Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Laboratory Testing of the Temperature Sensor Qualification Device

The Temperature sensor Qualification Device (TQD) has been developed and tested under laboratory conditions to evaluate its thermal performance and the reliability of its retractable sensor system. The TQD is designed to provide an isothermal environment for temperature sensors in both test and reference zones during irradiation experiments. Initial testing revealed minimal radial and azimuthal temperature variations but identified a significant axial gradient. To address this, design modifications were implemented, including enhanced insulation and the addition of a small heater at the device's top. These changes are expected to produce a more uniform axial temperature profile, though further testing is recommended prior to irradiation. The retractable sensor mechanism was rigorously tested, achieving 1,350 cycles at room temperature and 332 cycles at 400°C before failure. The primary failure mechanism was the thermocouple becoming stuck in the wire guide or capillary tube. Based on these results, design improvements were proposed, such as incorporating a load cell for force monitoring and a stepper motor for precise sensor positioning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modernizing to an AI-Ready Control System

The Accelerator Controls Operations Research Network (ACORN) project will modernize the accelerator control system and upgrade power supplies to enable future operations of the Fermilab Accelerator Complex with megawatt proton beams. By focusing on MLOps, ACORN enables full integration of AI into the control system to allow safe and reliable improvements to accelerator beam operations.

43 PARTICLE ACCELERATORS↗

Enabling The Next Generation of Smart Sensors in Coal Fired Power Plants using Cellular 5G Technology

Ohio University (OHIO), West Virginia University (WVU), and American Electric Power (AEP) proposed to study and report on the benefits of 5G wireless cellular technologies for coal-fired power plants. The significant advantages, cost savings, and potential of 5G wireless data communications based sensors promised to usher in a new era of reliable, inexpensive, and powerful embedded systems that had not previously been available for coal-fired power plants. The team built upon existing experience with cellular-based systems, power plant water quality sensing, and high temperature sensors developed during past projects. Principal Investigator Wilhelm had been developing cellular-based sensor data systems with a commercial partner for 10 years, pioneering innovative solar-powered devices that began with 2G technology. The lessons and knowledge gained served as a foundation to demonstrate innovations and potential impacts specific to coal fired power plants enabled by 5G technology, along with integration with existing sensors and systems.

20 FOSSIL-FUELED POWER PLANTS↗

ELM 1016706669-AA B581 GDE01 Generator Summary pg 4-5 only

The table below shows the general load breakdown for 581GDE01. Although the total connected load exceeds the generator’s 150kW nameplate capacity, the normal configured load during standby power mode is less, which was measured at 81kW, or 54%, during preventive maintenance activities on 12/12/24. The generator’s available spare capacity must account for dynamically changing loads that can increase the total power demand at any time. If the two online VFD’s are operated at full speed the actual standby mode load is estimated to increase by 38kW, which would bring the total configured load during standby power mode to 119kW, or 79%, still within 581GDE01’s acceptable capacity. Per the LLNL Site 200 Generator Consolidation Final Study 2022, “Standby Emergency Generator nameplate ratings are based upon operation with varying load averaging 70% of the nameplate for 200 hours per year. Continuous loading between 70% and 100% will reduce a generator’s expected lifetime before a major overhaul. This is never a problem with Laboratory machines because of conservative application of generators and the reliability of the normal power system combines to keeps the load and hours down”. To achieve optimal performance and prolong generator life, the recommended generator loading is between 40% and 70%, optimally at 70%, which 581GDE01 appropriately falls within.

42 ENGINEERING↗

Development of A High-Resolution Dataset for Solar Resource Adequacy Studies

High-resolution, long-term solar dataset is essential for characterizing the variability of solar energy resources and for informing strategies that ensure grid reliability and resilience in grid systems with high levels of solar energy integration. We present the development of a new 4-km, hourly Earth system dataset for the contiguous United States (CONUS), using a statistical downscaling approach that integrates the National Solar Radiation Database (NSRDB) with regional Earth system model projections. The new high-resolution Earth system dataset includes key variables - GHI, DNI, DHI, surface air temperature, and wind speed - under two future scenarios. Preliminary results show a reasonable agreement with NSRDB observations, with nBias less than 1% for GHI across CONUS. The dataset is expected to support in-depth analyses of extreme weather impacts and provide input to resource adequacy for future energy systems with diverse generation sources.

