Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “serialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Interpretation of the dosimetric results of three uniformity regularization methods in terms of expected treatment outcome

In IMRT treatment plan optimization there are various methods that try to regularize the variation of dose nonuniformity using purely dosimetric measures. However, although these methods can help in finding a good dose distribution, they do not provide any information regarding the expected treatment outcome. When a treatment plan optimization is performed using biological measures, the final goal should be some indication about the expected tumor control or normal tissue complications, which is the primary goal of treatment planning (the association of treatment configurations and dose prescription with the treatment outcome). In this study, this issue is analyzed distinguishing the dose-oriented treatment plan optimization from the response-oriented optimization. Three different dose distributions were obtained by using a dose-based optimization technique, an EUD-based optimization without applying any technique for regularizing the nonuniformity of the dose distribution, and an EUD-based optimization using a variational regularization technique, which controls dose nonuniformity. The clinical effectiveness of the three dose distributions was investigated by calculating the response probabilities of the tumors and organs-at-risk (OARs) involved in two head and neck and prostate cancer cases. The radiobiological models used are the linear-quadratic-Poisson and the Relative Seriality models. Furthermore, the complication-free tumor control probability and the biologically effective uniform dose (D-bar) were used for treatment plan evaluation and comparison. The radiobiological comparison shows that the EUD-based optimization using L-curve regularization gives better results than the EUD-based optimization without regularization and dose-based optimization in both clinical cases. Concluding, it appears that the applied dose nonuniformity regularization technique is expected to improve the effectiveness of the optimized IMRT dose distributions. However, more patient cases are needed to validate the statistical significance of the results and conclusions presented in this paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of a water-equivalent fiber-optic coupled dosimeter for use in diagnostic radiology

This work reports on the characterization of a new fiber-optic coupled (FOC) dosimeter for use in the diagnostic radiology energy range. The FOC dosimeter was constructed by coupling a small cylindrical plastic scintillator, 500 {mu}m in diameter and 2 mm in length, to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube (PMT). A serial port interface on the PMT permits real-time monitoring of light output from the dosimeter via a custom computer program. The FOC dosimeter offered excellent sensitivity and reproducibility, allowing doses as low as 0.16 mGy to be measured with a coefficient of variation of only 3.64%. Dose linearity was also excellent with a correlation coefficient of 1.000 over exposures ranging from 0.16 to 57.29 mGy. The FOC dosimeter exhibited little angular dependence from axial irradiation, varying by less than 5% over an entire revolution. A positive energy dependence was observed and measurements performed within a scatter medium yielded a 10% variation in sensitivity as beam quality changed due to hardening and scatter across a 16 cm depth range. The current dosimetry system features an array of five PMTs to allow multiple FOC dosimeters to be monitored simultaneously. Overall, the system allows for rapid and accurate dose measurements relevant to a range of diagnostic imaging applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose convolution filter: Incorporating spatial dose information into tissue response modeling

Purpose: A model is introduced to integrate biological factors such as cell migration and bystander effects into physical dose distributions, and to incorporate spatial dose information in plan analysis and optimization. Methods: The model consists of a dose convolution filter (DCF) with single parameter {sigma}. Tissue response is calculated by an existing NTCP model with DCF-applied dose distribution as input. The authors determined {sigma} of rat spinal cord from published data. The authors also simulated the GRID technique, in which an open field is collimated into many pencil beams. Results: After applying the DCF, the NTCP model successfully fits the rat spinal cord data with a predicted value of {sigma}=2.6{+-}0.5 mm, consistent with 2 mm migration distances of remyelinating cells. Moreover, it enables the appropriate prediction of a high relative seriality for spinal cord. The model also predicts the sparing of normal tissues by the GRID technique when the size of each pencil beam becomes comparable to {sigma}. Conclusions: The DCF model incorporates spatial dose information and offers an improved way to estimate tissue response from complex radiotherapy dose distributions. It does not alter the prediction of tissue response in large homogenous fields, but successfully predicts increased tissue tolerance in small or highly nonuniform fields.

