Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance loss rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Testing Plant Responses to Rarified Atmospheres for Inflatable Greenhouses

Reduced atmospheric pressures will likely be used to minimize mass and engineering requirements for plant growth habitats used in extraterrestrial applications. A chamber with high vacuum capability was used to design and begin construction of a system for testing plant responses to reduced pressure atmospheres. Several preliminary tests were conducted to evaluate chamber suitability for plant tests and to determine performance of thermal and vacuum systems at ambient and reduced pressure atmospheres down to 0.1 atm. The first tests consisted of measurements of internal gas volume and leakage rate. The method for volume determination was quite sensitive and will be needed for plant gas exchange measurements and calculations. This information will also be used in conjunction with the leak rate. Measured leak rates on the order of 0.46 mm Hg/min at 76 mm Hg pressure are low enough to conduct sensitive carbon dioxide exchange rate measurements at reduced pressure given an adequate plant sample (0.5 to 1.0 sq m area). A test rack with lighting provided by three high-pressure sodium vapor lamps was built to accommodate both short-term and long-term plant responses. Initial short-term experiments with lettuce showed that a pressure of 77 mm Hg resulted in a 6.1-fold increase in the rate of water loss compared to water loss at ambient pressure. Plants were severely wilted after 30 minutes exposure to 77 mm Hg. Water loss was found to be inversely correlated with atmospheric pressure over the range of pressures from 0.2 to 1.0 atm; the rate of water loss at 0.2 atm was 4.3 times higher than water loss at ambient pressure. Older leaves showed moderate wilting during exposure to 156 mm Hg, but those exposed to 345 mm, Hg remained turgid. Results suggest a reduced atmospheric pressure limit of 0.2 to 0.3 atm for lettuce grown in a solid medium. Follow-up experiments with carbon dioxide control and control at high relative humidity (> 90 %) will be needed to further confirm and define safe reduced pressure limits that are feasible for plant tolerance and growth.

Corey, Kenneth A.↗

Mechanistic Insights into the Catalytic Condensation of Methyl Ketones on MgO Surfaces

Ketone coupling via aldol condensation is one of the promising routes to produce cyclic and value-added precursors for renewable hydrocarbon biofuels. A first-principles-based microkinetic modeling is performed to evaluate the surface-mediated reaction mechanisms and the role of water molecules in the observed activities for 2-pentanone and 3-pentanone aldol condensation on dehydroxylated MgO(111) surface and hydroxylated terminated surface[OH-MgO(111)]. Here, we have identified the enhancement of the surface OH group to MgO(111) surface catalytic activity by destabilizing the binding strength of reaction intermediates and reducing the energy barriers of rate-determining steps(proton transfer and dehydration steps). The 2-pentanone has one elementary step less in the complete reaction mechanism of aldol condensation and preferable energy barrier for proton transfer and dehydration steps, revealing 2-pentanone as terminal ketone is more reactive than 3-pentanone as central ketone. The water molecules dominated the OH-MgO( 111) surface after further addition of water, leading to the reduction of turnover frequency of the aldol condensation dimer product as the loss of aldol condensation reaction intermediates in competitive adsorption with water molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tracking performance and cycle slipping in the all-digital symbol synchronizer loop of the block 5 receiver

Computer simulated noise performance of the symbol synchronizer loop (SSL) in the Block 5 receiver is compared with the theoretical noise performance. Good agreement is seen at the higher loop SNR's (SNR(sub L)'s), with gradual degradation as the SNR(sub L) is decreased. For the different cases simulated, cycle slipping is observed (within the simulation time of 10(exp 4) seconds) at SNR(sub L)'s below different thresholds, ranging from 6 to 8.5 dB, comparable to that of a classical phase-locked loop. An important point, however, is that to achieve the desired loop SNR above the seemingly low threshold to avoid cycle slipping, a large data-to-loop-noise power ratio, P(sub D)/(N(sub 0)B(sub L)), is necessary (at least 13 dB larger than the desired SNR(sub L) in the optimum case and larger otherwise). This is due to the large squaring loss (greater than or equal to 13 dB) inherent in the SSL. For the special case of symbol rates approximately equaling the loop update rate, a more accurate equivalent model accounting for an extra loop update period delay (characteristic of the SSL phase detector design) is derived. This model results in a more accurate estimation of the noise-equivalent bandwidth of the loop.

