Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Grid-Forming Wind: Getting Ready for Prime Time With and Without Inverters

Variable wind power is one of the fastest-growing energy-generation technologies, harnessing the energy of wind, both on land and at sea. During the past decade, the global share of wind power has grown tremendously, and wind power is evolving into a major contributor to electricity supplies in many countries. In this journey, wind is also becoming a source of reliability services to the grid, which has required grid-supporting functions originally provided by synchronous generators, enabling very high levels of instantaneous penetration (ranging from 60 to 70% in some power systems). To get beyond this, a fundamental shift is required to address challenges associated with the transition to a grid with only a few remaining (or even without any) conventional synchronous generators while achieving a minimum acceptable level of stability.

energy consumption↗

Annual Report: Innovative Process Technologies (30 September 2013)

Innovative Process Technologies is concerned with the development of innovative cost-effective technologies that promote efficiency, environmental performance, availability of advanced energy systems, and the development of computational tools that shorten development timelines of advanced energy systems. The project is focused on five distinct research tasks: (1) Sensors and Controls, (2) Power Electronics and Energetic Materials, (3) Innovative Energy Concepts (IEC), (4) Computational Materials, and (5) Multiphase Flow.

20 FOSSIL-FUELED POWER PLANTS↗

GFM Inverter Hardware Testing

This presentence provides overview of NREL's testing capabilities and experience with advanced testing of multimegawatt grid-forming inverters.

GFM↗

Emergent structure in a dipolar Bose gas in a one-dimensional lattice

We consider an ultracold dipolar Bose gas in a one-dimensional lattice. For a sufficiently large lattice recoil energy, such a system becomes a series of nonoverlapping Bose-Einstein condensates that interact via the long-range dipole-dipole interaction (ddi). We model this system via a coupled set of nonlocal Gross-Pitaevskii equations (GPEs) for lattices of both infinite and finite extent. We find significantly modified stability properties in the lattice due to the softening of a discrete roton-like mode, as well as ''islands'' in parameter space where biconcave densities are predicted to exist and that only exist in the presence of the other condensates on the lattice. We solve for the elementary excitations of the system to check the dynamical stability of these solutions and to uncover the nature of their collapse. By solving a coupled set of GPEs exactly on a full numeric grid, we show that this emergent biconcave structure can be realized in a finite lattice with atomic {sup 52}Cr.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Learning-Based Load Control to Support Resilient Networked Microgrid Operations

Microgrids have proven to be an effective option for increasing the resiliency of critical end-use loads during extreme events. Building on past operational experiences, some microgrid operators are examining the potential to network microgrids to further improve resiliency. However, the frequency deviations experienced on isolated microgrids during transient events, such as switching operations, step increases in load, and loss of generation, are significantly larger than those typically seen on bulk transmission systems. The larger frequency deviations can cause a loss of inverter-connected assets, resulting in a loss of power to critical end-use loads. This paper presents a method of mitigating the impact of transient events by engaging end-use loads using Grid-Friendly Appliance TM (GFA) controllers. An online, i.e., real-time, device-level algorithm is presented, which adjusts individual GFA controller frequency set-points based on the operational characteristics of each end-use load, and on the changing grid dynamic characteristics. The presented method improves the dynamic stability of the networked microgrid operations while minimizing the interruptions to end-use loads. The presented work is validated with dynamic simulations using a modified version of the IEEE 123-node test system with three microgrids, using the GridLAB-D TM simulation environment.

Radhakrishnan, Nikitha↗

Computational fluid dynamics analysis of space shuttle main propulsion feed line 17-inch disconnect valves

