Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ramping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Fort Erie On-Demand Transit Case Study

Rural and smaller-sized communities in North America face unique mobility challenges due to their low population density, lower public transit spending per capita compared to major cities, and a high reliance on private vehicles. In recent years, communities such as Fort Erie, Ontario have restructured or advanced their public transit systems using on-demand services. Fort Erie is a relatively sparsely populated region of 32,901 residents, spread across a land area of 166 square kilometers (64 square miles), for an average population density of 193 residents per square kilometer (500 per square mile). In October 2021, the town implemented a mobility-on-demand system integrated with smartphone software to replace its fixed-route community bus system, which consisted of four buses with three routes, each with a roughly one-hour, one way loop. The new service utilizes a fleet of six minivans, two of which are retrofitted with wheelchair-accessible ramps. The system may require that a passenger requesting a standard van walk up to 400 meters (a quarter mile) to their pickup location to optimize vehicle routing while providing origin-to-destination service. The on-demand system proved effective in providing service, eclipsing pre-pandemic ridership by 40%, decreasing greenhouse gas emissions per ride by 63%, and decreasing the cost per ride to the town by 29%. This report documents both the previous system and the new system in terms of routes, ridership, costs, fuel, and other notable system parameters. This work is part of an ongoing series of case studies on providing small communities with on-demand, right-sized vehicle service coupled with a smartphone application.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Techno-Economic and Deployment Analysis of Fossil Fuel-Based Power Generation with Integrated Energy Storage

Most existing coal-fired power plants were designed for sustained operation at full load to maximize efficiency, reliability, and revenues. Depending on plant type and design, these plants can adjust output within a fixed range in response to plant or market conditions. The need for flexibility driven by increased penetration of variable and non-dispatchable power generation such as wind and solar is shifting traditional mission profile of thermoelectric power plants in three ways: more frequent shutdowns when market or grid conditions warrant, more aggressive load ramp rates (rate of output change), and lower minimum sustainable load, which provides a wider operating range and helps avoid costly plant shutdowns. The recent studies have shown that flexibility of a coal-fired power plant can be improved by the energy storage. The objective of this project was to analyze a set of energy storage options (technologies) and determine their impact on flexibility and economics of a representative coal-fired power plant. The effect of five Energy Storage Systems (ESSs) integrated with a coal power plant on plant flexibility and economics was investigated in this study. The results obtained in this project and presented in this report showed that ESS integrated with a thermal power plant improves plant flexibility and participation in the Energy and Ancillary Services markets and also improves plant financial performance.

20 FOSSIL-FUELED POWER PLANTS↗

A Real-Time Operations Manual for the IEEE 118 Bus Transmission Model

This document presents a sample operations manual for the IEEE 118 Bus Model, which is a synthetic test case developed in 1962 from a section of the transmission grid operated by American Electric Power (AEP). The model is one of the most used synthetic test cases for development of power system applications and is referenced by over 9000 papers. However, the model lacks any context for use with real-time energy management system (EMS) applications, including common considerations, such as generator ramp rates, reactive capabilities, operating limits, and other information typically used by power system operators for real-time decision making. This manual divides the IEEE 118 Bus Model into three operating areas, defines various operating limits, and sets recommended operating procedures for responding to a few types of emergency operating conditions. The manual can be used in support of a wide variety of human-in-the-loop evaluation methodologies for new advanced power applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid Heavy Duty Diesel Powertrain for Off-Road Applications (Final Technical/Scientific Report)

