Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hyperspectral”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Verification and Validation of Hybridspectral Radiometry Obtained from an Unmanned Surface Vessel (USV) in the Open and Coastal Oceans

The hardware and software capabilities of the compact-profiling hybrid instrumentation for radiometry and ecology (C-PHIRE) instruments on an unmanned surface vessel (USV) are evaluated. Both the radiometers and USV are commercial-off-the-shelf (COTS) products, with the latter being only minimally modified to deploy the C-PHIRE instruments. The hybridspectral C-PHIRE instruments consist of an array of 18 multispectral microradiometers with 10 nm wavebands spanning 320–875 nm plus a hyperspectral compact grating spectrometer (CGS) with 2048 pixels spanning 190–1000 nm. The C-PHIRE data were acquired and processed using two architecturally linked software packages, thereby allowing lessons learned in one to be applied to the other. Using standard data products and unbiased statistics, the C-PHIRE data were validated with those from the well-established compact-optical profiling system (C-OPS) and verified with the marine optical buoy (MOBY). Agreement between algorithm variables used to estimate colored dissolved organic matter (CDOM) absorption and chlorophyll a concentration were also validated. Developing and operating novel technologies, such as the C-PHIRE series of instruments, deployed on a USV increase the frequency and coverage of optical observations, which are required to fully support the present and next-generation validation exercises in radiometric remote sensing of aquatic ecosystems.

Hybridspectral↗

PCRTM-RA Enhancements for Improving CO Retrievals Using NAST-I Measurements From the FIREX-AQ Field Campaign

The Principal Component-based Radiative Transfer Model Retrieval Algorithm (PCRTM-RA) for carbon monoxide (CO) retrieval has been improved for better use of National Airborne Sounder Testbed-Interferometer (NAST-I) measurements obtained during the Fire Influence on Regional to Global Environments and Air Quality (FIREX-AQ) field campaign. One of the explicit purposes of the campaign was to characterize wildfire-induced atmospheric changes. Coincidental measurements from various airborne instruments including NAST-I infrared hyperspectral measurements from the NASA ER-2 aircraft provided us an opportunity to test and improve the PCRTM-RA CO retrieval. By relaxing the vertical correlation of CO profiles in the a-priori covariance constraint, a significant improvement in the vertical structure of the CO retrieval has been confirmed. The methodology is validated using a synthetic testing dataset that covers observations associated with various CO vertical profiles including that of an extremely polluted atmosphere. The methodology is also applied to real NAST-I measurements, and the results have successfully demonstrated the capability of using PCRTM-RA retrieval results for CO plume evolution and transport monitoring.

Carbon monoxide (CO)↗

Optical and Detector Design of the Ocean Color Instrument for the NASA Pace Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem mission is a hyperspectral imager with high SNR, precision and dynamic range, and with a very low striping artifact level in the 342-887 nm wavelength range with a spectral resolution of 5 nm in 2.5 nm steps, providing a significant technological advancement over previous ocean imagers. To achieve this, OCI is designed with specialized optical imaging and opto-electronic detection systems that push the boundaries of several state-of-the-art technologies. This paper provides an overview of these systems together with their achieved performances and discussions of their key design challenges.

Remote sensing↗

Optical and Detector Design of the Ocean Color Instrument for the NASA Pace Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem mission is a hyperspectral imager with high SNR, precision and dynamic range, and with a very low striping artifact level in the 342-887 nm wavelength range with a spectral resolution of 5 nm in 2.5 nm steps, providing a significant technological advancement over previous ocean imagers. To achieve this, OCI is designed with specialized optical imaging and opto-electronic detection systems that push the boundaries of several state-of-the-art technologies. This paper provides an overview of these systems together with their achieved performances and discussions of their key design challenges.

