Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plane of array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Low Average Sidelobe Slot Array Antennas for Radiometer Applications

In radiometer applications, it is required to design antennas that meet low average sidelobe levels and low average return loss over a specified frequency bandwidth. It is a challenge to meet such specifications over a frequency range when one uses resonant elements such as waveguide feed slots. In addition to their inherent narrow frequency band performance, the problem is exacerbated due to modeling errors and manufacturing tolerances. There was a need to develop a design methodology to solve the problem. An iterative design procedure was developed by starting with an array architecture, lattice spacing, aperture distribution, waveguide dimensions, etc. The array was designed using Elliott s technique with appropriate values of the total slot conductance in each radiating waveguide, and the total resistance in each feed waveguide. Subsequently, the array performance was analyzed by the full wave method of moments solution to the pertinent integral equations. Monte Carlo simulations were also carried out to account for amplitude and phase errors introduced for the aperture distribution due to modeling errors as well as manufacturing tolerances. If the design margins for the average sidelobe level and the average return loss were not adequate, array architecture, lattice spacing, aperture distribution, and waveguide dimensions were varied in subsequent iterations. Once the design margins were found to be adequate, the iteration was stopped and a good design was achieved. A symmetric array architecture was found to meet the design specification with adequate margin. The specifications were near 40 dB for angular regions beyond 30 degrees from broadside. Separable Taylor distribution with nbar=4 and 35 dB sidelobe specification was chosen for each principal plane. A non-separable distribution obtained by the genetic algorithm was found to have similar characteristics. The element spacing was obtained to provide the required beamwidth and close to a null in the E-plane end-fire direction. Because of the alternating slot offsets, grating lobes called butterfly lobes are produced in non-principal planes close to the H-plane. An attempt to reduce the influence of such grating lobes resulted in a symmetric design.

Rengarajan, Sembiam↗

The optomechanical design for the Off-plane Grating Rocket Experiment (OGRE)

The Off-plane Grating Rocket Experiment (OGRE) is a sounding rocket payload designed to obtain a high-resolution soft X-ray spectrum of Capella. OGRE’s optical system uses new technologies including state-of-the-art X-ray optics, custom arrays of reflection gratings, and an array of EM-CCDs. Many of these technologies will be tested for the first time in flight with OGRE. To achieve the high performance that these new technologies are capable of, the payload components must be properly aligned to meet high tolerances. This paper will outline OGRE’s opto-mechanical design for achieving alignment within these tolerances. Specifically, the design of the X-ray grating arrays will be discussed.

Bridget C. O’Meara↗

X-Ray Detector Research at MSFC for Space Applications

NASA's Vision for Space Exploration has specific goals aimed at exploring the Solar System. This vision, under presidential mandate includes landing humans on the moon before the end of the next decade, paving the way for eventual journeys to Mars and beyond. The first missions to the moon will be in the form of both Orbiters and Landers, with the goal of paving the way for human return. One of the instruments we are currently working on,in collaboration with Brookhaven National Laboratory, is a lunar orbiter fluorescent x-ray spectrometer to finely map the light elements (down to Carbon) on surface of the moon. Funded NASA s Planetary Instrument Definition and Development Program the instrument is based on silicon drift detector arrays read out by custom ASICs. These offer the promise of high spectral resolution, necessary for resolving weak lines against a strong background continuum, and very low power requirements, necessary for large areas (greater than 500 square centimeters) required for future lunar missions. Further, the inherent radiation hardness of these detectors makes them ideal candidates for exploring the Jovian system, where the harsh radiation environment from Jupiter s radiation belts creates unfavorable detector conditions. Looking beyond our solar system, in the hard x-ray regime (20-80keV.), we are studying Cadmium-Zinc-Telluride pixilated detectors as feasible candidates for focal plane detectors of a hard x-ray telescope. This energy region bridges the gap between thermal and non-thermal x-ray emission from astronomical sources, will allow us to better understand supernovae nucleosynthesis (such as through the Ti-44 lines at 68keV and 78keV), Active Galactic Nuclei and other compact objects, more completely. The detectors that we are characterizing are 2mm in thickness and are pixilated with a 16x16 array of 300 micrometer pitch pixels (50micometer gap). These detectors are designed at Rutherford Appleton Laboratory, material is from eV Products, and polymer flip-chip assembly was performed by a commercial vendor. An energy resolution of 2.0% at 60keV (or better) should allow us to sufficiently distinguish lines of interest from background continuum, and the detector spatial resolution should be fine enough to over-sample the focal spot from the x-ray focusing optics by about a factor of two. Full technical details of these developments will be presented.