Aung, M.↗

J-2X Abort System Development

The J-2X is an expendable liquid hydrogen (LH2)/liquid oxygen (LOX) gas generator cycle rocket engine that is currently being designed as the primary upper stage propulsion element for the new NASA Ares vehicle family. The J-2X engine will contain abort logic that functions as an integral component of the Ares vehicle abort system. This system is responsible for detecting and responding to conditions indicative of impending Loss of Mission (LOM), Loss of Vehicle (LOV), and/or catastrophic Loss of Crew (LOC) failure events. As an earth orbit ascent phase engine, the J-2X is a high power density propulsion element with non-negligible risk of fast propagation rate failures that can quickly lead to LOM, LOV, and/or LOC events. Aggressive reliability requirements for manned Ares missions and the risk of fast propagating J-2X failures dictate the need for on-engine abort condition monitoring and autonomous response capability as well as traditional abort agents such as the vehicle computer, flight crew, and ground control not located on the engine. This paper describes the baseline J-2X abort subsystem concept of operations, as well as the development process for this subsystem. A strategy that leverages heritage system experience and responds to an evolving engine design as well as J-2X specific test data to support abort system development is described. The utilization of performance and failure simulation models to support abort system sensor selection, failure detectability and discrimination studies, decision threshold definition, and abort system performance verification and validation is outlined. The basis for abort false positive and false negative performance constraints is described. Development challenges associated with information shortfalls in the design cycle, abort condition coverage and response assessment, engine-vehicle interface definition, and abort system performance verification and validation are also discussed.

Santi, Louis M.↗

Low Speed Wind Tunnel Tests on a One-Seventh Scale Model of the H.126 Jet Flap Aircraft

Low speed wind tunnel tests were performed on a one-seventh scale model of the British H.126 jet flap research aircraft over a range of jet momentum coefficients. The primary objective was to compare model aerodynamic characteristics with those of the aircraft, with the intent to provide preliminary data needed towards establishing small-to-full scale correlating techniques on jet flap V/STOL aircraft configurations. Lift and drag coefficients from the model and aircraft tests were found to be in reasonable agreement. The pitching moment coefficient and trim condition correlation was poor. A secondary objective was to evaluate a modified thrust nozzle having thrust reversal capability. The results showed there was a considerable loss of lift in the reverse thrust operational mode because of increased nozzle-wing flow interference. A comparison between the model simulated H.126 wing jet efflux and the model uniform pressure distribution wing jet efflux indicated no more than 5% loss in weight flow rate.

Laub, G. H.↗

Optimization of a Wcl6 CVD System to Coat UO2 Powder with Tungsten

In order to achieve deep space exploration via Nuclear Thermal Propulsion (NTP), Marshall Space Flight Center (MSFC) is developing W-UO2 CERMET fuel elements, with focus on fabrication, testing, and process optimization. A risk of fuel loss is present due to the CTE mismatch between tungsten and UO2 in the W-60vol%UO2 fuel element, leading to high thermal stresses. This fuel loss can be reduced by coating the spherical UO2 particles with tungsten via H2/WCl6 reduction in a fluidized bed CVD system. Since the latest incarnation of the inverted reactor was completed, various minor modifications to the system design were completed, including an inverted frit sublimer. In order to optimize the parameters to achieve the desired tungsten coating thickness, a number of trials using surrogate HfO2 powder were performed. The furnace temperature was varied between 930 C and 1000degC, and the sublimer temperature was varied between 140 C and 200 C. Each trial lasted 73-82 minutes, with one lasting 205 minutes. A total of 13 trials were performed over the course of three months, two of which were re-coatings of previous trials. The powder samples were weighed before and after coating to roughly determine mass gain, and Scanning Electron Microscope (SEM) data was also obtained. Initial mass results indicated that the rate of layer deposition was lower than desired in all of the trials. SEM confirmed that while a uniform coating was obtained, the average coating thickness was 9.1% of the goal. The two re-coating trials did increase the thickness of the tungsten layer, but only to an average 14.3% of the goal. Therefore, the number of CVD runs required to fully coat one batch of material with the current configuration is not feasible for high production rates. Therefore, the system will be modified to operate with a negative pressure environment. This will allow for better gas mixing and more efficient heating of the substrate material, yielding greater tungsten coating per trial.

