Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peak load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Generic modelling and optimal day-ahead dispatch of micro-energy system considering the price-based integrated demand response

As an extension of micro-grid, micro-energy system (MES) is one of the important carriers for energy utilization in the future, and using energy prices as a controllable resource is conducive to improving the optimization potential of MES. Firstly, based on the energy hub model, a generic method for modelling the steady-state energy balance equation of MES is proposed. Then, considering the multi-energy substitution effect in the background of multi-energy coupling, the concept of price-based integrated demand response (P-IDR) is introduced. Meanwhile, based on the price elasticity theory and the discrete choice theory, the energy timing transfer characteristics and energy substitution characteristics in P-IDR is modelled. Furthermore, after taking into account the P-IDR, an MINLP model for day-ahead dispatch of MES is built, and a generalized benders decomposition method is used for solution. Case studies are conducted on an MES to verify the effectiveness of the proposed modelling method. Here, the result shows that it is beneficial to improve renewable energy accommodation and reduce the peak and off-peak difference of energy load when the P-IDR is deployed. In addition, consider the energy substitution characteristics can reduce the user’s cost on energy purchase and be more in line with the user’s rational consumption behaviour.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nondimensional convection numbers modeling thermally stratified storage tanks: Richardson's number and hot-water tanks

Thermally stratified storage tank studies have spanned over 50 years to increase the thermal storage efficiency and accurate prediction of the outlet temperature particularly for solar applications. The studies have reviewed and modeled the jet and plume flow phenomena inside the tank due to the inlet mixing and stratification level. Kelvin–Helmholtz and Rayleigh–Taylor instabilities are the major drivers of the mixing in these tanks. Momentum jets deflecting off walls at the bottom of the tank also create significant mixing. Reviewing Richardson models shows that the categorization was based on the range of Reynolds numbers at the inlet. Unfortunately, the use of superficial velocity in calculating the Richardson number results in critical values in the literature ranging from below 0.25 to 100. The most used length scale associated with these flows is an inertial scale based on the tank height or diameter although the mixing can occur at a relatively smaller scale. The various inlet devices and a large span of flow rates experienced in thermally stratified storage tanks requisite the use of the Reynolds number in combination with a convection number for accurate one dimensional models that predict performance over the long-term. The evaluation of peak shifting of electric loads leveraging renewable sources for applications, including residential hot-water tanks, commercial water tanks, and large-scale chilled water storage tanks, require these models. Finally, this paper is focused on establishing the significance of the convection numbers in conjunction with the Reynolds number for modeling the thermal stratification in storage tanks.

14 SOLAR ENERGY↗

Too Much of a Good Thing? Global Trends in the Curtailment of Solar PV

Solar photovoltaic (PV) systems generate electricity with no marginal costs or emissions. As a result, PV output is almost always prioritized over other fuel sources and delivered to the electric grid. However, PV curtailment is increasing as PV composes greater shares of grid capacity. In this paper, we present a novel synthesis of curtailment in four key countries: Chile, China, Germany, and the United States. We find that about 6.5 million MWh of PV output was curtailed in these countries in 2018. We find that: Policy and grid planning practices influence where, when, and how much PV is curtailed; Some PV curtailment is attributable to limited transmission capacity connecting remote solar resources to load centers; PV curtailment peaks in the spring and fall, when PV output is relatively high but electricity demand is relatively low. We discuss available measures to reduce PV curtailment as well as increasing PV curtailment in the contexts of evolving grids and energy technologies.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Modeling and simulation performance of sucker rod beam pump

Artificial lift is a mechanism to lift hydrocarbon, generally petroleum, from a well to surface. This is used in the case that the natural pressure from the reservoir has significantly decreased. Sucker rod beam pumping is a method of artificial lift. Sucker rod beam pump is modeled in this research as a function of geometry of the surface part, the size of sucker rod string, and fluid properties. Besides its length, sucker rod string also classified into tapered and un-tapered. At the beginning of this research, for easy modeling, the sucker rod string was assumed as un-tapered. The assumption proved non-realistic to use. Therefore, the tapered sucker rod string modeling needs building. The numerical solution of this sucker rod beam pump model is computed using finite difference method. The numerical result shows that the peak of polished rod load for sucker rod beam pump unit C-456-D-256-120, for non-tapered sucker rod string is 38504.2 lb, while for tapered rod string is 25723.3 lb. For that reason, to avoid the sucker rod string breaks due to the overload, the use of tapered sucker rod beam string is suggested in this research.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Non-contact magnetically coupled rectilinear-rotary oscillations to exploit low-frequency broadband energy harvesting with frequency up-conversion

