Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “modal test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Analysis and simulation of the MAST (COFS-1 flight hardware)

In-house analysis work in support of the Control of Flexible Structures (COFS) program is being performed at the NASA Langley Research Center. The work involves evaluation of the proposed design configuration, controller design as well as actuator dynamic modeling, and MAST/actuator dynamic simulation of excitation and damping. A complete finite element model of the MAST has been developed. This finite element model has been incorporated into an optimization procedure which minimizes total mass while maintaining modal coupling. Results show an increase in the total mass due to additional constraints (namely, the diagonal frequency constraint) imposed on the baseline design. A valid actuator dynamic model is presented and a complete test sequence of the proposed flight experiment is demonstrated. The actuator dynamic model is successfully used for damping and the stroke limitations for first mode excitation are demonstrated. Plans are to incorporate additional design variables and constraints into the optimization procedure (such as actuator location) and explore alternative formulations of the objective function. A different actuator dynamic model to include hardware limitations will be investigated.

Horta, Lucas G.↗

An overview of controls research on the NASA Langley Research Center grid

The NASA Langley Research Center has assembled a flexible grid on which control systems research can be accomplished on a two-dimensional structure that has many physically distributed sensors and actuators. The grid is a rectangular planar structure that is suspended by two cables attached to one edge so that out of plane vibrations are normal to gravity. There are six torque wheel actuators mounted to it so that torque is produced in the grid plane. Also, there are six rate gyros mounted to sense angular motion in the grid plane and eight accelerometers that measure linear acceleration normal to the grid plane. All components can be relocated to meet specific control system test requirements. Digital, analog, and hybrid control systems capability is provided in the apparatus. To date, research on this grid has been conducted in the areas of system and parameter identification, model estimation, distributed modal control, hierarchical adaptive control, and advanced redundancy management algorithms. The presentation overviews each technique and presents the most significant results generated for each area.

Montgomery, Raymond C.↗

Nonlinear Reduced-Order Simulation Using An Experimentally Guided Modal Basis

A procedure is developed for using nonlinear experimental response data to guide the modal basis selection in a nonlinear reduced-order simulation. The procedure entails using nonlinear acceleration response data to first identify proper orthogonal modes. Special consideration is given to cases in which some of the desired response data is unavailable. Bases consisting of linear normal modes are then selected to best represent the experimentally determined transverse proper orthogonal modes and either experimentally determined inplane proper orthogonal modes or the special case of numerically computed in-plane companions. The bases are subsequently used in nonlinear modal reduction and dynamic response simulations. The experimental data used in this work is simulated to allow some practical considerations, such as the availability of in-plane response data and non-idealized test conditions, to be explored. Comparisons of the nonlinear reduced-order simulations are made with the surrogate experimental data to demonstrate the effectiveness of the approach.

Rizzi, Stephen A.↗

Digital Astronaut Project Biomechanical Models: Biomechanical Modeling of Squat, Single-Leg Squat and Heel Raise Exercises on the Hybrid Ultimate Lifting Kit (HULK)

The NASA Digital Astronaut Project (DAP) implements well-vetted computational models to predict and assess spaceflight health and performance risks, and to enhance countermeasure development. The DAP Musculoskeletal Modeling effort is developing computational models to inform exercise countermeasure development and to predict physical performance capabilities after a length of time in space. For example, integrated exercise device-biomechanical models can determine localized loading, which will be used as input to muscle and bone adaptation models to estimate the effectiveness of the exercise countermeasure. In addition, simulations of mission tasks can be used to estimate the astronaut's ability to perform the task after exposure to microgravity and after using various exercise countermeasures. The software package OpenSim (Stanford University, Palo Alto, CA) (Ref. 1) is being used to create the DAP biomechanical models and its built-in muscle model is the starting point for the DAP muscle model. During Exploration missions, such as those to asteroids and Mars, astronauts will be exposed to reduced gravity for extended periods. Therefore, the crew must have access to exercise countermeasures that can maintain their musculoskeletal and aerobic health. Exploration vehicles may have very limited volume and power available to accommodate such capabilities, even more so than the International Space Station (ISS). The exercise devices flown on Exploration missions must be designed to provide sufficient load during the performance of various resistance and aerobic/anaerobic exercises while meeting potential additional requirements of limited mass, volume and power. Given that it is not practical to manufacture and test (ground, analog and/or flight) all candidate devices, nor is it always possible to obtain data such as localized muscle and bone loading empirically, computational modeling can estimate the localized loading during various exercise modalities performed on a given device to help formulate exercise prescriptions and other operational considerations. With this in mind, NASA's Digital Astronaut Project (DAP) is supporting the Advanced Exercise Concepts (AEC) Project, Exercise Physiology and Countermeasures (ExPC) laboratory and NSBRI-funded researchers by developing and implementing well-validated computational models of exercises with advanced exercise device concepts. This report focuses specifically on lower-body resistance exercises performed with the Hybrid Ultimate Lifting Kit (HULK) device as a deliverable to the AEC Project.