Remote sensing↗

CLARREO Pathfinder Mission Overview and its Intercalibration Capabilities

NASA's Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) mission will deploy an Earth-observing reflected solar (RS) spectrometer, designed to measure Earth-reflected solar radiation from the International Space Station with a remarkable SI-traceable radiometric uncertainty of 0.3% (k=1). This spectrometer, known as the Hyperspectral Imager for Climate Science (HySICS), will provide measurements within a spectral range of 350-2300 nm with 3-nm spectral intervals. Covering a nadir swath of 70 km, HySICS captures 480 discrete measurement pixels that provide spectrally-resolved Earth-reflected radiances. The CPF mission encompasses two principal objectives. The first objective is to demonstrate on-orbit calibration methodologies that achieve and uphold an unprecedented level of accuracy while maintaining traceability to SI standards. The second objective is to showcase an innovative on-orbit intercalibration approach, which involves the intercalibration of two other RS sensors—namely, the shortwave (SW) channel of the Clouds and the Earth’s Radiant Energy System (CERES) and the Reflective Solar (RS) bands of the Visible Infrared Imager Radiometer Suite (VIIRS)—against CPF benchmark measurements. The targeted intercalibration methodology uncertainty for these target instruments is 0.3% (k=1). Empowered by the CPF payload's two-axis pointing capability, moderate spatial sampling of 0.5 km, and wide spectral coverage, the CPF instrument will capture near-simultaneous temporal, spatial, angular, and spectrally matched observations with intercalibration targets. The CPF intercalibration science development team has devised novel methods to address spatial, spectral, polarization, and angular differences between CPF and the target instruments' intercalibration footprints to achieve the stringent 0.3% intercalibration methodology uncertainty. Comprehensive details of these methods and their validation will be elaborated upon during the conference presentation.

Hyperspectral↗

Space Qualification Studies of AOTF Devices Under the MISSE-11 Mission

The acousto-optic tunable filter (AOTF) devices are used in a variety of applications including hyperspectral and spectrapolarimetric based imaging. The AOTF devices provide several advantages including speed and random access to desired spectral bands and enable all-solid-state operation that are attractive for space applications. In this paper, the performance of Tellurium Dioxide (TeO 2 ) and Mercurous Bromide (Hg 2 Br 2 ) AOTF devices in space environment carried out under the NASA’s Materials International Space Station Experiments 11 (MISSE-11) mission is discussed. The purpose of the MISSE-11 mission was to study materials and devices subjected to space conditions for long term while attached to the International Space station (ISS). The TeO 2 AOTF was developed for short wavelength IR (SWIR) operation while the Hg 2 Br 2 AOTF device was developed for long wavelength IR (LWIR) operation. These devices were attached to the ISS platform for more than a year. Pre-flight and post-flight performance characterization were performed on these devices. In the case of TeO 2 AOTF, the preflight efficiency was around 87% with a center frequency at 68MHz while the post-flight efficiency was around 83%. However, the optical transmission of Hg 2 Br 2 AOTF had deteriorated considerably. The details of performance testing and analysis of both AOTF devices are discussed.

Space Qualification↗

NASA's CLARREO Pathfinder Mission: The Reflected Solar’s First SITSat

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder mission will take reflected solar (RS) highly accurate measurements needed to monitor Earth’s climate and will be the first RS SI-traceable Satellite Sensor (SITSat). The mission includes a RS spectrometer that will be installed on the International Space Station (ISS) and take measurements for at least one year. CLARREO Pathfinder (CPF) will use on-orbit calibration to achieve an unprecedented high accuracy with SI-traceability and the inter-calibration of other on-orbit instruments. The spectrometer is based on the HyperSpectral Imager for Climate Science (HySICS) instrument developed by the University of Colorado/Laboratory for Atmospheric and Space Physics of Boulder, CO, USA. HySICS is being designed to have a radiometric uncertainty of 0.3% (1-sigma), a five to ten times improvement over existing spaceflight RS instruments. High accuracy SI-traceable measurements such as these are critical to develop long-term climate-quality data sets. Additionally, by measuring spectral reflectance with high accuracy the CPF instrument will serve as an on-orbit intercalibration radiometric reference for operational Earth-viewing sensors, such as the Clouds and Earth’s Radiant Energy System (CERES) broadband shortwave instrument and the Visible/Infrared Imaging Radiometer Suite (VIIRS). Two-axis pointing, a spectral range from 350 nm to 2300 nm, and a spectral resolution ≤6 nm enable CPF to provide nearly coincident temporal, spatial, angular, and spectral matching of intercalibration targets, with sampling sufficient to reduce random errors. The intercalibration method will refine knowledge of target sensors’ effective offsets, gain, non-linearity, spectral response, and polarization sensitivity (as is relevant). Calibrated reflectance and reflected radiance spectra will be distributed to the scientific community through a NASA Distributed Active Archive Center (DAAC). We will present an overview of the CLARREO Pathfinder mission, its anticipated impact on monitoring climate variability, and the novel CPF direct intercalibration approach.

