Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software estimations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Effect of temporal averaging of meteorological data on predictions of groundwater recharge

Accurate estimates of infiltration and groundwater recharge are critical for many hydrologic, agricultural and environmental applications. Anticipated climate change in many regions of the world, especially in tropical areas, is expected to increase the frequency of high-intensity, short-duration precipitation events, which in turn will affect the groundwater recharge rate. Estimates of recharge are often obtained using monthly or even annually averaged meteorological time series data. In this study we employed the HYDRUS-1D software package to assess the sensitivity of groundwater recharge calculations to using meteorological time series of different temporal resolutions (i.e., hourly, daily, weekly, monthly and yearly averaged precipitation and potential evaporation rates). Calculations were applied to three sites in Brazil having different climatological conditions: a tropical savanna (the Cerrado), a humid subtropical area (the temperate southern part of Brazil), and a very wet tropical area (Amazonia). To simplify our current analysis, we did not consider any land use effects by ignoring root water uptake. Temporal averaging of meteorological data was found to lead to significant bias in predictions of groundwater recharge, with much greater estimated recharge rates in case of very uneven temporal rainfall distributions during the year involving distinct wet and dry seasons. For example, at the Cerrado site, using daily averaged data produced recharge rates of up to 9 times greater than using yearly averaged data. In all cases, an increase in the time of averaging of meteorological data led to lower estimates of groundwater recharge, especially at sites having coarse-textured soils. Lastly, our results show that temporal averaging limits the ability of simulations to predict deep penetration of moisture in response to precipitation, so that water remains in the upper part of the vadose zone subject to upward flow and evaporation.

54 ENVIRONMENTAL SCIENCES↗

Experiments in software reliability - Life-critical applications

The paper discusses four reliability data gathering experiments which were conducted using a small sample of programs for two problems having ultrareliability requirements, n-version programming for fault detection, and repetitive run modeling for failure and fault rate estimation. The experimental results agree with those of Nagel and Skrivan in that the program error rates suggest an approximate log-linear pattern and the individual faults occurred with significantly different error rates. Additional analysis of the experimental data raises new questions concerning the phenomenon of interacting faults. This phenomenon may provide one explanation for software reliability decay. The fourth experiment underscored the difficulty in distinguishing between observations of deficiencies in the design of the algorithm and observations of software faults for real-time process control software. These experiments are a part of a program of serial experiments being pursued by the System Validation Methods of NASA-Langley Research Center to find a means of credibly performing reliability evaluations of flight control software.

Dunham, J. R.↗

Bayesian Estimation of Oscillator Parameters: Toward Anomaly Detection and Cyber-Physical System Security

Cyber-physical system security presents unique challenges to conventional measurement science and technology. Anomaly detection in software-assisted physical systems, such as those employed in additive manufacturing or in DNA synthesis, is often hampered by the limited available parameter space of the underlying mechanism that is transducing the anomaly. As a result, the formulation of anomaly detection for such systems often leads to inverse or ill-posed problems, requiring statistical treatments. Here, we present Bayesian inference of unknown parameters associated with a generic actuator considered as a representative vital element of a cyber-physical system. Via a series of experimental input-output measurements, a transfer function for the actuator is obtained numerically, which serves as our model for the proposed method. Linear, nonlinear, and delayed dynamics may be assumed for the actuator response. By devising a code-based malicious signal, we study the efficacy of Bayesian inference for its potential to produce a detection, including uncertainty quantification, with a remarkably small number of input data points. Our approach should be adaptable to a variety of real-time cyber-physical anomaly detection scenarios.