A steady incompressible three-dimensional (3-D) viscous flow analysis was conducted for the Space Shuttle Main Propulsion External Tank (ET)/Orbiter (ORB) propellant feed line quick separable 17-inch disconnect flapper valves for liquid oxygen (LO2) and liquid hydrogen (LH2). The main objectives of the analysis were to predict and correlate the hydrodynamic stability of the flappers and pressure drop with available water test data. Computational Fluid Dynamics (CFD) computer codes were procured at no cost from the public domain, and were modified and extended to carry out the disconnect flow analysis. The grid generator codes SVTGD3D and INGRID were obtained. NASA Ames Research Center supplied the flow solution code INS3D, and the color graphics code PLOT3D. A driver routine was developed to automate the grid generation process. Components such as pipes, elbows, and flappers can be generated with simple commands, and flapper angles can be varied easily. The flow solver INS3D code was modified to treat interior flappers, and other interfacing routines were developed, which include a turbulence model, a force/moment routine, a time-step routine, and initial and boundary conditions. In particular, an under-relaxation scheme was implemented to enhance the solution stability. Major physical assumptions and simplifications made in the analysis include the neglect of linkages, slightly reduced flapper diameter, and smooth solid surfaces. A grid size of 54 x 21 x 25 was employed for both the LO2 and LH2 units. Mixing length theory applied to turbulent shear flow in pipes formed the basis for the simple turbulence model. Results of the analysis are presented for LO2 and LH2 disconnects.

Kandula, Max↗

Improved Offshore Wind Resource Assessment in Global Climate Stabilization Scenarios

This paper introduces a technique for digesting geospatial wind-speed data into areally defined -- country-level, in this case -- wind resource supply curves. We combined gridded wind-vector data for ocean areas with bathymetry maps, country exclusive economic zones, wind turbine power curves, and other datasets and relevant parameters to build supply curves that estimate a country's offshorewind resource defined by resource quality, depth, and distance-from-shore. We include a single set of supply curves -- for a particular assumption set -- and study some implications of including it in a global energy model. We also discuss the importance of downscaling gridded wind vector data to capturing the full resource potential, especially over land areas with complex terrain. This paperincludes motivation and background for a statistical downscaling methodology to account for terrain effects with a low computational burden. Finally, we use this forum to sketch a framework for building synthetic electric networks to estimate transmission accessibility of renewable resource sites in remote areas.

17 WIND ENERGY↗

High Fidelity BWR Fuel Simulations

This report describes the Consortium for Advanced Simulation of Light Water Reactors (CASL) work conducted for completion of the Thermal Hydraulics Methods (THM) Level 3 milestone THM.CFD.P13.03: High Fidelity BWR Fuel Simulation. High fidelity computational fluid dynamics (CFD) simulation for Boiling Water Reactor (BWR) was conducted to investigate the applicability and robustness performance of BWR closures. As a preliminary study, a CFD model with simplified Ferrule spacer grid geometry of NUPEC BWR Full-size Fine-mesh Bundle Test (BFBT) benchmark has been implemented. Performance of multiphase segregated solver with baseline boiling closures has been evaluated. Although the mean values of void fraction and exit quality of CFD result for BFBT case 4101-61 agreed with experimental data, the local void distribution was not predicted accurately. The mesh quality was one of the critical factors to obtain converged result. The stability and robustness of the simulation was mainly affected by the mesh quality, combination of BWR closure models. In addition, the CFD modeling of fully-detailed spacer grid geometry with mixing vane is necessary for improving the accuracy of CFD simulation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a smart DC grid model

Smart grid and distributed generation should be the solution of the global climate change and the crisis energy of the main source of electrical power generation which is fossil fuel. In order to meet the rising electrical power demand and increasing service quality demands, as well as reduce pollution, the existing power grid infrastructure should be developed into a smart grid and distributed power generation which provide a great opportunity to address issues related to energy efficiency, energy security, power quality and aging infrastructure systems. The conventional of the existing distributed generation system is an AC grid while for a renewable resources requires a DC grid system. This paper explores the model of smart DC grid by introducing a model of smart DC grid with the stable power generation give a minimal and compressed circuitry that can be implemented very cost-effectively with simple components. The PC based application software for controlling was developed to show the condition of the grid and to control the grid become ‘smart’. The model is then subjected to a severe system perturbation, such as incremental change in loads to test the performance of the system again stability. It is concluded that the system able to detect and controlled the voltage stability which indicating the ability of power system to maintain steady voltage within permissible rangers in normal condition.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modeling Arctic boundary layer cloud streets at grey-zone resolutions

