Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ionizing radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Radiation Effects on DC-DC Converters

In this work, several DC-DC converters were designed and built. The converters are Buck Buck-Boost, Cuk, Flyback, and full-bridge zero-voltage switched. The total ionizing dose radiation and single event effects on the converters were investigated. The experimental results for the TID effects tests show that the voltages of the Buck Buck-Boost, Cuk, and Flyback converters increase as total dose increased when using power MOSFET IRF250 as a switching transistor. The change in output voltage with total dose is highest for the Buck converter and the lowest for Flyback converter. The trend of increase in output voltages with total dose in the present work agrees with those of the literature. The trends of the experimental results also agree with those obtained from PSPICE simulation. For the full-bridge zero-voltage switch converter, it was observed that the dc-dc converter with IRF250 power MOSFET did not show a significant change of output voltage with total dose. In addition, for the dc-dc converter with FSF254R4 radiation-hardened power MOSFET, the output voltage did not change significantly with total dose. The experimental results were confirmed by PSPICE simulation that showed that FB-ZVS converter with IRF250 power MOSFET's was not affected with the increase in total ionizing dose. Single Event Effects (SEE) radiation tests were performed on FB-ZVS converters. It was observed that the FB-ZVS converter with the IRF250 power MOSFET, when the device was irradiated with Krypton ion with ion-energy of 150 MeV and LET of 41.3 MeV-square cm/mg, the output voltage increased with the increase in fluence. However, for Krypton with ion-energy of 600 MeV and LET of 33.65 MeV-square cm/mg, and two out of four transistors of the converter were permanently damaged. The dc-dc converter with FSF254R4 radiation hardened power MOSFET's did not show significant change at the output voltage with fluence while being irradiated by Krypton with ion energy of 1.20 GeV and LET of 25.97 MeV-square cm/mg. This might be due to fact that the device is radiation hardened.

Zhang, De-Xin↗

The computation of radiation from nonequilibrium hypersonic flows

The results of the solution of the equations that describe a hypersonic ionized flow about an elliptically blunted cone are presented. The flow conditions correspond to those of the proposed Aeroassist Flight Experiment (AFE) vehicle at altitudes between the perigee at 78 km and the approximate limit of the continuum regime at 90 km. For the free-stream velocities of interest, about 9 km/sec, the flowfield is out of thermo-chemical equilibrium, electronically excited, ionized and radiating. The gas consists of eight-chemical species including free electrons. The thermal state of the gas is modeled with a translational-rotational temperature, four vibrational temperatures for the diatomic species and an electron-electronic temperature. The electronic excitation of molecules is included. The nonequilibrium air radiation from each fluid element is computed and the radiative heat flux at the body surface is determined. The stagnation point radiative heating result agrees with previous calculations.

Candler, Graham↗

Ionization Chamber Measures Extreme Ultraviolet

Ionization chamber operates in nearly total photon absorption as stable, self-calibrating detector of ionizing extreme ultraviolet radiation. Working gas of instrument is neon; photoionization properties well known and readily applicable to absolute measurements. Designed for measurements of solar ultraviolet flux aboard sounding rocket, instrument used on Earth to measure ultraviolet radiation in vacuum systems. Ionization chamber collects positive neon ions and electrons produced by irradiation of neon gas by ultraviolet photons. Approximately one ion produced by each photon; consequently, photoionization current nearly proportional to photon flux.

Carlson, Robert W.↗

Total Ionizing Dose Effects on High Resolution (12-/14-bit) Analog-to-Digital Converters

This paper reports total dose radiation test results for high resolution 12-/14-bit A/D converters. Small changes in internal components can cause these devices to fail their specifications at relatively low total dose levels. Degradation of signal-to-noise ratio becomes increasingly importamt for high accuracy converters. Rebound effects in the thick-oxide MOS devices causes these responses to be different at low and high dose rates, which is a major concern for space applications.

radiation ionizing analog-to-digital converters MO↗

Radiative transfer effects behind reflected shock waves

Theoretical studies are reported which were largely centered on the nonequilibrium coupling of collisional, ionization, and radiative transfer processes behind reflected shock waves in nitrogen. Experimental studies included broad-band photomultiplier radiative intensity measurements, luminosity photographs of the reflected shock wave front, end-wall heat transfer measurements, and reflected shock velocity time-history measurements. The results of these activities are summarized, and comparisons between the theoretical and experimental results are discussed.