Belancik, Grace A.↗

Cy-Phy ADS: Cyber Physical Anomaly Detection Framework for EV Charging Systems

Today’s large-scale Electric Vehicle (EV) infrastructures are heavily dependent on information communication technologies to maintain their operation and to support communication within sub-system components as well as the outside world. These technologies are vulnerable to various cyber and physical threats. Timely identification and mitigation of these threats are critical for improving human safety, avoiding economic losses, and preventing catastrophic system failures. By addressing this, our work presents a ResNet Autoencoder (AE) based Cyber-Physical Anomaly Detection System (Cy-Phy ADS) for detecting anomalies in EV Controller Area Network (CAN) protocol communication. It consists of four main components: Cyber-Physical Feature Extractor, ResNet AE-based Anomaly Detection Framework, Cyber-Physical Health Metric (CPHM), and Visualization Dashboard. The presented framework was trained and tested using CAN data collected from the EV charging system testbed at the Idaho National Laboratory. The presented Cy-Phy ADS compared against six widely used unsupervised anomaly detection algorithms: One Class Support Vector Machine (OCSVM), Variational Autoencoder (VAE), LSTM Autoencoder (LSTM AE), Isolation Forest (IForest), Principle Component Analysis (PCA) and Local Outlier Factor (LOF). Here the presented approach showed the highest accuracy among the compared methods. Further, the proposed approach showed comparable performance in terms of precision, F1, and False positive rate. It also showed the lowest training and inference time compared to the neural network-based baseline algorithms compared against with. Additionally, the Cy-Phy ADS has advantages such as unsupervised training, the ability to provide a holistic metric for system health characterization, and non-linear feature extraction.

99 GENERAL AND MISCELLANEOUS↗

Cryogenic Propellant Long-term Storage With Zero Boil-off

Significant boil-off losses of cryogenic propellant storage systems in long-duration space mission applications result in additional propellant and large tanks. The zero boil-off (ZBO) concept consists of an active cryo-cooling system integrated with traditional passive thermal insulation. The potential mass reductions with the ZBO concept are Substantial; therefore, further exploration through technology programs has been initiated within NASA. A large-scale demonstration of the ZBO concept has been devised utilizing the Marshall Space Flight Center (MSFC) Multipurpose Hydrogen Test Bed (MHTB) along with a cryo-cooler unit. The cryo-cooler with the MHTB and spraybar recirculation/mixer system in a manner that enables thermal energy removal at a rate that equals the total tank heat leak. The liquid hydrogen is withdrawn from the tank, passed through a heat exchanger, and then the chilled liquid is sprayed back into the tank through a spraybar. The test series will be performed over a 30-40 day period. Tests will be conducted at multiple fill levels and various mixer operational cycles to demonstrate concept viability and to provide benchmark data to be used in analytical model development. In this paper. analytical models for heat flows through the MHTB tank, cryo-cooler performance. and spraybar performance will be presented.