To better understand how model resolution affects the formation of Arctic boundary layer clouds, we investigated the influence of grid spacing on simulating cloud streets that occurred near Utqiagvik (formerly Barrow), Alaska on 2 May 2013 and were observed by the Moderate Resolution Imaging Spectroradiometer (MODIS). The Weather Research and Forecasting model was used to simulate the clouds using nested domains with increasingly fine resolution ranging from a horizontal grid spacing of 27 km in the boundary-layer-parameterized mesoscale domain to a grid spacing of 0.111 km in the large-eddy-permitting domain. We investigated the model-simulated mesoscale environment, horizontal and vertical cloud structures, boundary layer stability, and cloud properties, all of which were subsequently used to interpret the observed roll-cloud case. Increasing model resolution led to a transition from a more buoyant boundary layer to a more shear-driven turbulent boundary layer. The clouds were stratiform-like in the mesoscale domain, but as the model resolution increased, roll-like structures, aligned along the wind field, appeared with ever smaller wavelengths. A stronger vertical water vapor gradient occurred above the cloud layers with decreasing grid spacing. With fixed model grid spacing at 0.333 km, changing the model configuration from a boundary layer parameterization to a large-eddy-permitting scheme produced a more shear-driven and less unstable environment, a stronger vertical water vapor gradient below the cloud layers, and the wavelengths of the rolls decreased slightly. In this study, only the large-eddy-permitting simulation with gird spacing of 0.111 km was sufficient to model the observed roll clouds.

Lai, Hui-Wen↗

Learning Local Volt/VAR Controllers Toward Efficient Network Operation with Stability Guarantees: Preprint

This paper considers the problem of voltage regulation in distribution network. The primary motivation is to keep voltages within pre-assigned operating limits by commanding the reactive power output of distributed energy resources (DERs) deployed in the grid. We develop a framework for developing local Volt/Var control that comprises of two main steps. In the first, exploiting historical data and for each DER, we learn a function representing desirable equilibrium points for the power network. These points approximate solutions of an Optimal Power Flow problem. In the second, we propose a control scheme for steering the network towards these favorable configurations. Theoretical conditions are derived to formally guarantee the stability of the developed control scheme and numerical simulations illustrate the effectiveness of the proposed approach.

data-driven control↗

PHIL Interface Design for Use With a Voltage-Regulated Amplifier

Power hardware-in-the-loop (PHIL) has emerged as a leading strategy to thoroughly assess the impact of proprietary inverter controls on a specific power system. The development of a PHIL test bed typically involves an inverter under test, a power amplifier, controllable DC supply, and a digital real-time simulator (DRTS) to simulate the power system under study. As a result of PHIL nonidealities, a form of digital compensation within the DRTS is used, which is commonly referred to as a PHIL interface. Many existing methods use legacy power amplifiers that do not contain internal voltage regulation. These existing interface methods are based around a voltage regulator within the DRTS and do not consider the interaction with the controls in newer amplifiers. In this study, a three-step approach of PHIL interface development for modern power amplifiers with built-in voltage regulation is introduced and is validated in hardware with a 30-kW grid-following inverter.

DRTS↗

Sensor enabled data-driven predictive analytics for modeling and control with high penetration of DERs in distribution systems