Nerem, R. M.↗

AGN Unification, X-Ray Absorbers and Accretion Disk MHD Winds

We present the 2D photoionization structure of the MHD winds of AGN accretion disks. We focus our attention on a specific subset of winds, those with poloidal currents that lead to density profiles n(r) \propto 1/r. We employ the code XSTAR to compute the local ionization balance, emissivities and opacity which are then used in the self-consistent transfer of radiation and ionization of a host of ionic species of a large number of elements over then entire poloidal plane. Particular attention is paid to the Absorption Measure Distribution (AMD), namely their hydrogen-equivalent column of these ions per logarithmic 7 interval, dN_H/dlog ? (? = L/n(r)r(sup 2) is the ionization parameter), which provides a measure of the winds' radial density profiles. For the given density profile, AMD is found to be independent of ?, in good agreement with analyses of Chandra and XMM data, suggesting the specific profile as a fundamental AGN property. Furthermore, the ratio of equatorial to polar column densities of these winds is \simeq 10(exp 4); as such, it is shown they serve as the "torus" necessary for AGN unification with phenomenology consistent with the observations. The same winds are also shown to reproduce the observed columns and velocities of C IV and Fe XXV of SAL QSOs once the proper ionizing spectra and inclination angles are employed.

Kazanas, Demos↗

NASA’s Galactic Cosmic Ray Simulator – How we study the effects of space radiation on Earth

Earth’s atmosphere and natural magnetic field do a good job protecting us from space radiation. Space radiation is different from radiation on Earth, which mostly comes from isotopes found in rock and soil or from medical procedures like an Xray. Ionizing space radiation comes from particles ejected from the Sun, or solar particle events, and from supernovae outside our solar system making up a background of galactic cosmic radiation. These particles, representing the elements of the periodic table, have been stripped of their electrons as they are accelerated in interstellar space to almost the speed of light. One of NASA’s biggest challenges is protecting astronauts from these high energy particles of galactic cosmic radiation which can cause cancer and other diseases. To understand the biological damage imparted to living systems and to develop protective countermeasures, NASA has built a galactic cosmic ray simulator on Earth.

Space Exploration Missions↗

Radiation measuring instrumentation

Four radiation measuring instruments were developed. These are: (1) improved detector probe, (2) neutron spectrometer--dosimeter, (3) portable ultraviolet spectro-radiometer; and (4) pocket ionization chamber radiation dosimeter. A brief description of each of these devices is presented.

Piltingsrud, H. V.↗

Energy branching in the Io plasma torus - The failure of neutral cloud theory

Model calculations are used to explore the energy source characteristics of the energy branching of the hot Io plasma torus. It is assumed that the energy is derived from the kinetic energy acquired by ions created in the rotating planetary magnetic field, and that Coulomb collisions with the electron gas control the flow of energy to the ionizing and radiative processes. The results show that neutral cloud theory is qualitatively inadequate. It is shown that neutral cloud theory can only support a dominantly singly ionized system (at the measured electron densities in the plasma torus) and that it fails to predict observed plasma properties relative to variations in number density.

Shemansky, D. E.↗

The ionization of the diffuse ionized gas

The diffuse ionized gas (DIG), responsible for producing the faint but pervasive H(sub alpha), requires 15% of the power of all Galactic O stars for its ionization. No other source of ionization seems practical. The spectrum is strong in low stages of ionization (N II, SII), weak in (O III), and very weak in (O I) lambda 6300, at least in one well-observed direction, all significantly different from denser H II regions. We give low-density, low-excitation photoionization models that explain the observed spectrum. The lambda 6300 observation eliminates the simplest models for the DIG (Mathis 1986), in which neutral H extends beyond the edge of the very dilute stellar radiation field. Our present models include two components. One, representing the edges of interstellar H I clouds, extends to the point where H becomes neutral. In the second, the fraction of H(sup o) is not allowed to exceed 0.05 to 0.1. Both have very low values of the ionization parameter, or ratio of the number densities of ionizing photons to electrons. The ionization parameter required by our models is shown to be compatible with observed values of photon and electron densities in the diffuse interstellar medium. Interstellar dust is not important in either model. Predictions of the model are that the Galaxy is leaking about 4% of the ionizing radiation of at least the local O stars into the intergalactic medium, that (O II) lambda 3727 approximately equals 1.1 H(sub alpha), and that He(sup +)/H (sup +)) approximately equals 0.6 He/H. A major difficul ty of this picture is having ionizing radiation propagate from the ionizing stars in the plane of the Galaxy to the DIG. We suggest, as do Miller & Cox (1993), that the ionizing radiation from O stars produces holes or tunnels in the distribution of neutral H as seen from their positions, while we see a sky covered with H I sheets or filaments because we are not near a source of ionizing radiation. With our models, several interfaces between ionized and neutral gas are allowed before the observational limit on lambda 6300 is exceeded. Another difficulty is the gas-phase N(S(sup +))/N(H(sup o)) ratio toward the high-latitude star HD 93521 (Spitzer & Fitzpatrick 1993). We require (S/H) to be somewhat lower than solar, either because of depletion onto grains or a Galactic abundance gradient, so that the S(sup +) can be produced in each of separate H(sup o) and H(sup +) regions.