61 RADIATION PROTECTION AND DOSIMETRY↗

GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variation

Purpose: Cone-beam CT (CBCT) plays an important role in image guided radiation therapy (IGRT). However, the large radiation dose from serial CBCT scans in most IGRT procedures raises a clinical concern, especially for pediatric patients who are essentially excluded from receiving IGRT for this reason. The goal of this work is to develop a fast GPU-based algorithm to reconstruct CBCT from undersampled and noisy projection data so as to lower the imaging dose. Methods: The CBCT is reconstructed by minimizing an energy functional consisting of a data fidelity term and a total variation regularization term. The authors developed a GPU-friendly version of the forward-backward splitting algorithm to solve this model. A multigrid technique is also employed. Results: It is found that 20-40 x-ray projections are sufficient to reconstruct images with satisfactory quality for IGRT. The reconstruction time ranges from 77 to 130 s on an NVIDIA Tesla C1060 (NVIDIA, Santa Clara, CA) GPU card, depending on the number of projections used, which is estimated about 100 times faster than similar iterative reconstruction approaches. Moreover, phantom studies indicate that the algorithm enables the CBCT to be reconstructed under a scanning protocol with as low as 0.1 mA s/projection. Comparing with currently widely used full-fan head and neck scanning protocol of {approx}360 projections with 0.4 mA s/projection, it is estimated that an overall 36-72 times dose reduction has been achieved in our fast CBCT reconstruction algorithm. Conclusions: This work indicates that the developed GPU-based CBCT reconstruction algorithm is capable of lowering imaging dose considerably. The high computation efficiency in this algorithm makes the iterative CBCT reconstruction approach applicable in real clinical environments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated registration of diagnostic to prediagnostic x-ray mammograms: Evaluation and comparison to radiologists' accuracy

Purpose: To compare and evaluate intensity-based registration methods for computation of serial x-ray mammogram correspondence. Methods: X-ray mammograms were simulated from MRIs of 20 women using finite element methods for modeling breast compressions and employing a MRI/x-ray appearance change model. The parameter configurations of three registration methods, affine, fluid, and free-form deformation (FFD), were optimized for registering x-ray mammograms on these simulated images. Five mammography film readers independently identified landmarks (tumor, nipple, and usually two other normal features) on pairs of diagnostic and corresponding prediagnostic digitized images from 52 breast cancer cases. Landmarks were independently reidentified by each reader. Target registration errors were calculated to compare the three registration methods using the reader landmarks as a gold standard. Data were analyzed using multilevel methods. Results: Between-reader variability varied with landmark (p<0.01) and screen (p=0.03), with between-reader mean distance (mm) in point location on the diagnostic/prediagnostic images of 2.50 (95% CI 1.95, 3.15)/2.84 (2.24, 3.55) for nipples and 4.26 (3.43, 5.24)/4.76 (3.85, 5.84) for tumors. Registration accuracy was sensitive to the type of landmark and the amount of breast density. For dense breasts ({>=}40%), the affine and fluid methods outperformed FFD. For breasts with lower density, the affine registration surpassed both fluid and FFD. Mean accuracy (mm) of the affine registration varied between 3.16 (95% CI 2.56, 3.90) for nipple points in breasts with density 20%-39% and 5.73 (4.80, 6.84) for tumor points in breasts with density <20%. Conclusions: Affine registration accuracy was comparable to that between independent film readers. More advanced two-dimensional nonrigid registration algorithms were incapable of increasing the accuracy of image alignment when compared to affine registration.

60 APPLIED LIFE SCIENCES↗

Assessment of normal tissue complications following prostate cancer irradiation: Comparison of radiation treatment modalities using NTCP models

