermal analysis of structures, appendix 5

Mixed time integration methods for transient thermal analysis of structures are studied. An efficient solution procedure for predicting the thermal behavior of aerospace vehicle structures was developed. A 2D finite element computer program incorporating these methodologies is being implemented. The performance of these mixed time finite element algorithms can then be evaluated employing the proposed example problem.

Liu, W. K.↗

Behavior Of Joint Seal In Solid Rocket Booster

Report analyzes behavior of O-ring seals in case of Solid Rocket Booster. Numerical simulations of transient response of seal presented with measurements of relevant mechanical properties of O-rings to show there is range of operating conditions in which seal can fail.

Moore, Carleton J.↗

Analytical and experimental study of vibrations in a gear transmission

An analytical simulation of the dynamics of a gear transmission system is presented and compared to experimental results from a gear noise test rig at NASA Lewis. The analytical procedure developed couples the dynamic behaviors of the rotor-bearing-gear system with the response of the gearbox structure. Transient and steady-state vibrations of the gearbox system are presented in the time and frequency domains. The vibration characteristics of a simple single-mesh-gear noise test rig are modeled. The numerical simulations are compared to experimental data measured under typical operating conditions. The system natural frequencies, peak vibration amplitudes, and gear mesh frequencies are generally in good agreement.

Choy, F. K.↗

Results of an experimental investigation of the flow field in the head-end star slot section of a Solid Rocket Motor

Cold flow tests of a one-tenth scale model based on the geometry of the Space Shuttle Solid Rocket Motor, SRM, head-end section and its single-port igniter, along with two models of a four port igniter, have been conducted. The tests were done to establish quantitative as well as qualitative data on the behavior of the flow inside the star slot during the early part of the ignition transient. This paper presents the data obtained from these tests and discusses the implications of the data with respect to ignition transients of solid rocket motors which have head-end star grains.

Ciucci, A.↗

Visualizing the thermal performance of heat pipes with thermochromic liquid crystals

A novel technique has been developed to visualized the thermal performance characteristics of simple low temperature heat pipes and thermosyphons. Copper heat pipes with internal, annular mesh wicks and charged with Refrigerant-12 were externally coated with thermochromic liquid crystal (TLC) paints. The thermally sensitive TLC coating reversibly changes color upon heating and readily permits visual identification of transient and steady state isotherms during low temperature operation. The start-up and operational behaviors of the heat pipe as well as the presence of non-condensible gases can be visually identified through a spectrum of color changes. A brief video demonstration illustrating heat pipe thermal performance characteristics has been developed and illustrates the utility of TLCs for visualizing thermal behavior.

Gunnerson, Fred S.↗

A study of forced convection boiling under reduced gravity

This report presents the results of activities conducted over the period 1/2/85-12/31/90, in which the study of forced convection boiling under reduced gravity was initiated. The study seeks to improve the understanding of the basic processes that constitute forced convection boiling by removing the buoyancy effects which may mask other phenomena. Specific objectives may also be expressed in terms of the following questions: (1) what effects, if any, will the removal of body forces to the lowest possible levels have on the forced convection boiling heat transfer processes in well-defined and meaningful circumstances? (this includes those effects and processes associated with the nucleation or onset of boiling during the transient increase in heater surface temperature, as well as the heat transfer and vapor bubble behaviors with established or steady-state conditions); and (2) if such effects are present, what are the boundaries of the relevant parameters such as heat flux, heater surface superheat, fluid velocity, bulk subcooling, and geometric/orientation relationships within which such effects will be produced?

Merte, Herman, Jr.↗

Heat Pipe Vapor Dynamics

The dynamic behavior of the vapor flow in heat pipes is investigated at startup and during operational transients. The vapor is modeled as two-dimensional, compressible viscous flow in an enclosure with inflow and outflow boundary conditions. For steady-state and operating transients, the SIMPLER method is used. In this method a control volume approach is employed on a staggered grid which makes the scheme very stable. It is shown that for relatively low input heat fluxes the compressibility of the vapor flow is low and the SIMPLER scheme is suitable for the study of transient vapor dynamics. When the input heat flux is high or the process under a startup operation starts at very low pressures and temperatures, the vapor is highly compressible and a shock wave is created in the evaporator. It is shown that for a wide range of input heat fluxes, the standard methods, including the SIMPLER scheme, are not suitable. A nonlinear filtering technique, along with the centered difference scheme, are then used for shock capturing as well as for the solution of the cell Reynolds-number problem. For high heat flux, the startup transient phase involves multiple shock reflections in the evaporator region. Each shock reflection causes a significant increase in the local pressure and a large pressure drop along the heat pipe. Furthermore, shock reflections cause flow reversal in the evaporation region and flow circulations in the adiabatic region. The maximum and maximum-averaged pressure drops in different sections of the heat pipe oscillate periodically with time because of multiple shock reflections. The pressure drop converges to a constant value at steady state. However, it is significantly higher than its steady-state value at the initiation of the startup transient. The time for the vapor core to reach steady-state condition depends on the input heat flux, the heat pipe geometry, the working fluid, and the condenser conditions. However, the vapor transient time, for an Na-filled heat pipe is on the order of seconds. Depending on the time constant for the overall system, the vapor transient time may be very short. Therefore, the vapor core may be assumed to be quasi-steady in the transient analysis of a heat pipe operation.