14 SOLAR ENERGY↗

Distribution System Plan Template and Guide for Electric Utilities for Adaptation by States and Utilities [Slides]

LBNL researchers developed a template and companion guide for structuring distribution system plans. The template covers 10 key sections in utility distribution system plans and underlying topics: -Executive Summary -Planning Objectives -Current Distribution System -Planning Approach -Asst Management, Reliability and Resilience -O&M Expenses -Capacity Expansion Planning -Solution Identification -Cost-effectiveness -Implementation For each section in the template, the companion guide provides: a description of the topics covered and their importance; the type of content to include in the plan; an example utility approach; and references to other utility plans that serve as models for the topic.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing a Vorticity-Velocity-Based Off-Body Solver to Perform Multifidelity Simulations of Wind Farms

Wind power has become a key player in satisfying the global energy needs. With increased market penetration, unanticipated unsteady loading induced failures, installation related reductions in power generation, and significant maintenance costs have underscored the need to predict the unsteady fluid-structure interactions related to turbine layout and off-design wind conditions. Contemporary turbine design tools are incapable of accounting for such loadings. As a result, researchers have started utilizing high-Performance-Computing (HPC) based Computational Fluid Dynamics (CFD) solvers, such as the U.S. Department of Energy sponsored ExaWind software package, to investigate these phenomena. Unfortunately, such HPC tools are computationally expensive for routine industrial use, often because of the sheer number of cells required to resolve the wake flowfield. This paper describes a preliminary effort to address this issue by developing a vorticity-velocity based CFD off-body solver, VorTran-M2-AMReX, that integrates directly with DOE's ExaWind wind turbine analysis system to perform accurate and reliable simulations of wind turbine/farm at a lower computational cost than ExaWind alone. This article summarizes work undertaken to date concerning the assembly of the proposed analysis tool, and provides preliminary validation and verification of the VorTran-M2-AMReX off-body solver.

adaptive mesh refinement↗

In-Home Mobility Frequency and Stability in Older Adults Living Alone With or Without MCI: Introduction of New Metrics

Background: Older adults spend a considerable amount of time inside their residences; however, most research investigates out-of-home mobility and its health correlates. We measured indoor mobility using room-to-room transitions, tested their psychometric properties, and correlated indoor mobility with cognitive and functional status. Materials and Methods: Community-dwelling older adults living alone ( n = 139; age = 78.1 ± 8.6 years) from the Oregon Center for Aging & Technology (ORCATECH) and Minority Aging Research Study (MARS) were included in the study. Two indoor mobility features were developed using non-parametric parameters (frequency; stability): Indoor mobility frequency (room-to-room transitions/day) was detected using passive infrared (PIR) motion sensors fixed on the walls in four geographic locations (bathroom; bedroom; kitchen; living room) and using door contact sensors attached to the egress door in the entrance. Indoor mobility stability was estimated by variances of number of room-to-room transitions over a week. Test-retest reliability (Intra-class coefficient, ICC) and the minimal clinically important difference (MCID) defined as the standard error of measurement (SEM) were generated. Generalized estimating equations models related mobility features with mild cognitive impairment (MCI) and functional status (gait speed). Results: An average of 206 days (±127) of sensor data were analyzed per individual. Indoor mobility frequency and stability showed good to excellent test-retest reliability (ICCs = 0.91[0.88–0.94]; 0.59[0.48–0.70]). The MCIDs of mobility frequency and mobility stability were 18 and 0.09, respectively. On average, a higher indoor mobility frequency was associated with faster gait speed (β = 0.53, p = 0.04), suggesting an increase of 5.3 room-to-room transitions per day was associated with an increase of 10 cm/s gait speed. A decrease in mobility stability was associated with MCI (β = −0.04, p = 0.03). Discussion: Mobility frequency and stability in the home are clinically meaningful and reliable features. Pervasive-sensing systems deployed in homes can objectively reveal cognitive and functional status in older adults who live alone.