Purpose: Normal tissue complication probability (NTCP) of the rectum, bladder, urethra, and femoral heads following several techniques for radiation treatment of prostate cancer were evaluated applying the relative seriality and Lyman models. Methods: Model parameters from literature were used in this evaluation. The treatment techniques included external (standard fractionated, hypofractionated, and dose-escalated) three-dimensional conformal radiotherapy (3D-CRT), low-dose-rate (LDR) brachytherapy (I-125 seeds), and high-dose-rate (HDR) brachytherapy (Ir-192 source). Dose-volume histograms (DVHs) of the rectum, bladder, and urethra retrieved from corresponding treatment planning systems were converted to biological effective dose-based and equivalent dose-based DVHs, respectively, in order to account for differences in radiation treatment modality and fractionation schedule. Results: Results indicated that with hypofractionated 3D-CRT (20 fractions of 2.75 Gy/fraction delivered five times/week to total dose of 55 Gy), NTCP of the rectum, bladder, and urethra were less than those for standard fractionated 3D-CRT using a four-field technique (32 fractions of 2 Gy/fraction delivered five times/week to total dose of 64 Gy) and dose-escalated 3D-CRT. Rectal and bladder NTCPs (5.2% and 6.6%, respectively) following the dose-escalated four-field 3D-CRT (2 Gy/fraction to total dose of 74 Gy) were the highest among analyzed treatment techniques. The average NTCP for the rectum and urethra were 0.6% and 24.7% for LDR-BT and 0.5% and 11.2% for HDR-BT. Conclusions: Although brachytherapy techniques resulted in delivering larger equivalent doses to normal tissues, the corresponding NTCPs were lower than those of external beam techniques other than the urethra because of much smaller volumes irradiated to higher doses. Among analyzed normal tissues, the femoral heads were found to have the lowest probability of complications as most of their volume was irradiated to lower equivalent doses compared to other tissues.

60 APPLIED LIFE SCIENCES↗

Dose calculation for permanent prostate implants incorporating spatially anisotropic linearly time-resolving edema

Purpose: The objectives of this study were (i) to develop a dose calculation method for permanent prostate implants that incorporates a clinically motivated model for edema and (ii) to illustrate the use of the method by calculating the preimplant dosimetry error for a reference configuration of {sup 125}I, {sup 103}Pd, and {sup 137}Cs seeds subject to edema-induced motions corresponding to a variety of model parameters. Methods: A model for spatially anisotropic edema that resolves linearly with time was developed based on serial magnetic resonance imaging measurements made previously at our center to characterize the edema for a group of n=40 prostate implant patients [R. S. Sloboda et al., ''Time course of prostatic edema post permanent seed implant determined by magnetic resonance imaging,'' Brachytherapy 9, 354-361 (2010)]. Model parameters consisted of edema magnitude, {Delta}, and period, T. The TG-43 dose calculation formalism for a point source was extended to incorporate the edema model, thus enabling calculation via numerical integration of the cumulative dose around an individual seed in the presence of edema. Using an even power piecewise-continuous polynomial representation for the radial dose function, the cumulative dose was also expressed in closed analytical form. Application of the method was illustrated by calculating the preimplant dosimetry error, RE{sub preplan}, in a 5x5x5 cm{sup 3} volume for {sup 125}I (Oncura 6711), {sup 103}Pd (Theragenics 200), and {sup 131}Cs (IsoRay CS-1) seeds arranged in the Radiological Physics Center test case 2 configuration for a range of edema relative magnitudes ({Delta}=[0.1,0.2,0.4,0.6,1.0]) and periods (T=[28,56,84] d). Results were compared to preimplant dosimetry errors calculated using a variation of the isotropic edema model developed by Chen et al. [''Dosimetric effects of edema in permanent prostate seed implants: A rigorous solution,'' Int. J. Radiat. Oncol., Biol., Phys. 47, 1405-1419 (2000)]. Results: As expected, RE{sub preplan} for our edema model indicated underdosage in the calculation volume with a clear dependence on seed and calculation point positions, and increased with increasing values of {Delta} and T. Values of RE{sub preplan} were generally larger near the ends of the virtual prostate in the RPC phantom compared with more central locations. For edema characteristics similar to the population average values previously measured at our center, i.e., {Delta}=0.2 and T=28 d, mean values of RE{sub preplan} in an axial plane located 1.5 cm from the center of the seed distribution were 8.3% for {sup 131}Cs seeds, 7.5% for {sup 103}Pd seeds, and 2.2% for {sup 125}I seeds. Maximum values of RE{sub preplan} in the same plane were about 1.5 times greater. Note that detailed results strictly apply only for loose seed implants where the seeds are fixed in tissue and move in synchrony with that tissue. Conclusions: A dose calculation method for permanent prostate implants incorporating spatially anisotropic linearly time-resolving edema was developed for which cumulative dose can be written in closed form. The method yields values for RE{sub preplan} that differ from those for spatially isotropic edema. The method is suitable for calculating pre- and postimplant dosimetry correction factors for clinical seed configurations when edema characteristics can be measured or estimated.