Gaskin, Jessica↗

Development of arrays of position-sensitive microcalorimeters for Constellation-X

We are developing arrays of position-sensitive transition-edge sensor (POST) X-ray detectors for future astronomy missions such as NASA's Constellation-X. The POST consists of multiple absorbers thermally coupled to one or more transition-edge sensor (TES). Each absorber element has a different thermal coupling to the TES. This results in a distribution of different pulse shapes and enables position discrimination between the absorber elements. POST'S are motivated by the desire to achieve the largest possible focal plane area with the fewest number of readout channels and are ideally suited to increasing the Constellation-X focal plane area, without comprising on spatial sampling. Optimizing the performance of POST'S requires careful design of key parameters such as the thermal conductances between the absorbers, TES and the heat sink. as well as the absorber heat capacities. Using recently developed signal processing algorithms we have investigated the trade-off between position-sensitivity, energy resolution and pulse decay time. based on different device design parameters for PoST's. Our new generation of PoST's utilize technology successfully developed on high resolution (approximately 2.5eV) single pixels arrays of Mo/Au TESs. also under development for Constellation-X. This includes noise mitigation features on the TES and low resistivity electroplated absorbers. We report on the first experimental results from these new one and two-channel PoST"s, consisting of all Au and composite Au/Bi absorbers, which are designed to achieve an energy resolution of < 10 eV. coupled with count-rates of 100's per pixel per second and position sensitivity over the energy range 0.3-10 keV.

Smith, S. J.↗

Optical polarimetry and thermal imaging of the disc around Beta Pictoris

The dust disk around the main-sequence A5 star Beta Pic is characterized on the basis of recently obtained data. Optical polarimetry indicates that the disk has polarization of about 15 percent and polarization vectors normal to the scattering plane, indicating that the features observed are indeed a dust disk made visible by scattering. Thermal images of the central 13-arcsec-diameter region, obtained at 10 and 20 microns by Telesco et al. (1988) using the NASA Marshall 20-pixel bolometer array, suggest that the dust grains in the disk have a mean diameter of 1 micron or smaller. Also discussed are (1) unsuccessful searches for other nearby stars with disks and (2) the potential value of Hubble Space Telescope images for understanding the structure of Beta Pic.

Wolstencroft, R. D.↗

Antenna System of the NASA Wind Spacecraft Measured with the Russian Radar Facility "Sura"

Recent (November 1996) joint experiments between the Russian radar facility "Sura" and the NASA Wind spacecraft have permitted us to measure the antenna patterns of two orthogonal dipoles mounted on the spacecraft and to determine the polarization state of the radar array. Both findings were produced by direct measurements. The Wind antenna operating frequency range is 1.075 to 13.825 MHz. The spacecraft is spinning around its Z axis and a dipole "Z" is oriented along this axis and another dipole "Z" is in the plane normal to Z which coincides with the ecliptic plane. Three modes of Wind antenna operation were used: the Y signal added with the Z signal, the Y signal phased shifted by 90 deg added with the Z signal, as well as the Z signal itself. These three Wind antenna modes permit measurement of the Stokes parameters of the radiation.

Belov, Yu.↗

Imaging interferometry with non-redundant arrays

The performance of a set of nonredundant arrays, that convert an existing telescope to an interferometer, was simulated. Each array is a perforated mask, placed at an image of the objective. Each pair of holes in a mask transmits a unique spatial frequency that is present in the target; hence the term nonredundant. Each mask produces a fringe I(f) in the focal plane that is the product of the Fourier transforms of the object and the optical transfer function S(f).