47 OTHER INSTRUMENTATION↗

SU-D-17A-07: Development and Evaluation of a Prototype Ultrasonography Respiratory Monitoring System for 4DCT Reconstruction

Purpose: Respiratory motion artifacts are commonly seen in the abdominal and thoracic CT images. A Real-time Position Management (RPM) system is integrated with CT simulator using abdominal surface as a surrogate for tracking the patient respiratory motion. The respiratory-correlated four-dimensional computed tomography (4DCT) is then reconstructed by GE advantage software. However, there are still artifacts due to inaccurate respiratory motion detecting and sorting methods. We developed an Ultrasonography Respiration Monitoring (URM) system which can directly monitor diaphragm motion to detect respiratory cycles. We also developed a new 4DCT sorting and motion estimation method to reduce the respiratory motion artifacts. The new 4DCT system was compared with RPM and the GE 4DCT system. Methods: Imaging from a GE CT scanner was simultaneously correlated with both the RPM and URM to detect respiratory motion. A radiation detector, Blackcat GM-10, recorded the X-ray on/off and synchronized with URM. The diaphragm images were acquired with Ultrasonix RP system. The respiratory wave was derived from diaphragm images and synchronized with CT scanner. A more precise peaks and valleys detection tool was developed and compared with RPM. The motion is estimated for the slices which are not in the predefined respiratory phases by using block matching and optical flow method. The CT slices were then sorted into different phases and reconstructed, compared with the images reconstructed from GE Advantage software using respiratory wave produced from RPM system. Results: The 4DCT images were reconstructed for eight patients. The discontinuity at the diaphragm level due to an inaccurate identification of phases by the RPM was significantly improved by URM system. Conclusion: Our URM 4DCT system was evaluated and compared with RPM and GE 4DCT system. The new system is user friendly and able to reduce motion artifacts. It also has the potential to monitor organ motion during therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

GridOPTICS/GridPACK

GridPACK is a software framework consisting of a set of modules designed to simplify the development of programs that model the power grid and run on parallel, high performance computing platforms. It also contains several fully developed applications, including powerflow, dynamic simulation, state estimation, Kalman filter analysis (dynamic state estimation), contingency analysis and real time path rating. These applications can be used either standalone or as components in more complicated workflows that combine several different types of application together. The framework modules are available as a combination of libraries and software templates and consist of components for setting up and distributing power grid networks, support for modeling the behavior of individual buses and branches in the network, converting the network models to the corresponding algebraic equations, and parallel routines for manipulating and solving large algebraic systems. The framework also contains a module for distributing tasks evenly amongst computing resources, even if individual tasks vary widely in their execution times. Additional modules support input and output, basic statistical analysis of contingency based calculations, distributed data structures, as well as basic profiling and error management.

Palmer, Bruce↗

Regional Economic Accounting (REAcct): A Software Tool for Rapidly Approximating Economic Impacts

This paper describes the Regional Economic Accounting (REAcct) analysis tool that has been in use for the last 5 years to rapidly estimate approximate economic impacts for disruptions due to natural or manmade events. It is based on and derived from the well-known and extensively documented input-output modeling technique initially presented by Leontief and more recently further developed by numerous contributors. REAcct provides county-level economic impact estimates in terms of gross domestic product (GDP) and employment for any area in the United States. The process for using REAcct incorporates geospatial computational tools and site-specific economic data, permitting the identification of geographic impact zones that allow differential magnitude and duration estimates to be specified for regions affected by a simulated or actual event. Using these data as input to REAcct, the number of employees for 39 directly affected economic sectors (including 37 industry production sectors and 2 government sectors) are calculated and aggregated to provide direct impact estimates. Indirect estimates are then calculated using Regional Input-Output Modeling System (RIMS II) multipliers. The interdependent relationships between critical infrastructures, industries, and markets are captured by the relationships embedded in the inputoutput modeling structure.

