Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Gas Engine-Driven Heat Pump with Desiccant Dehumidification

About 40% of total U.S. energy consumption was consumed in residential and commercial buildings. Improved air-conditioning technology has by far the greatest potential impact on the electric industry compared to any other technology that uses electricity. This paper describes the development of an innovative natural gas, propane, LNG or bio-gas IC engine-driven heat pump (GHP) with desiccant dehumidification (GHP/DD). This integrated system has higher overall efficiencies than conventional equipment for space cooling, addresses both new and existing commercial buildings, and more effectively controls humidity in humid areas. Waste heat is recovered from the GHP to provide energy for regenerating the desiccant wheel and to augment heating capacity and efficiency. By combining the two technologies, an overall source COP of greater that 1.5 (hot, humid case) can be achieved by utilizing waste heat from the engine to reduce the overall energy required to regenerate the desiccant. Moreover, system modeling results show that the sensible heat ratio (SHR- sensible heat ratio) can be lowered to less 60% in a dedicated outdoor air system application with hot, humid cases.

dessicant coupled air conditioning system↗

Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) Winter Intensive Operational Period: Aerodynamic Particle Sizer Field Campaign Report

An aerodynamic particle sizer spectrometer (APS, model 3321 by TSI Inc., Shoreview, Minnesota) was deployed at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Eastern North Atlantic (ENA) observatory during the second (winter) intensive operational period (IOP) of the Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) field campaign. Data were collected from January 9 through February 26, 2018, covering the second deployment of the ARM Aerial Facility (AAF) aircraft within ACE-ENA. The standard ENA instrument suite does not provide measurements of aerosol particle size distribution for diameters greater than one micron. Properties of coarse-mode (super-micron) aerosols are rarely measured, although super-micron particles can play an important role in the aerosol life cycle, affecting aerosol optical properties and cloud nuclei activity (e.g., Clarke et al. 2003). The APS was deployed to fill this gap in particle size measurements: it is capable of measuring size-resolved concentration of the aerosols in the 0.5-20 μm range (aerodynamic diameter). The APS was installed in the aerosol trailer to sample through the main stack. Special attention was given to selection of the instrument location (just below the main stack) to minimize particle losses in the connecting lines. Most atmospheric aerosols are hygroscopic, so the measurement of the aerosol size distributions should either be performed in a controlled humidity environment or accompanied by concurrent measurement of the temperature and humidity of the sample air. The latter strategy was used during this deployment: a high-precision humidity/temperature transmitter (model EE08 by E+E Elektonik GMBH, Engerwitzdorf, Germany) was mounted in the APS sampling line immediately upstream of the APS inlet. A dedicated laptop computer was used for data collection and communications. The APS was controlled with vendor-supplied software (Aerosol Instrument Manager, ver. 10.1, TSI); aerosol size distribution data were collected over a period of 55 seconds and converted to one-minute averages. Temperature and humidity analog signals were acquired via analog-to-digital converter (ADC) module (model WTAIN-M by Weeder Technologies, Fort Walton Beach, Florida) using vendor-supplied software (ModCom) with 1- sec resolution. In post-processing, the APS data were exported from TSI proprietary format into “comma-separated value” American Standard Code for Information Interchange (ASCII) files and matched with appropriately averaged temperature and humidity data. Two significant periods of missing data were caused by local power outages. Vendor-supplied software was not designed for unattended operation: it needs to be manually restarted including sensor configuration setup.

ACE-ENA, Azores, ultra-high-sensitivity aerosol sp↗

Evaporation-driven engines

Evaporation-driven engines are disclosed herein. An example engine can include a water source having a high humidity zone proximate the surface of the water source, a supporting structure, and a hygroscopic material disposed on the supporting structure and configured to generate mechanical force in response to a changing relative humidity. The hygroscopic material can be repeatedly exposed to the high humidity zone and removed from the high humidity zone thereby causing the hygroscopic material to generate mechanical force.

