Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scan report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Measurement of minority-carrier drift mobility in solar cells using a modulated electron beam

A determination of diffusivity on solar cells is here reported which utilizes a one dimensional treatment of diffusion under sinusoidal excitation. An intensity-modulated beam of a scanning electron microscope was used as a source of excitation. The beam was injected into the rear of the cell, and the modulated component of the induced terminal current was recovered phase sensitively. A Faraday cup to measure the modulated component of beam current was mounted next to the sample, and connected to the same electronics. A step up transformer and preamplifier were mounted on the sample holder. Beam currents on the order of 400-pA were used in order to minimize effects of high injection. The beam voltage was 34-kV, and the cell bias was kept at 0-V.

Othmer, S.↗

PKS 2155-304 relativistically beamed synchrotron radiation from BL LAC object

The newly discovered BL Lacertae object, PKS 2155-304, was observed with the medium and high intensity energy detectors of the HEAO-1 A2 experiment. The variability by a factor of two in less than a day reported by Snyder, et al (1979) is confirmed. Two spectra, obtained a year apart, while the satellite was in scanning mode, are well fit by simple power laws with energy spectral index alpha sub 1 equals approximately 1.4. A third spectrum, of higher statistical quality, obtained while the satellite was pointed at its source, has has two components. An acceptable fit was obtained using a two power law model, with indices alpha sub 1 equals 2.0 (+1.2, -0.6) and alpha sub 2 equals -1.5 (+1.5, -2.3). An interpretation of the overall spectrum from radio through X-rays in terms of a synchrotron self-Compton model gives a good description of the data if allowance is made for relativistic beaming. Thus, from a consideration of the spectrum, combined with an estimate of the size of the source, the presence of jets is inferred without their observation.

Urry, C. M.↗

Hubble space telescope component qualification utilizing a residual gas analyzer

An approach is described for integrating an automated residual gas analyzer (RGA) into the thermal vacuum outgas process. The RGA has the capability of detailed analysis over a 200 amu range with monitoring of each peak as the test progresses. The NASA criterion of either a 50% reduction of each peak over 44 amu or less than an 0.1% amplitude of the 28 amu base peak for all amu's above 44 amu is satisfied. A computer sorts, reports which peaks do not satisfy the criterion, and reports test completion. The computer plots amplitudes of all the peaks from 1 amu through 200 amu for each scan. This RGA real time approach is unique in that it provides sufficient detail to highlight a problem as it occurs. By comparison, a quartz crystal microbalance (QCM) or a thermoelectric quartz crystal microbalance (TQCM) indicates to the operator when changes occur, but not what has happened. Optical witness samples indicate whether a test was satisfactory within a few days after the test was completed.

Westfall, A. H.↗

Production of global sea surface temperature fields for the Jet Propulsion Laboratory workshop comparisons

Sea surface temperature (SST) is measured from space by the advanced very high resolution radiometer (AVHRR), scanning multichannel microwave radiometer (SMMR), high resolution infrared sounder (HIRS) and VISSR atmospheric sounder (VAS). Typical accuracies have been reported from 0.5 C regionally to 2.0 C on a global basis. To evaluate the accuracy of the satellite-derived sea surface temperatures, a series of three workshops was organized to provide uniform data reduction and analysis. The analytical techniques used to intercompare satellite and in situ measurements are described in detail. Selected results showed the overall average rms errors were in the range 0.5-1.0 C.

Hilland, J. E.↗

Power Electronics Materials and Bonded Interfaces - Reliability and Lifetime

High temperature operation of wide bandgap devices continue to be a challenge for the power electronics packages. Thermal performance and reliability are important factors that determine the viability of a bonded interface for operation at high temperatures. In this presentation, we present the technical approach and key results from the research on sintered silver, transient liquid phase alloy, and polymeric materials. A lifetime prediction model that incorporates the thermomechanical behavior of sintered silver at 200C was developed. The copper-aluminum transient alloy completed 350 thermal cycles from -40C to 200C and little increase in the defect level was observed. In addition to material research, we initiated a time-series analysis on the scanning acoustic microscope images of eutectic solder to explore statistical forecasting methods and machine learning techniques. Initial results that report the accuracy of a few different statistical models are presented.

