Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “static test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Flight service evaluation of composite helicopter components

An assessment is presented of ten composite tail rotor spars and four horizontal stabilizers exposed to the effects of in-flight commercial service for up to nine years to establish realistic environmental factors for use in future designs. This evaluation is supported by test results of helicopter components and panels which have been exposed to outdoor environmental effects since 1979. Full scale static and fatigue tests were conducted on graphite/epoxy and Kevlar/epoxy composite components removed from Sikorsky Model S-76 helicopters in commercial operations off the Gulf Coast of Louisiana. Small scale static and fatigue tests were conducted on coupons obtained from panels exposed to outdoor conditions in Stratford, CT and West Palm Beach, Florida. The panel materials and ply configurations were representative of the S-76 components. The results are discussed of moisture analyses and strength tests on both the S-76 components and composite panels after up to nine years of outdoor exposure. Full scale tests performed on the helicopter components did not disclose any significant reductions from the baseline strengths. The results increased confidence in the long term durability of advanced composite materials in helicopter structural applications.

Mardoian, George H.↗

Development and correlation: Viking Orbiter analytical dynamic model with modal test

The Viking Orbiter (VO) experience in the achievement of a mathematical model is described along with the following project activities: (1) the generation of the overall plan for load analysis, an analytical dynamic model, and development tests; (2) the performance of VO subsystem static and modal tests; and (3) the correlation of the VO system model analysis and test. Success is attributed to the coordination of analysis and test using substructure modal coupling techniques.

Wada, B. K.↗

Outer planet probe engineering model structural tests

A series of proof of concept structural tests was performed on an engineering model of the Outer Planets Atmospheric Entry Probe. The tests consisted of pyrotechnic shock, dynamic and static loadings. The tests partially verified the structural concept.

Smittkamp, J. A.↗

DC Magnetics Measurement System Design

This report will detail the updates to the magnetics measurement system design and testing procedures that are required for performing static (DC) magnetics testing of future flight hardware. An older magnetics testing system had to be integrated with new procedures and hardware to meet the demands of future testing programs and accommodate an upcoming magnetics tests. The next test will be for the Geostationary Operational Environmental Satellite R-Series (GOES-R), which will verify that the SAFT Battery component meets its specifications for magnetic cleanliness. The satellite is scheduled to launch in 2015 with magnetics testing to be completed on the battery in November 2012.

DC magnetics↗

Flight service evaluation of composite helicopter components

This report presents an assessment of composite helicopter tail rotor spars and horizontal stabilizers, exposed to the effects of the environment, after up to five and a half years of commercial service. This evaluation is supported by test results of helicopter components and panels which have been exposed to outdoor environmental effects since September 1979. Full scale static and fatigue tests have been conducted on graphite/epoxy and Kevlar/epoxy composite components obtained from Sikorsky Model S-76 helicopters in commercial operations in the Gulf Coast region of Louisiana. Small scale static and fatigue tests are being conducted on coupons obtained from panels under exposure to outdoor conditions in Stratford, Connecticut and West Palm, Florida. The panel layups are representative of the S-76 components. Additionally, this report discusses the results of moisture absorption evaluations and strength tests on the S-76 components and composite panels with up to five years of outdoor exposure.

Mardoian, G. H.↗

Potential utilization of the NASA/George C. Marshall Space Flight Center in earthquake engineering research

Earthquake engineering research capabilities of the National Aeronautics and Space Administration (NASA) facilities at George C. Marshall Space Flight Center (MSFC), Alabama, were evaluated. The results indicate that the NASA/MSFC facilities and supporting capabilities offer unique opportunities for conducting earthquake engineering research. Specific features that are particularly attractive for large scale static and dynamic testing of natural and man-made structures include the following: large physical dimensions of buildings and test bays; high loading capacity; wide range and large number of test equipment and instrumentation devices; multichannel data acquisition and processing systems; technical expertise for conducting large-scale static and dynamic testing; sophisticated techniques for systems dynamics analysis, simulation, and control; and capability for managing large-size and technologically complex programs. Potential uses of the facilities for near and long term test programs to supplement current earthquake research activities are suggested.