Chen, Xi↗

Adaptive Water-Resistive Barrier for Building Envelopes

Excessive moisture transport into building enclosures can lead to elevated moisture levels in wall cavities and associated damage. Such conditions can also produce increased energy consumption. Currently, architects and builders are limited to using static membranes as water-resistive barriers that exhibit a single vapor permeance irrespective of environmental conditions. Membranes with a high permeance may allow moisture ingression under hot and humid ambient conditions, while membranes with a low permeance may not allow wall cavities to dry out when moisture accumulates within them.An electrostatically actuated, dual permeance membrane previously demonstrated for protective apparel is under development for use as a water-resistive barrier for building envelopes. When outdoor temperature and relative humidity are high as detected by sensors, the membrane exhibits low permeance (~0.5 perms) to inhibit water vapor ingression into the building enclosure; but when humidity in the wall cavity is high, the membrane exhibits high permeance (~50 perms) to facilitate water vapor egression to the outside. The membrane changes state by electrostatic actuation using a very low current electrical power supply.In order to quantify the benefits of a dual permeance water-resistive barrier, WUFI® hygrothermal modeling simulations were completed comparing the adaptive membrane to conventional fixed permeance membranes relative to inhibiting mold growth for various US climates and several wall constructions. The WUFI® code was modified to accommodate switching the permeance of the adaptive membrane between low and high permeance states for several humidity setpoint control strategies. The effect of liquid water leakage into the wall cavity was also considered.This report summarizes the initial steps in development of dual permeance, electrostatically actuated water-resistive barriers focusing on the results of hygrothermal model simulations of these adaptive structures and testing of subscale adaptive structures to demonstrate the capability of the technology to achieve the preferred permeance levels suggested by the modeling.

Trentacosta, Joseph↗

Experimental Investigation of the Effect of Atomizing Electrospray Nozzles on the Cooling and Reduced Humidification of Air

Separating sensible and latent cooling have shown the potential to reduce energy consumption in A/C systems for building HVAC applications. Several technologies exist based on vapor-compression refrigeration, enthalpy wheels, chemical adsorption and absorption materials, and mechanical cooling. However, their thermodynamics limits and high energy consumption hinder their deployment in hot and humid climatic regions. This paper focuses on separating sensible and latent cooling by using a new thermodynamics process and in-kind (i.e., non-vapor compression-based) technology. Highly electrically charged water droplets were sprayed in the airflow. These droplets attracted water vapor molecules to their surfaces and promoted condensation. The phenomenon was the result of simultaneous dielectrophoresis and electro-diffusion interactions. Studies in the literature have shown that using multiple capillary electrodes reduced air moisture by up to 5% when using nanometer-size droplets in the spray. Unfortunately, these studies were limited to low airflow rates, and the objective of this paper was to investigate how to scale up this in-kind approach to airflows typical of buildings. In the present paper, droplets of micrometer size were utilized to control the humidity for a 5-cfm flow rate. While this airflow was still low for building applications, it was 100 times fold the airflows in the literature studies. The air was tested at 20°C and at 50 and 80% relative humidity. A two-fluid atomizing nozzle produced the droplets in the spray, and high DC electric potential, up to 25 kV, was used to charge the fine droplets electrically. The air atomizing nozzle with high voltage potential resembled an evaporative cooler process. However, a measurable reduction of the absolute humidity of up to 2% was observed compared to the case of the nozzle with no high voltage potential. The entire device had one small nozzle selected from off-the-shelf components and had less than a 9 cm2 footprint area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The effect of barrier films and exposure on the aging of vacuum insulation panels with fumed silica cores

Vacuum insulation panels have very low thermal conductivities compared to conventional insulation materials. The reduction of the core pressure significantly lowers gas phase conduction and overall thermal conductivity. As a consequence, increases in gas pressure can significantly increase thermal conductivity of the VIP. In addition, the thermal conductivity of the core is sensitive to moisture content. For vacuum insulation panels with fumed silica cores, work shows that the measured thermal conductivity increases by 0.5 x 10-3 W/mK per mass percent increase in water content [1]. This is significant since the thermal conductivity of vacuum insulation panels with fumed silica cores is in the range of 0.004 W/mK. This work investigates the long-term behavior of vacuum insulation panels comprised of fumed silica cores with polymer (ethylene vinyl alcohol) and metalized (aluminized) barrier films exposed to different exposure conditions: ambient conditions; exterior conditions in a mixed humid climate; and 24oC and 80 percent relative humidity. Results show that the increase in thermal conductivity is more pronounced for vacuum insulation panels made using polymer barrier films compared to the same panel protected by a metalized film. The increase is more pronounced when exposed to high relative humidity, 80 percent. After almost two years exposure, the decrease in thermal conductivity for vacuum insulation panels protected by a metalized barrier films are between 4 and 11 percent depending on exposure condition. The smallest decrease is for ambient conditions where the largest decrease is for exposure to 80 percent relative humidity. Similar behavior was observed for panels protected using polymer films, except the decrease in thermal conductivity was significantly higher, between approximately 20 and 60 percent, in the same order as for panels protected by metalized films. Measurements are ongoing with an attempt to develop a better relationship between these types of tests and vacuum insulation panel service life.

