At least 1,099 records · Page 61

Electron density and electron temperature measurement in a bi-Maxwellian electron distribution using a derivative method of Langmuir probes

In plasma diagnostics with a single Langmuir probe, the electron temperature T{sub e} is usually obtained from the slope of the logarithm of the electron current or from the electron energy probability functions of current (I)-voltage (V) curve. Recently, Chen [F. F. Chen, Phys. Plasmas 8, 3029 (2001)] suggested a derivative analysis method to obtain T{sub e} by the ratio between the probe current and the derivative of the probe current at a plasma potential where the ion current becomes zero. Based on this method, electron temperatures and electron densities were measured and compared with those from the electron energy distribution function (EEDF) measurement in Maxwellian and bi-Maxwellian electron distribution conditions. In a bi-Maxwellian electron distribution, we found the electron temperature T{sub e} obtained from the method is always lower than the effective temperatures T{sub eff} derived from EEDFs. The theoretical analysis for this is presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A 4 K cryogenic probe for use in magnetic resonance force microscopy experiments

The detailed design of a mechanically detected nuclear magnetic resonance probe using the SPAM (Springiness Preservation by Aligning Magnetization) geometry, operating at 4 K, in vacuum, and a several-Tesla magnetic field is described. The probe head is vibration-isolated well enough from the environment by a three-spring suspension system that the cantilever achieves thermal equilibrium with the environment without the aid of eddy current damping. The probe uses an ultra-soft Si cantilever with a Ni sphere attached to its tip, and magnetic resonance is registered as a change in the resonant frequency of the driven cantilever. The RF system uses frequency sweeps for adiabatic rapid passage using a 500 μm diameter RF coil wound around a sapphire rod. The RF coil and optical fiber of the interferometer used to sense the cantilever's position are both located with respect to the cantilever using a Garbini micropositioner, and the sample stage is mounted on an Attocube nanopositioner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Few-cycle optical probe-pulse for investigation of relativistic laser-plasma interactions

The development of a few-cycle optical probe-pulse for the investigation of laser-plasma interactions driven by a Ti:sapphire, 30 Terawatt (TW) laser system is described. The probe is seeded by a fraction of the driving laser's energy and is spectrally broadened via self-phase modulation in a hollow core fiber filled with a rare gas, then temporally compressed to a few optical cycles via chirped mirrors. Shadowgrams of the laser-driven plasma wave created in relativistic electron acceleration experiments are presented with few-fs temporal resolution, which is shown to be independent of post-interaction spectral filtering of the probe-beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mechanical-plowing-based high-speed patterning on hard material via advanced-control and ultrasonic probe vibration

In this paper, we present a high-speed direct pattern fabrication on hard materials (e.g., a tungsten-coated quartz substrate) via mechanical plowing. Compared to other probe-based nanolithography techniques based on chemical- and/or physical-reactions (e.g., the Dip-pen technique), mechanical plowing is meritorious for its low cost, ease of process control, and capability of working with a wide variety of materials beyond conductive and/or soft materials. However, direct patterning on hard material faces two daunting challenges. First, the patterning throughput is ultimately hindered by the “writing” (plowing) speed, which, in turn, is limited by the adverse effects that can be excited/induced during high-speed, and/or large-range plowing, including the vibrational dynamics of the actuation system (the piezoelectric actuator, the cantilever, and the mechanical fixture connecting the cantilever to the actuator), the dynamic cross-axis coupling between different axes of motion, and the hysteresis and the drift effects related to the piezoelectric actuators. Secondly, it is very challenging to directly pattern on ultra-hard materials via plowing. Even with a diamond probe, the line depth of the pattern via continuous plowing on ultra-hard materials such as tungsten, is still rather small (<0.5 nm), particularly when the “writing” speed becomes high. To overcome these two challenges, we propose to utilize a novel iterative learning control technique to achieve precision tracking of the desired pattern during high-speed, large-range plowing, and introduce ultrasonic vibration of the probe in the normal (vertical) direction during the plowing process to enable direct patterning on ultra hard materials. The proposed approach was implemented to directly fabricate patterns on a mask with tungsten coating and quartz substrate. The experimental results demonstrated that a large-size pattern of four grooves (20 μm in length with 300 nm spacing between lines) can be fabricated at a high speed of ∼5 mm/s, with the line width and the line depth at ∼95 nm and 2 nm, respectively. A fine pattern of the word “NANO” is also fabricated at the speed of ∼5 mm/s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ionization and dissociation dynamics of vinyl bromide probed by femtosecond extreme ultraviolet transient absorption spectroscopy