health↗

Automated Registration of Multi-Mode Nondestructive Evaluation Data

Registration techniques play a central role in applications of image processing to computer vision, medical imaging, and automatic target tracking. Feature-based techniques such as scale-invariant feature transform (SIFT) and speeded up robust features (SURF) are commonly used to register images derived from a single modality. However, SIFT and SURF struggle to register images from different modalities because the features tend to manifest rather differently and at sometimes very different length-scales. The most successful methods that have been developed to register multi-modal data use information-theoretic approaches. These methods play a key part in nondestructive evaluation scenarios where data that is collected by sensors of different modalities must be registered to be fused. In this paper, automated registration based on normalized mutual information is applied to align data derived from ultrasonic and radiographic inspections of (i) additively manufactured titanium alloy test coupons, and (ii) thin, lithium metal pouch-cell batteries. The quality of the registration is quantified in terms of computational resources and spatial accuracy. In the first case the X-ray computed tomography (XCT) data is captured on a region corresponding to a small subset of the ultrasonic data, while in the case of the lithium batteries the digital radiography (DR) captures a larger region of interest than the ultrasonic data. In both cases the radiographic data resolution is much higher than for ultrasound, but interestingly, in both cases the accuracy of the registration is approximately equal to two-to-three-pixel lengths in the ultrasonic images.

Nondestructive Evaluation↗

Wireless Sensor Modalities at a Nuclear Plant Site to Collect Vibration Data

One of the major contributors to the total operating costs of domestic nuclear fleet of reactors today is the operation and maintenance (O&M) costs. These include labor-intense preventive maintenance programs involving manually-performed inspection, calibration, testing, and maintenance of plant assets at periodic frequency and time-based replacement of assets at periodic frequency, irrespective of their conditions. This has resulted in a labor-centric business model to achieve high capacity factors. To build an optimal maintenance program, it’s time to transition from this labor-centric business model to a technology-centric business model. Fortunately, there are technologies (advanced sensor, data analytics, and risk assessment methodologies) that will support this transition. The technology-centric business model will result in significant plant life extension and reduction of time-based maintenance activities. This will drive down O&M costs as labor is a rising cost and technology is a declining cost. This approach will lay the foundation for real-time condition assessment of plant assets, allowing condition-based maintenance to enhance plant safety, reliability, and economics of operation. The goal of this project is to address challenges in the area of digital monitoring, i.e., the application of advanced sensor technologies (particularly wireless sensor technologies) and science-based data analytic capabilities to advance online monitoring and predictive maintenance in nuclear plants to improve plant performance (efficiency gain and economic competitiveness). To achieve the project goal, in partnership with Exelon Generating Company (Exelon), researchers from Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) are performing research and development (R&D) to demonstrate application of wireless sensors using the distributed antenna system and advanced data analytics to achieve predictive maintenance. In the report, wireless vibration sensors, vibration data and its indicator are described. The wireless vibration sensors presented in this report support three types of wireless communication, namely, Wi-Fi, cellular, and 900 MHz. These wireless vibration sensors are considered by partner plant site for installation on plant asset to enable online vibration monitoring to replace periodic measurements. These vibration data along with other plant process data will be utilized to develop diagnostic and prognostic models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probabilistic system identification in the time domain

