The Joint Airport Weather Studies Project - Current analysis highlights in the aviation safety context

The principal objective of the Joint Airport Weather Studies Project was to obtain high-resolution velocity, turbulence, and thermodynamic data on a convective outflow called a microburst, an intense downdraft and resulting horizontal outflow near the surface. Data collection occurred during the summer of 1982 near Denver, CO. Data sensors included three pulsed-microwave Doppler and two pulsed CO2 lidar radars, along with 27 Portable Automated Mesonet surface weather stations, the FAA's low-level-wind-shear alert system (LLWSAS), and five instrumented research aircraft. Convective storms occurred on 75 of 91 operational days, with Doppler data being collected on at least 70 microbursts. Analyses reported included a thorough examination of microburst-climatology statistics, the capability of the LLWSAS to detect adequately and accurately the presence of low-altitude wind shear danger to aircraft, the capability of a terminal Doppler radar system development to provide improved wind-shear detection and warning, and progress toward improved wind-shear training for pilots.

Mccarthy, J.↗

Development and flight test of an X-band precision approach concept for remote-area rotorcraft operations

A novel airborne radar-based precision approach concept was developed and flight tested as a part of NASA's Rotorcraft All-Weather Operations Research Program. A demonstration, transponder-based beacon landing system (BLS), incorporating state-of-the-art X-band radar technology and digital processing techniques, was built and flight tested to demonstrate the concept feasibility. The BLS airborne hardware consists of an add-on microprocessor, installed in conjunction with the aircraft weather/mapping radar, which analyzes the radar beacon receiver returns and determines range, localizer deviation, and glide slope deviation. The ground station is an inexpensive, portable unit which can be quickly deployed at a landing site. Results from the flight test program show that the BLS concept has a significant potential for providing rotorcraft with low-cost, precision, instrument approach capability in remote areas. Previously announced in STAR as N84-10041

Clary, G. R.↗

"Speaking" Microcomputer

Microcomputer system allows blind person to use portable computer and communicate with remote mainframe computer. System prepares data for transmission to mainframe, translates data transmitted from mainframe for its own use, and converts data ordinarily displayed on its video screen into synthesized speech.

Mandy, C.↗

Camera for Monitoring Vegetation

Video camera uses solid-state imaging devices and light filters to bring out subtle spectral differences between healthy and stressed vegetation differences not readily detectable with infrared film cameras. Camera employs two detector arrays. Video camera made small and easily portable. Eliminates need for refrigeration of film before use, and provides instantaneous output with no delay for film development.

Martin, T. Z.↗

Toggle Hinge for Deployable Struts

Toggle hinge allows deployable structures erected without end play encountered in conventional hinged structural members. New hinge ensures rigidity in portable bridges, masts, towers, platforms, and other deployable (and retractable) structures. Positioned halfway along length of folding strut, hinge allows halves of strut to pivot 180 degrees about center.

Barbour, R. T.↗

Bistable Articulated Joint

Joint with four-bar-linkage geometry has following attributes: Springs to fully extended fully folded positions. Automatically locks in its extended position. Joint combines zero backlash, positive locking, and centerline pivoting. Used in folding tool handles, portable antenna booms, and many other deployable structures.

Graighead, Norwood D., II↗

Rotating Capacitor Measures Steady Electric Fields

Portable sensor measures electric fields created by dc powerlines or other dc-high-voltage sources. Measures fields from 70 to 50,000 V/m with linearity of 2 percent. Sensor used at any height above ground. Measures both magnitude and direction of field and provides signals representing these measurements to remote readout device. Sensor functions with minimal disturbance of field it is measuring.

Johnston, A. R.↗

Detecting Trace Contaminants in the Atmosphere

Sensitive instrument uses two low-energy electron beams to detect certain molecules. Experimental instrument identifies and measures trace contaminants in atmosphere. When fully developed, portable instrument expected to measure contaminant concentrations of certain halogen containing molecules as low as one part per trillion. Instrument employs electron beams to ionize contaminant molecules by dissociative attachment of electrons.

