Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “movement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Yap1/Taz are essential for the liver development in zebrafish

Highlights: • Taz is significantly up-regulated in zebrafish yap1 mutants. • yap1{sup −/−}; taz{sup +/−} embryos are defective in digestive organs development. • Mutations in yap1{sup −/−}; taz{sup +/−} impair cell proliferation in liver and movement of LPM. • Taz can substituteYap1's function in liver development in zebrafish. Hippo pathway regulates cell proliferation and differentiation. Yes-associated protein (Yap) and transcriptional coactivator with PDZ-binding motif (Taz) are effectors of Hippo pathway. The function of Yap/Taz in embryonic liver development has yet to be reported. Here yap1 and taz were found expressed in liver and other digestive organs in zebrafish embryos, and knockout of yap1 or taz did not lead to visible defects during embryogenesis. Interestingly, Taz was significantly increased in yap1 mutants, which may account for their normal development, albeit losing Yap1. However, yap1{sup −/−}; taz{sup +/-} embryos exhibited smaller digestive organs, and more than half of them showed bilateral livers and pancreas and non-looped intestines. Further analysis revealed that the disrupted gene function in yap1{sup −/−}; taz{sup +/-} embryos did not disturb liver bud formation, but instead impaired cell proliferation in liver and movement of the neighboring lateral plate mesoderm (LPM). Overexpression of wild type yap1 or taz could rescue the defective liver phenotypes in yap1{sup −/−}; taz{sup +/-} embryos, indicating that Yap1 cooperate with Taz to regulate the liver development. In addition, Yap1 was found to function in a Tead-dependent manner in the liver development. Our results suggest that Yap1/Taz regulate LPM movement and promote cell proliferation to ensure proper liver development in zebrafish.

60 APPLIED LIFE SCIENCES↗

Brassinosteroid reduces ABA accumulation leading to the inhibition of ABA-induced stomatal closure

Highlights: • ABA strengthened BL-induced stomatal closure. • Expression of OST1 was induced by BL, and BL-induced stomatal closure required OST1. • Inhibition of ABA-induced stomatal closure by BR was due to reduced ABA accumulation. Proper regulation of stomatal movement in response to various environmental stresses or developmental status is critical for the adaptation of many plant species to land. In plants, abscisic acid (ABA)-induced stomatal closure is a well-adapted method of regulating water status. In addition to ABA, we previously showed that plant-specific steroidal hormone, brassinosteroid (BR), also induces stomatal closure; however, BR modulates ABA-induced stomatal closure negatively at high concentrations. In this study, we further investigated the cross-talk between ABA and BR in relation to stomatal movement. In contrast to previous reports that ABA-induced stomatal closure was inhibited by brassinolide (BL), the most active BR, we showed that BL-induced stomatal closure was enhanced by ABA, indicating that the sequence of ABA or BL treatments led to different results. We found that this phenomenon occurred because the guard cells still had the capacity to be closed further by ABA, as the degree of stomatal closure by BL was always less than that by ABA. We also found that BL-induced stomatal closure required Open Stomata 1 (OST1) activity and the induced expression of OST1 was indifferent to the sequence of ABA and/or BL treatments. In addition, we examined the underlying mechanism by which inhibition of ABA-induced stomatal closure by BL occurred. We revealed that the downregulation of ABA-biosynthetic genes by BL resulted in a lower accumulation of ABA. These results suggested that the regulation of stomatal movement is finely controlled by the combined effects of plant hormones, ABA and BR.