The electric power grid is undergoing a tremendous transformation due to the increasing penetration of renewable energy resources beginning with wind and more recently with the distributed energy resources (DERs) such as solar and battery storage. DERs have dramatically changed the role of the distribution systems in the overall power grid, and they are expected to contribute a significant portion of power generation in the future. If current trends for DERs continue, system operation and control will need to change dramatically for improved grid reliability and resiliency. As renewable resources increase in penetration, new and challenging operational, planning, and design problems are expected to emerge. Some of the key challenges that arise in the planning and operation of the future grid are: 1) Quantifying the impact of high DER penetration in distribution systems on bulk grid behavior over multiple time scales. 2) Identifying whether a particular DER configuration/settings have a large impact on the overall grid behavior. These challenges can be addressed in an offline manner using detailed T&D grid models and they can also be addressed in an online manner using sensor measurements. In particular, the advancement and planned growth in sensor technology in power grid over various voltage levels provide us with a unique opportunity to tackle these challenges from a data analytic perspective without needing detailed T&D grid models. A few questions that naturally arise when addressing the challenges from DERs using sensor data are: 1) How can we use limited sensor measurements to monitor & control voltage stability and small signal stability of the bulk system? 2) How can we ensure that the developed data analytic methods are robust to data availability and quality issues? 3) How can we compute the developed analytics in a scalable manner using streaming measurements? In this project, we addressed the aforementioned challenges arising from DERs and answered the questions raised above on how to effectively use the sensor measurements to enhance the reliability and performance of the electric grid. Thus, the overarching goal of this project is to develop effective reduced/representative system models from data that make the computational complexity sufficiently manageable so as to be useful to simulate, analyze, and even control complex non-linear power systems dynamics with large penetrations of DERs. In order to achieve the objective, the project team established a four-fold technical approach 1) Formulated a combined transmission-distribution co-simulation framework for data generation and validation, 2) Derived reduced/representative models of power systems based on data-driven methods for efficient computation and appropriate representation of system behavior, 3) Developed data driven characterization of power system behavior based on transfer operator theory, machine learning and optimization for model estimation, 4) Incorporated a scalable data management and processing architecture using distributed Kafka streaming applications that coordinate input data streams to the developed data analytics. The key accomplishments of the project are: 1) Development of a scalable multi-timescale T&D co-simulation framework (both for steady state and for dynamic co-simulation) using commercial solvers (PSSE and GridLAB-D). The steady-state T&D co-simulation interface is shared with our industry partner (PJM). 2) A structured reduced order dynamic model of distribution systems that can represent partial motor stalling along with a systematic procedure to derive the model parameters. 3) A PMU based online method to monitor, localize and mitigate fault-induced delayed voltage recovery using DER reactive support and load control in distribution systems. 4) Development of linear operator based robust methodologies for dynamic state estimation, uncertainty quantification, system identification and trajectory prediction for power system dynamics. 5) An adaptive damping control for utilizing wind energy resources to provide oscillation damping and system stability. 6) Implementation of Kafka-based framework for efficient processing of streaming data using Linux-based local virtual environment.

DER integration↗

Analysis and Reduction of Complex Networks Under Uncertainty

This effort was a collaboration with Youssef Marzouk of MIT, Omar Knio of Duke University (at the time at Johns Hopkins University) and Habib Najm of Sandia National Laboratories. The objective of this effort was to develop the mathematical and algorithmic capacity to analyze complex networks under uncertainty. Of interest were chemical reaction networks and smart grid networks. The statements of work for USC focused on the development of stochastic reduced models for uncertain networks. The USC team was led by Professor Roger Ghanem and consisted of one graduate student and a postdoc. The contributions completed by the USC team consisted of 1) methodology and algorithms to address the eigenvalue problem, a problem of significance in the stability of networks under stochastic perturbations, 2) methodology and algorithms to characterize probability measures on graph structures with random flows. This is an important problem in characterizing random demand (encountered in smart grid) and random degradation (encountered in infrastructure systems), as well as modeling errors in Markov Chains (with ubiquitous relevance!). 3) methodology and algorithms for treating inequalities in uncertain systems. This is an important problem in the context of models for material failure and network flows under uncertainty where conditions of failure or flow are described in the form of inequalities between the state variables.

