Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “telemetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Solar proton, helium, and medium nuclei (Z is equal to or greater than 6 and equal to or less than 9) observed from the IMP-6 satellite

Proton, helium, and medium nuclei energy spectra have been measured from the Explorer 35 satellite for a recent solar flare. Above 2 MeV/nucleon these spectra are based upon single and dual parameter pulse height analysis in addition to threshold rate counting. Pulse height analysis of medium nuclei is assigned a high priority for telemetry readout so that telemetry does not become saturated by the high proton intensity. In this manner the number of pulse height analyzed medium nuclei has been increased by a factor of approximately 200. Individual medium nuclei have been resolved in the energy interval 8 - 23 MeV/nucleon.

Vonrosenvinge, T. T.↗

Tracking and data system support for the Mariner Mars 1971 mission. Prelaunch phase through first trajectory correction maneuver, volume 1

The DSN command system provided the capability to enter commands in a computer at the deep space stations for transmission to the spacecraft. The high-rate telemetry system operated at 16,200 bits/sec. This system will permit return to DSS 14 of full-resolution television pictures from the spacecraft tape recorder, plus the other science experiment data, during the two playback periods of each Goldstone pass planned for each corresponding orbit. Other features included 4800 bits/sec modem high-speed data lines from all deep space stations to Space Flight Operations Facility (SFOF) and the Goddard Space Flight Center, as well as 50,000 bits/sec wideband data lines from DSS 14 to the SFOF, thus providing the capability for data flow of two 16,200 bits/sec high-rate telemetry data streams in real time. The TDS performed prelaunch training and testing and provided support for the Mariner Mars 1971/Mission Operations System training and testing. The facilities of the ETR, DSS 71, and stations of the MSFN provided flight support coverage at launch and during the near-earth phase. The DSSs 12, 14, 41, and 51 of the DSN provided the deep space phase support from 30 May 1971 through 4 June 1971.

Laeser, R. P.↗

Apollo portable life support system performance report

The performance of the Apollo portable life support system (PLSS) on actual lunar missions is discussed. Both subjective comments by the crewmen and recorded telemetry data are evaluated although emphasis is on the telemetry data. Because the most important information yielded by the PLSS deals with determination of crewman metabolic rates, these data and their interpretation are explained in detail. System requirements are compared with actual performance, and the effect of performance margins on mission planning are described. Mission preparation testing is described to demonstrate how the mission readiness of the PLSS and the crewmen in verified, and to show how the PLSS and the crewmen are calibrated for mission evaluation.

Carson, M. A.↗

Feasibility study: Replacement of the inoperative decommutating buffer subsystem for the instrumentation checkout complex in the Quality and Reliability Assurance Laboratory

A general purpose computer system, that is necessary for replacement of the present inoperative signal decommutator special purpose computer subsystem is described. The present decommutator subsystem has a very poor history of reliability and since April 1970, it has become inoperative because the core memory cannot be repaired. Functions of the present signal, decommutator subsystem are to receive, demultiplex, record in real time, playback in real time, and output to the SDS-930 control computer for analysis of the telemetry data. Recommendations for replacement of the inoperative telemetry decommutator subsystem are for the purchase of a mini-computer.

Hilliard, J. W.↗

Interplex: An analysis of optimized power allocations for two and three channel PSK/PM telecommunications systems

Optimal design concepts are presented for two- and three-channel telemetry modes in the context of the Mariner Venus-Mercury 1973 mission and the usefulness of interplex modulation techniques is discussed. These ideas are applied as an example to one Mariner Venus-Mercury 1973 telemetry mode to demonstrate that interplex can reduce the required total average power by more than 2 dB in some cases.

Levitt, B. K.↗

The charge spectra of solar cosmic rays

An approach to measuring charged spectra of solar cosmic rays is considered. These observations were made by a telescope on the IMP 6 satellite. The charge range was extended beyond charge 2 up to charge 26, and the energy range was extended to lower energies. The experiment preferentially selects rare events above charge 2 and gives them top priority for telemetry readout, thus breaking the monopoly that protons and helium nuclei otherwise would have on the telemetry. This effectively increases the number of nuclei observed above charge 2 by a factor of several hundred.