Srivastava, S. K.↗

Applications of aerospace technology in biology and medicine

Utilization of National Aeronautics and Space Administration (NASA) technology in medicine is discussed. The objective is best obtained by stimulation of the introduction of new or improved commercially available medical products incorporating aerospace technology. A bipolar donor/recipient model of medical technology transfer is presented to provide a basis for the team's methodology. That methodology is designed to: (1) identify medical problems and NASA technology that, in combination, constitute opportunities for successful medical products; (2) obtain the early participation of industry in the transfer process; and (3) obtain acceptance by the medical community of new medical products based on NASA technology. Two commercial transfers were completed: the Stowaway, a lightweight wheelchair that provides mobility for the disabled and elderly in the cabin of commercial aircraft, and Micromed, a portable medication infusion pump for the reliable, continuous infusion of medications such as heparin or insulin. The marketing and manufacturing factors critical to the commercialization of the lightweight walker incorporating composite materials were studied. Progress was made in the development and commercialization of each of the 18 currently active projects.

Bass, B.↗

International test and demonstration of a 1-MW wellhead generator: Helical screw expander power plant

A 1-MW wellhead generator was tested in 1980, 1981, and 1982 by Mexico, Italy, and New Zealand at Cerro Prieto, Cesano, and Broadlands, respectively. The total flow helical screw expander portable power plant, Model 76-1, had been built for the U.S. Government and field-tested in Utah, USA, in 1978 and 1979. The expander had oversized internal clearances designed for self-cleaning operation on fluids that deposit adherent scale normally detrimental to the utiliation of liquid dominated fields. Conditions with which the expander was tested included inlet pressures of 64 to 220 psia, inlet qualities of 0% to 100%, exhaust pressures of 3.1 to 40 psia, electrial loads of idle and 110 to 933 kW, electrical frequencies of 50 and 60 Hz, male rotor speeds of 2500 to 4000 rpm, and fluid characteristics to 310,000 ppm total dissolved solids and noncondensables to 38 wt % of the vapor. Some testing was done on-grid. Typical expander isentropic efficiency was 40% to 50% with the clearances not closed, and 5 percentage points or more higher with the clearances partly closed. The expander efficiency increased approximately logarithmically with shaft power for most operations, while inlet quality, speed, and pressure ratio across the machine had only small effects. These findings are all in agreement with the Utah test results.

Mckay, R. A.↗

The 1984 NASA/ASEE summer faculty fellowship program

The assessment of forest productivity and associated nitrogen flux in a number of conifer ecosystems is described. As a base line study of acid precipitation in the Sierra Nevada, involved is the extraction and integration of a number of data planes describing the terrain, soils, lithology, vegetation cover and structure, and microclimate of the region. The development of automated techniques to extract topographic networks (stream canyons and ridge lines) for use as a landscrape skeleton to organize and integrate data sets into an efficient geographical information system is examined. The software is written in both FORTRAN and C, and is portable to a number of different computer environments with minimal modification.

Source record↗

Challenges of developing an electro-optical system for measuring man's operational envelope

In designing work stations and restraint systems, and in planning tasks to be performed in space, a knowledge of the capabilities of the operator is essential. Answers to such questions as whether a specific control or work surface can be reached from a given restraint and how much force can be applied are of particular interest. A computer-aided design system has been developed for designing and evaluating work stations, etc., and the Anthropometric Measurement Laboratory (AML) has been charged with obtaining the data to be used in design and modeling. Traditional methods of measuring reach and force are very labor intensive and require bulky equipment. The AML has developed a series of electro-optical devices for collecting reach data easily, in computer readable form, with portable systems. The systems developed, their use, and data collected with them are described.

Woolford, B.↗

Techniques for measuring intercepted and absorbed PAR in corn canopies

The quantity of radiation potentially available for photosynthesis that is captured by the crop is best described as absorbed photosynthetically active radiation (PAR). Absorbed PAR (APAR) is the difference between descending and ascending fluxes. The four components of APAR were measured above and within two planting densities of corn (Zea mays L.) and several methods of measuring and estimating APAR were examined. A line quantum sensor that spatially averages the photosynthetic photon flux density provided a rapid and portable method of measuring APAR. PAR reflectance from the soil (Typic Argiaquoll) surface decreased from 10% to less than 1% of the incoming PAR as the canopy cover increased. PAR reflectance from the canopy decreased to less than 3% at maximum vegetative cover. Intercepted PAR (1 - transmitted PAR) generally overestimated absorbed PAR by less than 4% throughout most of the growing season. Thus intercepted PAR appears to be a reasonable estimate of absorbed PAR.