In this program, a heavy-duty hybrid powersystem, consisting of a 30% downsized diesel engine and a front-end accessory drive (FEAD) incorporating a high-speed flywheel (HSFW) energy storage system, a mechanical-drive turbocharger (SuperTurbo), and motor-generator units (MGU) was developed and demonstrated. The high efficiency core 13L engine coupled with the hybrid elements was physically validated across various off-road machine and transient work cycles with the ultimate goal of demonstrating 17% efficiency improvement with equivalent transient response as the 18L diesel engine this concept powersystem would replace. The project culminated in a physical demonstration of the high-efficiency powersystem in a high-capability test cell with the engine, all the hybrid devices, controls, and required performance and emissions measurements. Based on the combination of physical validation and rigorous system simulation, the following program conclusions may be drawn: (1) The developed hybrid H2D2 powersystem demonstrated a range of efficiency improvement of 10.5 - 25.6%, with a midpoint of 17.9%; (2) Transient load response on; (3) The HSFW system was validated to achieve peak assisting of 110kW at 12,000 Nm/sec ramp rates; (4) The powersystem was validated to be capable of meeting U.S. EPA Tier 4 Final off-road emissions through transient NRTC testing; (5) A Total Cost of Ownership (TCO) analysis and found that the core 13L engine would pay back immediately (adoption of start/stop would pay back in less than one year, and the full hybrid system payback was three years.)

33 ADVANCED PROPULSION SYSTEMS↗

Application of FARM to an IES scenario within the FORCE ecosystem

The FARM (Feasible Actuator Range Modifier) software module is a component of the RAVEN-based FORCE framework for analysis of Integrated Energy Systems (IES). FARM supports the HERON software module in the evaluation of the optimal dispatch by evaluating feasible set-points for the different IES unit components. Set-points are required to satisfy limits on both production variables (i.e., the variables to be optimized such as the electrical power, the hydrogen production rate, etc.) and process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.). This problem is addressed by adopting a two-stage approach. First, the HERON power dispatcher determines set-points that meet the constraints on the former variables (e.g., power levels and power ramp rate limits). These constraints are called explicit constraints. Then, FARM adjusts these set-points to ensure the respect of the limits on the latter variables given the knowledge of the system physics acquired through machine learning algorithms. These constraints are called implicit constraints. From this standpoint, FARM constitutes a bridge between the HERON power dispatcher that adopts a simplified description of the IES unit (low-resolution physics) and the HYBRID high-fidelity models (high-resolution physics). The original version of the FARM software module (FARM-Alpha) was released by Argonne National Laboratory in January 2021. In the latest version of the code released in July 2022 (FARM-Delta), the Reference Governor (RG) algorithm was upgraded to a Multi-Input Multi-Output version from its original Single-Input Single-Output form. The RG algorithm acts to enforce constraints. With this improvement an IES unit is now treated as a single dynamic system from the standpoint of control. The crosstalk among components in an IES unit is now fully considered thereby ensuring a true optimization is obtained for those units that have multiple set-points. In this report, the capabilities of FARM-Delta operating within the FORCE ecosystem are demonstrated for an IES test case. The specific configuration of IES unit for this case was selected by the IES team with consultation from the Advanced Reactor IES Expert Group. A full TEA analysis that invoked HERON, HYBRID, FARM, and RAVEN was performed and serves to demonstrate how the latest modification to FARM algorithms (i.e., state variable selection, state-space matrices derivation, set-point verification) can shape setpoints that might otherwise compromise the health of equipment through accelerated wear and tear. In this specific test case, it was demonstrated that these algorithms ensure a more efficient utilization of steam resources to be shared by two different subsystems, namely Balance of Plant (BOP) and High-Temperature Steam Electrolysis (HTSE). Finally, some code improvements that can further enhance the user-friendliness are suggested.

97 MATHEMATICS AND COMPUTING↗

Gasification of Coal and Biomass: The Route to Net-Negative-Carbon Power and Hydrogen