Vonrosenvinge, T. T.↗

Flight-test experience in digital control of a remotely piloted vehicle.

The development of a remotely piloted vehicle system consisting of a remote pilot cockpit and a ground-based digital computer coupled to the aircraft through telemetry data links is described. The feedback control laws are implemented in a FORTRAN program. Flight-test experience involving high feedback gain limits for attitude and attitude rate feedback variables, filtering of sampled data, and system operation during intermittent telemetry data link loss is discussed. Comparisons of closed-loop flight tests with analytical calculations, and pilot comments on system operation are included.

Edwards, J. W.↗

Star sensor/mapper with a self deployable, high-attenuation light shade for SAS-B

A star sensor/mapper to determine positional data for the small astronomy satellites was tested to detect stars of plus 4 visual magnitude. It utilizes two information channels with memory so that it can be used with a low-data-rate telemetry system. One channel yields star amplitude information; the other yields the time of star occurrence as the star passes across an N-slit reticle/photomultiplier detector system. Some of the features of the star sensor/mapper are its low weight of 6.5 pounds, low power consumption of 0.4 watt, bandwidth switching to match the satellite spin rate, optical equalization of sensitivity over the 5-by-10 deg field of view, and self-deployable sunshade. The attitude determination accuracy is 3 arc minutes. This is determined by such parameters as the reticle configuration, optical train, and telemetry readout. The optical and electronic design of the star sensor/mapper, its expansion capabilities, and its features are discussed.

Schenkel, F. W.↗

Atmosphere Explorer control system software (version 1.0)

The basic design is described of the Atmosphere Explorer Control System (AECS) software used in the testing, integration, and flight contol of the AE spacecraft and experiments. The software performs several vital functions, such as issuing commands to the spacecraft and experiments, receiving and processing telemetry data, and allowing for extensive data processing by experiment analysis programs. The major processing sections are: executive control section, telemetry decommutation section, command generation section, and utility section.

Villasenor, A.↗

Atmosphere Explorer control system software (version 2.0)

The Atmosphere Explorer Control System (AECS) was developed to provide automatic computer control of the Atmosphere Explorer spacecraft and experiments. The software performs several vital functions, such as issuing commands to the spacecraft and experiments, receiving and processing telemetry data, and allowing for extensive data processing by experiment analysis programs. The AECS was written for a 48K XEROX Data System Sigma 5 computer, and coexists in core with the XDS Real-time Batch Monitor (RBM) executive system. RBM is a flexible operating system designed for a real-time foreground/background environment, and hence is ideally suited for this application. Existing capabilities of RBM have been used as much as possible by AECS to minimize programming redundancy. The most important functions of the AECS are to send commands to the spacecraft and experiments, and to receive, process, and display telemetry data.

Mocarsky, W.↗

ERTS 1 launch and flight activation evaluation report, 23 - 26 July 1972. Launch through Orbit 35 and orbit adjust operation

The results of the analysis conducted on the telemetry data from the prelaunch, launch, and flight activation phases of the ERTS-1 spacecraft are presented. It is presented by sub system sections and provides for inter-relationships as they exist between the several subsystems. A brief statement of subsystem characteristics precedes flight evaluation statements. The appendix contains a total list of components flow on ERTS-1 and a complete listing of commands and telemetry functions for reference.

Source record↗

An implantable blood pressure and flow transmitter.

A miniature totally implantable FM/FM telemetry system has been developed to simultaneously measure blood pressure and blood flow, thus providing an appreciation of the hemodynamics of the circulation to the entire body or to a particular organ. Developed for work with animal subjects, the telemetry system's transmission time is controlled by an RF signal that permits an operating life of several months. Pressure is detected by a miniature intravascular transducer and flow is detected by an extravascular interferometric ultrasonic technique. Both pressure and flow are calibrated prior to implanting. The pressure calibration can be checked after the implanting by cannulation; flow calibration can be verified only at the end of the experiment by determining the voltage output from the implanted sensing system as a function of several measured flow rates. The utility of this device has been established by its use in investigating canine renal circulation during exercise, emotional encounters, administration of drugs, and application of accelerative forces.