Ambient vibrations have a rectilinear and broadband nature and are particularly rich in the low-frequency regions. This letter reports an electromagnetic energy harvester to transform low-frequency broadband rectilinear vibrations into electricity with frequency up-conversion. The harvester consists of a rectilinear oscillator and a rotary oscillator coupled through magnetic force induced by four arc permanent magnets centrosymmetrically distributed on each oscillator. The rotary oscillator also includes two repulsive magnets and six stationary coils with steel screws inside to obtain and maintain four equilibrium positions with shallowed potential wells. The magnetic interaction between the rectilinear oscillator and the rotary oscillator is formulated using a magnetic dipole model. The restoring torque induced by the steel screws on the rotor is experimentally measured. Magnetically coupled governing equations are derived and their numerical solutions are used to characterize the dynamic response of the harvester under chirp excitations. Experimental results demonstrate its excellent harvesting capability of scavenging low-frequency wideband vibrational energy under slow-frequency-drifted excitations, simple harmonic excitations, and mixed-frequency excitations. Under harmonic excitations, the rectilinear oscillator vibrates non-harmonically but approximately periodically, while the rotary counterpart oscillates in a more complex pattern varying with the excitation frequency, which leads to the frequency up-conversion (up to 10 times increase) and broadened bandwidth (25% increase from its resonant frequency). Experiments show an output voltage of 5 V (RMS)/40 V (Peak to Peak) and an output power of 55 mW (RMS)/950 mW (Peak) at an optimal load of 465 Ω under harmonic excitation of 4 Hz at 0.7 g.

Deng, Wei (ORCID:0000000194598151)↗

Power balance and divertor asymmetries in the Super-X divertors of MAST-U using SOLPS-ITER

Spherical tokamaks (STs) present unique challenges and opportunities in the area of particle and power exhaust, intensified due to their more compact sizes. Substantial efforts are underway in STs to determine the limits in dissipative operational regimes and advanced divertor solutions, including at MAST-U which provides access to the Super-X divertor configuration. Power balance, and upper/lower divertor asymmetries have been studied using SOLPS-ITER simulations of the MAST-U Super-X divertor. A set of simulations with experimentally inferred transport coefficients with E x B and diamagnetic drifts activated, consisting of density and power scans, and high field side vs low field side gas puff locations, have been used for code experimentation to uncover trends beyond the current experimental parameter space. The upper biased asymmetry (U:L > 1) of the ratio of the peaks of the plasma energy flux densities at the outer targets increases with heating power and decreases with gas puff strength, going from symmetric to up to a factor of 15. The upper target electron temperature has been found to be a good ordering quantity for the magnitude of this asymmetry for all heating powers, gas puff strength, and gas puff locations. The lower divertor biased asymmetry (U:L < 1) of the radiation patterns processed through SOLPS-based bolometry synthetic diagnostics is in qualitative agreement with resistive bolometry experimental results, and it is in quantitative agreement with the trend of the total volume radiation within the divertors of SOLPS. However, radiation measurements alone are not sufficient to infer the magnitude of the asymmetry of the peaks of the power loads at the targets.

MAST-U↗

Nuclear-norm-based Subspace Identification of Multi-Zone Building HVAC System

There have been many attempts to reduce the uncertainty associated with renewable energy. This paper aims to contribute to the field by considering the building heating, ventilation and air conditioning (HVAC) system, which is treated as flexible load. The control of the indoor temperature in the building employing the locally generated renewable energy has been carried out with both model-based and data-driven approaches. Although numerous efforts have been made in the area of construction of a model for the building HVAC system, almost all models have shortcomings. A building model that is locally accurate is required to be able to predict the load consumption in the future. This will benefit both the utility companies and building managers to estimate the upcoming load shape, especially the peak amount and duration. We consider the case of a multi-zone building HVAC system, i.e., each zone has its own thermostat and can be set to a different temperature. Based on our need for a multi-zone model that is locally accurate, we resort to the method of system identification. In particular, we will employ the nuclear norm based subspace identification method.