ADVANCED PROPULSION SYSTEMS↗

Texture evolution as a function of scan strategy and build height in electron beam melted Ti-6Al-4V

Metal additive manufacturing (AM) enables customizable, on-demand parts, allowing for new designs and improved engineering performance. Yet, the ability to control AM metal alloy microstructures (i.e., grain morphology, crystallographic texture, and phase content) is lacking. Furthermore, this work performs corroborative neutron diffraction and large-scale electron backscatter diffraction (EBSD) measurements to assess crystallographic texture in electron beam melted (EBM) Ti-6Al-4V as a function of scan strategy and build height. Texture components for one raster and two spot melt scan strategies were evaluated using a triclinic specimen symmetry to capture all possible texture components, which were found to be considerably different than previously reported values from studies employing orthotropic specimen symmetry. This finding highlights the importance of a standard method and best practice for assessing textures produced by AM.

36 MATERIALS SCIENCE↗

On–Surface Synthesis and Characterization of Acene–Based Nanoribbons Incorporating Four–Membered Rings

A bottom up method for the synthesis of unique tetracene–based nanoribbons, which incorporate cyclobutadiene moieties as linkers between the acene segments, is reported. These structures were achieved through the formal [2+2] cycloaddition reaction of ortho –functionalized tetracene precursor monomers. The formation mechanism and the electronic and magnetic properties of these nanoribbons were comprehensively studied by means of a multitechnique approach. Ultra–high vacuum scanning tunneling microscopy showed the occurrence of metal–coordinated nanostructures at room temperature and their evolution into nanoribbons through formal [2+2] cycloaddition at 475 K. Frequency–shift non–contact atomic force microscopy images clearly proved the presence of bridging cyclobutadiene moieties upon covalent coupling of activated tetracene molecules. Insight into the electronic and vibrational properties of the so–formed ribbons was obtained by scanning tunneling microscopy, Raman spectroscopy, and theoretical calculations. Magnetic properties were addressed from a computational point of view, allowing us to propose promising candidates to magnetic acene–based ribbons incorporating four–membered rings. Here, the reported findings will increase the understanding and availability of new graphene–based nanoribbons with high potential in future spintronics.

36 MATERIALS SCIENCE↗

Advances and challenges in cryo ptychography at the Advanced Photon Source

Ptychography has emerged as a nondestructive tool to quantitatively study extended samples at a high spatial resolution. In this manuscript, we report on recent developments from our team. We have combined cryo ptychography and fluorescence microscopy to provide simultaneous views of ultrastructure and elemental composition, we have developed multi-GPU parallel computation to speed up ptychographic reconstructions, and we have implemented fly-scan ptychography to allow for faster data acquisition. We conclude with a discussion of future challenges in high-resolution 3D ptychography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nova Ophiuchi 1977 - An X-ray nova

This letter reports the observation by the HEAO 1 satellite experiments of the X-ray nova in Ophiuchus discovered by Kaluzienski and Holt (1977), which is designated H1705-25. The SAO/MIT scanning modulation collimator has been used in conjunction with the NRL large-area sky survey to give two possible positions for the X-ray nova, each having errors of 0.3 by 1.8 arcmin. The discovery of a 16.5-magnitude optical nova (Nova Ophiuchi 1977) in one of the error boxes is reported, and the X-ray source is identified with the optical nova. The object is classified as being of the A0620-00 and A1524-61 type; i.e., a low-mass binary system.

