Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “panel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Recent development in the design, testing and impact-damage tolerance of stiffened composite panels

Structural technology of laminated filamentary-composite stiffened-panel structures under combined inplane and lateral loadings is discussed. Attention is focused on: (1) methods for analyzing the behavior of these structures under load and for determining appropriate structural proportions for weight-efficient configurations; and (2) effects of impact damage and geometric imperfections on structural performance. Recent improvements in buckling analysis involving combined inplane compression and shear loadings and transverse shear deformations are presented. A computer code is described for proportioning or sizing laminate layers and cross-sectional dimensions, and the code is used to develop structural efficiency data for a variety of configurations, loading conditions, and constraint conditions. Experimental data on buckling of panels under inplane compression is presented. Mechanisms of impact damage initiation and propagation are described.

Williams, J. G.↗

Simulated hail impact testing of photovoltaic solar panels

Techniques used to simulate and study the effect of hail on photovoltaic solar panels are described. Simulated hail stones (frozen ice spheres projected at terminal velocity) or steel balls were applied by air guns, gravity drop, or static loading. Tests with simulated hail and steel balls yielded different results. The impact strength of 10 commercially available flat-plate photovoltaic modules was tested. It was found that none of the six panel designs incorporating clear potting silicone material as the outermost layer remained undamaged by 1-in. simulated hailstones, while a photovoltaic module equipped with a 0.188-in.-thick acrylic cover sheet would be able to withstand the impact of a 2-in.-diameter hailstone.

Moore, D.↗

Improved Woodward's panel method for calculating edge suction forces

A new technique to improve Woodward's (1968) unified subsonic and supersonic panel method is described. The pressure prediction is improved based on a new two-dimensional theory. The method used by Lan (1977) is then used to calculate the leading-edge and side-edge suction forces by direct use of the predicted pressure distribution. The method is applicable to both subsonic and supersonic flow. It is shown that the improved Woodward panel method is capable of accurately predicting leading-edge and side-edge suction forces in subsonic and supersonic flow. Therefore, the method can be used not only to predict the vortex lift of complex planforms through the method of suction analogy, but also to calculate some lateral-directional stability derivatives.

Lan, C. E.↗

Testing panels in tension and flexure

Simple jig adapts tensile test machine for simulataneous application of tension and flexure, for evaluating panel composition, processing, and design. Environmental test chamber can be added so that panel properties can be measured at extreme temperatures.

Jing, G. K.↗

Heat pipes cool probe and sandwich panel

Two concepts integrate heat-pipe technology. Probe with heat-pipe cooled jacket is self-contained, passive, and has no moving parts, unlike conventional air and water cooled probes. It is used in hostile, high temperature environments like wind tunnels and powerplants or on high-speed research and hypersonic cruise vehicles. Heat-pipe sandwich panel combines structural efficiency of sandwich with thermal efficiency of heat-pipe. It is used to eliminate thermal gradients and stresses, minimize thermal distortions, and transfer heat from one face of panel to other.

Camarda, C. J.↗

An improved Woodward's panel method for calculating leading-edge and side-edge suction forces at subsonic and supersonic speeds

Woodward's panel method for subsonic and supersonic flow was improved by employing control points determined by exactly matching two-dimensional pressure at a finite number of points. The results show great improvement in the predicted pressure distribution of a flapped airfoil. With the paneling scheme of cosine law in both chordwise and spanwise directions, the method is shown to accurately predict leading edge and side edge suction forces of various configurations in subsonic and supersonic flow.

Lan, C. E.↗

Solar maximum mission panel jettison analysis remote manipulator system

A study is presented of the development of the Remote Manipulator System (RMS) configurations for jettison of the solar panels on the Solar Maximum Mission/Multimission Satellite. A valid RMS maneuver between jettison configurations was developed. Arm and longeron loads and effector excursions due to the solar panel jettison were determined to see if they were within acceptable limits. These loads and end effector excursions were analyzed under two RMS modes, servos active in position hold submode, and in the brakes on mode.

Bauer, R. B.↗

Aluminium or copper substrate panel for selective absorption of solar energy

A method for making panels which selectively absorb solar energy is disclosed. The panels are comprised of an aluminum substrate, a layer of zinc thereon, a layer of nickel over the zinc layer and an outer layer of solar energy absorbing nickel oxide or a copper substrate with a layer of nickel thereon and a layer of solar energy absorbing nickel oxide distal from the copper substrate.

Roberts, M. L.↗

A general panel method for the analysis and design of arbitrary configurations in incompressible flows

A method for solving the linear integral equations of incompressible potential flow in three dimensions is presented. Both analysis (Neumann) and design (Dirichlet) boundary conditions are treated in a unified approach to the general flow problem. The method is an influence coefficient scheme which employs source and doublet panels as boundary surfaces. Curved panels possessing singularity strengths, which vary as polynomials are used, and all influence coefficients are derived in closed form. These and other features combine to produce an efficient scheme which is not only versatile but eminently suited to the practical realities of a user-oriented environment. A wide variety of numerical results demonstrating the method is presented.