Telsang, Bhagyashri↗

Dynamic Facade Dashboard v0.1.0

The dashboard is a useful tool for early-stage building design decision-making and communication, as it can help users quickly compare the energy and non-energy related performance of various automated, integrated facade systems using a library of pre-computed data. Users can explore the impacts of various design choices by selecting different facade glazing and shading systems, facade control strategies, and lighting control strategies across multiple climate zones. The dashboard instantly visualizes key metrics, including energy usage in HVAC and lighting, peak cooling and heating load, and daylight availability, allowing immediate trade-off analysis to optimize building efficiency and comfort.

Yu, Tammie [Lawrence Berkeley National Laboratory ↗

Hybrid Ground-Source Heat Pump Installations: Experiences, Improvements, and Tools

One innovation to ground-source heat pump (GSHP, or GHP) systems is the hybrid GSHP (HyGSHP) system, which can dramatically decrease the first cost of GSHP systems by using conventional technology (such as a cooling tower or a boiler) to meet a portion of the peak heating or cooling load. This work uses three case studies (two cooling-dominated, one heating-dominated) to demonstrate the performance of the hybrid approach. Three buildings were studied for a year; the measured data was used to validate models of each system. The models were used to analyze further improvements to the hybrid approach, and establish that this approach has positive impacts, both economically and environmentally. Lessons learned by those who design and operate the systems are also documented, including discussions of equipment sizing, pump operation, and cooling tower control. Finally, the measured data sets and models that were created during this work are described; these materials have been made freely available for further study of hybrid systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Run 16 Tandem gold performance in the injectors and possible improvement with AGS type 6:3:1 bunch merge in the Booster

During Run 16 the Tandem was used as the Gold pre-injector for a brief time so that RHIC could continue running while EBIS was down for repairs. Given the time constraints, the setup was largely derived from the EBIS Au setup. The EBIS Au setup used a 4:2:1 bunch merge in the Booster and a 12:6:2 bunch merge in the AGS.1 This note will describe the Tandem Au setup and compare it to that used for EBIS Au. The bunch merge in the Booster for Tandem Au did not work well, and it seems likely that the performance would’ve been significantly better if it did. An AGS type 6:3:1 merge in the Booster is described which might improve matters.2 Somewhat speculative estimates for the AGS bunch intensity and emittance, if that merge were successful in reducing the Booster extraction emittance to EBIS Au levels, are also given for several potential setups. Using 6 Booster loads from the Tandem, the AGS bunch intensity at extraction reached about 2.5e9 ions with a longitudinal emittance (ε) of about 0.59 eV·s/n.3 Using 12 Booster loads from EBIS, the peak bunch intensity and ε was about 3.1e9 ions and 0.75 eV·s/n, respectively. A 6.4 sec supercycle was used for both at the time, but the Tandem Au supercycle (barring any potential issues with Tandem) could probably have been reduced to about 4.6 sec.

43 PARTICLE ACCELERATORS↗

Load Flexibility Analysis of Residential HVAC and Water Heating and Commercial Refrigeration

The emergence of connected devices and the Internet of Things has opened the door to the concept of widespread use of building equipment for load-side flexibility. This stems from the increased use of distributed and clean energy resources for electric generation and the growing demand for a more resilient and reliable grid. A significant challenge associated with the use of building equipment as a distributed energy resource is quantifying the magnitude of power or energy flexibility. Unlike batteries that have well-defined and relatively constant capacity and maximum charge/discharge rates, building equipment often has characteristics that vary based on external factors (e.g., weather or occupant behavior). This makes quantifying the availability and flexibility of these resources difficult. Controlling a fleet of equipment while minimizing any adverse impacts to the occupants (e.g., discomfort or food spoilage) is a nontrivial matter. Although there are many different control methodologies available, this study focuses on two: priority-based control (PBC) and model-predictive control (MPC). These were selected because they represent two ends of the control spectrum. PBC is a relatively simple control strategy that requires only the current state of the devices to be controlled and an estimate of how much power each device consumes when turned on. MPC is much more complex and requires a model of the system and forecasts of any disturbances that influence the system. Because MPC has a predictive element, it can prepare for a desired response before the event and therefore is expected to provide a more optimal control relative to PBC. Both MPC and PBC are compared with a baseline simulation that uses feedback control typical of the thermostatically controlled devices being evaluated. This report investigates the load flexibility of three building systems: residential air conditioners, residential water heaters, and commercial refrigeration. Air heating and cooling and water heating account for 45% of residential electricity use, making them good candidates for providing load flexibility. Refrigeration in commercial buildings accounts for 16% of commercial building electricity use, making it another good candidate. Simplified models of each system were generated and validated based on measured data from actual equipment. These models were used to simulate the thermal and power response of the systems using PBC and MPC for a fleet of devices trying to achieve a variety of different responses, including hourly load shed, hourly load up, and daily peak demand reduction. Significant findings from each piece of equipment follow.