Gallo, K. P.↗

PISCES: An environment for parallel scientific computation

The parallel implementation of scientific computing environment (PISCES) is a project to provide high-level programming environments for parallel MIMD computers. Pisces 1, the first of these environments, is a FORTRAN 77 based environment which runs under the UNIX operating system. The Pisces 1 user programs in Pisces FORTRAN, an extension of FORTRAN 77 for parallel processing. The major emphasis in the Pisces 1 design is in providing a carefully specified virtual machine that defines the run-time environment within which Pisces FORTRAN programs are executed. Each implementation then provides the same virtual machine, regardless of differences in the underlying architecture. The design is intended to be portable to a variety of architectures. Currently Pisces 1 is implemented on a network of Apollo workstations and on a DEC VAX uniprocessor via simulation of the task level parallelism. An implementation for the Flexible Computing Corp. FLEX/32 is under construction. An introduction to the Pisces 1 virtual computer and the FORTRAN 77 extensions is presented. An example of an algorithm for the iterative solution of a system of equations is given. The most notable features of the design are the provision for several granularities of parallelism in programs and the provision of a window mechanism for distributed access to large arrays of data.

Pratt, T. W.↗

The Multimission Image Processing Laboratory's virtual frame buffer interface

Large image processing systems use multiple frame buffers with differing architectures and vendor supplied interfaces. This variety of architectures and interfaces creates software development, maintenance and portability problems for application programs. Several machine-dependent graphics standards such as ANSI Core and GKS are available, but none of them are adequate for image processing. Therefore, the Multimission Image Processing laboratory project has implemented a programmer level virtual frame buffer interface. This interface makes all frame buffers appear as a generic frame buffer with a specified set of characteristics. This document defines the virtual frame uffer interface and provides information such as FORTRAN subroutine definitions, frame buffer characteristics, sample programs, etc. It is intended to be used by application programmers and system programmers who are adding new frame buffers to a system.

Wolfe, T.↗

Data-link alternatives for the NASA pilot data systems

There are several preliminary, or pilot, efforts for developing data systems for supporting NASA science research. The Pilot Data Systems consist of the Pilot Land Data System (PLDS), the Pilot Ocean Data System (PODS), the Pilot Climate Data System (PCDS), and the Pilot Planetary Data System (PPDS). The PLDS is likely to have the greatest communication needs of the various pilots. Communications issues and requirements are examined in the context of the mature PLDS as it may exist by 1990. The PLDS is seen as a distributed processing system linking resources at a number of NASA research centers and outside universities. Large image data sets, including LANDSAT scenes, are a major data type to be moved along the PLDS communications network. The unusually large size of these data files requires examining new technologies that may allow efficient and affordable communication at rates of up to 60 megabits per second. Potentially useful developments include portable satellite ground stations, and time division multiple access for sharing high-speed satellite links. Further pooling of communications for the various data systems into a single network would reduce costs and may make economic justification of access to the required data rates possible.

Likens, W. C.↗

Test and evaluation of the 2.4-micron photorefractor ocular screening system

An improved 2.4-m photorefractor ocular screening system was tested and evaluated. The photorefractor system works on the principal of obtaining a colored photograph of both human eyes; and, by analysis of the retinal reflex images, certain ocular defects can be detected such a refractive error, strabismus, and lens obstructions. The 2.4-m photorefractory system uses a 35-mm camera with a telephoto lens and an electronic flash attachment. Retinal reflex images obtained from the new 2.4-m system are significantly improved over earlier systems in image quality. Other features were also improved, notably portability and reduction in mass. A total of 706 school age children were photorefracted, 211 learning disabled and 495 middle school students. The total students having abnormal retinal reflexes were 156 or 22 percent, and 133 or 85 percent of the abnormal had refractive error indicated. Ophthalmological examination was performed on 60 of these students and refractive error was verified in 57 or 95 percent of those examined. The new 2.4-m system has a NASA patent pending and is authorized by the FDA. It provides a reliable means of rapidly screening the eyes of children and young adults for vision problems. It is especially useful for infants and other non-communicative children who cannot be screened by the more conventional methods such as the familiar E chart.

Richardson, J. R.↗

Precise time transfer using MKIII VLBI technology

It is well known that Very Long Baseline Interferometry (VLBI) is capable of precise time synchronization at subnanosecond levels. This paper deals with a demonstration of clock synchronization using the MKIII VBLI system. The results are compared with clock synchronization by traveling cesium clocks and GPS. The comparison agrees within the errors of the portable clocks (+ 5 ns) and GPS(+ or - 30 ns) systems. The MKIII technology appears to be capable of clock synchronization at subnanosecond levels and appears to be very good benchmark system against which future time synchronization systems can be evaluated.

Johnston, K. J.↗