Zirker, J. B.↗

Analysis of Measured and Predicted Acoustics From an XV-15 Flight Test

Flight acoustic and vehicle state data from an XV-15 acoustic flight test are examined. Flight predictions using TiltRotor Aeroacoustic Code (TRAC) are performed for a level flight (repeated) and four descent conditions (including a blade vortex interaction (BVI)). The assumptions and procedures used for TRAC flight predictions as well as the variability in flight measurements, which are used for input and comparison to predictions, are investigated in detail. Differences were found in the measured vehicle airspeed, altitude, glideslope, and vehicle orientation (yaw, pitch, and roll angle) between each of the repeat runs. These differences violate some of the prediction assumptions and significantly impacted the resulting acoustic predictions. Multiple acoustic pulses, with a variable time between the pulses, were found in the measured acoustic time histories for the repeat runs. These differences could be attributed in part to the variability in vehicle orientation. Acoustic predictions that used the measured vehicle orientation for the repeat runs captured this multiple pulse variability. Thickness noise was found to be dominant on approach for all the cases, except the BVI condition. After the aircraft passed overhead, broadband noise and low frequency loading noise were dominant. The predicted LowSPL time histories compared well with measurement on approach to the array for the non-BVI conditions and poorly for the BVI condition. Accurate prediction of the lift share between the rotor and fuselage must be known in order to improve predictions. At a minimum, measurements of the rotor thrust and tip-path-plane angle are critical to further develop accurate flight acoustic prediction capabilities.

Boyd, D. Douglas, Jr.↗

Analysis of Measured and Predicted Acoustics from an XV-15 Flight Test

Flight acoustic and vehicle state data from an XV-15 acoustic flight test are examined. Flight predictions using TRAC are performed for a level flight (repeated) and four descent conditions (including a BVI). The assumptions and procedures used for TRAC flight predictions as well as the variability in flight measurements, which are used for input and comparison to predictions, are investigated in detail. Differences were found in the measured vehicle airspeed, altitude, glideslope, and vehicle orientation (yaw, pitch and roll angle) between each of the repeat runs. These differences violate some of the prediction assumptions and significantly impacted the resulting acoustic predictions. Multiple acoustic pulses, with a variable time between the pulses, were found in the measured acoustic time histories for the repeat runs. These differences could be attributed in part to the variability in vehicle orientation. Acoustic predictions that used the measured vehicle orientation for the repeat runs captured this multiple pulse variability. Thickness noise was found to be dominant on approach for all the cases, except the BVI condition. After the aircraft passed overhead, broadband noise and low frequency loading noise were dominant. The predicted LowSPL time histories compared well with measurement on approach to the array for the non-BVI conditions and poorly for the BVI condition. Accurate prediction of the lift share between the rotor and fuselage must be known in order to improve predictions. At a minimum, measurements of the rotor thrust and tip-path-plane angle are critical to further develop accurate flight acoustic prediction capabilities.

Boyd, D. Douglas, Jr.↗

Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or pixilated array of x-ray absorbers shares fewer numbers of temperature sensors. A means of discriminating the signals from different absorber positions, however, needs to be built into the device for each sensor. The design concept for the device is such that the shape of the temperature pulse with time depends on the location of the absorber. This inherent position sensitivity of the signal is then analyzed to determine the location of the event precisely, effectively yielding one device with many sub-pixels. With such devices, the total number of electronic channels required to read out a given number of pixels is significantly reduced. PoSMs were developed that consist of four discrete absorbers connected to a single magnetic sensor. The design concept can be extended to more than four absorbers per sensor. The thermal conductance between the sensor and each absorber is different by design and consequently, the pulse shapes are different depending upon which absorber the xrays are received, allowing position discrimination. A magnetic sensor was used in which a paramagnetic Au:Er temperature-sensitive material is located in a weak magnetic field. Deposition of energy from an x-ray photon causes an increase in temperature, which leads to a change of magnetization of the paramagnetic sensor, which is subsequently read out using a low noise dc-SQUID. The PoSM microcalorimeters are fully microfabricated: the Au:Er sensor is located above the meander, with a thin insulation gap in between. For this position-sensitive device, four electroplated absorbers are thermally linked to the sensor via heat links of different thermal conductance. One pixel is identical to that of a single-pixel design, consisting of an overhanging absorber fabricated directly on top of the sensor. It is therefore very strongly thermally coupled to it. The three other absorbers are supported directly on a silicon-nitride membrane. These absorbers are thermally coupled to the sensor via Ti (5 nm)/Au250 nm) metal links. The strength of the links is parameterized by the number of gold squares making up the link. For detector performance, experimentally different pulse-shapes were demonstrated with 6 keV x-rays, which clearly show different rise times for different absorber positions. For energy resolution measurement, the PoSM was operated at 32 mK with an applied field that was generated using a persistent current of 50 mA. Over the four pixels, energy resolution ranges from 4.4 to 4.7 eV were demonstrated.