60 APPLIED LIFE SCIENCES↗

Closed- and open-state models of human skeletal muscle sodium channel

Highlights: • Closed- and open-state models of hNav1.4 are shown. • The incomplete outward movement of S4 of domain III holds the channel closed. • The presence of intermediate state in S4 outward movement is revealed. • Movement of ∼6.5 elementary charges is required to activate the channel from hyperpolarized state. • Beta-scorpion toxin Ts1 binds to the closed-state model. Voltage-gated sodium channels play important roles in human physiology. However, their complexity hinders the understanding of their physiology and pathology at atomic level. We took advantage of the structural reports of similar channels obtained by cryo-EM (EeNav1.4, and NavPaS), and constructed models of human Nav1.4 channels at closed and open states. The open-state model is very similar to the recently published cryo-EM structure of hNav1.4. The comparison of both models shows shifts of the voltage sensors (VS) of DIII and DIV. The activated position of VS-DII in the closed model was demonstrated by Ts1 docking, thereby confirming the requirement that VS-DI, VS-DII and VS-DIII must be activated for the channel to open. The interactions observed with VS-DIII suggest a stepwise, yet fast, transition from resting to activated state. These models provide structural insights on the closed-open transition of the channel.

60 APPLIED LIFE SCIENCES↗

Thermally induced cracking on the massive concrete structure of the NSLS II synchrotron and its engineering remediation

Synchrotron accelerator facilities such as the NSLS II require extreme stability, both transient (short-term) and quasi-static (long-term) to achieve the desired resolution performance. Consequently, even μm-level movements, particularly differential movements between locations in the concrete structure supporting the accelerator electron beam lattice (storage ring) or high sensitivity experiments (experimental floor) will lead to serious degradation of its performance. Differential settlement in the overall structure or structural movement exceeding anticipated levels will inevitably degrade the performance and will require intervention. Presented in this paper are the design philosophy of the NSLS II ring structure favoring a monolithic ring, the observed cracking behavior of the young NSLS II concrete following casting and in combination with extreme ambient temperature fluctuation, the results of a non-linear, high-fidelity numerical analysis used to emulate the observed cracking and establish the driving mechanism, the numerical analysis-based identification of the crack-arresting solution and finally the implementation of the remediation solution and the long-term performance of the adopted engineering solution. The multi-stage process revealed that computational methods such as non-linear finite element methods have the potential of providing engineering guidance even when complex structures and in combination with non-linear materials, such as steel reinforcement and concrete are involved.

42 ENGINEERING↗

Intrafraction Geometric Uncertainties in Frameless Image-Guided Radiosurgery

Purpose: Frameless radiosurgery allows the possibility of intrafraction patient movement. Because radiosurgery delivers the entire radiation dose during one or a few fractions, intrafraction misalignment can result in significant underdosage of the treatment site. This article compares alignment errors and their effect on target coverage for treatments that rely only on initial (fixed) alignment vs. those that make intrafraction corrections (dynamic alignment). Methods and Materials: This study analyzed 577 records of intrafraction patient movement observed during frameless cranial and spinal radiosurgery. For each fraction, the average misalignment per fraction was calculated. Then each fraction was divided into n minifractions and margin formulae developed for hyperfractionated radiotherapy were used to estimate the planning margin that would be necessary to preserve target coverage for the observed intrafraction movement. Results: Dynamic alignment reduced the number of fractions with a mean misalignment greater than 2 mm from approximately 20% to nearly zero. For fixed alignment, the estimated margins for optimal target coverage were 3.6-4.5 mm for the various treatment sites. For dynamic alignment, the optimal margins were 1.2-1.6 mm. Conclusions: The estimated margins show the large influence of systematic intrafraction shifts and the capacity of dynamic alignment to correct for them. For dynamic alignment, the margin approximately equates with the traditional precision tolerances for radiosurgery, whereas for fixed alignment, the margin is three times greater. Although these margins may not be directly applicable to radiosurgery planning, they expose the effects of intrafraction motion on target coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Distribution in Bladder and Surrounding Normal Tissues in Relation to Bladder Volume in Conformal Radiotherapy for Bladder Cancer