One promising process that is a candidate for meeting the goals of the US Department of Energy’s 21st Century Power Plant initiative is to gasify a mixture of coal and biomass to yield a syngas, which can have CO2 removed and then be used to produce hydrogen as well as an off-gas that can be used to flexibly produce power. This concept would overall be carbon net-negative and readily meet the 21st Century Power Plant initiative targets of smaller scale MW generation, high ramp rates and turndown, feedstock flexibility, and high efficiency—at a reasonable cost. Moreover, adding the large-scale production of “ultra-green” hydrogen yields a system tailored for the coming hydrogen economy, providing long-term energy storage and an attractive co-product for sale. The objective of the work being led by the Electric Power Research Institute, Inc. (EPRI), with support by Bechtel Corporation (Bechtel), Gas Technology Institute (GTI), Hamilton Mauer International, Inc. (HMI), Nebraska Public Power District (NPPD), NexantECA, Inc. (Nexant), and Wärtsilä, is to perform a front-end design and engineering (FEED) study on an oxygen-blown gasification system coupled with water-gas shift, pre-combustion CO2 capture, and pressure-swing adsorption working off a coal/biomass mix to yield high-purity hydrogen and a fuel off-gas that can generate power. Several designs are being considered that will be capable of producing 50 MW net from a flexible generator, over 8500 kg/hr of hydrogen, and net-negative CO2 emissions, at an efficiency of 50% net HHV. The plant would be hosted at an NPPD site, where opportunities for enhanced oil recovery and sequestration have been investigated and the need for low-carbon power and hydrogen is imminent. The principal biomass to be used is corn stover—prevalent in Nebraska where the plant will be located—mixed with Powder River Basin (PRB) coal, necessitating a gasifier that can use this feedstock and be flexible to allow other types. Waste plastics will also be reviewed for use. Two oxygen-blown gasifiers have been identified as candidates that have done testing with biomass including corn stover: the GTI gasifier—a high-pressure, fluidized-bed type—and HMI’s, a lower pressure moving-bed type. Both have relative advantages that were investigated in the Phase I design study, with a resultant down select of one system for which the FEED will be performed in Phase II. The technical tasks for the project are: • Design Development: Completion of design activities necessary to provide inputs for the FEED study. Multiple design cases will be assessed with the selection of the optimal one for the FEED. • Investment Case Preparation: Development of the draft investment case for the proposed process with business cases performed for the proposed host site and two other locations. • Host Site Selection: Evaluation of the two potential host sites within NPPD’s portfolio to select the preferred candidate based on technical, economic, and environmental considerations. • Environmental Information Volume (EIV) Development: Completion of the EIV for the host site. • FEED Study: Completion of a FEED study based on the design selected in Phase I. A Greenhouse Gas Life Cycle Analysis will also be performed for the process. • Update Investment Case: Finalization of the investment case based on findings from the FEED. The advantages of the proposed project are significant. Having an engaged U.S. power utility willing to provide a host site that will produce energy from coal plus a deep and experienced team is critical; the process meets all the goals of DOE’s 21st Century Power Plant initiative at an estimated total plant cost of ~$880M and a production cost of hydrogen of ~$2/kg-H2 while producing net-negative carbon power. If developed, this process has real commercial potential in the United States—supported by EPRI’s initial review of the considerable interest from selected U.S. utilities—and elsewhere around the globe. The process has fewer environmental hurdles compared to other concepts, lowering regulatory and protest risks—providing a pathway to preserving the viability of a critical indigenous energy source by transforming its use to match a changing world. This presentation outlines the motivation for the effort, summarizes project plans, work completed to date, results of the Phase I effort and, and detailed work scope for the remainder of the project in the Phase II FEED effort.

01 COAL, LIGNITE, AND PEAT↗

An Integrated Paradigm for the Management of Delivery Risk in Electricity Markets: From Batteries to Insurance and Beyond [Slides]

In wholesale electricity markets today, flexibility from a limited number of distributed energy resources (DERs) is offered daily, and the value of flexibility is not yet recognized for economic hedging of delivery risk. Under a three-year project funded by the ARPA-E PERFORM program, a collaborative team is working towards developing an integrated risk management framework that will leverage flexibility from distributed and bulk resources to cost-effectively and reliably manage delivery risk of intermittent resources. Two concepts are at the core of the proposed integrated risk management framework: (A) flexibility options, which are a novel type of options and enable wholesale electricity market participants to hedge uncertainty by buying flexibility. (B) DER flexibility scores, which provide a way for utilities or aggregators to classify assets in groups with different likelihood of delivering contracted flexibility. This report presentation will focus on the proposed ISO-product "flexibility options," which is complementary to ramp and other products being introduced by ISOs/RTOs to manage net load uncertainties. Participating resources with imbalance risk can buy flexibility options to hedge their production, whereas grid-connected resources that can provide physical flexibility can offer flexibility options. We will present basics of the formulation for a day-ahead ISO market that matches buyers and sellers of this hedge in coordination with existing capabilities to schedule energy and ancillary services, and outline how their settlements mitigate the impact of imbalance risk.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cost and Performance Baseline for Fossil Energy Plants, Volume 5: Natural Gas Electricity Generating Units for Flexible Operation