Rader, R. D.↗

Study of magnetic perturbations on SEC vidicon tubes

A laboratory measurements program was conducted to determine the tolerances that must be imposed to achieve optimum performance from SEC-vidicon data sensors in the LST mission. These measurements along with other data were used to formulate recommendations regarding the necessary telemetry and remote control for the television data sensors when in orbit. The study encompassed the following tasks: (1) Conducted laboratory measurements of the perturbations which an external magnetic field produces on a magnetically focused, SEC-vidicon. Evaluated shielding approaches. (2) Experimentally evaluated the effects produced on overall performance by variations of the tube electrode potentials, and the focus, deflection and alignment fields. (3) Recommended the extent of ground control of camera parameters and camera parameter telemetry required for optimizing the performance of the television system in orbit. The experimental data are summarized in a set of graphs.

Long, D. C.↗

Command and data handling for Atmosphere Explorer satellite

The command and data-handling subsystem of the Atmosphere Explorer satellite provides the necessary controls for the instrumentation and telemetry, and also controls the satellite attitude and trajectory. The subsystem executes all command information within the spacecraft, either in real time (as received over the S-band command transmission link) or remote from the command site (as required by the orbit operations schedule). Power consumption in the spacecraft is optimized by suitable application and removal of power to various instruments; additional functions include control of magnetic torquers and of the orbit-adjust propulsion subsystem. Telemetry data from instruments and the spacecraft equipment are formatted into a single serial bit stream. Attention is given to command types, command formats, decoder operation, and command processing functions.

Fuldner, W. V.↗

Potential capabilities for compression of information of certain data processing systems

This article undertakes to study a generalized block diagram of a data collection and processing system of a spacecraft in which a number of sensors or outputs of scientific instruments are cyclically interrogated by a commutator, methods of writing the supplementary information in a frame on the example of a certain hypothetical telemetry system, and the influence of statistics of number of active channels in a frame on frame compression factor. The separation of the data compression factor of the collection and processing system of spacecraft into two parts used in this work allows determination of the compression factor of an active frame depending not only on the statistics of activity of channels in the telemetry frame, but also on the method of introduction of the additional address and time information to each frame.

Khodarev, Y. K.↗

Outer planet Pioneer imaging communications system study

The effects of different types of imaging data compression on the elements of the Pioneer end-to-end data system were studied for three imaging transmission methods. These were: no data compression, moderate data compression, and the advanced imaging communications system. It is concluded that: (1) the value of data compression is inversely related to the downlink telemetry bit rate; (2) the rolling characteristics of the spacecraft limit the selection of data compression ratios; and (3) data compression might be used to perform acceptable outer planet mission at reduced downlink telemetry bit rates.

Source record↗

ERTS 1 flight evaluation report, 23 July 1974 to 23 October 1974

Analyses of ERTS-1 performance during the ninth quarter of its operation are presented. Topics discussed include orbital parameters, power subsystem, attitude control subsystem, command/clock subsystem, telemetry subsystem, orbit adjust subsystem, magnetic moment compensating assembly, unified S band/premodulation processor, electrical interface subsystem, thermal subsystem, narrowband tape recorders, wideband telemetry subsystem, attitude measurement sensor, wideband video tape recorders, return beam vidicon subsystem, multispectral scanner subsystem, and data collection system.

Source record↗

An analysis of spacecraft data time tagging errors

An indepth examination of the timing and telemetry in just one spacecraft points out the genesis of various types of timing errors and serves as a guide in the design of future timing/telemetry systems. The principal sources of timing errors are examined carefully and are described in detail. Estimates of these errors are also made and presented. It is found that the timing errors within the telemetry system are larger than the total timing errors resulting from all other sources.

Fang, A. C.↗