42 ENGINEERING↗

Peak Demand Impacts From Electricity Efficiency Programs

Quantification of the costs and benefits of electricity efficiency programs have focused largely on the economic value of annual energy reductions. State public utility commissions PUCs and utilities are increasingly interested in assessing peak demand impacts of these programs. The U.S. Energy Information Administration defines peak demand as "The maximum load during a specified period of time." In practice, utilities and grid operators use a wide range of definitions for peak demand. With increasing need for a more flexible and resilient electricity system, and changing costs for generation, utilities and other efficiency program administrators must take into account all characteristics of efficiency programs — including peak demand reduction — to ensure a reliable system at the most affordable cost. In this study, Berkeley Lab explored a new metric, the program administrator (PA) cost of saving peak demand (PA CSPD). We collected data on costs, energy savings and peak demand savings for electricity efficiency programs for 36 investor-owned utilities and other PAs in nine states (Arizona, Arkansas, California, Colorado, Illinois, Massachusetts, Maryland, New York and Texas) for 2014 to 2017. While some utilities report demand reductions for their electricity efficiency programs, there has been little sustained effort in the United States to gather peak demand reduction data or benchmark the cost of achieving peak demand impacts. As a first of its kind analysis, we developed a framework for analyzing peak demand savings across utilities and states and begin to quantify the cost of saving peak demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the Thermal and Moisture Performance of Insulating Shades

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak heating and cooling loads of a home. Over the past 20 years, residential window attachment retrofit technologies have been developed that significantly increase the number of options available to home builders, homeowners, and utilities when considering upgrades of overall window performance. Within the interior window attachments category, honeycomb cellular shades typically have the highest R-values because of their layered or concentric designs. During the winter when the window is fully covered, however, the added insulation reduces the amount of warm indoor air that reaches the window surface, thereby lowering the temperature of the window glass and frame and increasing the potential for condensation to collect on the interior surface of the window. The degree to which this potential is realized depends on the indoor and outdoor conditions as well as the overall thermal resistance of the window and the shades. To examine the condensation buildup potential on the interior surface of the window and the conditions under which this occurs, this report describes experimental research conducted by Pacific Northwest National Laboratory in collaboration with Hunter Douglas, using a a controlled environmental test chamber at the Hunter Douglas facility in Broomfield, Colorado. The results will be used to inform the Attachments Energy Rating Council, which provides energy performance information on all rated window attachments products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sumner County Field Validation: An Assessment of Thermal Energy Storage in Municipal Buildings in Mixed-Humid Climates

The overall aim of the project was to conduct a full-scale implementation of TES in an operational administrative building in Sumner County, Kansas with a special focus of phase change material (PCM) passive implementation in the ceiling envelope. PCM was used with the intention of increasing the ability of public buildings to shift the peak HVAC energy demand and consumption. The study was conducted during the span of three years in 3 phases, (i) phase I: energy audit (pre-retrofit) (ii) phase II: ceiling tile installation (PCM retrofit), and (iii) phase III: energy evaluation (post-retrofit). Temperature and HVAC energy measurements as well as weather data collected is used for an extensive validation study and further parametric assessment to find (a) annual HVAC energy savings (b) peak period electricity and load savings focusing on cooling dominant months of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Range profiles and images of a loaded straight wire

The range-profiles and images of a straight wire without and with lumped impedance loading are discussed and demonstrated. The scattering mechanisms of a straight wire are qualitatively analyzed using the method of moments. Plots of range profiles at different aspect angles show that surface traveling waves are important scattering mechanisms of a straight wire. The presence of traveling wave makes ringlike artifacts appear in the reconstructed images. It was found that lumped impedance loading can effectively distort the range profiles and microwave images of a wire scatterer. In addition, randomly varied reactive loading can generate random peaks in the range profiles.