climate↗

Spectrally Dependent Radiometric Measurement Errors Due to Ccd Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a 322 887 nm hyperspectral imager with 1 km x 1 km nadir spatial resolution and 5 nm spectral resolution utilizing charge-coupled devices (CCDs) operating in Time Delay Integration (TDI) mode where each TDI column represents a different wavelength in 0.625 nm increments. After TDI, the charge is moved into serial output pixels and read out. The spatial resolution requires an 8.5 MHz readout rate. This only allows 59 ns for the CCD reset and video to be asserted and settled before sampling. The response exhibits serial pixel-to-pixel readout interference due to the lack of full settling. Each serial pixel value has a dependence on the value of the preceding pixel value. This leads to a spectrally dependent radiometric measurement error of up to 0.3 %. We explain the operation of the detection system, the behavior of the interference, and show the resulting measurement error based on data from both ground testing and on-orbit characterization.

Remote Sensing↗

Integrating Manned Aircraft and UAVs for the Prediction, Tracking, and Eradication of Desert Locust Swarms

Desert locusts (Schistocerca gregaria) present an acute threat to the agriculture of certain regions, capable of annihilating vast expanses of farmland and destabilizing food security. In this paper, an aviation-based framework concept is introduced that integrates both manned aircraft and Unmanned Aerial Vehicles (UAVs) to preemptively forecast, localize, and eliminate locust swarms efficiently. The framework begins by leveraging predictive modeling methods to refine search areas and pinpoint high-value Points of Interest (POIs) where locust swarms are most likely to materialize. From there, the proposed two-step model uses optical, infrared, and hyperspectral sensors onboard manned aircraft to conduct long-range surveying of probable swarm locations. Upon detection of a swarm, UAVs equipped with sophisticated sensors, including pheromone detectors, thermal and optical imaging systems, are deployed directly from the aircraft to carry out targeted biopesticide applications. This approach, which capitalizes on the combined strengths of both vehicles, provides the rapid response and large-scale intervention necessary to control locust outbreaks. By targeting locust swarms during their most destructive phase, this paper aims to disrupt the locust life cycle and mitigate their severe agricultural impact, offering a scalable and sustainable solution for food security in afflicted regions.

locust monitoring systems↗

Spectrally Dependent Radiometric Measurement Errors Due to CCD Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a 322 887 nm hyperspectral imager with 1 km x 1 km nadir spatial resolution and 5 nm spectral resolution utilizing charge-coupled devices (CCDs) operating in Time Delay Integration (TDI) mode where each TDI column represents a different wavelength in 0.625 nm increments. After TDI, the charge is moved into serial output pixels and read out. The spatial resolution requires an 8.5 MHz readout rate. This only allows 59 ns for the CCD reset and video to be asserted and settled before sampling. The response exhibits serial pixel-to-pixel readout interference due to the lack of full settling. Each serial pixel value has a dependence on the value of the preceding pixel value. This leads to a spectrally dependent radiometric measurement error of up to 0.3 %. We explain the operation of the detection system, the behavior of the interference, and show the resulting measurement error based on data from both ground testing and on-orbit characterization.