Scholl, R. E.↗

Effect of Ratio of Jet Area to Total Area and of Pressure Ratio on Lift Augmentation of Annular Jets in Ground Effect Under Static Conditions

The present investigation was undertaken to determine the effects of the ratio of jet area to total area and of the pressure ratio on the lift-augmentation characteristics of annular jets in ground effect. The investigation was made over an area-ratio range of 1.00 to 0.02 and a pressure-ratio range of about 1.04 to 1.95. Several configurations with center jets were tested through an angle-of-attack range to determine the pitching-moment characteristics. The tests were conducted in a static test room with the use of the compressed-air facilities. The results show that lift augmentation increases somewhat as the area ratio is reduced to about 0.10, below which it deteriorates due to thin jet mixing. The effect of pressure ratio on lift was negligible for the area-ratio range investigated. Calculations of the lift per air horsepower for a given base loading indicate that the greatest lift per air horsepower occurs at area ratios above 0.10, where the greatest lift augmentation occurs. The data show that annular-Jet vehicles are unstable at ratios of height above ground to nozzle diameter above about 0.10. The stability of the annular-jet vehicle can be improved by the use of large center jets. Base compartments also reduces the unstable moment.

Goodson, Kenneth W.↗

Fluid mechanics of dynamic stall. II - Prediction of full scale characteristics

Analytical extrapolations are made from experimental subscale dynamics to predict full scale characteristics of dynamic stall. The method proceeds by establishing analytic relationships between dynamic and static aerodynamic characteristics induced by viscous flow effects. The method is then validated by predicting dynamic test results on the basis of corresponding static test data obtained at the same subscale flow conditions, and the effect of Reynolds number on the static aerodynamic characteristics are determined from subscale to full scale flow conditions.

Ericsson, L. E.↗

Investigation of the oxidation behavior of dispersion stabilized alloys when exposed to a dynamic high temperature environment

The oxidation behavior of TD-NiCr and TD-NiCrAlY alloys have been studied at 2000 and 2200 F in static and high speed flowing air environments. The TD-NiCrAlY alloys preoxidized to produce an Al2O3 scale on the surface showed good oxidation resistance in both types of environments. The TD-NiCr alloy which had a Cr2O3 oxide scale after preoxidation was found to oxidize more than an order of magnitude faster under the dynamic test conditions than at comparable static test conditions. Although Cr2O3 normally provides good oxidation protection, it was rapidly lost due to formation of volatile CrO3 when exposed to the high speed air stream. The preferred oxide arrangement for the dynamic test consisted of an external layer of NiO with a porous mushroom type morphology, an intermediate duplex layer of NiO and Cr2O3, and a continuous inner layer of Cr2O3 in contact with the alloy substrate. An oxidation model has been developed to explain the observed microstructure and overall oxidation behavior of all alloys.

Tenney, D. R.↗

Mixed-mode strain-energy-release rate effects on edge delamination of composites

Unnotched graphite/epoxy laminates, designed to delaminate at the edges under static and cyclic tensile loads, were tested and analyzed. The specimen stacking sequences were chosen so that the total strain-energy-release rate, G, for edge delamination was identical for all three layups. However, each layup had different percentages of crack-opening and shear-mode strain-energy-release rates, G sub 1 and G sub 2, respectively. Results with composites made from T300 graphite fibers and 5208 epoxy, a brittle resin, indicated that only G sub 1 contributed to delamination onset under static loading. However, results with composites made from C6000 fibers and H205 epoxy, a tougher resin, indicated that the total F governed the onset of edge delaminations under cyclic loads. In addition, for both materials, the threshold level of G for delamination onset in fatigue was significantly less than the critical G sub c measured in static tests. Futhermore, although the C6000/H205 material had a much higher static G sub c than T300/5208, its fatigue resistance was only slightly better. A series of mixed-mode tests, like the ones in this study, may be needed to evaluate toughened-resin composites developed for highly strained composite structures subjected to cyclic loads.

Obrien, T. K.↗

Overview of the Water-Based RIA Testing in TREAT

A series of reactivity-initiated accident (RIA) commissioning tests have been completed with the static water capsule in the Transient Reactor Test (TREAT) Facility. The test campaign included a calibration test followed by five tests in the Static Environment Rodlet Transient Test Apparatus (SERTTA) capsule. The conditions varied from room temperature and pressure up to 200°C and 2.5 MPa with energy depositions varying between ~500-1100 J/gUO2. The series of tests allowed for a number of instrumentation qualifications and demonstrations including cladding thermometry, rodlet plenum pressure, cladding elongation, and an electro-impedance boiling detector. This paper documents the design of the capsule and highlight the results from the commissioning tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Indentation-flexure and low-velocity impact damage in graphite epoxy laminates

Static indentation-flexure and low-velocity impact tests were performed on quasi-isotropic and cross-ply graphite/epoxy composite laminates. The load-deflection relations in static tests and impact force history in impact tests were recorded. The damage was assessed by using ultrasonic C-scanning and photo-micrographic techniques. Some features of the static behavior were explained by simple analytical models. A good correlation existed between the load-deflection curves for static and impact loading. It was found that results from a few static indentation-flexure tests can be used to predict the impact force history and delamination radius in composite laminates due to low-velocity impact.