97 MATHEMATICS AND COMPUTING↗

A robust spectral element implementation of the $k - τ$ RANS model in Nek5000/NekRS

The $k - ω$ Reynolds Averaged Navier Stokes (RANS) model is one of the industry standard approaches for modeling of turbulent flows. It performs better than the $k - ϵ$ model for low Reynolds number flows and is also more suitable for boundary layers with adverse pressure gradients. Major drawback of the model, however, is that the asymptotic value of $ω$ at the walls is singular, necessitating the use of a contrived “sufficiently” large value for $ω$ as the boundary condition for its transport equation. Here, this invariably leads to the solution being sensitive to near wall grid spacing. While an acceptable solution for low order (finite volume) methods, the excessive near wall gradients lead to persistent numerical stability issues in high order codes. To alleviate the problem, specifically in the context of the high order spectral element code Nek5000, a regularized $k - ω$ approach was formulated in our prior work (Tomboulides et al., 2018). The formulation, however, relies on the use of wall distance and its gradients for modeling the closure terms and can pose problems for simulations in complex geometries. This work presents a novel implementation of the $k - τ$ RANS model in Nek5000, where $τ = 1/ω$, eliminating the need for regularization, owing to the asymptotically bounded behavior of the source terms in the $τ$ transport equation, and also eliminating dependence on wall distance. Robustness and stability of the $k - τ$ model is ensured through implicit treatment of the source terms and their careful numerical implementation and demonstrated through several cases aimed at verification and validation. Studies include both canonical and engineering relevant problems, viz., turbulent channel flow, pipe flow, backward facing step, flow over NACA 0012 airfoil and flow in a T-junction. Results from the $k - τ$ model are shown to be consistent with regularized $k - ω$ model and also with the $k - ω$ SST model in OpenFOAM (for select studies). Comparison with experimental data is also shown, where available, to bolster validation efforts for the $k - τ$ model implementation through prediction of key turbulent quantities of interest.

Nek5000↗

Setting up of a low temperature in-situ ion implantation and channeling facility at Kalpakkam

A simple low temperature ion implantation and ion channeling facility has been set up. Low temperatures upto 70 K has been obtained on a goniometer sample holder by connecting to a continuous flow Helium cryostat with a copper braid. Charge integration is carried out with a transmission Faraday cup with 10 mm diameter aperture and four Faraday cups for performing ion implantation and an electron suppressed 1.5 mm aperture with a TEM grid of 60% beam transmission for ion beam analysis. Typical low temperature ion implantation and channeling experiments have been carried out. Stabilization at intermediate temperatures by controlling the heater at the sample holder and improvement of the achievable lowest temperature by having liquid nitrogen cooled heat shield are in progress.

43 PARTICLE ACCELERATORS↗

Microgrid to Microgrid Synchronization with Grid-Forming Inverters: Challenges and Solution

Research on network microgrids has primarily focused on control and optimization. However, application aspects such as microgrid-to-microgrid synchronization have not been fully addressed in existing literature. This paper first addresses the challenges of networking microgrids with grid-forming inverter in droop control. Then, it proposes a pre-synchronization algorithm to improves the synchronization speed and transient stability. To improve the speed, the phase difference between adjacent microgrids is minimized. Transients such as inrush current and oscillations are effectively mitigated by increasing the virtual impedance during interconnection. The proposed strategy allows smooth transitions when reconfiguration of the microgrids is needed. The applicability of this strategy to today’s microgrid systems is demonstrated through a validation in a 480V three-phase network microgrid testbed with commercial-grade inverters, protective devices, and switchgear.

Ferrari Maglia, Max↗

Integrated Transmission and Distribution Control

Distributed, generation, demand response, distributed storage, smart appliances, electric vehicles and renewable energy resources are expected to play a key part in the transformation of the American power system. Control, coordination and compensation of these smart grid assets are inherently interlinked. Advanced control strategies to warrant large-scale penetration of distributed smart grid assets do not currently exist. While many of the smart grid technologies proposed involve assets being deployed at the distribution level, most of the significant benefits accrue at the transmission level. The development of advanced smart grid simulation tools, such as GridLAB-D, has led to a dramatic improvement in the models of smart grid assets available for design and evaluation of smart grid technology. However, one of the main challenges to quantifying the benefits of smart grid assets at the transmission level is the lack of tools and framework for integrating transmission and distribution technologies into a single simulation environment. Furthermore, given the size and complexity of the distribution system, it is crucial to be able to represent the behavior of distributed smart grid assets using reduced-order controllable models and to analyze their impacts on the bulk power system in terms of stability and reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