To address the data needs of energy system designers and to serve as a baseline for research and development, NETL has carried out a study to characterize the flexibility attributes - both performance and cost - of nine common commercial natural gas-fueled electricity generating units. The intermittent output of low-carbon, renewable power generation sources such as wind and solar create challenges to grid stability and reliability. Fossil-fueled power generation technologies are currently used to provide reliable, on-demand power during periods of reduced renewable output. Dispatchable generators must be able to accommodate increasing renewable generation as the nation pursues the Administration’s target of a decarbonized energy sector by 2035. As energy system experts seek to identify least-cost approaches to decarbonization, accurate cost and performance data characterizing dispatchable fossil generators that operate flexibly, at capacity factors that have been declining over time, and are needed to inform models for capacity expansion. Furthermore, these technologies continue to be a significant source of carbon dioxide emissions, providing the impetus for research and development, including the advancement and potential incorporation of carbon capture technologies. This study characterizes the cost and performance of select state-of-the-art natural gas-fueled power generation technologies: reciprocating internal combustion engines (RICE), simple cycle combustion turbines, and natural gas combined cycles (NGCC). An emphasis is placed on flexibility characteristics, such as part-load heat rate, ramp rates, start up times, and start up costs.

03 NATURAL GAS↗

OPALCO - Decatur Island Solar and Energy Storage Project: An Assessment of Battery Technical Performance

Orcas Power & Light Cooperative (OPALCO) is a member-owned, nonprofit cooperative utility that provides energy services to approximately 11,200 customers across 20 islands in San Juan County, Washington. OPALCO’s mostly hydroelectric power is generated by Bonneville Power Administration and delivered to the islands by submarine cables. In 2016, as part of the second round of funding from the Washington state Clean Energy Fund, OPALCO received a $1 million matching grant to support a project that deployed a 504-kW LG community photovoltaic (PV) system in combination with a 1 MW/2 MWh lithium-iron-phosphate battery energy storage system (BESS) on Decatur Island, Washington. The Decatur Island Substation is essential to ensuring reliable energy for the residents of the San Juan Islands as it is the point of interconnection with the mainland transmission system. The BESS, in combination with the community solar array, will deliver an innovative method to both defer the costly upgrade of the transmission system and allow for other high-value applications intended to benefit the utility and its customers. In 2018, Pacific Northwest National Laboratory (PNNL) completed a preliminary economic assessment for several identified use cases in collaboration with OPALCO. Between August 2021 and May 2022, extensive testing was conducted, and the results were used to assess the technical performance of the BESS subjected to actual field operations. Both reference performance and use case tests were performed: (a) Reference performance tests assess the general technical capabilities of the BESS, such as energy capacity, round-trip efficiency (RTE), ramp rate, and signal tracking capability. These are the first tests performed (baseline) and are repeated after use case tests (post cycle). A standardized U.S. Department of Energy (DOE) energy storage performance protocol was used to characterize the BESS, including representative duty cycle profiles, test procedure guidance, and calculation guidance for determining key characteristics. (b) Use case tests examine the performance of the BESS for specific use cases using duty cycles developed by PNNL in collaboration with OPALCO. Four use cases were selected for testing: 1) demand charge reduction, 2) load shaping, 3) outage mitigation, and 4) transmission deferral. The use case duty cycles were developed based on utility and site-specific characteristics in addition to the technical characteristics and physical capabilities of the BESS. Use case tests were performed between the baseline and post cycle tests. This report describes the BESS and its components, presents testing and performance analysis results, and shares key insights and lessons learned from this project. Outcomes of the tests and analyses will help OPALCO understand the performance of the Decatur Island BESS in its current state and design appropriate operational strategies for this and other BESSs over the long term.