Purpose: To estimate bladder movements and changes in dose distribution in the bladder and surrounding tissues associated with changes in bladder filling and to estimate the internal treatment margins. Methods and Materials: A total of 16 patients with bladder cancer underwent planning computed tomography scans with 80- and 150-mL bladder volumes. The bladder displacements associated with the change in volume were measured. Each patient had treatment plans constructed for a 'partially empty' (80 mL) and a 'partially full' (150 mL) bladder. An additional plan was constructed for tumor irradiation alone. A subsequent 9 patients underwent sequential weekly computed tomography scanning during radiotherapy to verify the bladder movements and estimate the internal margins. Results: Bladder movements were mainly observed cranially, and the estimated internal margins were nonuniform and largest (>2 cm) anteriorly and cranially. The dose distribution in the bladder worsened if the bladder increased in volume: 70% of patients (11 of 16) would have had bladder underdosed to <95% of the prescribed dose. The dose distribution in the rectum and intestines was better with a 'partially empty' bladder (volume that received >70%, 80%, and 90% of the prescribed dose was 23%, 20%, and 15% for the rectum and 162, 144, 123 cm{sup 3} for the intestines, respectively) than with a 'partially full' bladder (volume that received >70%, 80%, and 90% of the prescribed dose was 28%, 24%, and 18% for the rectum and 180, 158, 136 cm{sup 3} for the intestines, respectively). The change in bladder filling during RT was significant for the dose distribution in the intestines. Tumor irradiation alone was significantly better than whole bladder irradiation in terms of organ sparing. Conclusion: The displacements of the bladder due to volume changes were mainly related to the upper wall. The internal margins should be nonuniform, with the largest margins cranially and anteriorly. The changes in bladder filling during RT could influence the dose distribution in the bladder and intestines. The dose distribution in the rectum and bowel was slightly better with a 'partially empty' than with a 'full' bladder.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Converging Stereotactic Radiotherapy Using Kilovoltage X-Rays: Experimental Irradiation of Normal Rabbit Lung and Dose-Volume Analysis With Monte Carlo Simulation

Purpose: To validate the feasibility of developing a radiotherapy unit with kilovoltage X-rays through actual irradiation of live rabbit lungs, and to explore the practical issues anticipated in future clinical application to humans through Monte Carlo dose simulation. Methods and Materials: A converging stereotactic irradiation unit was developed, consisting of a modified diagnostic computed tomography (CT) scanner. A tiny cylindrical volume in 13 normal rabbit lungs was individually irradiated with single fractional absorbed doses of 15, 30, 45, and 60 Gy. Observational CT scanning of the whole lung was performed every 2 weeks for 30 weeks after irradiation. After 30 weeks, histopathologic specimens of the lungs were examined. Dose distribution was simulated using the Monte Carlo method, and dose-volume histograms were calculated according to the data. A trial estimation of the effect of respiratory movement on dose distribution was made. Results: A localized hypodense change and subsequent reticular opacity around the planning target volume (PTV) were observed in CT images of rabbit lungs. Dose-volume histograms of the PTVs and organs at risk showed a focused dose distribution to the target and sufficient dose lowering in the organs at risk. Our estimate of the dose distribution, taking respiratory movement into account, revealed dose reduction in the PTV. Conclusions: A converging stereotactic irradiation unit using kilovoltage X-rays was able to generate a focused radiobiologic reaction in rabbit lungs. Dose-volume histogram analysis and estimated sagittal dose distribution, considering respiratory movement, clarified the characteristics of the irradiation received from this type of unit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Motion and Targeting Accuracy in Robotic Spinal Radiosurgery: 260 Single-Fraction Fiducial-Free Cases