Aldykiewicz Jr, Antonio↗

Effect of Drying on Corrosion Mitigation of Hanford Transfer Lines

Radioactive waste is stored in underground, carbon-steel double-shell tanks at the Department of Energy Hanford site. The waste is transferred between the tanks and other assets using the transfer lines spanning throughout the various tank farms at Hanford. The transfer lines consist of a pipe-in-pipe design, small diameter pipes, and are not piggable. Recent inspection data of the transfer lines have shown areas with corrosion on both interior of the encasements and exterior of the primary pipes, with nearly 50 percent wall loss on the primary pipes and nearly 25% wall loss on the encasement pipes due to pitting corrosion. The visual inspections of the transfer lines have shown presence of corrosion products near the pipeline risers and beyond. It has been hypothesized that the corrosion is predominantly due to the high humidity conditions and in some cases is driven by the presence of residual hydrotest water in the encasement and the associated contact with the safety significant primary pipe. Therefore, drying of the transfer lines could lead to corrosion mitigation. Experimental studies are being conducted to understand the effect of environmental conditions, especially, relative humidity and temperature, on transfer line grade carbon steel corrosion and on mitigating corrosion. The experimental conditions are selected based on the seasonal temperature changes, and relative humidity conditions ranging from 30 to 100 percent. The experimental data will be used as guidance for maintaining a dry environment that will help mitigate the transfer-line corrosion caused by the high humidity conditions.

Shukla, Pavan K.↗

Thermodynamic Model and Initial Experimental Investigation of Air Dehumidification through Electrically Charged Vapor Capturing Electrostatic Droplets

The removal of water vapor from the air to reduce relative humidity is a well known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation with the goal to reduce the energy consumption associated with dehumidification. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. In this thesis, a broad theoretical investigation to study the electrostatically enhanced condensation processes was carried out. These processes consist of the use of highly charged particles, preferably highly charged water droplets to attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. The electrical charge promotes the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation on curved surfaces and, consequently, the equilibrium between evaporation and condensation is shifted towards condensation. This investigation resulted in the development of a thermodynamics model, which was able to predict an effective size range of the charged droplets for optimal dehumidification, under ideal conditions. The range resulted in about 2 to 4 m in diameter, while the electrical charge was kept to the maximum limit predicted by the Rayleigh model. A sensitivity analysis on the variation of the size and the charge of the charged droplets was also performed. In terms of dehumidification rates, when six electrospray heads, i.e. the maximum number of heads tested in the experimental campaign, were considered, the model predicted very limited rates, way lower than the target of this research, i.e. a dehumidification rate in terms of relative humidity of 5 % with an air flow rate of 5 cfm. While ways to increase this rate existed, their implementation proved difficult for this initial investigation. According to the requirements predicted by the model, the use of electrosprays appeared the most suitable solution for the production of small but highly charged droplets. The electrospray features and operational modes were studied in detail and an electrospray assembly was designed to be tested in this initial experimental investigation. For this initial investigation, an experimental system was designed and built to validate the thermodynamics model and with the goal to achieve a dehumidification rate of 5 % in terms of relative humidity with an air flow rate of 5 cfm. The experimental system consisted of a wind tunnel test apparatus, dew point sensors, thermocouples for temperature measurements, pressure sensors and other devices. The experimental system was equipped with a computerized data acquisition and storage system. The system was suitable to evaluate the air water content differential before and after the test section where the electrospray heads were installed. The air water content differential was evaluated in terms of the ∆ω/ω_1 ratio, to eliminate the dependence on the dry bulb temperature along the test apparatus. This work presented initial experimental data for electrostatically enhanced dehumidification processes. Working parameters, such as air and water flow rates, high voltage potentials and polarity, deionized water types with different electrical conductivity, were varied to find the best combination for an improved dehumidification. With the set up used and the conditions considered, it was never possible to achieve a 5 % dehumidification rate with 5 cfm. In general, the dehumidification rate was always limited and lower than 1 % for all the air flow rates considered and mainly within the uncertainty of the dew point sensors. These results confirmed the already limited predictions of the thermodynamics model, for ideal conditions and the interesting and promising results obtained in some experimental investigations available in the open literature were not achievable in this thesis. The more probable reasons were the higher air flow rates considered and the complete absence of the use of cooling power, which was mainly implemented to facilitate the vapor condensation.