97 MATHEMATICS AND COMPUTING↗

Stochastic Modeling of Radioactive Material Releases

Nonreactor nuclear facilities operated under the approval authority of the U.S. Department of Energy use unmitigated hazard evaluations to determine if potential radiological doses associated with design basis events challenge or exceed dose evaluation guidelines. Unmitigated design basis events that sufficiently challenge dose evaluation guidelines or exceed the guidelines for members of the public or workers, merit selection of safety structures, systems, or components or other controls to prevent or mitigate the hazard. Idaho State University, in collaboration with Idaho National Laboratory, has developed a portable and simple to use software application called SODA (Stochastic Objective Decision-Aide) that stochastically calculates the radiation dose associated with hypothetical radiological material release scenarios. Rather than producing a point estimate of the dose, SODA produces a dose distribution result to allow a deeper understanding of the dose potential. SODA allows users to select the distribution type and parameter values for all of the input variables used to perform the dose calculation. SODA then randomly samples each distribution input variable and calculates the overall resulting dose distribution. In cases where an input variable distribution is unknown, a traditional single point value can be used. SODA was developed using the MATLAB coding framework. The software application has a graphical user input. SODA can be installed on both Windows and Mac computers and does not require MATLAB to function. SODA provides improved risk understanding leading to better informed decision making associated with establishing nuclear facility material-at-risk limits and safety structure, system, or component selection. It is important to note that SODA does not replace or compete with codes such as MACCS or RSAC, rather it is viewed as an easy to use supplemental tool to help improve risk understanding and support better informed decisions. The work was funded through a grant from the DOE Nuclear Safety Research and Development Program.

61 RADIATION PROTECTION AND DOSIMETRY↗

Use of Dual Frequency Identification Sonar to Determine Adult Chinook Salmon (Oncorhynchus tshawytscha) Escapement in the Secesh River, Idaho ; Annual Report, January 2008 – December 2008.

Chinook salmon in the Snake River basin were listed as threatened under the Endangered Species Act in 1992 (NMFS 1992). The Secesh River represents the only stream in the Snake River basin where natural origin (wild) salmon escapement monitoring occurs at the population level, absent a supplementation program. As such the Secesh River has been identified as a long term salmon escapement and productivity monitoring site by the Nez Perce Tribe Department of Fisheries Resources Management. Salmon managers will use this data for effective population management and evaluation of the effect of conservation actions on a natural origin salmon population. The Secesh River also acts as a reference stream for supplementation program comparison. Dual frequency identification sonar (DIDSON) was used to determine adult spring and summer Chinook salmon escapement in the Secesh River in 2008. DIDSON technology was selected because it provided a non-invasive method for escapement monitoring that avoided listed species trapping and handling incidental mortality, and fish impedance related concerns. The DIDSON monitoring site was operated continuously from June 13 to September 14. The first salmon passage was observed on July 3. DIDSON site total estimated salmon escapement, natural and hatchery fish, was 888 fish {+-} 65 fish (95% confidence interval). Coefficient of variation associated with the escapement estimate was 3.7%. The DIDSON unit was operational 98.1% of the salmon migration period. Adult salmon migration timing in the Secesh River occurred over 74 days from July 3 to September 14, with 5,262 total fish passages observed. The spawning migration had 10%, median, and 90% passage dates of July 8, July 16, and August 12, respectively. The maximum number of net upstream migrating salmon was above the DIDSON monitoring site on August 27. Validation monitoring of DIDSON target counts with underwater optical cameras occurred for species identification. A total of 860 optical camera identified salmon passage observations were identical to DIDSON target counts. However, optical cameras identified eight jack salmon (3 upstream, 5 downstream) less than 55 cm in length that DIDSON did not count as salmon because of the length criteria employed ({ge} 55 cm). Precision of the DIDSON technology was evaluated by comparing estimated net upstream salmon escapement and associated 95% confidence intervals between two DIDSON sonar units operated over a five day period. The DIDSON 1 salmon escapement was 145.7 fish ({+-} 2.3), and the DIDSON 2 escapement estimate was 150.5 fish ({+-} 5). The overlap in the 95% confidence intervals suggested that the two escapement estimates were not significantly different from each other. Known length salmon carcass trials were conducted in 2008 to examine the accuracy of manually measured lengths, obtained using DIDSON software, on high frequency files at a 5 m window length. Linear regression demonstrated a highly significant relationship between known lengths and manually measured salmon carcass lengths (p < 0.0001). A positive bias in manual length measurement of 6.8% to 8% existed among the two observers in the analysis. Total Secesh River salmon escapement (natural origin and hatchery) in 2008 was 912 fish. Natural origin salmon escapement in the entire Secesh River drainage was 847 fish. The estimated natural origin spawner abundance was 836 fish. Salmon spawner abundance in 2008 increased by three fold compared to 2007 abundance levels. The 10 year geometric mean natural origin spawner abundance was 538 salmon and was below the recommended viable population threshold level established by the ICTRT (2007). One additional Snake River basin salmon population was assessed for comparison of natural origin salmon spawner abundance. The Johnson Creek/EFSF Salmon River population had a 10 year geometric mean natural origin spawner abundance of 254 salmon. Salmon spawner abundance levels in both streams were below viable population thresholds. DIDSON technology has been used in the Secesh River to determine salmon escapement over the past five years. The results suggest that DIDSON technology is reliable and can be used to generate accurate and precise estimates of salmon escapement if appropriate methods are used.