Strong-field induced ionization and dissociation dynamics of vinyl bromide, CH{sub 2}=CHBr, are probed using femtosecond extreme ultraviolet (XUV) transient absorption spectroscopy. Strong-field ionization is initiated with an intense femtosecond, near infrared (NIR, 775 nm) laser field. Femtosecond XUV pulses covering the photon energy range of 50-72 eV probe the subsequent dynamics by measuring the time-dependent spectroscopic features associated with transitions of the Br (3d) inner-shell electrons to vacancies in molecular and atomic valence orbitals. Spectral signatures are observed for the depletion of neutral C{sub 2}H{sub 3}Br, the formation of C{sub 2}H{sub 3}Br{sup +} ions in their ground (X{sup ~}) and first excited (A{sup ~}) states, the production of C{sub 2}H{sub 3}Br{sup ++} ions, and the appearance of neutral Br ({sup 2}P{sub 3/2}) atoms by dissociative ionization. The formation of free Br ({sup 2}P{sub 3/2}) atoms occurs on a timescale of 330 ± 150 fs. The ionic A{sup ~} state exhibits a time-dependent XUV absorption energy shift of ∼0.4 eV within the time window of the atomic Br formation. The yield of Br atoms correlates with the yield of parent ions in the A{sup ~} state as a function of NIR peak intensity. The observations suggest that a fraction of vibrationally excited C{sub 2}H{sub 3}Br{sup +} (A{sup ~}) ions undergoes intramolecular vibrational energy redistribution followed by the C–Br bond dissociation. The C{sub 2}H{sub 3}Br{sup +} (X{sup ~}) products and the majority of the C{sub 2}H{sub 3}Br{sup ++} ions are relatively stable due to a deeper potential well and a high dissociation barrier, respectively. The results offer powerful new insights about orbital-specific electronic processes in high field ionization, coupled vibrational relaxation and dissociation dynamics, and the correlation of valence hole-state location and dissociation in polyatomic molecules, all probed simultaneously by ultrafast table-top XUV spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of various interpretation methods of the electric probe measurements in inductively coupled Ar and O{sub 2} plasmas

In low-pressure inductively coupled argon and oxygen discharges, the plasma density and electron temperature and the electron energy distribution function (EEDF) were obtained by using a cylindrical electric probe. The plasma densities were determined by various methods to interpret the probe current-voltage characteristic curve: the EEDF integration, the electron saturation current, the ion current at the floating potential, and the orbital-motion-limited (OML) ion current. Quite a good agreement exists between the plasma densities determined by various classical methods. Although the probe technique has some limitation in electronegative plasmas, the plasma densities determined from OML theory compare well with those measured by the ion saturation current at the floating potential in the oxygen discharges. In addition, the EEDFs of inductively coupled Ar and oxygen plasmas are observed to be nearly Maxwellian at the pressure range of 1-40 mTorr.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of plasma impedance probe for measuring electron density and collision frequency in a plasma with spatial and temporal gradients