Purpose: To evaluate clinical targeting precision and assess patient movement data during fiducial-free, single-fraction spinal radiosurgery with the Cyberknife (CK). Methods and Materials: Image-guided spine tracking accuracy was tested using two phantoms. Movement patterns (three translations, roll, pitch and yaw) were obtained from log files of 260 patient treatments (47 cervical, 89 thoracic, 90 lumbar, and 34 pelvic/sacral). For two treatments (average and maximum motion scenario), we added offsets to all beams according to recorded patient movements and recalculated the delivered dose distribution to simulate the dosimetric impact of intrafraction motion. Results: Phantom spine position was registered with an accuracy of <0.2 mm for translational and <0.3{sup o} for rotational directions. Residual patient motion yielded mean targeting errors per beam of 0.28 {+-} 0.13 mm (X), 0.25 {+-} 0.15 mm (Y), 0.19 {+-} 0.11 mm (Z) and 0.40 {+-} 0.20{sup o} (roll), 0.20 {+-} 0.08{sup o} (pitch), and 0.19 {+-} 0.08{sup o} (yaw). Spine region had little influence on overall targeting error, which was <1 mm for more than 95% of treatments (median, 0.48 mm). In the maximum motion case, target coverage decreased by 1.7% (from 92.1% to 90.4%) for the 20-Gy prescription isodose. Spinal cord volume receiving more than 8 Gy increased slightly, from 2.41 to 2.46 cm{sup 3}. Conclusions: Submillimeter targeting precision was obtained for fiducial-free spinal radiosurgery despite patient motion. Patient motion has little effect on the delivered dose distribution when image-guided correction of beam aiming is employed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rectal Motion in Patients Receiving Preoperative Radiotherapy for Carcinoma of the Rectum

Purpose: To assess the movement of rectum, mesorectum, and rectal primary during a course of preoperative chemoradiotherapy. Methods and Materials: Seventeen patients with Stage II or III rectal cancer had a planning CT scan with rectal contrast before commencement of preoperative chemoradiation. The scan was repeated during Weeks 1, 3, and 5 of chemoradiation. The rectal primary (gross tumor volume), rectum, mesorectum, and bladder were contoured on all four scans. An in-house biomechanical model-based deformable image registration technique, Morfeus, was used to measure the three-dimensional spatial change in these structures after bony alignment. The required planning target volume margin for this spatial change, after bone alignment, was also calculated. Results: Rectal contrast was found to introduce a systematic error in the position of all organs compared with the noncontrast state. The largest change in structures during radiotherapy was in the anterior and posterior directions for the mesorectum and rectum and in the superior and inferior directions for the gross tumor volume. The planning target volume margins required for internal movement for the mesorectum based on the three scans acquired during treatment are 4 mm right, 5 mm left, 7 mm anterior, and 6 mm posterior. For the rectum, values were 8 mm right, 8 mm left, 8 mm anterior, and 9 mm posterior. The greatest movement of the rectum occurred in the upper third. Conclusions: Contrast is no longer used in CT simulation. Assuming bony alignment, a nonuniform margin of 8 mm anteriorly, 9 mm posteriorly, and 8 mm left and right is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Antiflatulent Dietary Advice on Intrafraction Motion for Prostate Cancer Radiotherapy

Purpose: To evaluate the effect of an antiflatulent dietary advice on the intrafraction prostate motion in patients treated with intensity-modulated radiotherapy (IMRT) for prostate cancer. Methods and Materials: Between February 2002 and December 2009, 977 patients received five-beam IMRT for prostate cancer to a dose of 76 Gy in 35 fractions combined with fiducial markers for position verification. In July 2008, the diet, consisting of dietary guidelines to obtain regular bowel movements and to reduce intestinal gas by avoiding certain foods and air swallowing, was introduced to reduce the prostate motion. The intrafraction prostate movement was determined from the portal images of the first segment of all five beams. Clinically relevant intrafraction motion was defined as {>=}50% of the fractions with an intrafraction motion outside a range of 3 mm. Results: A total of 739 patients were treated without the diet and 105 patients were treated with radiotherapy after introduction of the diet. The median and interquartile range of the average intrafraction motion per patient was 2.53 mm (interquartile range, 2.2-3.0) without the diet and 3.00 mm (interquartile range, 2.4-3.5) with the diet (p < .0001). The percentage of patients with clinically relevant intrafraction motion increased statistically significant from 19.1% without diet to 42.9% with a diet (odds ratio, 3.18; 95% confidence interval, 2.07-4.88; p < .0001). Conclusions: The results of the present study suggest that antiflatulent dietary advice for patients undergoing IMRT for prostate cancer does not reduce the intrafraction movement of the prostate. Therefore, antiflatulent dietary advice is not recommended in clinical practice for this purpose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Lung Tumor Motion in a Large Sample: Patterns and Factors Influencing Precise Delineation of Internal Target Volume