Griffiths, R. E.↗

Leaky ribosomal scanning enables tunable translation of bicistronic ORFs in green algae

Advances in sequencing technology have unveiled examples of nucleus-encoded polycistrons, once considered rare. Exclusively polycistronic transcripts are prevalent in green algae, although the mechanism by which multiple polypeptides are translated from a single transcript is unknown. Here, we used bioinformatic and in vivo mutational analyses to evaluate competing mechanistic models for translation of bicistronic mRNAs in green algae. High-confidence manually curated datasets of bicistronic loci from two divergent green algae, Chlamydomonas reinhardtii and Auxenochlorella protothecoides, revealed a preference for weak Kozak-like sequences for ORF 1 and an underrepresentation of potential initiation codons before the ORF 2 start codon, which are suitable conditions for leaky ribosome scanning to allow ORF 2 translation. We used mutational analysis in A. protothecoides to test the mechanism. In vivo manipulation of the ORF 1 Kozak-like sequence and start codon altered reporter expression at ORF 2, with a weaker Kozak-like sequence enhancing expression and a stronger one diminishing it. A synthetic bicistronic dual reporter demonstrated inversely adjustable activity of green fluorescent protein expressed from ORF 1 and luciferase from ORF 2, depending on the strength of the ORF 1 Kozak-like sequence. Our findings demonstrate that translation of multiple ORFs in green algal bicistronic transcripts is consistent with episodic leaky scanning of ORF 1 to allow translation at ORF 2. This work has implications for the potential functionality of upstream open reading frames (uORFs) found across eukaryotic genomes and for transgene expression in synthetic biology applications.

59 BASIC BIOLOGICAL SCIENCES↗

Reference radiochromic film dosimetry in kilovoltage photon beams during CBCT image acquisition

Purpose: A common approach for dose assessment during cone beam computed tomography (CBCT) acquisition is to use thermoluminescent detectors for skin dose measurements (on patients or phantoms) or ionization chamber (in phantoms) for body dose measurements. However, the benefits of a daily CBCT image acquisition such as margin reduction in planning target volume and the image quality must be weighted against the extra dose received during CBCT acquisitions. Methods: The authors describe a two-dimensional reference dosimetry technique for measuring dose from CBCT scans using the on-board imaging system on a Varian Clinac-iX linear accelerator that employs the XR-QA radiochromic film model, specifically designed for dose measurements at low energy photons. The CBCT dose measurements were performed for three different body regions (head and neck, pelvis, and thorax) using humanoid Rando phantom. Results: The authors report on both surface dose and dose profiles measurements during clinical CBCT procedures carried out on a humanoid Rando phantom. Our measurements show that the surface doses per CBCT scan can range anywhere between 0.1 and 4.7 cGy, with the lowest surface dose observed in the head and neck region, while the highest surface dose was observed for the Pelvis spot light CBCT protocol in the pelvic region, on the posterior side of the Rando phantom. The authors also present results of the uncertainty analysis of our XR-QA radiochromic film dosimetry system. Conclusions: Radiochromic film dosimetry protocol described in this work was used to perform dose measurements during CBCT acquisitions with the one-sigma dose measurement uncertainty of up to 3% for doses above 1 cGy. Our protocol is based on film exposure calibration in terms of ''air kerma in air,'' which simplifies both the calibration procedure and reference dosimetry measurements. The results from a full Monte Carlo investigation of the dose conversion of measured XR-QA film dose at the surface into dose to water (or water kerma) at the surface of the phantom indicate that, for typical beam qualities used in CBCT, this conversion can be approximated by simple mass-energy absorption coefficient ratios water-to-air.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-G-206-06: Analytic Dose Function for CT Scans in Infinite Cylinders as a Function of Scan Length and Cylinder Radius