13 HYDRO ENERGY↗

Determining Atmospheric-Density Profile of Titan

A method was developed for measuring the atmospheric density of Titan, the largest moon of Saturn, to create an accurate density profile as a function of altitude. This will allow mission planners to select safe flyby altitudes, and for navigation engineers to accurately predict the delta-v associated with those flybys. The spacecraft angular rate vector profile as a function of time is collected via telemetry from the onboard attitude estimator once every 2 seconds. The telemetry for thruster times, as a function of time, for eight Reaction Control System (RCS) thrusters is gathered, once a second, from the Propulsion Manager algorithm of the Cassini onboard attitude-control flight software. Using these data, the ground software computes the angular momentum vector profile and the per-axis external torque as a function of time imparted from the spacecraft only due to the atmospheric drag. The software can then determine the Titan atmospheric density profile as a function of time and altitude with the known values of spacecraft center of mass, the Titan-relative range and velocity data, the projected area, and the aerocenter, along with the estimated drag coefficient in a free molecular flow field.

Sarani, Siamak↗

Performance Evaluation of an Advanced Distributed Energy Resource Management Algorithm

This paper presents performance evaluation of a new distributed energy resource management system (DERMS) algorithm via an advanced hardware-in-the-loop (HIL) platform. The HIL platform provides realistic testing in a laboratory environment, including the accurate modeling of sub-transmission and distribution networks, the DERMS software controller, and 84 power hardware solar photovoltaic (PV) inverters, standard communication protocols, and a capacitor bank controller. The DERMS algorithm is also called, Grid-Optimization of Solar (GO-Solar) platform which includes predictive state estimation (PSE) and online multiple objective optimization (OMOO) to dispatch the legacy devices and distributed energy resources (e.g., PV). The voltage regulation performance is evaluated under three scenarios, volt-var smart inverter (baseline), and DERMS control for 100% and 30% of PV. The results show that controlling 30% of PV systems with the GO-Solar platform may provide the best balance of control performance and implementation cost.

distributed energy resource management system (DER↗

PV Hosting Capacity Estimation: Experiences with Scalable Framework

Hosting capacity is an indication of the amount of solar photovoltaics (PV) that can be hosted in a distribution system without additional changes to infrastructure or oper-ations. This paper presents a framework for estimating the PV hosting capacity at scale. First, we analyze computational, modeling and other key challenges of performing relevant, large-scale simulations, provided along with the experiences and lessons learned. Then, we develop two open-source Python-based software tools to conduct repeatable distribution analyses: the Distribution Integration Solution Cost Options (DISCO) for configuring and analyzing simulations and the Job Automation and Deployment Engine (JADE) for parallelizing jobs on high-performance computing clusters. A case study of hosting capacity estimation for the SMART-DS San Francisco (SFO) 2000+ synthetic feeders, is used to demonstrate the capability of the developed DISCO+JADE framework and tools. The framework and tools can help utilities assess the overall hosting capacity of their service territory, which can help them better plan for the overall upgrade costs to integrate more PV in the future. The experiences are shared to aid the tool users and researchers to conduct relevant studies and research.

distributed energy resources↗

Automating Risk Assessments of Hazardous Material Shipments for Transportation Routes and Mode Selection