Numerical simulations and experimental measurements were combined to determine the ability of a plasma impedance probe (PIP) to measure plasma density and electron collision frequency in a plasma containing spatial gradients as well as time-varying oscillations in the plasma density. A PIP is sensitive to collision frequency through the width of the parallel resonance in the Re[Z]-vs.-frequency characteristic, while also being sensitive to electron density through the zero-crossing of the Im[Z]-vs.-frequency characteristic at parallel resonance. Simulations of the probe characteristic in a linear plasma gradient indicated that the broadening of Re[Z] due to the spatial gradient obscured the broadening due to electron collision frequency, preventing a quantitative measurement of the absolute collision frequency for gradients considered in this study. Simulation results also showed that the PIP is sensitive to relative changes in electron collision frequency in a spatial density gradient, but a second broadening effect due to time-varying oscillations made collision frequency measurements impossible. The time-varying oscillations had the effect of causing multiple zero-crossings in Im[Z] at parallel resonance. Results of experiments and simulations indicated that the lowest-frequency zero-crossing represented the lowest plasma density in the oscillations and the highest-frequency zero-crossing represented the highest plasma density in the oscillations, thus the PIP probe was found to be an effective tool to measure both the average plasma density as well as the maximum and minimum densities due to temporal oscillations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development progress of the Materials Analysis and Particle Probe

The Materials Analysis and Particle Probe (MAPP) is a compact in vacuo surface science diagnostic, designed to provide in situ surface characterization of plasma facing components in a tokamak environment. MAPP has been implemented for operation on the Lithium Tokamak Experiment at Princeton Plasma Physics Laboratory (PPPL), where all control and analysis systems are currently under development for full remote operation. Control systems include vacuum management, instrument power, and translational/rotational probe drive. Analysis systems include onboard Langmuir probes and all components required for x-ray photoelectron spectroscopy, low-energy ion scattering spectroscopy, direct recoil spectroscopy, and thermal desorption spectroscopy surface analysis techniques.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Langmuir probe measurements and mass spectrometry of plasma plumes generated by laser ablation of La{sub 0.4}Ca{sub 0.6}MnO{sub 3}

The plasma formed in vacuum by UV nanosecond laser ablation of La{sub 0.4}Ca{sub 0.6}MnO{sub 3} in the fluence range of 0.8 to 1.9 J cm{sup −2} using both Langmuir probe analysis and energy-resolved mass spectrometry has been studied. Mass spectrometry shows that the main positive ion species are Ca{sup +}, Mn{sup +}, La{sup +}, and LaO{sup +}. The Ca{sup +} and Mn{sup +} energy distributions are quite broad and lie in the 0–100 eV region, with the average energies increasing with laser fluence. In contrast, the La{sup +} and LaO{sup +} distributions are strongly peaked around 10 eV. The net time-of-arrival signal derived from the measured positive ion energy distributions is broadly consistent with the positive ion signal measured by the Langmuir probe. We also detected a significant number of O{sup −} ions with energies in the range of 0 to 10 eV. The Langmuir probe was also used to measure the temporal variation of the electron density and temperature at 6 cm from the ablation target. In the period when O{sup −} ions are found at this position, the plasma conditions are consistent with those required for significant negative oxygen ion formation, as revealed by studies on radio frequency excited oxygen plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A hemispherical Langmuir probe array detector for angular resolved measurements on droplet-based laser-produced plasmas

In this work, a new diagnostic tool for laser-produced plasmas (LPPs) is presented. The detector is based on a multiple array of six motorized Langmuir probes. It allows to measure the dynamics of a LPP in terms of charged particles detection with particular attention to droplet-based LPP sources for EUV lithography. The system design permits to temporally resolve the angular and radial plasma charge distribution and to obtain a hemispherical mapping of the ions and electrons around the droplet plasma. The understanding of these dynamics is fundamental to improve the debris mitigation techniques for droplet-based LPP sources. The device has been developed, built, and employed at the Laboratory for Energy Conversion, ETH Zürich. The experimental results have been obtained on the droplet-based LPP source ALPS II. For the first time, 2D mappings of the ion kinetic energy distribution around the droplet plasma have been obtained with an array of multiple Langmuir probes. These measurements show an anisotropic expansion of the ions in terms of kinetic energy and amount of ion charge around the droplet target. First estimations of the plasma density and electron temperature were also obtained from the analysis of the probe current signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact and high-particle-flux thermal-lithium-beam probe system for measurement of two-dimensional electron density profile