Morcelli, Stefano↗

Estimators and Fusers for Fiber Delay Estimation Using Environmental Measurements

The properties of deployed network fiber are affected by environmental factors due to their exposure to the elements. Particularly for quantum networks, the resultant delay variations may have significant impacts due to the extreme sensitivity of synchronization, coincidence counting, and other critical operations. In this paper, the delays of 15 km aerial-inground fiber connections are measured, and effects due to temperature, humidity and wind speed are analyzed over multiple periods spanning four seasons of a year. Machine learning methods are first utilized to reveal surprisingly pronounced effects of humidity on the delay, in addition to the expected temperature and its seasonal variations. Estimator and fusion methods are developed to estimate the delay using temperature, humidity and wind speed measurements, by utilizing smooth Gaussian Process Regression (GPR) and nonsmooth Ensemble of Trees (EOT) methods. Measurements from winter and summer periods are temporally fused using twelve different methods, and eight methods provide estimates for the delay throughout the year with median test errors under 1.28%. The results reveal distinct temperature-humidity trends across the seasons, and the ability of estimator and temporal fusion methods to exploit them for estimating the delay. These results constitute a case study of machine learning analytical results, wherein generalization equations explain the performance of various estimator and fuser methods.

Rao, Nageswara [ORNL] (ORCID:0000000234085941)↗

Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting

BSC TO5 Task 2.5 Field Testing of an Un-vented Roof with Fibrous Insulation and Tiles - Winter Park, FL 32789 Field test data available for wood moisture contents, temperature, and relative humidity. Un-vented roofs (aka cathedral-ized attics) are an established presence in Florida residential building markets. These roofs are built with a layer of spray polyurethane foam (SPF) on the underside of the roof deck. Such a roof configuration positions the heating, ventilating, and air-conditioning equipment and ductwork within the conditioned space and improves airtight-ness in practice (by shifting the air barrier from the ceiling to the roofline). However, SPF is more expensive than fibrous insulation. Some builders have also become wary of using SPF because of liability concerns about indoor air quality and off-gassing. Unfortunately, un-vented roofs that use only air-permeable fibrous insulation (cellulose or fiberglass) have been demonstrated to be at risk of moisture issues in climate zone 2A because condensation and moisture accumulation occur at the ridge. This report describes research about a test implementation of an un-vented tile roof assembly in a hot-humid climate (Orlando, Florida; climate zone 2A); the roof was insulated with air-permeable insulation (netted and blown fiberglass). Given the localized moisture accumulation and failures seen in previous work, the U.S. Department of Energy's Building America research team Building Science Corporation theorized that installation of diffusion vents might allow for the wintertime release of moisture to safe levels. Diffusion vents are open slots at the roof's highest points (the ridge and hips) that are covered with a water-resistant but vapor-open (500+ perm) air barrier membrane. The test home is a two-story slab-on-grade structure (3,600 ft2 ); the roof was insulated with a prototype insulation system (called boxed netting), which allows full depth insulation (i.e., it is not limited by the depth of the truss top chord). As a control comparison, one part of the roof was constructed as a typical un-vented roof (with a self-adhered membrane at the ridge). Ideally, failure would occur in the control roof and the experimental (diffusion vent) roofs would show sufficient drying to avoid failure. No intentional space conditioning was provided in the un-vented attic so worst-case humidity buildup conditions could be observed.

air leakage↗

Understanding Mesoscale Aggregation of Shallow Cumulus Convection Using Large-Eddy Simulation

Marine shallow cumulus convection, often mixed with thin stratocumulus, is commonly aggregated into mesoscale patches. The mechanism and conditions supporting this aggregation are elucidated using 36 h large-eddy simulations (LES) on a 128 3 128 km doubly periodic domain, using climatological summertime forcings for a location southeast of Hawaii. Within 12 h, mesoscale patches of higher humidity, more vigorous cumulus convection, and thin detrained cloud at the trade inversion base develop spontaneously. Mesoscale 16 3 16 km subdomains are composited into quartiles of column total water path and their heat and moisture budgets analyzed. The weak temperature gradient approximation is used to explain how apparent heating perturbations drive simulated mesoscale circulations, which in turn induce relative moistening of the moistest subdomains, a form of gross moist instability. Self-aggregation is affected by precipitation and mesoscale feedbacks of radiative and surface fluxes but still occurs without them. In that minimal-physics setting, the humidity budget analysis suggests self-aggregation is more likely if horizontal-mean humidity is a concave function of the horizontal-mean virtual potential temperature, a condition favored by radiative cooling and cold advection within the boundary layer.