Hedayat, A.↗

Thermocapillary Flow and Aggregation of Bubbles on a Solid Wall

During the electrolytic evolution of oxygen bubbles forming on a vertically oriented transparent tin oxide electrode, bubbles were found to be mutually attractive. The mechanism of the aggregation had never been explained satisfactorily until Guelcher et al. attributed it to thermocapillary flow. The gradient of surface tension of the liquid at the bubble's surface, which was established because of reaction heat and ohmic heat loss at the electrode wall, drives flow of the liquid adjacent to each bubble; the bubble "pumps" fluid along its surface away from the wall. Fluid flows toward the bubble to conserve mass and entrains nearby bubbles in the flow pattern. The same logic would apply when two bubbles of equal size are adjacent to each other on a warm wall. Each bubble drives thermocapillary flow and hence entrains the other in its flow pattern, which drives the aggregation. Our objective here is to perform experiments where the temperature gradient at the wall is well known and controlled. The theory can be quantitatively tested by studying aggregation of bubble pairs of equal size, and by varying system parameters such as temperature gradient, bubble size and fluid viscosity. The results are then compared with the theory in a quantitatively rigorous manner. We demonstrate that the theory without adjustable parameters is capable of quantitatively modeling the rate of aggregation of two bubbles. The equations governing the thermocapillary flow around a single stationary bubble on a heated or cooled wall in a semi-infinite domain were solved. Both Reynolds number and Marangoni number were much less than unity. The critical result is that liquid in the vicinity of a warm wall flows toward a stationary collector bubble. Consequently the thermocapillary flow around the stationary bubble entrains another bubble toward itself. The bubbles undergo hindered translation parallel to the wall with velocity U while the fluid flow field is described with u. Two velocities were equated by using a wall hindrance parameter q: U = qu [1] which shows the velocity of bubble is proportional to the entraining velocity. The hindrance parameter q can experimentally be measured independently. q can also be calculated by solving the equations of motion for a bubble translating parallel to a solid wall. The experimental cell is cylindrical with an ID of 10 cm and consists of a 1 cm deep main cell filled with silicone oil and flanked by two thermal reservoirs. The upper thermal reservoir was heated and the lower thermal reservoir was cooled so that the bubbles aggregate. Two types of silicone oil (eta = 0.02 and 0.50 Pa s) were used. Two equal sized air bubbles were injected into the cell with a syringe. The center-to-center distance of bubbles was observed through a microscope. Bubble radius ranged from 0.40 mm to 0.65 mm and the temperature gradients along with the cell ranged from 1400 to 5000 K/m. The bubbles aggregated when heat flows from the wall to the fluid. The velocities of bubbles were in the range of 1 - 10 microns/s. The separation r decreased more quickly when the temperature gradient was higher, bubble size was larger, and the oil viscosity was lower. r decreased more rapidly as the bubbles approached each other. Dimensionless time was arbitrarily set to be zero when the dimensionless center-to-center distance between the bubbles was 4. All the bubble trajectories fall onto one line, especially in the range of dimensionless distance from 4 to 3. This means the relative movement of the bubble pair is proportional to the temperature gradient and bubble size and it is inversely proportional to the viscosity of the oil. This result strongly suggests that the thermocapillary flow-based aggregation mechanism is correct. A value of q can be estimated by fitting the scaled data to Eq. [1]. A best fit value of q was obtained as q = 0.26 with a standard deviation of 0.03. Independent experimental results for q for a 0.5 mm radius bubble, give values of q in the range 0.11 to 0.23. The value of q obtained from solving the equations of motion reveals q has values in the range 0.23 - 0.30. Since the full scale of possible values of q is zero to one, the maximum deviation of independently determined values of q from the best fit value was 15% of this full scale. Thus reasonable quantitative agreement between theory and experiment has been obtained.

Kasumi, Hiroki↗

Excerpt from Oxygen Monitor Clean Testing Report Performed in 2010

The Rosemount X-STREAM Series X2GP is a paramagnetic oxygen analyzer with a 0-25% oxygen measurement range. It claims a drift less than 2% of span (0.10% volume oxygen) per week, and a response time of less than 5 seconds (for the analyzer to report 90% of a step change). Our test equipment was set-up such that the same gas was running through each oxygen analyzer at the same time. This allowed Calibration Error, Calibration Drift, and Loss of Power Testing to be run on all monitors at the same time, eliminating any variability between the analyzers from tolerances in the gas cylinder, ambient temperature, ambient pressure, test duration, etc. An APTech pressure regulator was placed on the gas cylinder manifold and a 23 psia Paroscientific pressure transducer measured the regulator’s outlet pressure. This did not give the inlet pressure on any one analyzer but outlet pressure from the manifold before the stream was split. The APTech pressure regulator was used to keep operating conditions consistent. A DWYER rotameter was installed on each oxygen monitor’s outlet piping. With the exception of Variation of Flow Rate Testing, the rotameter was left fully open for all testing. The flow rate through each oxygen monitor was controlled by a Swagelok needle valve that was installed on each analyzer’s inlet piping. Additionally, a filter was installed in the each monitor’s inlet piping to keep particles from the measurement cells and a Swagelok ball valve was installed on each monitor’s outlet piping to isolate each monitor between tests. No pumps were installed. Each of the cylinders used was at a pressure greater than ambient room barometric pressure. This pressure differential was used to move gas through the testing equipment. The flow rate through each analyzer was controlled by the Swagelok needle valve installed on each analyzer’s inlet piping. Finally, for all tests, a Paroscientific Digiquartz Barometer was used to measure ambient room barometric pressure and a Fluke Thermo-hygrometer was used to measure ambient room temperature.