60 APPLIED LIFE SCIENCES↗

Iodine kinetics and dosimetry in the salivary glands during repeated courses of radioiodine therapy for thyroid cancer

Purpose: The present study was conducted to investigate salivary iodine kinetics and dosimetry during repeated courses of radioiodine ({sup 131}I) therapy for differentiated thyroid cancer (DTC). Such data could provide a better understanding of the mechanisms of {sup 131}I induced salivary toxicity and help to develop appropriate methods to reduce this injury. Methods: Seventy-eight consecutive DTC patients (mean age 45 {+-} 17 years, 60%, female) undergoing {sup 131}I therapy for remnant ablation or metastatic tumors were prospectively recruited. Planar quantitative scintigraphy of head-neck images was serially acquired after administration of 2.9-7.4 GBq of {sup 131}I to assess kinetics in the salivary glands of patients. Salivary absorbed doses were calculated based on the schema of Medical Internal Radiation Dosimetry. Results: The maximum uptakes in percentage of administered {sup 131}I activity per kilogram of gland tissue (%/kg) were 12.9% {+-} 6.5%/kg (range, 0.4%-37.3%/kg) and 12.3% {+-} 6.2%/kg (range, 0.4%-35.1%/kg) for the parotid and submandibular glands, respectively. Statistically significant correlations of maximum uptake versus cumulative activity (r = -0.74, P < 0.01, for the parotid glands; r = -0.71, P < 0.01, for the submandibular glands) and treatment cycle (P < 0.001, for both gland types) were found. The effective half-lives of {sup 131}I in the parotid and submandibular glands were 9.3 {+-} 3.5 h (range, 1.5-19.8 h) and 8.6 {+-} 3.2 h (range, 0.8-18.0 h), respectively. A statistically significant correlation was observed between effective half-life with cumulative activity (r = 0.37, P < 0.01) and treatment cycle (P = 0.03) only for the parotid glands. The calculated absorbed doses were 0.20 {+-} 0.10 mGy/MBq (range, 0.01-0.92 mGy/MBq) and 0.25 {+-} 0.09 mGy/MBq (range, 0.01-1.52 mGy/MBq) for the parotid and submandibular glands, respectively. The photon contribution to the salivary absorbed dose was minimal in relation to the beta dose contribution. Photon-absorbed dose fractions of total absorbed dose were 4.9% {+-} 1.3% (range, 1.1%-8.7%) and 3.7% {+-} 2.5% (range, 0.8%-7.9%) for the parotid and submandibular glands, respectively. Conclusions: The iodine uptake of salivary glands is continuously reduced during the courses of therapy. The phenomenon of hyper-radiosensitivity may to some extent account for the occurrence of salivary gland hypofunction at very low radiation doses with low dose rates in {sup 131}I therapy. On the other hand, failure to incorporate a nonuniform and preferential uptake by salivary gland ductal cells may result in underestimating the actual dose for the critical tissue. Other methods, including {sup 124}I voxel-based dosimetry, are warranted to further investigate the {sup 131}I-induced salivary gland toxicity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Learning statistical correlation for fast prostate registration in image-guided radiotherapy