54 ENVIRONMENTAL SCIENCES↗

Characteristics of Hydrogen Sensors Based on Thin Tin Dioxide Films Modified with Platinum, Palladium, Silver, and Yttrium

The dependence of the characteristics of hydrogen sensors based on thin Pt/Pd/SnO{sub 2}:Sb, Ag, Y and Ag/SnO{sub 2}:Sb, Ag, Y films obtained by the method of magnetron sputtering at a direct current on the humidity level of the gas mixture during operation in thermal cyclic mode is investigated. The analysis of the experimental data was carried out using the expressions obtained on the basis of the dissociative adsorption model of hydrogen and water molecules on the SnO{sub 2} surface, taking into account the presence of three types of adsorbed particles: O{sup –}, OH, OН{sup –}. The use of complex modifiers Pt/Pd, Ag on the surface and Ag + Y in the bulk of tin dioxide films allows to reduce the influence of humidity on the characteristics of sensors. The role of these modifying additives in the process of dissociative adsorption of hydrogen molecules on the surface of SnO{sub 2} films in humid environment is established.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Parabolic oxidation kinetics of a plutonium alloy at room temperature

Auger electron spectroscopy (AES) was used to characterize the oxide scale formed on an ~0.5 wt. % Ga plutonium metal alloy. Analysis of changes to the characteristic Auger transitions for Pu and O during sputter depth profiles were used in combination with previously measured sputter yields to determine the thickness of the oxide scale and provide insight into its chemistry. From this data, the parabolic kinetics for the Pu-Ga alloy were determined as a function of relative humidity, RH = 14–92%, and oxygen partial pressure, p(O 2 ) = 31–157 Torr, at 25°C. For each relative humidity investigated, the parabolic rate constant was found to be independent of oxygen partial pressure. Furthermore, power-law fits to the relative humidity effect on the rate constant was found to have a power of n = 1.265, indicating the diffusion species which rate-limits the reaction isn’t molecular water, which subsequent dissociates at the oxide-metal interface, or hydroxyl from dissociation at the gas-surface interface.

36 MATERIALS SCIENCE↗

Climatic factors and long-term trends of influenza-like illness rates in The Netherlands, 1970–2016

Highlights: • We studied the link between climatic factors and influenza-like illness (ILI) rate. • In the Netherlands, ILI rates dropped during 1970–2003, then started to rise again. • Weekly ILI count was inversely associated with humidity and temperature. • The early 2000s were a trend-reversal point for the climatic time series as well. • Seasonal average ILI rates and humidity (or temperature) were inversely correlated. Climatic factors affect the survival and transmissibility of respiratory viruses causing influenza-like illness (ILI), and we hypothesized that changes in absolute humidity and temperature may affect long-term trends of ILI incidence rate in temperate countries. We tested this hypothesis using ILI and meteorological time series in the Netherlands for the period 1970–2016.

54 ENVIRONMENTAL SCIENCES↗

Two proton-conductive hybrids based on 2-(3-pyridyl)benzimidazole molecules and Keggin-type heteropolyacids

Two proton-conductive organic/inorganic complexes were constructed by Keggin-type heteropolyacids and 2-(3-pyridyl)benzimidazole molecules. Single-crystal X-ray diffraction analyses revealed that two complexes crystallized in the monoclinic space group P2{sub 1}/c, exhibited different unit cell parameters, and presented different hydrogen-bonded networks constructed by 2-(3-pyridyl)benzimidazole molecules, [PMo{sub 12}O{sub 40}]{sup 3−} anions and solvent molecules. The results of thermogravimetric analyses suggest that two supramolecular complexes have different thermal stability based on the different hydrogen-bonded networks. Two complexes at 100 °C under 35–98% relative humidity showed a good proton conductivity of about 10{sup −3} S cm{sup −1}. The proton conductivities of two complexes under 98% relative humidity both increase on a logarithmic scale with temperature range from 25 to 100 °C. At 100 °C, both complexes showed poor proton conductivities of 10{sup −8}–10{sup −9} S cm{sup −1} under acetonitrile or methanol vapor. - Graphical abstract: Two molecular hybrids constructed by Keggin-type heteropolyacids and 2-(3-pyridyl)benzimidazole molecules showed good proton conductivities of 10{sup −3} S cm{sup −1} at 100 °C under 35–98% relative humidity. Display Omitted - Highlights: • 2-(3-Pyridyl)benzimidazole could form hydrogen bonds via the N–H groups. • Heteropolyacids have suitable characteristics to be used excellent proton conductors. • Two proton-conductive hybrids based on Keggin HPAs and 3-PyBim were constructed. • The structures were determined by using single-crystal X-ray diffraction data. • They showed good proton conductivities of 10{sup −3} S cm{sup −1} at 100 °C under 35–98% RH.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photocatalytic comparison of Cu- and Ag-doped TiO{sub 2}/GF for bioaerosol disinfection under visible light