Purpose: The radiation dose absorbed at a particular radius ρ within the central plane of a long cylinder following a CT scan is a function of the length of the scan L and the cylinder radius R along with kVp and cylinder composition. An analytic function was created that that not only expresses these dependencies but is integrable in closed form over the area of the central plane. This feature facilitates explicit calculation of the planar average dose. The “approach to equilibrium” h(L) discussed in the TG111 report is seamlessly included in this function. Methods: For a cylindrically symmetric radiation field, Monte Carlo calculations were performed to compute the dose distribution to long polyethylene cylinders for scans of varying L for cylinders ranging in radius from 5 to 20 cm. The function was developed from the resultant Monte Carlo data. In addition, the function was successfully fit to data taken from measurements on the 30 cm diameter ICRU/TG200 phantom using a real-time dosimeter. Results: Symmetry and continuity dictate a local extremum at the center which is a minimum for the larger sizes. There are competing effects as the beam penetrates the cylinder from the outside: attenuation, resulting in a decrease; scatter, abruptly increasing at the circumference. This competition may result in an absolute maximum between the center and outer edge leading to a “gull wing” shape for the radial dependence. For the smallest cylinders, scatter may dominate to the extent that there is an absolute maximum at the center. Conclusion: An integrable, analytic function has been developed that provides the radial dependency of dose for the central plane of a scan of length L for cylinders of varying diameter. Equivalently, we have developed h(L,R,ρ).

60 APPLIED LIFE SCIENCES↗

Large scale ZnTe nanostructures on polymer micro patterns via capillary force photolithography

A novel approach to prepare micro patterns ZnTe nanostructures on Si (100) substrate using thermal evaporation is proposed by capillary Force Lithography (CFL) technique on a self-assembled sacrificial Polystyrene mask. Polystyrene thin films on Si substrates are used to fabricate surface micro-relief patterns. ZnTe nanoparticles have been deposited by thermal evaporation method. The deposited ZnTe nanoparticles properties were assessed by Atomic Force Microscope (AFM), Scanning Electron Microscope (SEM). SEM studies indicated that the particles are uniform in size and shape, well dispersed and spherical in shape. This study reports the micro-arrays of ZnTe nanoparticles on a self-assembled sacrificial PS mask using a capillary flow photolithography process which showed excellent, morphological properties which can be used in photovoltaic devices for anti-reflection applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SEM Characterization of an Irradiated Monolithic U-10Mo Fuel Plate

Results of scanning electron microscopy (SEM) characterization of irradiated U-7Mo dispersion fuel plates with differing amounts of matrix Si have been reported. However, to date, no results of SEM analysis of irradiated U-Mo monolithic fuel plates have been reported. This paper describes the first SEM characterization results for an irradiated monolithic U-10Mo fuel plate. Two samples from this fuel plate were characterized. One sample was produced from the low-flux side of the fuel plate, and another was produced at the high-flux side of the fuel plate. This characterization focused on the microstructural features present at the U-10Mo foil/cladding interface, particularly the interaction zone that had developed during fabrication and irradiation. In addition, the microstructure of the foil itself was investigated, along with the morphology of the observed fission gas bubbles. It was observed that a Si-rich interaction layer was present at the U-10Mo foil/cladding interface that exhibited relatively good irradiation behavior, and within the U-10Mo foil the microstructural features differed in some respects from what is typically seen in the U-Mo powders of an irradiated dispersion fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rapid synthesis of barium titanate microcubes using composite-hydroxides-mediated avenue

Highlights: • Barium titanate oxides microcubes can be synthesized within 1 min. • Composite-hydroxides-mediated strategy provided a possible large scale production. • BST obtained in the strategy showed fairly good crystallinity and tetragonality. - Abstract: This paper reports the rapid synthesis of barium titanate (BaTiO{sub 3}, BTO) microcubes via composite-hydroxides-mediated reaction within 1 min. X-ray diffraction (XRD), scanning electron microscopy (SEM) and energy dispersion spectrum (EDS) results confirmed both cubic and tetragonal lattices in the sample and the uniform microcubes with an average size of 1 μm. Ultraviolet–visible (UV–vis) spectrum indicated that the band gap of the BTO powder was 3.05 eV. Ferroelectric polarization vs. electric field (P–E) tests showed that the ferroelectric domains had formed in the as-synthesized BTO microcubes and sintered ceramics. BTO ceramics sintered at 1100 °C for 3 h showed fairly good tetragonality and possessed a maximum polarization of 0.21 μC/cm{sup 2}, indicating that the sintering temperature for the BTO powders prepared via this method was relatively low. The process and equipment reported herein provided a potential method for the rapid synthesis of titanate based perovskites.