Purpose: In adaptive radiation therapy of prostate cancer, fast and accurate registration between the planning image and treatment images of the patient is of essential importance. With the authors' recently developed deformable surface model, prostate boundaries in each treatment image can be rapidly segmented and their correspondences (or relative deformations) to the prostate boundaries in the planning image are also established automatically. However, the dense correspondences on the nonboundary regions, which are important especially for transforming the treatment plan designed in the planning image space to each treatment image space, are remained unresolved. This paper presents a novel approach to learn the statistical correlation between deformations of prostate boundary and nonboundary regions, for rapidly estimating deformations of the nonboundary regions when given the deformations of the prostate boundary at a new treatment image. Methods: The main contributions of the proposed method lie in the following aspects. First, the statistical deformation correlation will be learned from both current patient and other training patients, and further updated adaptively during the radiotherapy. Specifically, in the initial treatment stage when the number of treatment images collected from the current patient is small, the statistical deformation correlation is mainly learned from other training patients. As more treatment images are collected from the current patient, the patient-specific information will play a more important role in learning patient-specific statistical deformation correlation to effectively reflect prostate deformation of the current patient during the treatment. Eventually, only the patient-specific statistical deformation correlation is used to estimate dense correspondences when a sufficient number of treatment images have been acquired from the current patient. Second, the statistical deformation correlation will be learned by using a multiple linear regression (MLR) model, i.e., ridge regression (RR) model, which has the best prediction accuracy than other MLR models such as canonical correlation analysis (CCA) and principal component regression (PCR). Results: To demonstrate the performance of the proposed method, we first evaluate its registration accuracy by comparing the deformation field predicted by our method with the deformation field estimated by the thin plate spline (TPS) based correspondence interpolation method on 306 serial prostate CT images of 24 patients. The average predictive error on the voxels around 5 mm of prostate boundary is 0.38 mm for our method of RR-based correlation model. Also, the corresponding maximum error is 2.89 mm. We then compare the speed for deformation interpolation by different methods. When considering the larger region of interest (ROI) with the size of 512 x 512 x 61, our method takes 24.41 seconds to interpolate the dense deformation field while TPS method needs 6.7 minutes; when considering a small ROI (surrounding prostate) with size of 112 x 110 x 93, our method takes 1.80 seconds, while TPS method needs 25 seconds. Conclusions: Experimental results show that the proposed method can achieve much faster registration speed yet with comparable registration accuracy, compared to the TPS-based correspondence (or deformation) interpolation approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Verification of Gamma Knife extend system based fractionated treatment planning using EBT2 film

Purpose: This paper presents EBT2 film verification of fractionated treatment planning with the Gamma Knife (GK) extend system, a relocatable frame system for multiple-fraction or serial multiple-session radiosurgery.Methods: A human head shaped phantom simulated the verification process for fractionated Gamma Knife treatment. Phantom preparation for Extend Frame based treatment planning involved creating a dental impression, fitting the phantom to the frame system, and acquiring a stereotactic computed tomography (CT) scan. A CT scan (Siemens, Emotion 6) of the phantom was obtained with following parameters: Tube voltage—110 kV, tube current—280 mA, pixel size—0.5 × 0.5 and 1 mm slice thickness. A treatment plan with two 8 mm collimator shots and three sectors blocking in each shot was made. Dose prescription of 4 Gy at 100% was delivered for the first fraction out of the two fractions planned. Gafchromic EBT2 film (ISP Wayne, NJ) was used as 2D verification dosimeter in this process. Films were cut and placed inside the film insert of the phantom for treatment dose delivery. Meanwhile a set of films from the same batch were exposed from 0 to 12 Gy doses for calibration purposes. An EPSON (Expression 10000 XL) scanner was used for scanning the exposed films in transparency mode. Scanned films were analyzed with inhouse written MATLAB codes.Results: Gamma index analysis of film measurement in comparison with TPS calculated dose resulted in high pass rates >90% for tolerance criteria of 1%/1 mm. The isodose overlay and linear dose profiles of film measured and computed dose distribution on sagittal and coronal plane were in close agreement.Conclusions: Through this study, the authors propose treatment verification QA method for Extend frame based fractionated Gamma Knife radiosurgery using EBT2 film.

61 RADIATION PROTECTION AND DOSIMETRY↗

Longitudinal, intermodality registration of quantitative breast PET and MRI data acquired before and during neoadjuvant chemotherapy: Preliminary results