Bandler, SImon↗

Summary of LSST systems analysis and integration task for SPS flight test articles

The structural and equipment requirements for two solar power satellite (SPS) test articles are defined. The first SPS concept uses a hexagonal frame structure to stabilize the array of primary tension cables configured to support a Mills Cross antenna containing 17,925 subarrays composed of dipole radiating elements and solid state power amplifier modules. The second test article consists of a microwave antenna and its power source, a 20 by 200 m array of solar cell blankets, both of which are supported by the solar blanket array support structure. The test article structure, a ladder, is comprised of two longitudinal beams (215 m long) spaced 10 m apart and interconnected by six lateral beams. The system control module structure and bridge fitting provide bending and torsional stiffness, and supplement the in plane Vierendeel structure behavior. Mission descriptions, construction, and structure interfaces are addressed.

Greenberg, H. S.↗

Dispersive spectroscopy on AXAF

The designs of two transmission grating spectrometers and a Bragg crystal spectrometer that are being developed for the Advanced X-ray Astrophysics Facility (AXAF) are described. The gratings, which are composed of arrays of small facets mounted on plates which can be inserted immediately behind the AXAF telescope, divide the AXAF energy band (80 eV-10 keV) into three regions and attain very high resolving powers for point sources. The Bragg Crystal Spectrometer (BCS) is a focal plane instrument, in which X-rays that satisfy the Bragg law are reflected from a curved crystal which refocuses the beam onto an imaging detector. The BCS achieves the highest spectral resolutions of the AXAF spectrometers: for E values between 500 and 1600 eV, the FWHM of a narrow line is less than 1 eV.

Markert, T. H.↗

Infrared focal plane design for the Comet Rendezvous/Asteroid Flyby and Cassini Visible and Infrared Mapping Spectrometers

A focal plane assembly combining hybrid electronic components with passive optical components within a single hermetically sealed package has been designed by Cincinnati Electronics to meet the performance requirements imposed by the Comet Rendezvous/Asteroid Flyby (CRAF) and Cassini Visible and Infrared Mapping Spectrometers (VIMSs). A single line array of 256 InSb photodiodes, accessed by two 1 x 128 multiplexers, provides continuous spectral coverage from 0.85 to 5.1 microns. Intrinsic field-of-view apertures and a unique order sorting filter require critical optical alignment within the hybrid. FPA performance requirements, design approach, and critical issues are discussed.

Staller, Craig↗

SHARC II: A Caltech Submillimeter Observatory Facility Camera with 384 Pixels

SHARC II is a background-limited 350 micron and 450 micron facility camera for the Caltech Submillimeter Observatory undergoing commissioning in 2002. The key component of SHARC II is a 12 x 32 array of doped silicon 'pop-up' bolometers developed at NASA/Goddard. Each 1 mm x 1 mm pixel is coated with a 400 Omega/square bismuth film and located lambda/4 above a reflective backshort to achieve greater than 75% absorption efficiency. The pixels cover the focal plane with greater than 90% filling factor. At 350 microns, the SHARC II pixels are separated by 0.65 lambda/D. In contrast to the silicon bolometers in the predecessor of SHARC II, each doped thermistor occupies nearly the full area of the pixel, which lowers the 1/f knee of tile detector noise to less than 0.03 Hz, under load, at tile bath temperature of 0.36 K. The bolometers are AC-biased and read in 'total power' mode to take advantage of the improved stability. Each bolometer is biased through a custom approx. 130 MOmega CrSi load resistor at 7 K and read with a commercial JFET at 120 K. The JFETs and load resistors are integrated with the detectors into a single assembly to minimize microphonic noise. Electrical connection across the 0.36 K to 4 K and 4 K to 120 K temperature interfaces is accomplished with lithographed metal wires on dielectric substrates. In the best 25% of winter nights on Mauna Kea, SHARC II is expected to have an NEFD at 350 micron of 1 Jy Hz(sup -1/2) or better. The new camera should be at least 4 times faster at detecting known point sources and 30 times faster at mapping large areas compared to the prior instrument.