14 SOLAR ENERGY↗

Validation of MFUEL Metal Fuel Performance Models of SAS4A/SASSYS-1

The fuel characterization models of SAS4A/SASSYS-1 (SAS) have recently been extended to include a new U-Pu-Zr metal fuel model, MFUEL. MFUEL is equipped with mechanistic physics based models to predict the pre-transient characterization and transient response of metal fuel, with emphasis on fuel melting, cladding failure, and the metal fuel’s impact on core reactivity. The MFUEL model will be available in the full version of SAS4A/SASSYS-1 5.7, which is scheduled to be released in June 2023. Fast reactor fuel pins that operated in EBR-II and FFTF with low smear density U-Zr and U-Pu-Zr metal fuels and irradiation resistant ferritic-martensitic cladding showed significant advantages in achieving high burnups and assuring inherent safety characteristics during anticipated transients, design basis events, and beyond design basis events. For safety analysis, a fuel performance model must be able to predict (1) Fuel pin mechanics and compositional and dimensional changes, (2) Clad failure, and (3) Fuel pin thermal resistance. Achieving these high level goals accurately is strongly related to the model performance of individual physical processes taking place within a fuel pin during its lifetime. Metal fuels typically operate above the mid-point temperature of melting during normal, as well as off-normal, conditions. At these elevated temperatures, the availability of thermal activation provides a driving force for various diffusional processes leading to complex phase transformations, micro-structure evolution, significant amounts of fuel swelling, interconnected porosity formation, excessive amounts of fission gas release, and fuel clad chemical interactions. Clad failure in fast reactors primarily occurs as a result of creep rupture augmented by clad wastage formation. The reaction is driven by thermal creep induced dislocation motion, grain boundary cavity nucleation, growth and breakup of grain boundaries. The high level complexity and limited available data requires introducing physics-based modeling approaches to gain extrapolation ability and sensitivity with respect to various conditions. The objective of this report is to perform validation of MFUEL using the experimental data for (1) Normal operation EBR-II fuel behavior, (2) Normal operation PHENIX fuel behavior, (3) HT9 Pressure tube ramp-and-hold creep rupture tests, (4) Whole Pin Furnace (WPF) creep strain, creep rupture and eutectic tests, (5) Fuel Behavior Test Apparatus (FBTA) eutectic tests, and (6) TREAT M5-7 OverPower tests up to clad failure. Section-2 includes a brief description of the MFUEL models. A detailed description of the MFUEL physics-based, semi-empirical models will be presented in the SAS V 5.7 theory manual. Section-3, 4, and 5 describes the validation effort for the pre-transient irradiation, furnace transients, and TREAT M-Series transients, respectively.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

South Africa’s Appliance Energy Efficiency Standards and Labeling Program

Electricity consumption in South Africa comes with a hefty environmental cost to the society. For every kilowatt-hour (kWh) produced, 1 kilogram (kg) of carbon dioxide (CO 2 ) is emitted, 1.4 liters of water are used, and 0.37 grams of particulate emissions are released in the atmosphere. These environmental implications result from the large share of electricity produced from coal (91 percent in 2015). While planned new capacity will ramp up renewable energy, the integrated resource plan for the country still projects the share of col to be 64 percent in 2030. Energy savings provide environmental benefits as well as economic benefits. Energy efficiency standards and labeling (S&L) programs are a policy measure proven to save energy. Such programs have been implemented in many countries to remove inefficient technologies and transform markets to more efficient technologies. In this study, we describe the methodology, assumptions and results of a stock turnover modeling tool that estimates the energy savings achievable by South Africa’s S&L program in the residential sector. We show that if regulations are passed in 2020 and effective in 2021 for 10 major end-use adopting international standards best practices, 6 terawatt-hours (TWh) will be saved in 2030 and 9.5 TWh will be saved in 2040, representing a CO 2 mitigation of 3.7 megatonnes (Mt) in 2030 and 5.8 Mt in 2040, which will contribute to the South African government’s international engagement in fighting against climate change through its National Determined Contribution (NDC). Additional environmental benefits include saving of 6.5 billion liters of water in 2030, representing approximately 100 liters per capita in 2030. Air quality will also improve, as 4 kilotons (kt) of particulate emissions will be avoided, as well as 4.3 Mt of sulfur oxides (SOx) and 23 kt of nitrogen oxides (NOx) in 2030.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial PACE Project Origination: Leverage Points for Growing the Project Pipeline