The objective of system identification is to determine reliable dynamical models of a structure by systematically using its measured excitation and response. It brings together in an integrated fashion, experimental, analytical, and computational techniques in structural dynamics. Areas of application for system identification include the following: (1) Model Evaluation--assessing assumptions (linearity and equivalent viscous damping) and techniques (finite-element modeling) used to construct theoretical models of a structure; (2) Model Improvement--updating of a theoretical model to enable more accurate response predictions for possible future loads on the structure, or for control of the structure; (3) Empirical Modelling--developing empirical relationships (nonlinear models) or empirical parameter values (modal damping) because the present state of the art does not provide theoretical results; and (4) Damage Detection and Assessment--continual or episodic updating of a structural model through vibration monitoring to detect and locate any structural damage. It can be argued that since the construction or modification of models using test data is subject to inherent uncertainties, the above problems should be properly treated within a Bayesian probabilistic framework. Such a methodology is presented which allows the precision of the estimates of the model parameters to be computed. It also leads to a guiding principle in applications. Namely, when selecting a single model from a given class of models, one should take the most probable model in the class based on the experimental data. Practical applications of this principle are given which are based on the utilization of measured seismic motions in large civil structures. Examples include the application of a computer program MODE-ID to identify modal properties directly from seismic excitation and response time histories from a nine-story steel-frame building at JPL and from a freeway overpass bridge.

Beck, James L.↗

Modal Correction Method For Dynamically Induced Errors In Wind-Tunnel Model Attitude Measurements

This paper describes a method for correcting the dynamically induced bias errors in wind tunnel model attitude measurements using measured modal properties of the model system. At NASA Langley Research Center, the predominant instrumentation used to measure model attitude is a servo-accelerometer device that senses the model attitude with respect to the local vertical. Under smooth wind tunnel operating conditions, this inertial device can measure the model attitude with an accuracy of 0.01 degree. During wind tunnel tests when the model is responding at high dynamic amplitudes, the inertial device also senses the centrifugal acceleration associated with model vibration. This centrifugal acceleration results in a bias error in the model attitude measurement. A study of the response of a cantilevered model system to a simulated dynamic environment shows significant bias error in the model attitude measurement can occur and is vibration mode and amplitude dependent. For each vibration mode contributing to the bias error, the error is estimated from the measured modal properties and tangential accelerations at the model attitude device. Linear superposition is used to combine the bias estimates for individual modes to determine the overall bias error as a function of time. The modal correction model predicts the bias error to a high degree of accuracy for the vibration modes characterized in the simulated dynamic environment.

Buehrle, R. D.↗

Prospects for in vivo estimation of photon linear attenuation coefficients using postprocessing dual-energy CT imaging on a commercial scanner: Comparison of analytic and polyenergetic statistical reconstruction algorithms

Purpose: Accurate patient-specific photon cross-section information is needed to support more accurate model-based dose calculation for low energy photon-emitting modalities in medicine such as brachytherapy and kilovoltage x-ray imaging procedures. A postprocessing dual-energy CT (pDECT) technique for noninvasivein vivo estimation of photon linear attenuation coefficients has been experimentally implemented on a commercial CT scanner and its accuracy assessed in idealized phantom geometries. Methods: Eight test materials of known composition and density were used to compare pDECT-estimated linear attenuation coefficients to NIST reference values over an energy range from 10 keV to 1 MeV. As statistical image reconstruction (SIR) has been shown to reconstruct images with less random and systematic error than conventional filtered backprojection (FBP), the pDECT technique was implemented with both an in-house polyenergetic SIR algorithm, alternating minimization (AM), as well as a conventional FBP reconstruction algorithm. Improvement from increased spectral separation was also investigated by filtering the high-energy beam with an additional 0.5 mm of tin. The law of propagated uncertainty was employed to assess the sensitivity of the pDECT process to errors in reconstructed images. Results: Mean pDECT-estimated linear attenuation coefficients for the eight test materials agreed within 1% of NIST reference values for energies from 1 MeV down to 30 keV, with mean errors rising to between 3% and 6% at 10 keV, indicating that the method is unbiased when measurement and calibration phantom geometries are matched. Reconstruction with FBP and AM algorithms conferred similar mean pDECT accuracy. However, single-voxel pDECT estimates reconstructed on a 1 × 1 × 3 mm{sup 3} grid are shown to be highly sensitive to reconstructed image uncertainty; in some cases pDECT attenuation coefficient estimates exhibited standard deviations on the order of 20% around the mean. Reconstruction with the statistical AM algorithm led to standard deviations roughly 40% to 60% less than FBP reconstruction. Additional tin filtration of the high energy beam exhibits similar pDECT estimation accuracy as the unfiltered beam, even when scanning with only 25% of the dose. Using the law of propagated uncertainty, low Z materials are found to be more sensitive to image reconstruction errors than high Z materials. Furthermore, it is estimated that reconstructed CT image uncertainty must be limited to less than 0.25% to achieve a target linear-attenuation coefficient estimation uncertainty of 3% at 28 keV. Conclusions: That pDECT supports mean linear attenuation coefficient measurement accuracies of 1% of reference values for energies greater than 30 keV is encouraging. However, the sensitivity of the pDECT measurements to noise and systematic errors in reconstructed CT images warrants further investigation in more complex phantom geometries. The investigated statistical reconstruction algorithm, AM, reduced random measurement uncertainty relative to FBP owing to improved noise performance. These early results also support efforts to increase DE spectral separation, which can further reduce the pDECT sensitivity to measurement uncertainty.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multi-harmonic RF test stand for RF breakdown studies