The METEOR project at Idaho National Laboratory (INL) successfully addresses the difficult problem in risk assessment analyses of combining the results from bounding deterministic simulation results with probabilistic (Monte Carlo) risk assessment techniques. This paper describes a software suite designed to perform sensitivity and cost/benefit analyses on selected transportation routes and vehicles to minimize risk associated with the shipment of hazardous materials. METEOR uses Monte Carlo techniques to estimate the probability of an accidental release of a hazardous substance along a proposed transportation route. A METEOR user selects the mode of transportation, origin and destination points, and charts the route using interactive graphics. Inputs to METEOR (many selections built in) include crash rates for the specific aircraft, soil/rock type and population densities over the proposed route, and bounding limits for potential accident types (velocity, temperature, etc.). New vehicle, materials, and location data are added when available. If the risk estimates are unacceptable, the risks associated with alternate transportation modes or routes can be quickly evaluated and compared. Systematic optimizing methods will provide the user with the route and vehicle selection identified with the lowest risk of hazardous material release. The effects of a selected range of potential accidents such as vehicle impact, fire, fuel explosions, excessive containment pressure, flooding, etc. are evaluated primarily using hydrocodes capable of accurately simulating the material response of critical containment components. Bounding conditions that represent credible accidents (i.e; for an impact event, velocity, orientations, and soil conditions) are used as input parameters to the hydrocode models yielding correlation functions relating accident parameters to component damage. The Monte Carlo algorithms use random number generators to make selections at the various decision points such as; crash, location, etc. For each pass through the routines, when a crash is randomly selected, crash parameters are then used to determine if failure has occurred using either external look up tables, correlations functions from deterministic calculations, or built in data libraries. The effectiveness of the software was recently demonstrated in safety analyses of the transportation of radioisotope systems for the US Dept. of Energy. These methods are readily adaptable to estimating risks associated with a variety of hazardous shipments such as spent nuclear fuel, explosives, and chemicals.

42 ENGINEERING↗

Deterministic absorbed dose estimation in computed tomography using a discrete ordinates method

Purpose: Organ dose estimation for a patient undergoing computed tomography (CT) scanning is very important. Although Monte Carlo methods are considered gold-standard in patient dose estimation, the computation time required is formidable for routine clinical calculations. Here, the authors instigate a deterministic method for estimating an absorbed dose more efficiently. Methods: Compared with current Monte Carlo methods, a more efficient approach to estimating the absorbed dose is to solve the linear Boltzmann equation numerically. In this study, an axial CT scan was modeled with a software package, Denovo, which solved the linear Boltzmann equation using the discrete ordinates method. The CT scanning configuration included 16 x-ray source positions, beam collimators, flat filters, and bowtie filters. The phantom was the standard 32 cm CT dose index (CTDI) phantom. Four different Denovo simulations were performed with different simulation parameters, including the number of quadrature sets and the order of Legendre polynomial expansions. A Monte Carlo simulation was also performed for benchmarking the Denovo simulations. A quantitative comparison was made of the simulation results obtained by the Denovo and the Monte Carlo methods. Results: The difference in the simulation results of the discrete ordinates method and those of the Monte Carlo methods was found to be small, with a root-mean-square difference of around 2.4%. It was found that the discrete ordinates method, with a higher order of Legendre polynomial expansions, underestimated the absorbed dose near the center of the phantom (i.e., low dose region). Simulations of the quadrature set 8 and the first order of the Legendre polynomial expansions proved to be the most efficient computation method in the authors’ study. The single-thread computation time of the deterministic simulation of the quadrature set 8 and the first order of the Legendre polynomial expansions was 21 min on a personal computer. Conclusions: The simulation results showed that the deterministic method can be effectively used to estimate the absorbed dose in a CTDI phantom. The accuracy of the discrete ordinates method was close to that of a Monte Carlo simulation, and the primary benefit of the discrete ordinates method lies in its rapid computation speed. It is expected that further optimization of this method in routine clinical CT dose estimation will improve its accuracy and speed.