Wu, Chao-Yi↗

Knowing the unknown: The underestimation of monkeypox cases. Insights and implications from an integrative review of the literature

Monkeypox is an emerging zoonotic disease caused by the monkeypox virus, which is an infectious agent belonging to the genus Orthopoxvirus. Currently, commencing from the end of April 2022, an outbreak of monkeypox is ongoing, with more than 43,000 cases reported as of 23 August 2022, involving 99 countries and territories across all the six World Health Organization (WHO) regions. On 23 July 2022, the Director-General of the WHO declared monkeypox a global public health emergency of international concern (PHEIC), since the outbreak represents an extraordinary, unusual, and unexpected event that poses a significant risk for international spread, requiring an immediate, coordinated international response. However, the real magnitude of the burden of disease could be masked by failures in ascertainment and under-detection. As such, underestimation affects the efficiency and reliability of surveillance and notification systems and compromises the possibility of making informed and evidence-based policy decisions in terms of the adoption and implementation of ad hoc adequate preventive measures. In this review, synthesizing 53 papers, we summarize the determinants of the underestimation of sexually transmitted diseases, in general, and, in particular, monkeypox, in terms of all their various components and dimensions (under-ascertainment, underreporting, under-detection, under-diagnosis, misdiagnosis/misclassification, and under-notification).

59 BASIC BIOLOGICAL SCIENCES↗

Performance of DSRC V2V Communication Networks in an Autonomous Semi-Truck Platoon Application

Autonomy for multiple trucks to drive in a fixedheadway platoon formation is achieved by adding precision GPS and V2V communications to a conventional adaptive cruise control (ACC) system. The performance of the Cooperative ACC (CACC) system depends heavily on the reliability of the underlying V2V communications network. Using data recorded on precision-instrumented trucks at both ACM and NCAT test tracks, we provide an understanding of various effects on V2V network performance: Occlusions - non-line-of-sight (NLOS) between the Tx and Rx antenna may cause network signal loss. Rain - water droplets in the air may cause network signal degradation. Antenna position - antennas at higher elevation may have less ground clutter to deal with. RF interference - interference may cause network packet loss. GPS outage - outages caused by tree cover, tunnels, etc. may result in degraded performance. Road curvature - curves may affect antenna diversity. Road grade - antenna may have limited vertical coverage. Our results, which include multiple plots and graphs and their analysis, build on those reported by others and could be of interest to researchers, practitioners, and end-users in the broader autonomous-connected vehicle community.

V2V communications, GPS, truck platoon, semi-auton↗

Observations of PV Systems Post-Hurricane

NREL's observations of post-hurricane photovoltaic (PV) systems were shared with PV reliability researchers during the Photovoltaic Reliability Workshop held in Lakewood, Colorado the week of February 26, 2018. NREL hosts an annual Photovoltaic Reliability Workshop (PVRW) so that solar technology experts can share information leading to the improvement of PV module reliability. Such improvement reduces the cost of solar electricity and promotes investor confidence in the technology - both critical goals for moving PV technologies deeper into the electricity marketplace. This presentation is intended to share real world examples of PV survivability during and after Hurricanes Irma and Maria in 2017.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Smart Ventilation Controls Boost Energy Efficiency and Indoor Air Quality

The average American household spends more than $2,200 a year on energy, and heating, ventilating, and air conditioning (HVAC) costs comprise nearly half of the bill. This is one reason why home builders focus on tightening building envelopes to save energy. Yet, limiting the potential for air exchange can negatively impact indoor air quality (IAQ). When outdoor conditions are most extreme during occupied periods, there may be comfort implications from continuing high levels of ventilation during associated weather events. This is true even with heat recovery. To mitigate risks, the Florida Solar Energy Center developed and tested approaches for “smart” ventilation system controls that enable more reliable design, installation, and operation to achieve desired IAQ while also minimizing energy and comfort impacts.