A compact and high-particle-flux thermal-lithium-beam source for two-dimensional measurement of electron density profiles has been developed. The thermal-lithium-beam oven is heated by a carbon heater. In this system, the maximum particle flux of the thermal lithium beam was ∼4 × 10{sup 19} m{sup −2} s{sup −1} when the temperature of the thermal-lithium-beam oven was 900 K. The electron density profile was evaluated in the small tokamak device HYBTOK-II. The electron density profile was reconstructed using the thermal-lithium-beam probe data and this profile was consistent with the electron density profile measured with a Langmuir electrostatic probe. We confirm that the developed thermal-lithium-beam probe can be used to measure the two-dimensional electron density profile with high time and spatial resolutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of micro-contact resistance between a gold nanocrystalline line and a tungsten electrode probe in interconnect fatigue testing

An electromechanically-coupled micro-contact resistance measurement system is built to mimic the contact process during fatigue testing of nanoscale-thickness interconnects using multiple probe methods. The design combines an optical microscope, high-resolution electronic balance, and micromanipulator-controlled electric probe, and is coupled with electrical measurements to investigate microscale contact physics. Experimental measurements are performed to characterize the contact resistance response of the gold nanocrystalline pad of a 35-nm-thick interconnect under mechanical force applied by a tungsten electrode probe. Location of a stable region for the contact resistance and the critical contact force provides better understanding of micro-contact behavior relative to the effects of the contact force and the nature of the contact surface. Increasing contact temperature leads to reduced contact resistance, softens the pad material, and modifies the contact surface. The stability of both contact resistance and interconnect resistance is studied under increasing contact force. Major fluctuations emerge when the contact force is less than the critical contact force, which shows that temporal contact resistance will affect interconnect resistance measurement accuracy, even when using the four-wire method. This performance is demonstrated experimentally by heating the Au line locally with a laser beam. Finally, the contact resistances are calculated using the LET (Li–Etsion–Talke) model together with combined Holm and Sharvin theory under various contact forces. Good agreement between the results is obtained. This research provides a way to measure change in interconnect line resistance directly under a stable contact resistance regime with a two-wire method that will greatly reduce the experimental costs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved optogalvanic detection with voltage biased Langmuir probes

Optogalvanic detectors show great potential for infrared spectroscopy, especially in cavity enhanced techniques where they, in contrast to ordinary absorption detectors, can perform intracavity measurements. This enables them to utilize the signal-to-noise ratio improvement gained from the extended effective path length inside an optical cavity, without losing signal strength due to the limited amount of light exiting through the rear mirror. However, if optogalvanic detectors are to become truly competitive, their intrinsic sensitivity and stability has to be improved. This, in turn, requires a better understanding of the mechanisms behind the generation of the optogalvanic signal. The study presented here focuses on an optogalvanic detector based on a miniaturized stripline split-ring resonator plasma source equipped with Langmuir probes for detecting the optogalvanic signal. In particular, the effect of applying a constant bias voltage to one of the probes is investigated, both with respect to the sensitivity and stability, and to the mechanism behind the generation of the signal. Experiments with different bias voltages at different pressures and gas composition have been conducted. In particular, two different gas compositions (pure CO{sub 2} and 0.25% CO{sub 2} in 99.75% N{sub 2}) at six different pressures (100 Pa to 600 Pa) have been studied. It has been shown that probe biasing effectively improves the performance of the detector, by increasing the amplitude of the signal linearly over one order of magnitude, and the stability by about 40% compared with previous studies. Furthermore, it has been shown that relatively straightforward plasma theory can be applied to interpret the mechanism behind the generation of the signal, although additional mechanisms, such as rovibrational excitation from electron-molecule collisions, become apparent in CO{sub 2} plasmas with electron energies in the 1–6 eV range. With the achieved performance improvement and the more solid theoretical framework presented here, stripline split-ring resonator optogalvanic detectors can evolve into a compact, inexpensive, and easy-to-operate alternative for future infrared spectrometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct probing of electron and hole trapping into nano-floating-gate in organic field-effect transistor nonvolatile memories