07 ISOTOPE AND RADIATION SOURCES↗

Integrated Software for Analyzing Designs of Launch Vehicles

Launch Vehicle Analysis Tool (LVA) is a computer program for preliminary design structural analysis of launch vehicles. Before LVA was developed, in order to analyze the structure of a launch vehicle, it was necessary to estimate its weight, feed this estimate into a program to obtain pre-launch and flight loads, then feed these loads into structural and thermal analysis programs to obtain a second weight estimate. If the first and second weight estimates differed, it was necessary to reiterate these analyses until the solution converged. This process generally took six to twelve person-months of effort. LVA incorporates text to structural layout converter, configuration drawing, mass properties generation, pre-launch and flight loads analysis, loads output plotting, direct solution structural analysis, and thermal analysis subprograms. These subprograms are integrated in LVA so that solutions can be iterated automatically. LVA incorporates expert-system software that makes fundamental design decisions without intervention by the user. It also includes unique algorithms based on extensive research. The total integration of analysis modules drastically reduces the need for interaction with the user. A typical solution can be obtained in 30 to 60 minutes. Subsequent runs can be done in less than two minutes.

Philips, Alan D.↗

Evaluation of a semiautomated lung mass calculation technique for internal dosimetry applications

Purpose: The authors sought to evaluate a simple, semiautomated lung mass estimation method using computed tomography (CT) scans obtained using a variety of acquisition techniques and reconstruction parameters for mass correction of medical internal radiation dose-based internal radionuclide radiation absorbed dose estimates.Methods: CT scans of 27 patients with lung cancer undergoing stereotactic body radiation therapy treatment planning with PET/CT were analyzed retrospectively. For each patient, free-breathing (FB) and respiratory-gated 4DCT scans were acquired. The 4DCT scans were sorted into ten respiratory phases, representing one complete respiratory cycle. An average CT reconstruction was derived from the ten-phase reconstructions. Mid expiration breath-hold CT scans were acquired in the same session for many patients. Deep inspiration breath-hold diagnostic CT scans of many of the patients were obtained from different scanning sessions at similar time points to evaluate the effect of contrast administration and maximum inspiration breath-hold. Lung mass estimates were obtained using all CT scan types, and intercomparisons made to assess lung mass variation according to scan type. Lung mass estimates using the FB CT scans from PET/CT examinations of another group of ten male and ten female patients who were 21–30 years old and did not have lung disease were calculated and compared with reference lung mass values. To evaluate the effect of varying CT acquisition and reconstruction parameters on lung mass estimation, an anthropomorphic chest phantom was scanned and reconstructed with different CT parameters. CT images of the lungs were segmented using the OsiriX MD software program with a seed point of about −850 HU and an interval of 1000. Lung volume, and mean lung, tissue, and air HUs were recorded for each scan. Lung mass was calculated by assuming each voxel was a linear combination of only air and tissue. The specific gravity of lung volume was calculated using the formula (lung HU − air HU)/(tissue HU − air HU), and mass = specific gravity × total volume × 1.04 g/cm{sup 3}.Results: The range of calculated lung masses was 0.51–1.29 kg. The average male and female lung masses during FB CT were 0.80 and 0.71 kg, respectively. The calculated lung mass varied across the respiratory cycle but changed to a lesser degree than did lung volume measurements (7.3% versus 15.4%). Lung masses calculated using deep inspiration breath-hold and average CT were significantly larger (p < 0.05) than were some masses calculated using respiratory-phase and FB CT. Increased voxel size and smooth reconstruction kernels led to high lung mass estimates owing to partial volume effects.Conclusions: Organ mass correction is an important component of patient-specific internal radionuclide dosimetry. Lung mass calculation necessitates scan-based density correction to account for volume changes owing to respiration. The range of lung masses in the authors’ patient population represents lung doses for the same absorbed energy differing from 25% below to 64% above the dose found using reference phantom organ masses. With proper management of acquisition parameters and selection of FB or midexpiration breath hold scans, lung mass estimates with about 10% population precision may be achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Cost Comparison of Alternative Approaches to Distance Education in Developing Countries