Building America↗

Smart Ventilation Controls Boost Energy Efficiency and Indoor Air Quality

The average American household spends more than $2,200 a year on energy, and heating, ventilating, and air conditioning (HVAC) costs comprise nearly half of the bill. This is one reason why home builders focus on tightening building envelopes to save energy. Yet, limiting the potential for air exchange can negatively impact indoor air quality (IAQ). When outdoor conditions are most extreme during occupied periods, there may be comfort implications from continuing high levels of ventilation during associated weather events. This is true even with heat recovery. To mitigate risks, the Florida Solar Energy Center developed and tested approaches for “smart” ventilation system controls that enable more reliable design, installation, and operation to achieve desired IAQ while also minimizing energy and comfort impacts.

30 DIRECT ENERGY CONVERSION↗

Online Event Detection in Synchrophasor Data with Graph Signal Processing

Online detection of anomalies is crucial to enhancing the reliability and resiliency of power systems. We propose a novel data-driven online event detection algorithm with synchrophasor data using graph signal processing. In addition to being extremely scalable, our proposed algorithm can accurately capture and leverage the spatio-temporal correlations of the streaming PMU data. This paper also develops a general technique to decouple spatial and temporal correlations in multiple time series. Finally, we develop a unique framework to construct a weighted adjacency matrix and graph Laplacian for product graph. Case studies with real-world, large-scale synchrophasor data demonstrate the scalability and accuracy of our proposed event detection algorithm. Compared to the state-of-the-art benchmark, the proposed method not only achieves higher detection accuracy but also yields higher computational efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Absorbing the Sun: Operational Practices and Balancing Reserves in Florida's Municipal Utilities

The Florida Reliability Coordinating Council (FRCC) power system is comprised of multiple balancing authorities ranging in size from Gainesville Regional Utilities (GRU) with a 2019 summer net firm demand of 429 MW to Florida Power & Light with a 2019 summer net firm demand of 22,510 MW; and including cooperative, municipal, and investor-owned utilities. As all of these balancing authorities are and have plants to continue installing significant quantities of utility-scale solar photovoltaics, one relevant question is how much operating reserves they will need to hold as solar penetrations increase. While there are estimates of how regulating and flexibility reserve requirements change with solar penetration, the literature almost exclusively focuses on large balancing authorities with sub-hourly dispatch. In this work we analyze how reserve needs change not only with solar photovoltaic penetration, but also balancing authority size and operational practices. We find that, measured as a fraction of load, smaller balancing authorities with less frequent load and solar forecasts and less frequent dispatch need more reserves. Such utilities' reserve needs also increase more with increasing solar deployment as compared to larger or more frequently dispatched balancing authorities. These impacts are most acute for GRU. We find that moving from day-ahead to hour-ahead load and solar forecasting and system dispatch could enable GRU to incorporate 32% solar generation with median reserves at 20% instead of 60% of load; and that median reserve needs could drop further to about 10% of load if Florida's municipal utilities formed a reserve sharing group and moved to sub-hourly dispatch.

balancing authority↗

Smart Methane Emission Detection System Development (Final Report)