47 OTHER INSTRUMENTATION↗

Effect of area ratio on the performance of a 5.5:1 pressure ratio centrifugal impeller

A centrifugal impeller which was initially designed for a pressure ratio of approximately 5.5 and a mass flow rate of 0.959 kg/sec was tested with a vaneless diffuser for a range of design point impeller area ratios from 2.322 to 2.945. The impeller area ratio was changed by successively cutting back the impeller exit axial width from an initial value of 7.57 mm to a final value of 5.97 mm. In all, four separate area ratios were tested. For each area ratio a series of impeller exit axial clearances was also tested. Test results are based on impeller exit surveys of total pressure, total temperature, and flow angle at a radius 1.115 times the impeller exit radius. Results of the tests at design speed, peak efficiency, and an exit tip clearance of 8 percent of exit blade height show that the impeller equivalent pressure recovery coefficient peaked at a design point area ratio of approximately 2.748 while the impeller aerodynamic efficiency peaked at a lower value of area ratio of approximately 2.55. The variation of impeller efficiency with clearance showed expected trends with a loss of approximately 0.4 points in impeller efficiency for each percent increase in exit axial tip clearance for all impellers tested.

Schumann, L. F.↗

Effect of area ratio on the performance of a 5.5:1 pressure ratio centrifugal impeller

A centrifugal impeller which was initially designed for a pressure ratio of approximately 5.5 and a mass flow rate of 0.959 kg/sec was tested with a vaneless diffuser for a range of design point impeller area ratios from 2.322 to 2.945. The impeller area ratio was changed by successively cutting back the impeller exit axial width from an initial value of 7.57 mm to a final value of 5.97 mm. In all, four separate area ratios were tested. For each area ratio a series of impeller exit axial clearances was also tested. Test results are based on impeller exit surveys of total pressure, total temperature, and flow angle at a radius 1.115 times the impeller exit radius. Results of the tests at design speed, peak efficiency, and an exit tip clearance of 8 percent of exit blade height show that the impeller equivalent pressure recovery coefficient peaked at a design point area ratio of approximately 2.748 while the impeller aerodynamic efficiency peaked at a lower value of area ratio of approximately 2.55. The variation of impeller efficiency with clearance showed expected trends with a loss of approximately 0.4 points in impeller efficiency for each percent increase in exit axial tip clearance for all impellers tested.

Schumann, L. F.↗

Turbulence spreading effects on the ELM size and SOL width

BOUT++ turbulence simulations were performed to investigate the impact of turbulence spreading on the edge localized mode (ELM) size and divertor heat flux width (λ q ) broadening in small ELM regimes. Here, this study is motivated by EAST experiments. BOUT++ linear simulations of a pedestal radial electric field (E r ) scan show that the dominant toroidal number mode (n) shifts from high-n to low-n, with a narrow mode spectrum, and the maximum linear growth rate increases as the pedestal E r well deepens. The nonlinear simulations show that as the net E × B pedestal flow increases, the pressure fluctuation level and its inward penetration beyond the top of the pedestal both increase. This leads to a transition from small ELMs to large ELMs. Both inward and outward turbulence spreading are sensitive to the scrape-off-layer (SOL) plasma profiles. The inward turbulence spreading increases for the steep SOL profiles, leading to increasing pedestal energy loss in the small ELM regime. The SOL width (λ q ) is significantly broadened progressing from the ELM-free to small ELM regime, due to the onset of strong radial turbulent transport. The extent of the SOL width (λ q ) broadening depends strongly on outward turbulence spreading. The fluctuation energy intensity flux Γ ε at the separatrix can be enhanced by increasing either pedestal E r flow shear or local SOL pressure gradient. The λ q is broadened as the fluctuation energy intensity flux Γ ε at the last close flux surface (LCFS) increases. Local SOL E × B flow shear will restrain outward turbulence spreading and the associated heat flux width broadening. Operating in H-mode with small ELMs has the potential to solve two critical problems: reducing the ELM size and broadening the SOL width.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fermilab Booster loss modelling and rebalancing using Bayesian methods