Remote Sensing↗

Total variation vs L1 regularization: a comparison of compressive sensing optimization methods for chemical detection

One of the fundamental assumptions of compressive sensing (CS) is that a signal can be reconstructed from a small number of samples by solving an optimization problem with the appropriate regularization term. Two standard regularization terms are the L1 norm and the total variation (TV) norm. We present a comparison of CS reconstruction results based on these two approaches in the context of chemical detection, and we demonstrate that optimization based on the L1 norm outperforms optimization based on the TV norm. Our comparison is driven by CS sampling, reconstruction, and chemical detection in two real-world datasets: the Physical Sciences Inc. Fabry-Perot interferometer sensor multispectral dataset and the Johns Hopkins Applied Physics Lab FTIR-based longwave infrared sensor hyperspectral dataset. Both datasets contain the release of a chemical simulant such as glacial acetic acid, triethyl phosphate, and sulfur hexafluoride. For chemical detection we use the adaptive coherence estimator (ACE) and bulk coherence, and we propose algorithmic ACE thresholds to define the presence or absence of a chemical of interest in both un-compressed data cubes and reconstructed data cubes. The un-compressed data cubes provide an approximate ground truth. We demonstrate that optimization based on either the L1 norm or TV norm results in successful chemical detection at a compression rate of 90%, but we show that L1 optimization is preferable. We present quantitative comparisons of chemical detection on reconstructions from the two methods, with an emphasis on the number of pixels with an ACE value above the threshold.

Hyperspectral imagery, L1-norm, total variation, A↗

Flexible Vanadium Dioxide Photodetectors for Visible to Longwave Infrared Detection at Room Temperature

Abstract Flexible optoelectronics is a rapidly growing field, with a wide range of potential applications. From wearable sensors to bendable solar cells, curved displays, and curved focal plane arrays, the possibilities are endless. The criticality of flexible photodetectors for many of these applications is acknowledged, however, devices that are demonstrated thus far are limited in their spectral range. In this study, flexible photodetectors are demonstrated using a VO x nanoparticle ink, with an extremely broad operating wavelength range of 0.4 to 20 µm. This ink is synthesized using a simple and scalable wet‐chemical process. These photodetectors operate at room temperature and exhibit minimal variance in performance even when bent at angles of up to 100 ° at a bend radius of 6.4 mm. In addition, rigorous strain testing of 100 bend and release cycles revealed a photoresponse with a standard deviation of only 0.55%. This combination of mechanical flexibility, wide spectral response, and ease of fabrication makes these devices highly desirable for a wide range of applications, including low‐cost wearable sensors and hyperspectral imaging systems.

36 MATERIALS SCIENCE↗

Decoding the Broadband Emission of 2D Pb-Sn Halide Perovskites through High-Throughput Exploration

Unlike single-component 2D metal halide perovskites (MHPs) exhibiting sharp excitonic photoluminescence (PL), a broadband PL emerges in mixed Pb-Sn 2D lattices. Two physical models –self-trapped exciton and defect-induced Stokes-shift – are proposed to explain this unconventional phenomenon. However, the explanations provide limited rationalizations without consideration of the formidable compositional space, and thus, the fundamental origin of broadband PL remains elusive. Herein, the high-throughput automated experimental workflow is established to systematically explore the broadband PL in mixed Pb-Sn 2D MHPs, employing PEA (Phenethylammonium) as a model cation known to work as a rigid organic spacer. Spectrally, the broadband PL becomes further broadened with rapid PEA 2 PbI 4 phase segregation with increasing Pb concentrations during early-stage crystallization. Counterintuitively, MHPs with high Pb concentrations exhibit prolonged PL lifetimes. Hyperspectral microscopy identifies substantial PEA 2 PbI 4 phase segregation in those films, hypothesizing that the establishment of charge transfer excitons by the phase segregation upon crystallization at high-Pb compositions results in distinctive PL properties. In conclusion, these results indicate that two independent mechanisms—defect-induced Stoke-shifts and the establishment of charge transfer excitons by phase segregation—coexist which significantly correlates with the Pb:Sn ratio, thereby simultaneously contributing to the broadband PL emission in 2D mixed Pb-Sn HPs.