Purpose: The authors propose a method whereby serially acquired DCE-MRI, DW-MRI, and FDG-PET breast data sets can be spatially and temporally coregistered to enable the comparison of changes in parameter maps at the voxel level. Methods: First, the authors aligned the PET and MR images at each time point rigidly and nonrigidly. To register the MR images longitudinally, the authors extended a nonrigid registration algorithm by including a tumor volume-preserving constraint in the cost function. After the PET images were aligned to the MR images at each time point, the authors then used the transformation obtained from the longitudinal registration of the MRI volumes to register the PET images longitudinally. The authors tested this approach on ten breast cancer patients by calculating a modified Dice similarity of tumor size between the PET and MR images as well as the bending energy and changes in the tumor volume after the application of the registration algorithm. Results: The median of the modified Dice in the registered PET and DCE-MRI data was 0.92. For the longitudinal registration, the median tumor volume change was −0.03% for the constrained algorithm, compared to −32.16% for the unconstrained registration algorithms (p = 8 × 10{sup −6}). The medians of the bending energy were 0.0092 and 0.0001 for the unconstrained and constrained algorithms, respectively (p = 2.84 × 10{sup −7}). Conclusions: The results indicate that the proposed method can accurately spatially align DCE-MRI, DW-MRI, and FDG-PET breast images acquired at different time points during therapy while preventing the tumor from being substantially distorted or compressed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Semiautomatic segmentation of aortic valve from sequenced ultrasound image using a novel shape-constraint GCV model

Purpose: Effective and accurate segmentation of the aortic valve (AV) from sequenced ultrasound (US) images remains a technical challenge because of intrinsic factors of ultrasound images that impact the quality and the continuous changes of shape and position of segmented objects. In this paper, a novel shape-constraint gradient Chan-Vese (GCV) model is proposed for segmenting the AV from time serial echocardiography. Methods: The GCV model is derived by incorporating the energy of the gradient vector flow into a CV model framework, where the gradient vector energy term is introduced by calculating the deviation angle between the inward normal force of the evolution contour and the gradient vector force. The flow force enlarges the capture range and enhances the blurred boundaries of objects. This is achieved by adding a circle-like contour (constructed using the AV structure region as a constraint shape) as an energy item to the GCV model through the shape comparison function. This shape-constrained energy can enhance the image constraint force by effectively connecting separate gaps of the object edge as well as driving the evolution contour to quickly approach the ideal object. Because of the slight movement of the AV in adjacent frames, the initial constraint shape is defined by users, with the other constraint shapes being derived from the segmentation results of adjacent sequence frames after morphological filtering. The AV is segmented from the US images by minimizing the proposed energy function. Results: To evaluate the performance of the proposed method, five assessment parameters were used to compare it with manual delineations performed by radiologists (gold standards). Three hundred and fifteen images acquired from nine groups were analyzed in the experiment. The area-metric overlap error rate was 6.89% ± 2.88%, the relative area difference rate 3.94% ± 2.63%, the average symmetric contour distance 1.08 ± 0.43 mm, the root mean square symmetric contour distance 1.37 ± 0.52 mm, and the maximum symmetric contour distance was 3.57 ± 1.72 mm. Conclusions: Compared with the CV model, as a result of the combination of the gradient vector and neighborhood shape information, this semiautomatic segmentation method significantly improves the accuracy and robustness of AV segmentation, making it feasible for improved segmentation of aortic valves from US images that have fuzzy boundaries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality control procedures for dynamic treatment delivery techniques involving couch motion

In this study, the authors introduce and demonstrate quality control procedures for evaluating the geometric and dosimetric fidelity of dynamic treatment delivery techniques involving treatment couch motion synchronous with gantry and multileaf collimator (MLC). Tests were designed to evaluate positional accuracy, velocity constancy and accuracy for dynamic couch motion under a realistic weight load. A test evaluating the geometric accuracy of the system in delivering treatments over complex dynamic trajectories was also devised. Custom XML scripts that control the Varian TrueBeam™ STx (Serial #3) axes in Developer Mode were written to implement the delivery sequences for the tests. Delivered dose patterns were captured with radiographic film or the electronic portal imaging device. The couch translational accuracy in dynamic treatment mode was 0.01 cm. Rotational accuracy was within 0.3°, with 0.04 cm displacement of the rotational axis. Dose intensity profiles capturing the velocity constancy and accuracy for translations and rotation exhibited standard deviation and maximum deviations below 3%. For complex delivery involving MLC and couch motions, the overall translational accuracy for reproducing programmed patterns was within 0.06 cm. The authors conclude that in Developer Mode, TrueBeam™ is capable of delivering dynamic treatment delivery techniques involving couch motion with good geometric and dosimetric fidelity.