Li, Hsueh-Jyh↗

PICA Forebody Heatshield Qualification for the Stardust Discovery Class Mission

This paper presents the qualification of the light weight Phenolic Impregnated Carbon Ablators (PICA) as the forebody heatshield for the Stardust Discovery Class Mission. The Stardust spacecraft will be launched in early 1999 and fly by Comet Wild-2 to collect cometary and interstellar dust and return them back to earth in the Sample Return Capsule (SRC). This earth re-entry will be the fastest to date, at 12.6 km/s, and therefore requires a heatshield that can withstand very high heating rates and stagnation pressures, as well as provide the necessary insulation to the vehicle structure. The PICA material was developed as part of the Lightweight Ceramic Ablators program at NASA Ames Research Center, and was baselined as the forebody heatshield because of its low density and superior ablation and thermal performance at severe aerothermodynamic conditions. Under a Small Business Innovative Research (SBIR) program with NASA Ames, Fiber Materials, Inc. developed a process to manufacture a single-piece PICA heatshield for the forebody of the SRC, along with witness material for the fabrication of the test models. The test models were fabricated and instrumented by the staff of Lockheed Martin Astronautics in Denver, Colorado. Full body preliminary aerothermal CFD calculations were performed at NASA Ames to determine the heating and stagnation pressure conditions. The Heat shield sizing was also performed at NASA Ames by using a new material response code that accounts for the highly porous characteristics of the PICA material. The ablation and thermal performance of PICA was qualified in the NASA Ames Interaction Heating Arc Jet Facility. A total of 24 models and four test conditions were used to qualify PICA at the predicted peak heat flux, heat load, shear, and stagnation pressure conditions. Surface and in-depth temperatures were measured using optical pyrometers and thermocouples. Surface recession was measured by using a template and a height gage. Several models were tested to evaluate repair procedures, and two models were cold soaked in liquid nitrogen, prior th testing, to investigate the effect of the cold space environment on the performance of the material. In addition, material cored from a demonstration single-piece heatshield was tested to verify that the PICA process can be successfully completed on a large, complex heatshield shape.

Tran, Huy K.↗

Diaplectic Glass Content in Experimentally Shock-loaded Quartz Determined by X-Ray Powder Diffraction

Quartz is the most common mineral of terrestrial crustal rocks and thus a widespread indicator for impact cratering and associated shock metamorphism. Planar deformation features (PDFs) are among the most prominent and diagnostic shock features in quartz and they represent thin lamellae of glass that formed via solid-state transformations. This socalled 'diaplectic' glass becomes pervasive at higher pressures and results in optically isotropic and X-ray-amorphous phases that resemble texturally the original quartz grains (without evidence of melt flow). In the past, it has been shown that the amount of this amorphous material in experimentally shock-loaded quartz correlates with peak shock pressure. Both reports derive the glass content from density measurements of individual crystals employing the equation X(%) = (rho(sub x) - rho(sub 0))/(rho(sub x) - rho(sub gl)), where x and 0 stands for X-ray and average (optical) density, respectively. The density of glass, rho(sub gl), was adopted as 2.2 g/cu cm. Though the same procedures had been applied, the resulting glass content differs significantly among the above studies. In the present study, we are using a new approach based solely on the integral intensity of a single, carefully selected reflection in the XRD pattern, and we will compare our data to those reported in the literature.

Skala, R.↗

Ares I-X Upper Stage Simulator Structural Analyses Supporting the NESC Critical Initial Flaw Size Assessment

The structural analyses described in the present report were performed in support of the NASA Engineering and Safety Center (NESC) Critical Initial Flaw Size (CIFS) assessment for the ARES I-X Upper Stage Simulator (USS) common shell segment. The structural analysis effort for the NESC assessment had three thrusts: shell buckling analyses, detailed stress analyses of the single-bolt joint test; and stress analyses of two-segment 10 degree-wedge models for the peak axial tensile running load. Elasto-plastic, large-deformation simulations were performed. Stress analysis results indicated that the stress levels were well below the material yield stress for the bounding axial tensile design load. This report also summarizes the analyses and results from parametric studies on modeling the shell-to-gusset weld, flange-surface mismatch, bolt preload, and washer-bearing-surface modeling. These analyses models were used to generate the stress levels specified for the fatigue crack growth assessment using the design load with a factor of safety.

Knight, Norman F., Jr.↗