Greater use of Commercial Property Assessed Clean Energy (C-PACE) financing within communities where it is enabled will increase energy savings, drive economic development, and result in additional public benefits. Some states with active C-PACE programs have ramped up activity significantly while others have not achieved and sustained a high volume of transactions. This brief details C-PACE project origination trends, barriers, and market practices for state and local government C-PACE program sponsors looking to grow their C-PACE project pipeline.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Assessment of Deploying Advanced Pumped Storage Hydropower Technology in U.S. Electricity Markets

Pumped storage hydropower (PSH) is a type of hydropower technology where energy can be stored and generated by moving water between two reservoirs of differing elevations. In addition to providing 97% of the total utility-scale hydropower storage in the United States, PSH plants have operational characteristics - such as high ramp rates and the ability to provide reserves - that contribute to greater flexibility and reliability of the power grid. New PSH technologies can provide additional flexibility beyond existing, fixed-speed units. With the emergence of high levels of variable renewable energy resources (e.g., wind and solar), energy storage is expected to be crucial to the reliability and reliance of the power grid in a low-carbon future. At diurnal and longer durations, PSH plants have some of the lowest costs per unit of energy, have been proven to be reliable and efficient, are not cycle-limited, and typically have long lives, often exceeding 50 years. The work presented here focuses on a new generation of PSH: ternary PSH and quaternary PSH (together referred to as T/Q-PSH). Given recent experience in Europe, grid operators in the United States and elsewhere are increasingly focusing their attention on T/Q-PSH as a proven, financeable technology that can offer utility-scale, long-duration, fast-acting energy storage capabilities and grid services. T/Q-PSH differs from conventional PSH in that it can provide fast-response ancillary services during both generating and pumping operations. This capability together with fast mode switching times are key attributes that make T/Q-PSH technologies attractive for managing and stabilizing electricity systems with high amounts of variable renewable energy.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY↗

Pits 101: The true meaning of deterrence

Mark Davis (ALDWP-COO) is the Chief Operation Officer for the Associate Laboratory Directorate of Weapons Production, where he focuses on ramping up operations in the Plutonium Facility in support of the directorate's programs, including the plutonium pit mission. Davis has had an accomplished career in the U.S. Navy that has compelled him to inspire those who support our nation's national security through sharing stories of our nation's history and the individuals who have been world-changers. He is passionate not only about our national security mission here at the Lab, but also about ensuring every employee understands that they play a key role in the mission, no matter their day job. In this special edition of the Pits 101 series, Public Affairs sat down with Davis to get his perspective on the meaning of credible and sustainable strategic deterrence, and why it matters today.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Assessment of Nuclear Energy to Support Negative Emission Technologies