A multi-harmonic RF test stand is under construction at Yale Beam Physics Laboratory. It includes a frequency multiplier which can generate high power harmonics efficiently that are phase locked to the fundamental drive frequency. In a bi-modal asymmetric cavity powered by this RF source, the cavity may experience reduced exposure time to peak fields and sweeping of peak fields across their surfaces, and strong asymmetry between surfaces that may experience cathode-and anode-like fields; these phenomena are to be assessed for their influence on RF breakdown probabilities.

43 PARTICLE ACCELERATORS↗

THE MILKY WAY TOMOGRAPHY WITH SDSS. III. STELLAR KINEMATICS

We study Milky Way kinematics using a sample of 18.8 million main-sequence stars with r < 20 and proper-motion measurements derived from Sloan Digital Sky Survey (SDSS) and POSS astrometry, including {approx}170,000 stars with radial-velocity measurements from the SDSS spectroscopic survey. Distances to stars are determined using a photometric-parallax relation, covering a distance range from {approx}100 pc to 10 kpc over a quarter of the sky at high Galactic latitudes (|b|>20{sup 0}). We find that in the region defined by 1 kpc <Z< 5 kpc and 3 kpc <R< 13 kpc, the rotational velocity for disk stars smoothly decreases, and all three components of the velocity dispersion increase, with distance from the Galactic plane. In contrast, the velocity ellipsoid for halo stars is aligned with a spherical coordinate system and appears to be spatially invariant within the probed volume. The velocity distribution of nearby (Z < 1 kpc) K/M stars is complex, and cannot be described by a standard Schwarzschild ellipsoid. For stars in a distance-limited subsample of stars (<100 pc), we detect a multi-modal velocity distribution consistent with that seen by HIPPARCOS. This strong non-Gaussianity significantly affects the measurements of the velocity-ellipsoid tilt and vertex deviation when using the Schwarzschild approximation. We develop and test a simple descriptive model for the overall kinematic behavior that captures these features over most of the probed volume, and can be used to search for substructure in kinematic and metallicity space. We use this model to predict further improvements in kinematic mapping of the Galaxy expected from Gaia and the Large Synoptic Survey Telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