Working with the Department of Energy’s National Energy Technology Laboratory, Southwest Research Institute® (SwRI®) developed a system to identify methane leaks reliably, accurately, and autonomously at critical midstream sections of the natural gas distribution network in real- time for the purpose of mitigating methane emissions using Optical Gas Imaging (OGI) cameras. SwRI’s Smart Leak Detection – Methane (SLED/M) adds a high degree of automation to the process of methane leak detection to minimize sources of human error, minimize response time to a leak event, and maximize midstream visibility. Furthermore, SwRI has been working towards integrating Quantitative OGI (QOGI) capabilities into this existing technology. By leveraging Deep Learning, SwRI now has the capability to estimate fugitive emission leak rates quickly and reliably, which allows operators to detect emissions, quantify leak rate, prioritize repairs, and validate the repairs in a single instrument. The next generation QOGI technology leverages the same cameras used in Leak Detection and Repair (LDAR) programs, with improvements in safety and speed for traditional quantification-based repairs, ultimately leading to less overhead cost for the operators. The goals for this research were to develop two types of models with the following goals: 1. Run in real-time on the edge (≥ 12 Hz) 2. Classification: Achieve less than 5% false positive detection 3. Classification: Achieve ≥ 95% methane plume detection rate 4. Regression: achieve ≤ 10 standard cubic feet per hour (scfh) prediction > 70% of the time In order to achieve these results, multiple infrared (IR) and other sensors were investigated in tandem with the midwave IR (MWIR) OGI to provide additional information to train the underlying models. Information on atmospheric conditions including humidity, temperature, pressure, and solar radiation was provided by a weather station. Several machine learning and deep learning architectures and methods, including looking at quantized classification networks and regressions networks, were explored. As further data was collected, curated, and labeled, it allowed for more refined regressive networks to be adequately trained, leading to better insight into the true flow rates being observed. An important valuable deliverable of this research effort was the development of an advanced network which underwent multiple iterations capable of giving a continuous output. The current network has a predicted mean average percentage error (MAPE) of 12.3% just outside our target goal of 10.00%, but an accuracy of 97.78% at ±50 scfh, well within the overall goal for the Department of Energy (DOE) program. Upon closer inspection, it was observed that more than 10% of datapoints contributing to the MAPE predictions were the result of low flow rate predictions and are beyond the sensitivity of instrument measurement as a result of normal operational variation and noise.

03 NATURAL GAS↗

Wind Energy Accomplishments & Midyear Performance Report: Fiscal Year 2022

2022 marks 43 years of innovation through the National Wind Technology Center at the U.S. Department of Energy's (DOE's) National Renewable Energy Laboratory (NREL) Flatirons Campus. Scientists, engineers, analysts, and researchers continue to build on NREL's legacy of innovation at this world-class hub for wind energy technology research and development. Today, the nation's goals to tackle climate change and revitalize the U.S. economy through increased investment in clean energy - particularly in land-based, offshore, and distributed wind energy - are more ambitious than ever. From advancing wind energy science, technologies, and materials to demonstrating thought leadership on a worldwide scale, NREL's Wind Energy Program played a powerful role in maximizing the impact of wind energy in the first half of Fiscal Year (FY) 2022. NREL's technical expertise, research capabilities, and industry understanding continued to support DOE's efforts to champion clean energy, addressing market and deployment barriers and driving down costs with more efficient, reliable, and predictable wind energy systems. This report provides an overview of the achievements NREL made on behalf of DOE's Wind Energy Technologies Office (WETO) and other partners between October 1, 2021, and March 31, 2022.

accomplishments↗

Modernizing the SNS Control System

The Spallation Neutron Source at Oak Ridge National Laboratory has been operating since 2006. An upgrade to double the machine power from 1.4 MW to 2.8 MW is currently underway and a project to add a second target station is in the preliminary design phase. While each project will add the controls needed for their specific scope, the existing control system hardware, software, and infrastructure require upgrades to maintain high availability and ensure the system will meet facility requirements into the future. While some systems have received new hardware due to obsolescence, much of the system is original apart from some maintenance and technology refresh. Software will also become obsolete and must be upgraded for sustainability. Further, requirements for system capacity can be expected to increase as more subsystems upgrade to smarter devices capable of higher data rates. This paper covers planned improvements to the integrated control system with a focus on reliability, sustainability, and future capability.

White, Karen S.↗