The feasibility and performance of nuclear energy coupled with Negative Emission Technology (NET) processes were investigated in this report. Three overarching questions from nuclear NET systems guided this research: which NET would be able to use heat and/or electricity from nuclear power plants (NPPs); what is the performance and cost of a nuclear NET system; and what would be the market outlook for this system? Among the various NETs that are actively being developed, several were found to potentially benefit from coupling with an NPP via (1) large amounts of decarbonized and constant-output electricity; (2) free waste heat or cheap low-temperature heat; or (3) high-temperature heat. NPPs were found to be compatible with Direct Air Capture (DAC) systems, and a detailed techno-economic analysis of coupled NPP&DAC systems was performed. Preliminary analysis also indicated that biomass and water-based NETs are potentially compatible with NPPs, but further work is needed to quantify the performance of these nuclear NET systems. Design and performance analyses were completed for both liquid solvent DAC (L-DAC) and solid sorbent DAC (S-DAC) technologies. A 1.0-GWth NPP coupled with L-DAC and S-DAC was found to be able to capture 12–15 Mt CO 2 /yr and 1.0–1.5 Mt CO 2 /yr, respectively. While the L-DAC process enables much greater CO 2 capture than the S-DAC process when both are sized with a 1 GWth NPP, the NPP&L-DAC system considered also requires >2 GWth natural gas oxy-combustion to reach adequate temperature in the calciner. CO 2 generated from natural gas combustion is also captured as part of the calcination process, in addition to the CO 2 captured from air, resulting in overall CO 2 sequestration of close to 30% more than what is captured from air. The cost of carbon capture calculated with the levelized cost of DAC (LCOD) had a range of $\$170–260$/tCO 2 for NPP&L-DAC systems and a range of $\$650–680$/tCO 2 for NPP&S-DAC systems. For both DAC systems, the NPP provides economic benefit when compared to previous National Energy Technology Laboratory (NETL) studies of non-nuclear DAC systems, leading to reduction of LCOD by 5–7% for L-DAC, and 8–13% for S-DAC. For the NPP&DAC systems, a preliminary market analysis reviewed potential CO 2 market prices and eligibility for incentives. The estimated potential revenues for CO 2 capture (coming from federal incentive, CO 2 commodity markets, or offset market) is in the range of $\$170–979$ tCO 2 , and the results show that because of lower LCOD, the NPP&L-DAC process would be more attractive to a market than the NPP&S-DAC process. The large investment needed for NPP&DAC processes would require long-term certainty of sufficient market size, CO 2 prices, and incentives. Enabling NPPs to ramp DAC operation up or down based on electricity market price is not expected to significantly increase revenues of the NPP&DAC system. This is because the revenues from CO 2 sequestration are required to be very high to justify the deployment and continuous operation of the very expensive DAC technologies. In this analysis, several new research questions were uncovered, and follow-up analyses are recommended for further investigation, including a detailed feasibility study of NPP coupled with other NET systems such as biomass pyrolysis and gasification with carbon capture and storage, and seawater carbon capture.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pulsed High Temperature Superconducting Central Solenoid Model Coil for Plasma Current Drive and Control in High-Field Compact Commercial Fusion Power Plants (CRADA Final Report)

This ARPA-E BETHE project was aimed to design, build and test a fast-ramping HighTemperature Superconducting (HTS) Central Solenoid Model Coil (CSMC) that significantly derisks a full-size HTS Central Solenoid (CS) capable of driving and controlling the plasma current in a compact, high-field, low-cost tokamak power plant. The LBNL objectives and milestones for this project were divided into two distinct tracts: Diagnostics and Quench Simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic Aperture of the PIP-II Accumulator Ring (PAR)

The Proton Improvement Plan-II (PIP-II) will include a superconducting linear accelerator which will accelerate H- ions to 800MeV, at an intensity never seen before. A proposed PIP-II Accumulator Ring (PAR) can reduce the injection losses to the booster, enhance the ramp up of the Long Baseline Neutrino Facility (LBNF) and support experiments in Dark Sector Physics. When the beam is circulating in PAR at its full intensity, it will then be transferred to the Booster via single turn injection. Strong PAR focusing results in larger phase advances, shorter focal lengths and higher machine tunes, which creates robust beam envelope control. Particles will be able to survive modest excursions from the elliptical phase-space trajectories of linear optics, and any loss of particles would be due to reduced dynamic aperture. The values for tunes and chromaticities are flexible and will continue to evolve as the lattice matures. Since there will be non-linear terms impacting the particles’ trajectories, tracking will include realistic magnetic field errors and installation alignment errors to determine the dynamic aperture as a function of the machine tunes. This will allow us to determine the optimum operating point in phase-space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