Time-of-Flight Estimation for Nondestructive Evaluation

Ultrasonic testing (UT) for nondestructive evaluation (NDE) is a critical entity necessary to resolve both the quality and precision questions of complex parts evolving from the classical approaches to the innovative additive manufacturing (AM) process. This modality provides the essential quantitative information for acceptance and potential flaw detectionof apart under investigation. A primary ingredient in UT besides the required precision robotic hardware for theacquisition of high-qualitymeasurement data is the underlying signal processing. It is here that much of the system performance capability resides. In this report,we discuss the basic steps in UT signal processing along with current capabilities that must be achieved in order to satisfy the criticaldemands of the various LLNL programs.In itsbasic foundations, signal processing is essentially the “extraction of critical information (signals) from noisy, uncertain data.” Clearly, in a perfect world the best signal processing is none---just make a reliable, noise-free, uncertainty-free, measurement. Unfortunately, even the best of systems is still straddled within the confines and limitations of physical instrumentation. With this in mind, we discuss the development of signal processing techniques toextract the desired UT information from noisy measurement data. We start with a discussion of a simple homogeneous representation of a “part” under investigation and its insonification by an ultrasonicexcitation from a physics-based perspective. Once developed, we briefly discussthe various choices of excitation signals and their tradeoffs.Next,we discuss a simulation approach employing simple models from the signal processing perspective and then move on to the development of the basic signal processing approach to ultrasonic signal processing all based on estimating the pulse arrival estimation. Starting with simple peak detection techniques, progressing to the processing workhorse so-called “matched-filter” and finally to the more sophisticated “model-based matched filter.”The underlying pre-and post-processing of noisy measurement data along with the application of these techniques are subsequently demonstrated on experimental ultrasonic data.Finally, we present some results for processing “weld” data when the ultrasonic excitation signal is not directly available.

42 ENGINEERING↗

Aircraft interior noise models - Sidewall trim, stiffened structures, and cabin acoustics with floor partition

As part of the continuing development of an aircraft interior noise prediction model, in which a discrete modal representation and power flow analysis are used, theoretical results are considered for inclusion of sidewall trim, stiffened structures, and cabin acoustics with floor partition. For validation purposes, predictions of the noise reductions for three test articles (a bare ring-stringer stiffened cylinder, an unstiffened cylinder with floor and insulation, and a ring-stringer stiffened cylinder with floor and sidewall trim) are compared with measurements.

Pope, L. D.↗

A layered abduction model of perception: Integrating bottom-up and top-down processing in a multi-sense agent

A layered-abduction model of perception is presented which unifies bottom-up and top-down processing in a single logical and information-processing framework. The process of interpreting the input from each sense is broken down into discrete layers of interpretation, where at each layer a best explanation hypothesis is formed of the data presented by the layer or layers below, with the help of information available laterally and from above. The formation of this hypothesis is treated as a problem of abductive inference, similar to diagnosis and theory formation. Thus this model brings a knowledge-based problem-solving approach to the analysis of perception, treating perception as a kind of compiled cognition. The bottom-up passing of information from layer to layer defines channels of information flow, which separate and converge in a specific way for any specific sense modality. Multi-modal perception occurs where channels converge from more than one sense. This model has not yet been implemented, though it is based on systems which have been successful in medical and mechanical diagnosis and medical test interpretation.

Josephson, John R.↗

Fan Noise Control Using Herschel-quincke Resonators

The research effort proposed for this NASA NRA is mainly experimental. In addition, Virginia Tech is working in partnership with Goodrich Aerospace, Aerostructures Group for the analytical development needed to support the experimental endeavor, i.e. model development, design, and system studies. In this project, Herschel-Quincke (HQ)liner technology experiments will be performed at the NASA Glenn Active Noise Control Fan (ANCF) facility. A schematic of both inlet and aft HQ-liner systems installed in the ANCF rig as well as a picture of the Glenn facility is shown. The main goal is to simultaneously test in both the inlet and bypass duct sections. The by-pass duct will have HQ-systems in both the inner and outer duct walls. The main advantages of performing tests at the ANCF facility are that the effect of the inlet HQ-system on the by-pass HQ-system and vice versa, can be accurately determined from the in-duct modal data. Another significant advantage is that it offers the opportunity to assess (on a common basis) the proposed noise reduction concept on the ANCF rig which in the past has been used for assessing other active and passive noise reduction strategies.