Purpose/Objective: To evaluate lung tumor motion during respiration and to describe factors affecting the range and variability of motion in patients treated with stereotactic ablative radiation therapy. Methods and Materials: Log file analysis from online respiratory tumor tracking was performed in 145 patients. Geometric tumor location in the lungs, tumor volume and origin (primary or metastatic), sex, and tumor motion amplitudes in the superior-inferior (SI), latero-lateral (LL), and anterior-posterior (AP) directions were recorded. Tumor motion variability during treatment was described using intrafraction/interfraction amplitude variability and tumor motion baseline changes. Tumor movement dependent on the tumor volume, position and origin, and sex were evaluated using statistical regression and correlation analysis. Results: After analysis of >500 hours of data, the highest rates of motion amplitudes, intrafraction/interfraction variation, and tumor baseline changes were in the SI direction (6.0 ± 2.2 mm, 2.2 ± 1.8 mm, 1.1 ± 0.9 mm, and −0.1 ± 2.6 mm). The mean motion amplitudes in the lower/upper geometric halves of the lungs were significantly different (P<.001). Motion amplitudes >15 mm were observed only in the lower geometric quarter of the lungs. Higher tumor motion amplitudes generated higher intrafraction variations (R=.86, P<.001). Interfraction variations and baseline changes >3 mm indicated tumors contacting mediastinal structures or parietal pleura. On univariate analysis, neither sex nor tumor origin (primary vs metastatic) was an independent predictive factor of different movement patterns. Metastatic lesions in women, but not men, showed significantly higher mean amplitudes (P=.03) and variability (primary, 2.7 mm; metastatic, 4.9 mm; P=.002) than primary tumors. Conclusion: Online tracking showed significant irregularities in lung tumor movement during respiration. Motion amplitude was significantly lower in upper lobe tumors; higher interfraction amplitude variability indicated tumors in contact with mediastinal structures, although adhesion to parietal pleura did not necessarily reduce tumor motion amplitudes. The most variable lung tumors were metastatic lesions in women.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deployment of portable, modular gas samplers as part of an atmospheric tracer experiment

Underground nuclear explosions release noble gases into the atmosphere that can be detected to support international monitoring efforts. Atmospheric transport models help predict the movement of these gases over long distances, but struggle to predict the movement in the atmosphere local to the release. A field experiment was designed to monitor the movement of 127 Xe within a 5-km radius. Four gas samplers were deployed as part of this experiment to collect atmospheric samples at various distances from the release point. In conclusion, these samples were then analyzed in a near-field lab using a NaI detector and in an off-site lab using gamma-gamma coincidence and beta-gamma coincidence counting.

Radioxenon↗

Dynamic in-situ imaging of methane hydrate formation and self-preservation in porous media

Here we present the results of dynamic in-situ 3D X-ray imaging of methane hydrates microstructure during methane hydrate formation and dissociation in sand samples. Short scanning times and high resolution provided by synchrotron X-rays allowed for better understanding of water movement and different types of gas-hydrate formation. Complementing previous observations, we conclude that the process of gas-hydrate formation is accompanied by the water movements caused by cryogenic water suction that happens in sequences of short fast movements with longer equilibrium states in between (when the water is immobile). Based on the 3D microstructure we identified two distinct types of gas-hydrate formation: (i) into the gas pockets and (ii) inside water volumes. For both mechanisms we do not see problems in gas or water supply to support the gas-hydrate formation. The rate of dissociation in the self-preservation mode (pressure drop at negative temperatures) appears to be different for these two types of gas hydrates. This means that the history of the gas-hydrate formation may influence its behaviour at the dissociation stage (e.g. gas-hydrate production).