Electron and hole trapping into the nano-floating-gate of a pentacene-based organic field-effect transistor nonvolatile memory is directly probed by Kelvin probe force microscopy. The probing is straightforward and non-destructive. The measured surface potential change can quantitatively profile the charge trapping, and the surface characterization results are in good accord with the corresponding device behavior. Both electrons and holes can be trapped into the nano-floating-gate, with a preference of electron trapping than hole trapping. The trapped charge quantity has an approximately linear relation with the programming/erasing gate bias, indicating that the charge trapping in the device is a field-controlled process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Localized excitation of magnetostatic surface spin waves in yttrium iron garnet by shorted coaxial probe detected via spin pumping and rectification effect

We demonstrate the localized excitation and dc electrical detection of magnetostatic surface spin waves (MSSWs) in yttrium iron garnet (YIG) by a shorted coaxial probe. Thin films of NiFe and Pt are patterned at different regions onto a common bulk YIG substrate. A shorted coaxial probe is used to excite spin precession locally near various patterned regions. The dc voltages across the corresponding regions are recorded. For excitation of the Pt regions, the dc voltage spectra are dominated by the spin pumping of MSSWs from YIG, where various modes can be clearly distinguished. For the NiFe region, it is also found that spin pumping from MSSWs generated in YIG dominated the spectra, indicating that the spin pumped currents are dissipated into charge currents via the inverse Spin Hall effect (ISHE) in NiFe. For all regions, dc signals from YIG MSSWs are observed to be much stronger than the ferromagnetic resonance (FMR) uniform mode, likely due to the nature of the microwave excitation. The results indicate the potential of this probe for microwave imaging via dc detection of spin dynamics in continuous and patterned films.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

How plasma parameters fluctuations influence emissive probe measurements

Relationship between the floating potential of an emissive probe and plasma potential oscillations is studied in the case of controlled oscillations of plasma parameters. This relationship is compared to a quasi-static model for floating potential oscillations that assumes a constant emission current and includes the fluctuations of plasma parameters (density and electron temperature). Two different plasma regimes are considered. In the first one, the model is coherent with experimental results. In the second, the model does not fulfill one of the assumption due to the evidence of emission current oscillations when the mean emission current exceeds a given threshold. This second regime highlights the importance of taking into account emission current oscillations in the interpretation of emissive probe measurements. Nevertheless, discrepancies are still observed between emissive probe floating potential and plasma potential oscillations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multidirectional plasma flow measurement by Gundestrup Probe in scrape-off layer of ADITYA tokamak

Multidirectional plasma flow measurements by using Gundestrup Probe in the scrape-off layer of ADITYA tokamak are presented. The ADITYA Gundestrup Probe-head consists of eight plates arranged around the ceramic rod and three pins normal to side plates. Plates are used to measure both parallel and perpendicular flows simultaneously and pins are used to measure plasma density and floating potential. A comparison of direct perpendicular flow measurement and by two other plates of Gundestrup Probe is presented. Possible causes of perpendicular flows are identified and compared with the measured flows. It is observed that the mechanism of the parallel flow and the perpendicular flow is different only at high parallel Mach number. A puff of the working gas is used to study its effect on the perpendicular flows and its reversal with the gas puff is observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative analysis of doped/undoped ZnO nanomaterials using laser assisted atom probe tomography: Influence of the analysis parameters

In the last decade, atom probe tomography has become a powerful tool to investigate semiconductor and insulator nanomaterials in microelectronics, spintronics, and optoelectronics. In this paper, we report an investigation of zinc oxide nanostructures using atom probe tomography. We observed that the chemical composition of zinc oxide is strongly dependent on the analysis parameters used for atom probe experiments. It was observed that at high laser pulse energies, the electric field at the specimen surface is strongly dependent on the crystallographic directions. This dependence leads to an inhomogeneous field evaporation of the surface atoms, resulting in unreliable measurements. We show that the laser pulse energy has to be well tuned to obtain reliable quantitative chemical composition measurements of undoped and doped ZnO nanomaterials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