Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “smoothness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Mach 5 electroformed nickel nozzle refurbishment FNAS investigation of ultra-smooth surfaces

This task is in support of the Quiet Hypersonic Wind Tunnel effort currently in effect at NASA Langley Research Center, VA. A laminar flow wind tunnel nozzle has been previously fabricated by electroforming pure nickel over a machined and polished two piece stainless steel mandrel. The mandrel was removed leaving the replicate nozzle surface. The nozzle was then pressed into a heavy stainless steel jacket for mounting features and rigidity. The original nickel surface was a replication of the polished mandrel but had degraded due to oxidation. The inside surface requirements are very stringent in order to achieve laminar or quiet flow at the desired pressure and temperature for the specific design of Mach 5. The throat area of the axisymmetric device must have a surface finish with no defects greater than 16 microinches. This requires an rms average background of about four microinches or better for inspection purposes. A coating of nickel-phosphorous alloy was applied by catalytic deposition and then the inside of the nozzle was polished retaining dimensional and surface finish tolerances as specified per drawings supplied. Since the unit is not an optical component, conventional optical inspection methods for surface finish and figure are not readily achieved. Measurements were made using surface profilometry.

Rood, Robert↗

Design of optimally smoothing multistage schemes for the Euler equations

A recently derived local preconditioning of the Euler equations is shown to be useful in developing multistage schemes suited for multigrid use. The effect of the preconditioning matrix on the spatial Euler operator is to equalize the characteristic speeds. When applied to the discretized Euler equations, the preconditioning has the effect of strongly clustering the operator's eigenvalues in the complex plane. This makes possible the development of explicit marching schemes that effectively damp most high-frequency Fourier modes, as desired in multigrid applications. The technique is the same as developed earlier for scalar convection schemes: placement of the zeros of the amplification factor of the multistage scheme in locations where eigenvalues corresponding to high-frequency modes abound.

Van Leer, Bram↗

Quartz dissolution. I - Negative crystal experiments and a rate law. II - Theory of rough and smooth surfaces

The range of the measured quartz dissolution rates, as a function of temperature and pOH, extent of saturation, and ionic strength, is extended to cover a wider range of solution chemistries, using the negative crystal methodology of Gratz et al. (1990) to measure the dissolution rate. A simple rate law describing the quartz dissolution kinetics above the point of zero charge of quartz is derived for ionic strengths above 0.003 m. Measurements were performed on some defective crystals, and the mathematics of step motion was developed for quartz dissolution and was compared with rough-face behavior using two different models.

Gratz, Andrew J.↗

A method of smooth bivariate interpolation for data given on a generalized curvilinear grid

A method of locally bicubic interpolation is presented for data given at the nodes of a two-dimensional generalized curvilinear grid. The physical domain is transformed to a computational domain in which the grid is uniform and rectangular by a generalized curvilinear coordinate transformation. The metrics of the transformation are obtained by finite differences in the computational domain. Metric derivatives are determined by repeated application of the chain rule for partial differentiation. Given the metrics and the metric derivatives, the partial derivatives required to determine a locally bicubic interpolant can be estimated at each data point using finite differences in the computational domain. A bilinear transformation is used to analytically transform the individual quadrilateral cells in the physical domain into unit squares, thus allowing the use of simple formulas for bicubic interpolation.

Zingg, David W.↗

Experiment-specific cosmic microwave background calculations made easier - Approximation formula for smoothed delta T/T windows

Simple and easy to implement elementary function approximations are introduced to the spectral window functions needed in calculations of model predictions of the cosmic microwave backgrond (CMB) anisotropy. These approximations allow the investigator to obtain model delta T/T predictions in terms of single integrals over the power spectrum of cosmological perturbations and to avoid the necessity of performing the additional integrations. The high accuracy of these approximations is demonstrated here for the CDM theory-based calculations of the expected delta T/T signal in several experiments searching for the CMB anisotropy.

Gorski, Krzysztof M.↗

Generalized Charts for Determination of Pressure Drop of a High-speed Compressible Fluid in Heat-exchanger Passages I : Air Heated in Smooth Passages of Constant Area with Constant Wall Temperature

In the present paper an analysis is made of the compressible-flow variations occurring in heat-exchanger passages. The results of the analysis describe the flow and heating characteristics for which specific flow passages can be treated as segments of generalized flow systems. The graphical representation of the flow variations in the generalized flow systems can then be utilized as working charts to determine directly the pressure changes occurring in any specific flow passage. On the basis of these results, working charts are constructed to handle the case of air heated at constant wall temperature under turbulent-flow conditions. A method is given of incorporating the effect on the heat-exchanger flow process of high temperature differential between passage wall and fluid as based on recent NACA experimental data. Good agreement is obtained between the experimental and the chart pressure-drop values for passage-wall average temperatures as high as 1752 degrees R (experimental limit) and for flow Mach numbers ranging from 0.32 to 1.00 (choke) at the passage exit.

Valerino, Michael F↗

Correlation of Forced-convection Heat-transfer Data for Air Flowing in Smooth Platinum Tube with Long-approach Entrance at High Surface and Inlet-air Temperatures

A heat-transfer investigation was conducted with air in an electrically heated platinum tube with long-approach entrance, inside diameter of 0.525 inch, and effective heat-transfer length of 24 inches over ranges of Reynolds number up to 320,000, average inside-tube-wall temperature up to 3053 degrees R, and inlet-air temperature up to 1165 degrees R. Correlation of data by the conventional Nusselt relation resulted in separation of data with tube-wall temperature. Good correlation was obtained, however, by use of a modified Reynolds number.

Desmon, Leland G↗