58 GEOSCIENCES↗

Effects of strain amplitude and temperature on the damping capacity of an Fe-19Mn alloy with different microstructures

The influences of strain amplitude (10{sup -5}-10{sup -4}) and temperature (25 deg. C-500 deg. C) on the internal friction of a cold-drawn and solution treated Fe-19Mn alloy were investigated. The internal friction was measured using reversal torsion pendulum and multifunction internal friction equipment. The microstructure was observed using scanning electron microscopy. The phase transformation temperatures were determined using differential scanning calorimetry. The results indicated that the internal friction of the solution treated alloy was related to strain amplitude, which could be explained using the movement of Shockley partial dislocations (bowing out and breaking away). But the internal friction of the cold-drawn alloy was independent of strain amplitude because of high density dislocations formed by cold forming. Moreover, when the temperature was changed between 25 deg. C and 500 deg. C, the internal friction of the cold-drawn alloy increased slowly from 25 deg. C to 375 deg. C, and then increased quickly from 375 deg. C to 500 deg. C. However, for the solution treated alloy, there was an internal friction peak at about 210 deg. C in the heating process (from 25 deg. C to 500 deg. C), and there was another internal friction peak at about 150 deg. C in the cooling process. These peaks could be explained using the heat-assisted movement of dislocations. - Research Highlights: {yields}Internal friction of solution treated Fe-19Mn alloy is related to strain amplitude. {yields}Internal friction of cold-drawn Fe-19Mn alloy is independent of strain amplitude. {yields}IF of cold-drawn alloy increases from RT to 500 deg. C. {yields}There is an IF peak of solution treated alloy in heating and cooling process separately. {yields}The results can be explained using the movement of dislocations.

36 MATERIALS SCIENCE↗

Negative influence of rafted γ′ phases on 750 °C/750 MPa creep in a Ni-based single crystal superalloy with 4% Re addition

Highlights: • The negative influence of the rafted γ′ phases on creep was investigated. • The rafted sample exhibited a lower creep rate a shorter rupture life. • Fine γ′ phases impeded first the dislocation movement in γ matrix. • Existed superdislocations and the stress release decreased the creep resistance. • Rafted γ′ phases were more easily cut by superdislocations and stacking faults. - Abstract: Specimens with two different γ′ phase microstructures, named as-heat treated sample with cuboidal γ′ phases and pre-rafted sample with N-type rafted γ′ phases, were compared to investigate the negative influence of the rafted γ′ phases on the creep property in a Ni-based single crystal superalloy with 4% Re addition at 750 °C and 750 MPa condition. The results indicated that the sample with cuboidal γ′ phases exhibited a lower creep rate and a longer rupture life compared to that with rafted γ′ phases. Transmission electron microscope examinations showed that lots of fine γ′ phases impeded first the dislocation movement in the channel of γ matrix in the initial primary creep stage before the cuboidal γ′ phases were cut by stacking faults in as-heat treated sample. However, in pre-rafted sample, some existed superdislocations located in rafted γ′ phases and the mismatch stress release at γ/rafted γ′ interface resulting from pre-rafted treatment not only decreased the creep resistance of rafted γ′ phases, but also weakened the γ/rafted γ′ interface pinning effect for dislocation movement. Therefore, the rafted γ′ phases were easily cut by superdislocations and stacking faults resulting in a higher creep rate and a shorter creep life.

36 MATERIALS SCIENCE↗

Rotation of the Sacrum During Bellyboard Pelvic Radiotherapy

Patients with cervical, uterine, and rectal carcinomas are usually treated in the prone position using the bellyboard positioning device. Specific and uncomfortable prone position gives rise to uncertainties in the daily set-up of patients during the treatment. During investigation of translational movements, rotational movements of the pelvis are observed and investigated. The film portal imaging is used to discover patient positioning errors during treatment. We defined the rotational set-up errors by angle deviations of the sacrum. Thirty-six patients were included in the study; 15 patients were followed during the whole treatment and 21 during the first 5 consecutive treatment days. The image acquisitions were completed in 84%. Systematic and random positioning errors were analyzed in 725 images. Approximately half of the patients had adjusted to the bellyboard in the first few fractions, with sacrum angles remaining the same for the rest of the treatment. The other half had drifts of the sacrum angle during the whole treatment. The rotation of the sacrum during treatment ranged up to 14 deg., causing the usual set-up verification and correction procedure to result in errors up to 15 mm. Rotational movements of the patient pelvis during bellyboard pelvis radiotherapy can introduce considerable patient position error.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of setup error using different reference images: a phantom and lung cancer patients study