Issacci, Farrokh↗

Reconfigurable Control with Neural Network Augmentation for a Modified F-15 Aircraft

This paper describes the performance of a simplified dynamic inversion controller with neural network supplementation. This 6 DOF (Degree-of-Freedom) simulation study focuses on the results with and without adaptation of neural networks using a simulation of the NASA modified F-15 which has canards. One area of interest is the performance of a simulated surface failure while attempting to minimize the inertial cross coupling effect of a [B] matrix failure (a control derivative anomaly associated with a jammed or missing control surface). Another area of interest and presented is simulated aerodynamic failures ([A] matrix) such as a canard failure. The controller uses explicit models to produce desired angular rate commands. The dynamic inversion calculates the necessary surface commands to achieve the desired rates. The simplified dynamic inversion uses approximate short period and roll axis dynamics. Initial results indicated that the transient response for a [B] matrix failure using a Neural Network (NN) improved the control behavior when compared to not using a neural network for a given failure, However, further evaluation of the controller was comparable, with objections io the cross coupling effects (after changes were made to the controller). This paper describes the methods employed to reduce the cross coupling effect and maintain adequate tracking errors. The IA] matrix failure results show that control of the aircraft without adaptation is more difficult [leas damped) than with active neural networks, Simulation results show Neural Network augmentation of the controller improves performance in terms of backing error and cross coupling reduction and improved performance with aerodynamic-type failures.

Burken, John J.↗

CFD Simulations of Supersonic Highly Swirling Flow Exiting a Turbine Vane Row Compared with Experimental Observations

Marshall Space Flight Center (MSFC) has been heavily involved in developing the J2-X engine. The Center has been testing a Work Horse Gas Generator (WHGG) to supply gas products to J2-X turbine components at realistic flight-like operating conditions. Three-dimensional time accurate CFD simulations and analytical fluid analysis have been performed to support WHGG tests at MSFC. The general purpose CFD program LOCI/Chem was utilized to simulate flow of products from the WHGG through a turbine manifold, a stationary row of turbine vanes, into a Can and orifice assembly used to control the back pressure at the turbine vane row and finally through an aspirator plate and flame bucket. Simulations showed that supersonic swirling flow downstream of the turbine imparted a much higher pressure on the Can wall than expected for a non-swirling flow. This result was verified by developing an analytical model that predicts wall pressure due to swirling flow. The CFD simulations predicted that the higher downstream pressure would cause the pressure drop across the nozzle row to be approximately half the value of the test objective. With CFD support, a redesign of the Can orifice and aspirator plate was performed. WHGG experimental results and observations compared well with pre-test and post-test CFD simulations. CFD simulations for both quasi-static and transient test conditions correctly predicted the pressure environment downstream of the turbine row and the behavior of the gas generator product plume as it exited the WHGG test article, impacted the flame bucket and interacted with the external environment.

West, Jeff S.↗

Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources: Preprint

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Hindered segmental dynamics in associative protein hydrogels studied by neutron spin-echo spectroscopy

Transient binding between associating macromolecules can cause qualitative changes to chain dynamics, including modes of conformational relaxation and diffusion, through tethering effects imparted by long-range connectivity. Here, in this work, the role of binding on short-time segmental dynamics in associative polymer gels is investigated by neutron spin-echo (NSE) measurements on a class of model artificial coiled-coil proteins with a systematically varied architecture, probing timescales of 0.1–130 ns, and length scales close to the molecular radius of gyration. The results illustrate effects of transient cross-linking on chain dynamics on different timescales, manifested in changes in segmental relaxation behavior with variations in strand length, chain concentration, and sticker distribution (endblock- vs midblock-functionalized). In all gels, a short-time cooperative diffusion mode is seen over all wave vectors, analogous to a semidilute solution, with no transitions seen at any known structural length scale. However, the diffusion coefficients are found to decrease with increasing junction density across all gels, with the strand length and number of stickers per chain in each gel appearing to play a relatively minor role. The slowing of cooperative diffusion with junction density contrasts with classical predictions of a greater restoring force for fluctuation dissipation due to the increased elasticity, suggesting additional effects of the coiled-coil junctions such as an enhancement in local viscosity that slows dynamics. Notably, the relaxation rates for all gels can be rescaled by the interjunction spacing inferred from small-angle neutron scattering, where they collapse onto a master curve suggestive of self-similar dynamics even in networks with different strand lengths and chain architectures. On long timescales (but shorter than the junction exchange time), a slowing of network relaxation is observed, resulting in a nondecaying plateau in the spin-echo amplitude attributed to a freezing of chain dynamics due to tethering. A characteristic length scale corresponding to the extent of dynamic fluctuations is estimated for each gel, which appears to be smaller than the interjunction spacing but similar to the correlation blob size of the overlapping strands. The results indicate an important role of transient binding on molecular-scale dynamics in associative polymer gels, even on timescales shorter than the junction exchange time, in addition to its effects on long-range self-diffusion previously observed.