This paper presents a cost comparison of three approaches to two-way interactive distance learning systems for developing countries. Included are costs for distance learning hardware, terrestrial and satellite communication links, and designing instruction for two-way interactive courses. As part of this project, FSEC is developing a 30-hour course in photovoltaic system design that will be used in a variety of experiments using the Advanced Communications Technology Satellite (ACTS). A primary goal of the project is to develop an instructional design and delivery model that can be used for other education and training programs. Over two-thirds of the world photovoltaics market is in developing countries. One of the objectives of this NASA-sponsored project was to develop new and better energy education programs that take advantage of advances in telecommunications and computer technology. The combination of desktop video systems and the sharing of computer applications software is of special interest. Research is being performed to evaluate the effectiveness of some of these technologies as part of this project. The design of the distance learning origination and receive sites discussed in this paper were influenced by the educational community's growing interest in distance education. The following approach was used to develop comparative costs for delivering interactive distance education to developing countries: (1) Representative target locations for receive sites were chosen. The originating site was assumed to be Cocoa, Florida, where FSEC is located; (2) A range of course development costs were determined; (3) The cost of equipment for three alternative two-way interactive distance learning system configurations was determined or estimated. The types of system configurations ranged from a PC-based system that allows instructors to originate instruction from their office using desktop video and shared application software, to a high cost system that uses a electronic classroom; (4) A range of costs for both satellite and terrestrial communications was investigated; (5) The costs of equipment and operation of the alternative configurations for the origination and receive sites were determined; (6) A range of costs for several alternative delivery scenarios (i.e., a mix of live-interactive; asynchronous interactive;use of videotapes) was determined; and (7) A preferred delivery scenario, including cost estimate, was developed.

Ventre, Gerard G.↗

Reference range of liver corrected T1 values in a population at low risk for fatty liver disease—a UK Biobank sub-study, with an appendix of interesting cases

Purpose: Corrected T1 (cT1) value is a novel MRI-based quantitative metric for assessing a composite of liver inflammation and fibrosis. It has been shown to distinguish between non-alcoholic fatty liver disease (NAFL) and non-alcoholic steatohepatitis. However, these studies were conducted in patients at high risk for liver disease. This study establishes the normal reference range of cT1 values for a large UK population, and assesses interactions of age and gender. Methods: MR data were acquired on a 1.5 T system as part of the UK Biobank Imaging Enhancement study. Measures for Proton Density Fat Fraction and cT1 were calculated from the MRI data using a multiparametric MRI software application. Data that did not meet quality criteria were excluded from further analysis. Inter and intra-reader variability was estimated in a set of data. A cohort at low risk for NAFL was identified by excluding individuals with BMI ≥ 25 kg/m{sup 2} and PDFF ≥ 5%. Of the 2816 participants with data of suitable quality, 1037 (37%) were classified as at low risk. Results: The cT1 values in the low-risk population ranged from 573 to 852 ms with a median of 666 ms and interquartile range from 643 to 694 ms. Iron correction of T1 was necessary in 36.5% of this reference population. Age and gender had minimal effect on cT1 values. Conclusion: The majority of cT1 values are tightly clustered in a population at low risk for NAFL, suggesting it has the potential to serve as a new quantitative imaging biomarker for studies of liver health and disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental evaluation of thermal-fluids performance of Helium-Cooled Flat Plate (HCFP) divertor

Various helium (He)-cooled solid-tungsten (W) divertor concepts have been proposed for long-pulse magnetic fusion energy reactors. Among these concepts, the He-cooled flat plate divertor (HCFP) modules have the largest plasma-facing surface area of ~0.2 m 2 . Simulations have shown that the most recent version of the design can withstand heat fluxes as great as 8 MW/m 2 . Earlier experimental studies of a single shortened HCFP cooling unit with a slot length of 7.6 cm used air at ambient temperature and pressures below 0.6 MPa. Here, we present initial experimental studies of a copper alloy and steel test section modeling a shortened HCFP cooling unit using He at prototypical pressure of 10 MPa, inlet temperatures T i ≤ 200 °C and steady-state incident heat fluxes q" ≤ 1.2 MW/m 2 . Results for Nusselt number Nu as a function of Reynolds number Re were obtained for Re = 1.2×10 4 –3.4×10 4 , and used to develop a Nu(Re) correlation and validate numerical models of the test section using commercial computational fluid dynamics (CFD) software. Simulations with this model are performed to evaluate the effect of the shortened slot. Furthermore, these analyses are used to estimate the thermal-fluids performance of the HCFP under prototypical conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