Fermilab Booster is being upgraded for the PIP-II project to support 20Hz ramp rate at higher intensities. Loss trip limits determine the achievable peak power. To meet PIP-II requirements, losses need to be halved as compared to current levels. Losses primarily occur at injection and transition crossing, with both gradually increasing and threshold-like intensity-dependent behaviors. The existing simulation models are not yet good enough for quantitative loss predictions. In practice, it will be necessary to tune up the Booster using iterative methods and operator intuition. In this paper we present an effort to systematically model Booster losses using active learning (Bayesian exploration) techniques, and subsequently to rebalance them for higher trip limit margins. We first created several sets of spatially and temporally isolated orbit and optics knobs, and trained Gaussian process models for each beam loss monitor as well as beam current. This is a complex task due to safety and timing requirements – we discuss mitigations such as uncertainty constraints and approximate fitting. Once models are stable, we perform large-scale single and multi-objective tuning using scalarized objectives made up of critical beam loss locations. Our results demonstrate significant rebalancing of losses, increasing trip margins, as well as an overall improvement in beam transmission efficiency. We are exploring how to combine existing simulations with experimental data and automate the collection procedure so that more advanced surrogate models can be created over time.

Kuklev, Nikita [Fermilab]↗

Modeling Functional Organic Chemistry in Arctic Rivers: An Idealized Siberian System

Rivers of the Arctic will become ever more important for the global climate, since they carry a majority of continental dissolved organic carbon flux into the rapidly changing polar ocean. Aqueous organics comprise a wide array of functional groups, several of which are likely to impact coastal and open water biophysical properties. Light attenuation, interfacial films, aerosol formation, gas release and momentum exchange can all be cited. We performed Lagrangian kinetic modeling for the evolution of riverine organic chemistry as the molecules in question make their way from the highlands to Arctic outlets. Classes as diverse as the proteins, sugars, lipids, re-condensates, humics, bio-tracers and small volatiles are all included. Our reduced framework constitutes an idealized northward flow driving a major hydrological discharge rate and primarily representing the Russian Lena. Mountainous, high solute and tundra sources are all simulated, and they meet up at several points between soil and delta process reactors. Turnover rates are parameterized beginning with extrapolated coastal values imposed along a limited tributary network, with connections between different terrestrial sub-ecologies. Temporal variation of our total dissolved matter most closely resembles the observations when we focus on the restricted removal and low initial carbon loads, suggesting relatively slow transformation along the water course. Thus, channel combinations and mixing must play a dominant role. Nevertheless, microbial and photochemical losses help determine the final concentrations for most species. Chemical evolution is distinct for the various functionalities, with special contributions from pre- and post-reactivity in soil and delta waters. Several functions are combined linearly to represent the collective chromophoric dissolved matter, characterized here by its absorption. Tributaries carry the signature of lignin phenols to segregate tundra versus taiga sources, and special attention is paid to the early then marine behaviors of low molecular weight volatiles. Heteropolycondensates comprise the largest percentage of reactive carbon in our simulations due to recombination/accumulation, and they tend to be preeminent at the mouth. Outlet concentrations of individual structures such as amino acids and absorbers lie above threshold values for biophysical influence, on the monolayer and light attenuation. The extent of coastal spreading is examined through targeted regional box modeling, relying on salinity and color for calibration. In some cases, plumes reach the scale of peripheral arctic seas, and amplification is expected during upcoming decades. Conclusions are mapped from the Lena to other boreal discharges, and future research questions are outlined regarding the bonding type versus mass release as permafrost degrades. Dynamic aqueous organic coupling is recommended for polar system models, from headwaters to coastal diluent.