36 MATERIALS SCIENCE↗

Molecular flow venting of a volume with an outgassing or desorbing source

A venting equation commonly used to describe the transient evolution of pressure within a volume containing an outgassing or offgassing source and a restrictive vent conductance under conditions of molecular flow has been solved analytically. Solutions are found for sources of finite thickness characterized by classical diffusion-limited behavior (proportional to inverse square root of time), as well as responses for thick material sources often observed in testing that are characterized by a more general form of power-law decay, up to inverse time behavior associated with surface desorption. Solutions involve evaluating integrals where both numerators and denominators of the integrands diverge with time, making wide-ranging transient solutions difficult to directly compute numerically. Usually, one can avoid evaluating these integrals by assuming quasistatic conditions at long time scales. A novel approach is used in this work to analytically produce solutions by generating bespoke mathematical functions, some of which solve integrals that have apparently had no previous analytical solution.

Michael Woronowicz↗

Molecular flow venting of a volume with an outgassing or desorbing source

"A venting equation commonly used to describe the transient evolution of pressure within a volume containing an outgassing or offgassing source and a restrictive vent conductance under conditions of molecular flow has been solved analytically. Solutions are found for sources of finite thickness characterized by classical diffusion-limited behavior (proportional to inverse square root of time), as well as responses for thick material sources often observed in testing that are characterized by a more general form of power-law decay, up to inverse time behavior associated with surface desorption. Solutions involve evaluating integrals where both numerators and denominators of the integrands diverge with time, making wide-ranging transient solutions difficult to directly compute numerically. Usually, one can avoid evaluating these integrals by assuming quasistatic conditions at long time scales. A novel approach is used in this work to analytically produce solutions by generating bespoke mathematical functions, some of which solve integrals that have apparently had no previous analytical solution."

Michael Woronowicz↗

A study of high-temperature heat pipes with multiple heat sources and sinks. I - Experimental methodology and frozen startup profiles. II - Analysis of continuum transient and steady-state experimental data with numerical predictions

Experimental profiles for heat pipe startup from the frozen state were obtained, using a high-temperature sodium/stainless steel pipe with multiple heat sources and sinks to investigate the startup behavior of the heat pipe for various heat loads and input locations, with both low and high heat rejection rates at the condensor. The experimental results of the performance characteristics for the continuum transient and steady-state operation of the heat pipe were analyzed, and the performance limits for operation with varying heat fluxes and location are determined.

Faghri, A.↗

Modular high temperature gas reactor core modeling with RELAP5-3D/PHISICS – Optimization schemes for load following

The objective of this study is to develop a 3D/NK model to study the load following operation of a Modular High-Temperature Gas-Cooled Reactor (MHTGR). The selected design is the 350 MW prismatic, graphite moderated, helium cooled thermal reactor based on the MHTGR-350 transient benchmark led by the High-Temperature Gas-Cooled Reactor (HTGR) Methods Core Simulation Group at Idaho National Laboratory (INL) in the framework of the Organization for Economic Cooperation and Development Nuclear Energy Agency (OECD/NEA). This kind of reactor usually reacts very slowly to the perturbation of the core parameters due to the large amount of graphite in the core. This kind of behavior promotes the reactor stability but on the other hand limits the reactor load-following operability. Recently advances in gas reactor designs have made load-following in gas reactors a feasible and achievable goal. Modern nuclear reactors (such as the MHTGR-350) are designed to withstand the structural stresses associated with load-following. Operating the reactor in load-following mode will inevitably reduce the load factor. Although a higher load factor means more revenue and the best usage of the fuel, following the variable energy demand will increase the maximum achievable fraction of generated nuclear power, being no more limited to the base load power generation. In general, if low impact on material aging and the safe operability are demonstrated the plant economics will be minimally affected. In order to ensure that the system can be safely operated in a load-following mode an extensively study has been carried out. Some tests with linear coolant mass flow rate change demonstrated that the reactor behavior is suitable for operation in load following mode. This assumption has been confirmed by a 4 days load following transient test in which the reactor supplied the requested power with a negligible error.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