Burdisso, Ricardo A.↗

Calculated and Measured Dose Distributions in an Anthropomorphic RANDO Phantom - Paper 105

Patient-specific quality assurance (QA) is a major component of the Intensity Modulated Radiation Therapy (IMRT) clinical process. The objective of this often time-intensive measurement process is to verify that the prescribed dose is accurately delivered to the target volume while sparing surrounding healthy tissue. The IMRT dose distributions can be measured using a wide variety of techniques and measurement devices including film (radiographic and radiochromic), ion chamber arrays, diode arrays, and Electronic Portal Imaging Devices (EPIDs). Of all the available modalities, film is one of the most versatile and most frequently utilized measurement systems. In rotation delivery techniques (such as volume modulated arc therapy and helical tomotherapy), composite dose distributions are obtained by irradiating a test phantom containing dosimeter(s). When film is utilized as the dosimeter, it can be placed in coronal, sagittal, or transverse planes inside the phantom. Because the film is irradiated using the rotational delivery sequence used to treat the patient, the dose given to specific anatomical structures (such as the parotids, spinal cord, bladder, rectum etc...) can be evaluated. Thomas et al (Med Phys 32: 3793-3800) recently reported the results of IMRT verifications for ten patients planned and treated with helical tomotherapy. This study reported that nearly 92% of the film pixels within the analyzed region of interest were within a gamma criterion of 2 mm and 2%. Like most tomotherapy users, Thomas et al used a test phantom made of homogeneous water equivalent material. Heterogeneous phantoms that simulate the different tissue densities in the human body do exist, but are infrequently used for patient-specific IMRT QA. The potential advantage of using heterogeneous phantoms is that the measured dose distributions will more adequately reflect the clinical dose distributions in the patients. The use of homogenous phantoms during IMRT quality assurance can potentially mask errors that arise from limitations in the treatment planning system's modeling of density corrections. The purpose of this study was to evaluate the dosimetric accuracy of a helical tomotherapy system using an anthropomorphic RANDO phantom (The Phantom Laboratory, Salem, NY) for patient-specific QA. The results of this study will allow a benchmark to be established for dosimetric accuracy in heterogeneous materials. Performing patient-specific QA is an integral part of the IMRT patient treatment process. Test phantoms are typically homogeneous, and do test the treatment planning systems ability to account for heterogeneity corrections. In this study, an anthropomorphic RANDO phantom was used to evaluate the doses calculated by a helical tomotherapy system. The dosimetric agreement between calculated and measured was worse than published results in homogenous phantoms, especially for target volumes located in the lung. Further investigation will be needed to determine if these errors are due to film response at heterogeneous tissue interfaces or from actual dose calculation errors. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-415: An Ionization Chamber Array with High Spatial Resolution for External Beam Radiotherapy

Purpose: To characterize an ionization chamber array technology with high spatial resolution and high charge collection efficiency for external beam radiotherapy. Methods: The prototype under test is a linear array of air vented ionization chambers developed by IBA Dosimetry, consisting of 80 pixels with 3.5mm spatial resolution and 4mm{sup 3} sensitive volume. The detector was characterized in a plastic phantom with {sup 60} Co radiation and MV X-rays from an ELEKTA Agility LINAC (with flattened and unflattened beam qualities). Bias voltage was varied in order to evaluate charge collection efficiency. A commercial array of ionization chambers (MatriXX Evolution, IBA Dosimetry) and an amorphous silicon flat panel in direct conversion configuration were used as references. Results: Repeatability (0.4%) and stability under continuous gamma irradiation (0.3%) are very good, in spite of low active volume and sensitivity (∼200pC/Gy). Charge collection efficiency is higher than 99% already at 150V with ∼2mGy dose per pulse, leading to a ±1.1% sensitivity change with dose per pulse in the range 0.09-2mGy (covering all flattened and unflattened applications). Measured dose profiles are in agreement with MatriXX for fields larger than 2×2cm{sup 2}, in which case the linear array offers a much better characterization of the penumbra region. Down to 1×1cm{sup 2}, measured profiles are in very good agreement with the flat panel. Conclusion: The array represents a valuable tool for the characterization of treatment fields in which high spatial resolution is required, together with the dosimetric performance of air vented ionization chambers. Such a technology would be particularly valuable in association with advanced treatment modalities such as rotational radiotherapy, stereotactic treatments (even with unflattened beam qualities) and proton therapy, due to the insensitivity of the chambers on dose per pulse. In the future, a two dimensional prototype based on this technology will be developed and tested. This research project has been supported by a Marie Curie Early Initial Training Network Fellowship of the European Community's Seventh Framework Programme under contract number (PITN-GA-2011-289198-.

07 ISOTOPE AND RADIATION SOURCES↗