Dowell, C. Darren↗

Measurement and Characterization of Helicopter Noise in Steady-State and Maneuvering Flight

A special acoustic flight test program was performed on the Bell 206B helicopter outfitted with an in-flight microphone boom/array attached to the helicopter while simultaneous acoustic measurements were made using a linear ground array of microphones arranged to be perpendicular to the flight path. Air and ground noise measurements were made in steady-state longitudinal and steady turning flight, and during selected dynamic maneuvers. Special instrumentation, including direct measurement of the helicopter s longitudinal tip-path-plane (TPP) angle, Differential Global Positioning System (DGPS) and Inertial Navigation Unit (INU) measurements, and a pursuit guidance display were used to measure important noise controlling parameters and to make the task of flying precise operating conditions and flight track easier for the pilot. Special care was also made to test only in very low winds. The resulting acoustic data is of relatively high quality and shows the value of carefully monitoring and controlling the helicopter s performance state. This paper has shown experimentally, that microphones close to the helicopter can be used to estimate the specific noise sources that radiate to the far field, if the microphones are positioned correctly relative to the noise source. Directivity patterns for steady, turning flight were also developed, for the first time, and connected to the turning performance of the helicopter. Some of the acoustic benefits of combining normally separated flight segments (i.e. an accelerated segment and a descending segment) were also demonstrated.

Schmitz, Fredric H.↗

Research study on stellar X-ray imaging experiment, volume 1

The use of microchannel plates as focal plane readout devices and the evaluation of mirrors for X-ray telescopes applied to stellar X-ray imaging is discussed. The microchannel plate outputs were either imaged on a phosphor screen which was viewed by a low light level vidicon or on a wire array which was read out by digitally processing the output of a charge division network attached to the wires. A service life test which was conducted on two image intensifiers is described.

Wilson, H. H.↗

Installed propfan (SR-7L) far-field noise characteristics

Far-field noise characteristics of the SR-7L single-rotor propfan were obtained from the Propfan Test Assessment (PTA) aircraft flight tests. The aircraft was flown at low altitudes (about 310m) above the ground at a constant speed of about 92 m/sec. The acoustic data were acquired with an array of ground-flush microphones positioned on both sides of the flight path. Propfan-generated noise levels were extracted from the total aircraft noise, and these data were then used to study the far-field noise characteristics. The directivities at the polar and azimuthal planes, and the variations of the blade-order tone levels with propfan power and blade tip Mach number were derived. The effect of inflow angle was studied by changing the nacelle tilt angle. The levels and the directivity were very sensitive to the nacelle tilt angle (i.e., inflow angle). The noise levels in the aft quadrant were found to be higher than in the forward quadrant. Also, the noise levels on the starboard side of the aircraft were found to be higher than on the port side. The noise levels increase with propfan power and rotational speed.

Reddy, N. N.↗

Was the MSSTA 2 mission successful?

The Multi-Spectral Solar Telescope Array (MSSTA) is a rocket borne solar observatory designed to address a wide range of scientific questions relating to two aspects of the structure and dynamics of the solar atmosphere: (1) The heating and dynamics of chromospheric and coronal structures including spicules, coronal loops, bright points, and planes; and the role of the fine scale structure of the chromospheric network in the transport of mass and energy between these structures, and (2) The large scale structures of the corona, including the interface of prominences and filaments with material at coronal temperatures, the transition region structure of coronal holes and plumes, and their relationship to the solar wind. In order to address these fundamental scientific problems, the observational objective of the MSSTA is to obtain a set of high resolution spectroheliograms with the following properties: (1) Sufficiently broad spectral coverage and accurate photometry to allow modeling of structures covering the full range of temperatures observed in non-flaring chromosphere/corona, 10(exp 4) K to 10(exp 7) K; (2) Sufficient spectral resolution (lambda / delta lambda approx. 30-100) in each spectroheliogram to allow isolation of the emission from lines excited over a narrow range of temperatures; (3) To address objective (a), spatial resolution sufficient to resolve structures on the sun on a scale of 100-200 km (0.1-0.3 arc seconds); to address objective (b), images of the full disk and inner corona with resolution at least 1.0 arc second, and high sensitivity images of the extended corona (to approx. 3-4 solar radii above the limb) with resolution of approx. 3 arc seconds; for both objectives (c), direct measurements of the coronal magnetic field. (4) To access the role of non-thermal phenomena in the heating and dynamics of the chromosphere/corona interface, high resolution (lambda / delta lambda greater than 1000) spectroheliograms with spatial resolution of 1-3 arc seconds.

Spencer, Dwight C.↗