36 MATERIALS SCIENCE↗

Studies of surface adsorbate electronic structure and femtochemistry at the fundamental length and time scales. Final report

The electronic structure and ultrafast (10-15 s-femtosecond timescale) electron dynamics were investigated for clean and atom/molecule covered metal surfaces. The studies were performed by scanning tunneling microscopy (STM) to measure the structure of adsorbed atoms and molecules on metal surfaces, and to investigate their electronic properties. The electronic structure of the observed molecular networks was calculated by electronic structure theory in collaboration with Prof. Jin Zhao, who is a long-time collaborator, a Professor at the University of Science and Technology of China, and holds an Adjunct Professorship at the University of Pittsburgh. We also investigated the electronic properties of C60 molecules when they are templated by corrugated black phosphorous surfaces. We found unexpected charge delocalization that is enabled by the templating. This research was done in collaboration with Professor Min Feng at the Wuhan University, and who also holds an Adjunct Professorship at the University of Pittsburgh. Moreover, the electronic structure and electron dynamics in metal surfaces were investigated by time-resolved photoemission electron spectroscopy. The focus of ultrafast spectroscopy has been on the plasmonic response of silver surfaces. One direction has been to develop multidimensional (energy, momentum, and time) photoelectron spectroscopy of the coherent response of solid surfaces. This method was applied to study the collective electron excitations known generally as plasmons, which screen optical fields from penetration into metals. Although this collective response has been known for more than 60 years and is used extensively to deposit optical energy into metals, how this happens is poorly known. We investigated the plasmonic response of silver at the point where the dielectric response passes through zero and bulk plasmon is excited by light. We discovered that the plasmon excitation decays by exciting electrons from the Fermi level of a metal, which is contrary to what is believed in the plasmonic science community. This research has been performed in collaboration with Dr. Marcel Reutzel, who was a postdoctoral fellow working on this research at the University of Pittsburgh, and now has a faculty position at the University of Göttingen in Germany. Prof. Branko Gumhalter from the Institute of Physics in Zagreb contributed on the theory of plasmonic decay processes. Furthermore, we investigated the Floquet engineering of electronic bands in metals leading to multiphoton photoemission and above threshold photoemission. Finally, we demonstrated that it is possible to change the electronic structure of metals by application of optical fields. Our studies indicated that this happens on subfemtosecond time scale and could potentially be used in ultrafast information processing and quantum computation. Related document information

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ARMing the Edge: Demonstration of Edge Computing Field Campaign Report

Edge computing enables “next-to-instrument” control and intelligent data volume reduction and the potential for autonomous, adaptive measurement strategies such as for automated control of scan strategies for Doppler lidar (DL). Instruments with narrow bandwidth connections (e.g., ship and remote sites) can do scene determination and save phenomenon-appropriate data. For example, Doppler spectrum can be saved when clouds are detected by the instrument or automatic moment detection can take place in camera images and only preserve spectrum when non-monomodal spectra are detected. Automated control at the edge involves changing the sampling (temporal or scanning strategy) of an instrument to suit the phenomena both present and being studied (Jackson et al. 2020). Both data processing and instrument control introduces the possibility of a software-defined instrument.

54 ENVIRONMENTAL SCIENCES↗

Development of State of the Art Solid State Lasers for Altimetry and other LIDAR Applications

This report describes work performed and research accomplished through the end of 1997. During this time period, we have designed and fabricated two lasers for flight LIDAR applications to medium altitudes (Laser Vegetation Imaging System designs LVIS 1 and LVIS 2), designed one earth orbiting LIDAR transmitter (VCL-Alt), and continued work on a high rep-rate LIDAR laser (Raster Scanned Altimeter, RASCAL). Additionally, a 'White Paper' was prepared which evaluates the current state of the art of Nd:YAG lasers and projects efficiencies to the year 2004. This report is attached as Appendix 1 of this report.

Kay, Richard B.↗