2D Pb-Sn halide perovskites↗

Machine Detection of Enhanced Electromechanical Energy Conversion in PbZr 0.2 Ti 0.8 O 3 Thin Films

Many energy conversion, sensing, and microelectronic applications based on ferroic materials are determined by the domain structure evolution under applied stimuli. New hyperspectral, multidimensional spectroscopic techniques now probe dynamic responses at relevant length and time scales to provide an understanding of how these nanoscale domain structures impact macroscopic properties. Such approaches, however, remain limited in use because of the difficulties that exist in extracting and visualizing scientific insights from these complex datasets. Using multidimensional band-excitation scanning probe spectroscopy and adapting tools from both computer vision and machine learning, an automated workflow is developed to featurize, detect, and classify signatures of ferroelectric/ferroelastic switching processes in complex ferroelectric domain structures. This approach enables the identification and nanoscale visualization of varied modes of response and a pathway to statistically meaningful quantification of the differences between those modes. Lastly, among other things, the importance of domain geometry is spatially visualized for enhancing nanoscale electromechanical energy conversion.

36 MATERIALS SCIENCE↗

Sub‐Diffraction Correlation of Quantum Emitters and Local Strain Fields in Strain‐Engineered WSe 2 Monolayers

Strain-engineering in atomically thin metal dichalcogenides is a useful method for realizing single-photon emitters (SPEs) for quantum technologies. Correlating SPE position with local strain topography is challenging due to localization inaccuracies from the diffraction limit. Currently, SPEs are assumed to be positioned at the highest strained location and are typically identified by randomly screening narrow-linewidth emitters, of which only a few are spectrally pure. In this work, hyperspectral quantum emitter localization microscopy is used to locate 33 SPEs in nanoparticle-strained WSe 2 monolayers with sub-diffraction-limit resolution (≈30 nm) and correlate their positions with the underlying strain field via image registration. In this system, spectrally pure emitters are not concentrated at the highest strain location due to spectral contamination; instead, isolable SPEs are distributed away from points of peak strain with an average displacement of 240 nm. These observations point toward a need for a change in the design rules for strain-engineered SPEs and constitute a key step toward realizing next-generation quantum optical architectures.

2D material↗

Longitudinal Single‐Cell Imaging of Engineered Strains with Stimulated Raman Scattering to Characterize Heterogeneity in Fatty Acid Production

Abstract Understanding metabolic heterogeneity is critical for optimizing microbial production of valuable chemicals, but requires tools that can quantify metabolites at the single‐cell level over time. Here, longitudinal hyperspectral stimulated Raman scattering (SRS) chemical imaging is developed to directly visualize free fatty acids in engineered Escherichia coli over many cell cycles. Compositional analysis is also developed to estimate the chain length and unsaturation of the fatty acids in living cells. This method reveals substantial heterogeneity in fatty acid production among and within colonies that emerges over the course of many generations. Interestingly, the strains display distinct types of production heterogeneity in an enzyme‐dependent manner. By pairing time‐lapse and SRS imaging, the relationship between growth and production at the single‐cell level are examined. The results demonstrate that cell‐to‐cell production heterogeneity is pervasive and provides a means to link single‐cell and population‐level production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Engineering Perovskite Precursor Inks for Scalable Production of High‐Efficiency Perovskite Photovoltaic Modules

Abstract Blade coating of perovskite solar cells (PSCs) and modules has progressed considerably toward the industrial production of perovskite photovoltaics. Developing stable perovskite precursors is critical for achieving uniform coating over large areas. Here, the engineering of a perovskite precursor solution consisting of 2‐methoxyethanol (2‐Me) and 1,3‐dimethyl‐imidazolidinone (DMI) with superior intermediate phase stability that enables scalable production of efficient perovskite solar modules is reported. With this perovskite precursor solution, uniform and pinhole‐less perovskite film is deposited over a large area of > 100 cm 2 and higher‐efficiency PSCs and modules are obtained. The best‐performing unit cell and module with n‐i‐p configuration reach power conversion efficiencies of 23.4% and 20.1%, respectively. Additionally, a series of non‐destructive metrology methods, such as spectroscopic ellipsometry, hyperspectral photoluminescence, electroluminescence, and laser beam‐induced current mapping, are employed to assess and guide the development the blade‐coated perovskite modules. This results show that rational engineering of precursor inks for blade coating is promising for the scalable production of efficient perovskite solar modules.

36 MATERIALS SCIENCE↗