Domgorgen, H.↗

Eta Carinae: What We have learned recently with HST/STIS, VLT/UVES and VLTI: What We Might Learn with VLT/VLTI across the 2008/9 Minimum

Eta Carinae, the LBV that we have learned to love and hate, has revealed many clues of its character over the past seven years by studies with HST and VLT. Based upon X-Ray, optical and IR observations, Eta Carinae is convincingly a massive binary system that uniquely has major nebular ejecta that are connected with historical outbursts. We have successhlly followed the stellar and nebular changes over the 5.5 year cycle, especially with STIS and RXTE, and across the spectroscopic minimum in 2003.5 with STIS, CHANDRA, RXTE, FUSE, and VLT/UVES. The HST/STIS high spatial resolution, combined with appropriate spectral resolving powers from 1150 to 10300 A, has revealed much about the Central Source and especially the spatially resolved extended stellar atmosphere and the ejecta, known as the Homunculus. Indeed the neutral, dusty outer Homunculus, ejected in the 1840s, envelops the newly discovered ionized Little Homunculus, ejected in the 1890s. In line of sight, multiple hot clumps, both ionized and neutral, are seen in absorption and provide much information on the physical conditions of these massive ejecta. Against the nebular-scattered starlight, wind and nebular absorptions provide views at different angles from line of sight. The VLT/UVES studies from 2002 through 2004 provided very important time-sampled spectra of both the star as seen directly and as seen by the SE lobe viewing the polar region of the star. The VLTI 2.2 micron measures of the central source are consistent with a prolate spheroid with its axis extending along the axis of the Homunculus. This is consistent with the noticeably larger wind mass and higher terminal velocity along the axis of the Homunculus compared to that measured in line of sight at about 45 degrees from the polar axes. We understand the system to be a massive primary with an O or WR companion in a very highly elliptical orbit. The spectroscopic minimum occurs during periastron, when the greatly extended primary atmosphere and wind bottles up the ionizing uv radiation of the companion star. This transient drop in uv photons leads to recombination of much of the wind structure and of the nearby ejecta. Doubly-ionized elements (iron, neon, argon, vanadium) recombine to singly ionized forms and extended structures on the scales of below 0.03 arcseconds to an arcsecond change, appear, or disappear. With the loss of the STIS on HST, ground-based observations, especially with high spatial-resolution facilities, including the VLT and VLTI will be key to further studies across the minimum centered on 2009.0. Now is the time to plan for these studies.

Gull, Theodore R.↗

Charging control techniques

Transparent conductive thin films of indium oxide and indium-tin oxide were evaluated for their properties to control charge buildup on satellite materials. Both oxide coatings were evaluated for their uniformity, stability, reproducibility and characteristics on various substrate materials such as FEP Teflon, Kapton, and glass. The process development toward optimization and characterization of these thin semiconductor oxide coatings and the evaluation on large sizes performed for qualification for use on thermal control satellite materials is described. The materials have been characterized in multiple energy electron plasma environment and at low temperatures. All radiation measurements of the coatings under simulated substorm conditions have exhibited the characteristics of stable charge control. Measurement of surface potential during and after irradiation by electrons up to 30 KeV and ionizing gamma radiation show an effective stable grounding surface.

Schmidt, R. E.↗