Johnson, F. T.↗

Proposed method for determining the thickness of glass in solar collector panels

An analytical method was developed for determining the minimum thickness for simply supported, rectangular glass plates subjected to uniform normal pressure environmental loads such as wind, earthquake, snow, and deadweight. The method consists of comparing an analytical prediction of the stress in the glass panel to a glass breakage stress determined from fracture mechanics considerations. Based on extensive analysis using the nonlinear finite element structural analysis program ARGUS, design curves for the structural analysis of simply supported rectangular plates were developed. These curves yield the center deflection, center stress and corner stress as a function of a dimensionless parameter describing the load intensity. A method of estimating the glass breakage stress as a function of a specified failure rate, degree of glass temper, design life, load duration time, and panel size is also presented.

Moore, D. M.↗

Buckling and postbuckling research on flat and curved composite panels

Progress in the development of verified design technology for generic advanced-composite structural components loaded in compression is reported. Generic structural configurations material systems and load ranges of interest for a given application were investigated using structural procedures, structural analysis procedures, and laboratory testing of structural specimens. Both flat and curved composite compression panels that are designed either to be buckling resistant or to have postbuckling strength depending on the expected application of the panels were considered.

Starnes, J. H., Jr.↗

Design and analysis of a stiffened composite fuselage panel

The design and analysis of stiffened composite panel that is representative of the fuselage structure of existing wide bodied aircraft is discussed. The panel is a minimum weight design, based on the current level of technology and realistic loads and criteria. Several different stiffener configurations were investigated in the optimization process. The final configuration is an all graphite/epoxy J-stiffened design in which the skin between adjacent stiffeners is permitted to buckle under design loads. Fail safe concepts typically employed in metallic fuselage structure have been incorporated in the design. A conservative approach has been used with regard to structural details such as skin/frame and stringer/frame attachments and other areas where sufficient design data was not available.

Dickson, J. N.↗

A computer model of solar panel-plasma interactions

High power solar arrays for satellite power systems are presently being planned with dimensions of kilometers, and with tens of kilovolts distributed over their surface. Such systems face many plasma interaction problems, such as power leakage to the plasma, particle focusing, and anomalous arcing. These effects cannot be adequately modeled without detailed knowledge of the plasma sheath structure and space charge effects. Laboratory studies of 1 by 10 meter solar array in a simulated low Earth orbit plasma are discussed. The plasma screening process is discussed, program theory is outlined, and a series of calibration models is presented. These models are designed to demonstrate that PANEL is capable of accurate self consistant space charge calculations. Such models include PANEL predictions for the Child-Langmuir diode problem.

Cooke, D. L.↗

Metallic Panels Would Insulate at 2,700 Degrees F

Multiwall metallic panels now under development as replacements for ceramic surface-insulation tiles of Space Shuttle could eventually be used in other aircraft, possibly even as thermal protection in ground-based applications. Various configurations of basic multilayer sandwich are expected to protect against temperatures ranging from 700 degrees to 2,700 degrees F (370 degrees -1, 480 degrees C). With assistance from heat-pipe cooling, panels should withstand temperature to 3,500 degrees F (1,930 degrees C); however, heat pipes would not exceed 1,600 degrees F (870 degrees C).

Jackson, R. L.↗

Calculation of two dimensional vortex/surface interference using panel methods

The application of panel methods to the calculation of vortex/surface interference characteristics in two dimensional flow was studied over a range of situations starting with the simple case of a vortex above a plane and proceeding to the case of vortex separation from a prescribed point on a thick section. Low order and high order panel methods were examined, but the main factor influencing the accuracy of the solution was the distance between control stations in relation to the height of the vortex above the surface. Improvements over the basic solutions were demonstrated using a technique based on subpanels and an applied doublet distribution.

Maskew, B.↗

Outgassing tests on iras solar panel samples

Several outgassing tests were carried out on representative solar panel samples in order to determine the extent of contamination that could be expected from this source. The materials for the construction of the solar panels were selected as a result of contamination obtained in micro volatile condensable materials tests.

Premat, G.↗

Development of assembly techniques for fire resistant aircraft interior panels

Ten NASA Type A fire resistant aircraft interior panels were fabricated and tested to develop assembly techniques. These techiques were used in the construction of a full scale lavatory test structure for flame propagation testing. The Type A panel is of sandwich construction consisting of Nomex honeycomb filled with quinone dioxime foam, and bismaleimide/glass face sheets bonded to the core with polyimide film adhesive. The materials selected and the assembly techniques developed for the lavatory test structure were designed for obtaining maximum fire containment with minimum smoke and toxic emission.

Lee, S. C. S.↗