60 APPLIED LIFE SCIENCES↗

SU-E-I-78: Improving Prostatic Delineation Using Dual-Energy CT

Purpose: Visual prostatic definition is difficult using conventional CT. This is because the prostate is surrounded closely with tissue of similar electron density. Definition is further hindered when the region contains high-Z material (such as fiducial markers). Dual-energy CT (DECT) is a technique where images are rendered using two tube voltages during a single scan session. This study evaluates DECT as a means of improving prostatic volume delineation for radiation oncology. Methods: The patients were scanned using a Definition AS20 (Siemens Healthcare, Malvern, PA). This device uses a single-tube configuration, where two scans of differing energies are performed in serial. The scans are acquired with tube voltage of 80kVp and 140kVp. Following acquisition, these scan data were used to generate effective monoenergetic scans ranging from 40keV to 190keV. In the current study, the data were presented to observers using a novel program, which allows real-time adjustment of window, level, and effective keV; all while scrolling through volumetric slices. Three patients were scanned, each with a different high-contrast material in or around the prostate: I-125 seeds, gold fiducial markers, and prostatic calcifications. These images are compared to a weighted average of the 80kVp and 140kVP scans, which yield a scan similar to that of a 120 kVp scan, which is a common tube voltage in radiation oncology. Results: Prostatic definition improved in each case. Differentiation of soft tissue from surrounding adipose improved with lower keV, while higher keV provided a reduction of high-z artifacts. Furthermore, the dynamic adjustment of the keV allowed observers to better recognize regions of differing tissue composition within this relatively homogeneous area. Conclusion: By simultaneously providing the observer with the benefits of high-energy images and low-energy images, and allowing adjustment in real-time, improved imaging in highly homogeneous regions such as the male pelvis is achievable.

60 APPLIED LIFE SCIENCES↗

SU-E-J-122: Detecting Treatment-Induced Metabolic Abnormalities in Craniopharyngioma Patients Undergoing Surgery and Proton Therapy

Purpose: To identify treatment-induced defects in the brain of children with craniopharyngioma receiving surgery and proton therapy using fluorodeoxyglucose positron emission tomography (FDG PET). Methods: Forty seven patients were enrolled on a clinical trial for craniopharyngioma with serial imaging and functional evaluations. Proton therapy was delivered using the double-scattered beams with a prescribed dose of 54 Cobalt Gray Equivalent. FDG tracer uptake in each of 63 anatomical regions was computed after warping PET images to a 3D reference template in Talairach coordinates. Regional uptake was deemed significantly low or high if exceeding two standard deviations of normal population from the mean. For establishing the normal ranges, 132 children aged 1–20 years with noncentral nervous system related diseases and normal-appearing cerebral PET scans were analyzed. Age- and gender-dependent regional uptake models were developed by linear regression and confidence intervals were calculated. Results: Most common PET abnormality before proton therapy was significantly low uptake in the frontal lobe, the occipital lobe (particularly in cuneus), the medial and ventral temporal lobe, cingulate gyrus, caudate nuclei, and thalamus. They were related to injury from surgical corridors, tumor mass effect, insertion of a ventricular catheter, and the placement of an Ommaya reservoir. Surprisingly a significantly high uptake was observed in temporal gyri and the parietal lobe. In 13 patients who already completed 18-month PET scans, metabolic abnormalities improved in 11 patients from baseline. One patient had persistent abnormalities. Only one revealed new uptake abnormalities in thalamus, brainstem, cerebellum, and insula. Conclusion: Postoperative FDG PET of craniopharyngioma patients revealed metabolic abnormalities in specific regions of the brain. Proton therapy did not appear to exacerbate these surgery- and tumor-induced defects. In patients with persistent and new abnormalities, continued investigation on clinical symptoms and cognitive outcomes is ongoing to establish the association and predictive values of metabolic imaging.