The purpose of this study was to compare setup errors obtained with kilovoltage cone-beam computed tomography (CBCT) and 2 different kinds of reference images, free-breathing 3D localization CT images (FB-CT) and the average images of 4-D localization CT images (AVG-CT) for phantom and lung cancer patients. This study also explored the correlation between the difference of translational setup errors and the gross tumor volume (GTV) motion. A respiratory phantom and 14 patients were enrolled in this study. For phantom and each patient, 3D helical CT and 4D CT images were acquired, and AVG-CT images were generated from the 4D CT. The setup errors were determined based on the image registration between the CBCT and the 2 different reference images, respectively. The data for both translational and rotational setup errors were analyzed and compared. The GTV centroid movement as well as its correlation with the translational setup error differences was also evaluated. In the phantom study, the AVG-CT method was more accurate than the FB-CT method. For patients, the translational setup errors based on FB-CT were significantly larger than those from AVG-CT in the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) directions (p < 0.05). Translational setup errors differed by >1 mm in 32.6% and >2 mm in 12.9% of CBCT scans. The rotational setup errors from FB-CT were significantly different from those from AVG-CT in the LR and AP directions (p < 0.05). The correlation coefficient of the translational setup error differences and the GTV centroid movement in the LR, SI, and AP directions was 0.515 (p = 0.060), 0.902 (p < 0.001), and 0.510 (p = 0.062), respectively. For lung cancer patients, respiration may affect the on-line target position location. AVG-CT provides different reference information than FB-CT. The difference in SI direction caused by the 2 methods increases with the GTV movement. Therefore, AVG-CT should be the prefered choice of reference images.

61 RADIATION PROTECTION AND DOSIMETRY↗

A quantitative assessment of volumetric and anatomic changes of the parotid gland during intensity-modulated radiotherapy for head and neck cancer using serial computed tomography

To evaluate the change in volume and movement of the parotid gland measured by serial contrast-enhanced computed tomography scans in patients with head and neck cancer treated with parotid-sparing intensity-modulated radiotherapy (IMRT). A prospective study was performed on 13 patients with head and neck cancer undergoing dose-painted IMRT to 69.96 Gy in 33 fractions. Serial computed tomography scans were performed at baseline, weeks 2, 4, and 6 of radiotherapy (RT), and at 6 weeks post-RT. The parotid volume was contoured at each scan, and the movement of the medial and lateral borders was measured. The patient's body weight was recorded at each corresponding week during RT. Regression analyses were performed to ascertain the rate of change during treatment as a percent change per fraction in parotid volume and distance relative to baseline. The mean parotid volume decreased by 37.3% from baseline to week 6 of RT. The overall rate of change in parotid volume during RT was−1.30% per fraction (−1.67% and−0.91% per fraction in≥31 Gy and<31 Gy mean planned parotid dose groups, respectively, p = 0.0004). The movement of parotid borders was greater in the≥31 Gy mean parotid dose group compared with the<31 Gy group (0.22% per fraction and 0.14% per fraction for the lateral border and 0.19% per fraction and 0.06% per fraction for the medial border, respectively). The median change in body weight was−7.4% (range, 0.75% to−17.5%) during RT. A positive correlation was noted between change in body weight and parotid volume during the course of RT (Spearman correlation coefficient, r = 0.66, p<0.01). Head and neck IMRT results in a volume loss of the parotid gland, which is related to the planned parotid dose, and the patient's weight loss during RT.

61 RADIATION PROTECTION AND DOSIMETRY↗