Kwon, Young S.↗

Low speed wind tunnel test of ground proximity and deck edge effects on a lift cruise fan V/STOL configuration, volume 1

The characteristics were determined of a lift cruise fan V/STOL multi-mission configuration in the near proximity to the edge of a small flat surface representation of a ship deck. Tests were conducted at both static and forward speed test conditions. The model (0.12 scale) tested was a four fan configuration with modifications to represent a three fan configuration. Analysis of data showed that the deck edge effects were in general less critical in terms of differences from free air than a full deck (in ground effect) configuration. The one exception to this was when the aft edge of the deck was located under the center of gravity. This condition, representative of an approach from the rear, showed a significant lift loss. Induced moments were generally small compared to the single axis control power requirements, but will likely add to the pilot work load.

Stewart, V. R.↗

Experimental investigation of passive infrared ice detection for helicopter applications

A technique is proposed to remotely detect rotor icing on helicopters. Using passive infrared (IR) thermometry it is possible to detect the warming caused by latent heat released as supercooled water freezes. During icing, the ice accretion region on the blade leading edge will be warmer than the uniced trailing edge resulting in a chordwise temperature profile characteristic of icing. Preliminary tests were conducted on a static model in the NASA Icing Research Tunnel for a variety of wet (glaze) and dry (rime) ice conditions. The characteristic chordwise temperature profiles were observed with an IR thermal video system and confirmed with thermocouple measurements. A prototype detector system was built consisting of a single point IR pyrometer, and experiments were run on a small scale rotor model. Again the characteristic chordwise temperature profiles were observed during icing, and the IR system was able to remotely detect icing. Based on the static and subscale rotor tests the passive IR technique is promising for rotor ice detection.

Dershowitz, Adam↗

Experimental investigation of passive infrared ice detection for helicopter applications

A technique is proposed to remotely detect rotor icing on helicopters. Using passive infrared (IR) thermometry, it is possible to detect the warming caused by latent heat released as supercooled water freezes. During icing, the ice accretion region on the blade leading edge will be warmer than the uniced trailing edge, resulting in a chordwise temperature profile characteristic of icing. Preliminary tests were conducted on a static model in the NASA Icing Research Tunnel for a variety of wet (glaze) and dry (rime) ice conditions. The characteristic chordwise temperature profiles were observed with an IR thermal video system and confirmed with thermocouple measurements. A prototype detector system was built consisting of a single point IR pyrometer. Experiments were run on a small scale rotor model. Again, the characteristic chordwise temperature profiles were observed during icing, and the IR system was able to remotely detect icing. Based on the static and subscale rotor tests, the passive IR technique is promising for rotor ice detection.

Dershowitz, Adam↗

Emergency vehicle alert system, phase 2

The EVAS provides warning for hearing-impaired motor vehicle drivers that an emergency vehicle is in the local vicinity. Direction and distance to the emergency vehicle are presented visually to the driver. This is accomplished by a special RF transmission/reception system. During this phase the receiver and transmitter from Phase 1 were updated and modified and a directional antenna developed. The system was then field tested with good results. Static and dynamic (moving vehicle) tests were made with the direction determined correctly 98 percent of the time.

Barr, Tom↗

Aerodynamic and acoustic behavior of a YF-12 inlet at static conditions

An aeroacoustic test program was performed with a YF-12 aircraft at ground static conditions. The objective was to collect acoustic and aerodynamic data that could determine the cause of YF-12 inlet noise suppression observed earlier. The results showed that the far-field noise level was lower with the YF-12 inlet than with a bellmouth inlet at engine speeds above 5500 rpm. The differences were about 5 PNdB to 11 PNdB, depending on YF-12 inlet configuration and on engine speed. Measurements showed that YF-12 inlet noise suppression was not caused by flow choking. The spike support struts were probably responsible, as in that region the spectral peak near the blade passing frequency disappeared between 6000 and 6600 rpm, and multiple pure tones were greatly reduced.

Bangert, L. H.↗