Photocatalysts, TiO{sub 2}/glass fiber (TiO{sub 2}/GF), Cu-doped TiO{sub 2}/glass fiber (Cu–TiO{sub 2}/GF) and Ag-doped TiO{sub 2}/glass fiber (Ag–TiO{sub 2}/GF), were synthesized by a sol–gel method. They were then used to disinfect Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) in bioaerosols under visible light irradiation. TiO{sub 2}/GF did not show any significant disinfection effect. Both Cu and Ag acted as intermediate agents to enhance separation efficiency of electron–hole pairs of TiO{sub 2}, leading to improved photocatalytic activity of Cu–TiO{sub 2}/GF and Ag–TiO{sub 2}/GF under visible light. Cu in Cu–TiO{sub 2}/GF acted as a defective agent, increasing the internal quantum efficiency of TiO{sub 2}, while Ag in Ag–TiO{sub 2}/GF acted as a sensitive agent, enhancing the transfer efficiency of the electrons generated. The highest disinfection efficiencies of E. coli and S. aureus by Cu–TiO{sub 2}/GF were 84.85% and 65.21%, respectively. The highest disinfection efficiencies of E. coli and S. aureus by Ag–TiO{sub 2}/GF were 94.46% and 73.12%, respectively. Among three humidity conditions – 40±5% (dry), 60±5% (moderate), and 80±5% (humid) – the moderate humidity condition showed the highest disinfection efficiency for both E. coli and S. aureus. This study also showed that a Gram-negative bacterium (E. coli) were more readily disinfected by the photocatalysts than a Gram-positive bacterium (S. aureus). - Graphical abstract: Electron–hole pair separation mechanism of a metal-doped TiO{sub 2} system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Controlled Demolition and Reconstruction of Imidazolate and Carboxylate Metal–Organic Frameworks by Acid Gas Exposure and Linker Treatment

The metal-linker coordination bond in metal–organic frameworks (MOFs) can be unstable in humid and acid gas environments, leading to loss of crystallinity and porosity. This degradation is not necessarily irreversible; solvent-assisted crystal redemption (“SACRed”) has been shown to recover the physical and chemical properties of ZIF-8 exposed to humid SO 2 . This approach can also be useful in creating mixed-linker materials that might be challenging to produce via de novo synthesis. Here, we expand more generally the concept of controlled degradation of a MOF with acid gas, followed by treatment with a fresh linker solution, to the use of different template MOFs (ZIFs, UiO-66, and UiO-67) and acid gases (SO 2 and NO 2 in dry and humid conditions). Significant losses in porosity and crystallinity along with structural changes (acid gas-linker complexes and linker functionalizations) are observed in the acid gas-exposed MOF templates, and SACRed is shown to reconstruct these partially demolished MOFs with a high degree of structural recovery. Detailed structural and spectroscopic characterizations of the controlled degradation and subsequent recovery are presented and analyzed. Furthermore, these findings indicate the generality of controlled degradation and reconstruction as a means for linker replacement in a wider variety of MOFs and also create the potential for linker substitutions (with non-native linkers) to obtain new hybrid MOFs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

COVID-19: Effects of Environmental Conditions on the Propagation of Respiratory Droplets

As coronavirus disease 2019 (COVID-19) continues to spread, a detailed understanding on the transmission mechanisms is of paramount importance. The disease transmits mainly through respiratory droplets and aerosol. Although models for the evaporation and trajectory of respiratory droplets have been developed, how the environment impacts the transmission of COVID-19 is still unclear. In this study, we investigate the propagation of respiratory droplets and aerosol particles generated by speech under a wide range of temperatures (0–40 °C) and relative humidity (0–92%) conditions. We show that droplets can travel three times farther in low-temperature and high-humidity environment, whereas the number of aerosol particles increases in high-temperature and low-humidity environments. The results also underscore the importance of proper ventilation, as droplets and aerosol spread significantly farther in airstreams. This study contributes to the understanding of the environmental impact on COVID-19 transmission.

60 APPLIED LIFE SCIENCES↗