60 APPLIED LIFE SCIENCES↗

SU-E-J-148: Evaluating Tumor Response with a Commercially Available Deformable Registration System

Purpose: The purpose of this study is to present a method for evaluating the response to treatment using a commercially available deformable image registration software package (Velocity Medical Systems) and repeat PET/CT imaging. This technique can be used to identify volumes that are risk for tumor recurrence. Methods: Response to treatment was evaluated using PET/CT images acquired prior-to and post-treatment for radiation therapy patients treated with concurrent chemotherapy. Velocity (Version 3.0.1) was used to deform the initial PET/CT to the post treatment PET/CT. The post-treatment PET images were then subtracted from the pre-treatment PET images. The resulting re-sampled image is a three-dimensional SUV difference map that shows pixels with increasing SUV values. SUV values increases greater than 2.5 in the post treatment images were identified for additional follow-up. Results: A total of 5 Lung patients were analyzed as part of this study. One lung patient in the cohort had an SUV increase of +3.28 that was identified using the SUV difference map. This volume of increased uptake was located outside the treatment field and adjacent to the 35 Gy isodose line. The remaining four patients all had SUV decreases inside the planning target volume, and no unexpected areas of increase outside the irradiated volumes. All five patients were analyzed using standard tools inside the Velocity application. Conclusion: The response to treatment can easily be measured using serial PET/CT images and a commercially available deformable image registration. This provides both the radiation oncologists and medical oncologists with a quantitative assessment of their treatment to use in patient follow-up.

60 APPLIED LIFE SCIENCES↗

SU-E-T-345: Validation of a Patient-Specific Monte Carlo Targeted Radionuclide Therapy Dosimetry Platform

Purpose: There is a compelling need for personalized dosimetry in targeted radionuclide therapy given that conventional dose calculation methods fail to accurately predict dose response relationships. To address this need, we have developed a Geant4-based Monte Carlo patient-specific 3D dosimetry platform for TRT. This platform calculates patient-specific dose distributions based on serial CT/PET or CT/SPECT images acquired after injection of the TRT agent. In this work, S-values and specific absorbed fractions (SAFs) were calculated using this platform and benchmarked against reference values. Methods: S-values for 1, 10, 100, and 1000g spherical tumors with uniform activity distributions of I-124, I-125, I-131, F-18, and Ra-223 were calculated and compared to OLINDA/EXM reference values. SAFs for monoenergetic photons of 0.01, 0.1, and 1 MeV and S factors for monoenergetic electrons of 0.935 MeV were calculated for the liver, kidneys, lungs, pancreas, spleen, and adrenals in the Zubal Phantom and compared with previously published values. Sufficient particles were simulated to keep the voxel statistical uncertainty below 5%. Results: The calculated spherical S-values agreed within a few percent of reference data from OLINDA/EXM for each radionuclide and sphere size. The comparison of photon SAFs and electron S-values with previously published values showed good agreement with the previously published values. The S-values and SAFs of the source organs agreed within 1%. Conclusion: Our platform has been benchmarked against reference values for a variety of radionuclides and over a wide range of energies and tumor sizes. Therefore, this platform could be used to provide accurate patientspecific dosimetry for use in radiopharmaceutical clinical trials.

60 APPLIED LIFE SCIENCES↗

SU-E-QI-20: A Review of Advanced PET and CT Image Features for the Evaluation of Tumor Response

Purpose: To review the literature in using quantitative PET and CT image features for the evaluation of tumor response. Methods: We reviewed and summarized more than fifty papers that use advanced, quantitative PET/CT image features for the evaluation of tumor response. We also discussed future works on extracting disease-specific features, combining multiple and complementary features in response modeling, delineating tumor in multimodality images, and exploring biological explanations of these advanced features. Results: Advanced PET image features considering spatial information, such as tumor volume, tumor shape, total glycolytic volume, histogram distance, and texture features (characterizing spatial distribution of FDG uptake) have been found more informative than the traditional SUVmax for the prediction of tumor response. Advanced CT features, including volumetric, attenuation, morphologic, structure, and texture descriptors, have also been found advantage over the traditional RECIST and WHO criteria in certain tumor types. Conclusions: Advanced, quantitative FDG PET/CT image features have been shown promising for the evaluation of tumor response. With the emerging multi-modality imaging performed at multiple time points for each patient, it becomes more important to analyze the serial images quantitatively, select and combine both complementary and contradictory information from various sources, for accurate and personalized evaluation of tumor response to therapy.

60 APPLIED LIFE SCIENCES↗