54 ENVIRONMENTAL SCIENCES↗

Scaling of 100 kW class applied-field MPD thrusters

Three cylindrical applied-field magnetoplasmadynamic thrusters were tested with argon propellant over a broad range of operating conditions to establish empirical scaling laws for thruster performance. Argon flow rates, discharge currents, and applied-field strengths were varied between 0.025 and 0.14 g/s, 750 to 2000 A, and 0.034 to 0.20T, respectively. The results showed that the thrust reached over five times the self-field value, and that thrust increased linearly with the product of discharge current and applied-field strength and quadratically with the anode radius. While increasing the propellant flow rate increased the thrust, it did not affect the rate of thrust increase with applied-field strength, and at low propellant flow rates the self-field thrust approached 30 percent of the measured thrust. The voltage increased linearly with applied-field strength but was insensitive to the discharge current. The rate of voltage increase with applied-field strength dependent on anode radius. Thruster efficiency increased monotonically with applied-field strength and propellant flow rate. Peak thruster efficiencies were insensitive to changes in anode radius. Electrode power loss and thruster efficiency measurements showed that while the electrode losses decreased with increasing anode radius the plasma losses increased. The opposite behaviors of electrode and plasma losses demonstrates the need to identify ways of independently controlling the thruster loss mechanisms.

Myers, Roger M.↗

Intermediate Temperature Stress Rupture of Woven SiC Fiber, BN Interphase, SiC Matrix Composites in Air

Tensile stress-rupture experiments were performed on woven Hi-Nicalon reinforced SiC matrix composites with BN interphases in air. Modal acoustic emission (AE) was used to monitor the damage accumulation in the composites during the tests and microstructural analysis was performed to determine the amount of matrix cracking that occurred for each sample. Fiber fractograph), was also performed for individual fiber failures at the specimen fracture surface to determine the strengths at which fibers failed. The rupture strengths were significantly worse than what would have been expected front the inherent degradation of the fibers themselves when subjected to similar rupture conditions. At higher applied stresses the rate of rupture "?as larger than at lower applied stresses. It was observed that the change in rupture rate corresponded to the onset of through-thickness cracking in the composites themselves. The primary cause of the sen,ere degradation was the ease with which fibers would bond to one another at their closest separation distances, less than 100 nanometers, when exposed to the environment. The near fiber-to-fiber contact in the woven tows enabled premature fiber failure over large areas of matrix cracks due to the stress-concentrations created b), fibers bonded to one another after one or a few fibers fail. i.e. the loss of global load sharing. An@, improvement in fiber-to-fiber separation of this composite system should result in improved stress- rupture properties. A model was den,eloped in order to predict the rupture life-time for these composites based on the probabilistic nature of indin,idual fiber failure at temperature. the matrix cracking state during the rupture test, and the rate of oxidation into a matrix crack. Also incorporated into the model were estimates of the stress-concentration that would occur between the outer rim of fibers in a load-bearing bundle and the unbridged region of a matrix crack after Xia et al. For the lower stresses, this source of stress-concentration was the likely cause for initial fiber failure that would trigger catastrophic failure of the composite.

Morscher, Gregory N.↗

CONSTELL: NASA's Satellite Constellation Model

The CONSTELL program represents an initial effort by the orbital debris modeling group at NASA/JSC to address the particular issues and problems raised by the presence of LEO satellite constellations. It was designed to help NASA better understand the potential orbital debris consequences of having satellite constellations operating in the future in LEO. However, it could also be used by constellation planners to evaluate architecture or design alternatives that might lessen debris consequences for their constellation or lessen the debris effects on other users of space. CONSTELL is designed to perform debris environment projections rapidly so it can support parametric assessments involving either the constellations themselves or the background environment which represents non-constellation users of the space. The projections need to be calculated quickly because a number of projections are often required to adequately span the parameter space of interest. To this end CONSTELL uses the outputs of other NASA debris environment models as inputs, thus doing away with the need for time consuming upfront calculations. Specifically, CONSTELL uses EVOLVE or ORDEM96 debris spatial density results as its background environment, debris cloud snapshot templates to simulate debris cloud propagation, and time dependent orbit profiles of the intact non- functional constellation spacecraft and upper stages. In this paper the environmental consequences of the deployment of particular LEO satellite constellations using the CONSTELL model will be evaluated. Constellations that will undergo a parametric assessment will reflect realistic parameter values. Among other results the increase in loss rate of non-constellation spacecraft, the number of collisions involving constellation elements, and the replacement rate of constellation satellites as a result of debris impact will be presented.

Theall, Jeffrey R.↗