Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Evaluation of OH laser-induced fluorescence techniques for supersonic combustion diagnostics

The limitations on application of dye laser and narrowband tunable KrF excimer laser systems to planar OH fluorescence measurements in supersonic combustion test facilities are examined. Included in the analysis are effects of collisional quenching, beam absorption, fluorescence trapping, and signal strengths on achievable measurement accuracy using several excitation and detection options for either of the two laser systems. Dye-based laser systems are found to be the method of choice for imaging OH concentrations less than 10 exp 15 per cu cm, while the KrF based systems provide significant reduction in measurement ambiguity for concentrations in excess of 10 exp 15 per cu cm.

Quagliaroli, T. M.↗

Fe II fluorescence and anomalous C IV doublet intensities in symbiotic novae

The variation of absolute intensities of Bowen-excited Fe II emission in the symbiotic stars RR Tel, RX Pup, and AG Peg is examined. The C IV doublet intensity ratios in RR Tel were not anomalous between 1979 and 1989, and the ratio had typical values within the optically thin range. The intensity of individual Fe II Bowen-excited lines is correlated with the C IV 1548.2 A flux, suggesting the presence of a foreground Fe II region in which fluorescent-excited material responds to flux variations of C IV 1548.2 A. In RX Pup the combined fluxes of Fe II Bowen-pumped lines can account for an appreciable fraction of the flux deficit in the C IV 1548.2 A line when the C IV doublet ratio is less than the optically thick limit of unity. The Fe II Bowen lines in RX Pup exhibit a velocity range from 0 to 80 km/s, where several strong Fe II emission lines correspond to deep absorption structure in the C IV 1548.2 A line profile. In AG Peg and C IV 1548.2 A flux deficit cannot be explained by Fe II fluorescent absorption alone when the C IV doublet ratio anomaly is at an extreme.

Michalitsianos, A. G.↗

Doppler-shifted fluorescence imaging of velocity fields in supersonic reacting flows

The application of Doppler-shifted fluorescence imaging of velocity fields in supersonic reacting flows is analyzed. Focussing on fluorescence of the OH molecule in typical H2-air Scramjet flows, the effects of uncharacterized variations in temperature, pressure, and collisional partner composition across the measurement plane are examined. Detailed measurements of the (1,0) band OH lineshape variations in H2-air combustions are used, along with single-pulse and time-averaged measurements of an excimer-pumped dye laser, to predict the performance of a model velocimeter with typical Scramjet flow properties. The analysis demonstrates the need for modification and control of the laser bandshape in order to permit accurate velocity measurements in the presence of multivariant flow properties.

Allen, M. G.↗

Flow diagnostics of an arcjet using laser-induced fluorescence

A diagnostic has been developed to measure velocity and translational temperature in the plume of an arcjet thruster. Laser induced fluorescence with a narrowband CW laser is used to probe the Balmer alpha transition of excited atomic hydrogen. The velocity is determined from the Doppler shift of the fluorescence excitation spectrum while temperature is inferred from its shape. Analysis shows that while Doppler broadening is the only significant broadening mechanism, the fine structure of the transition must be accounted for. Near the exit plane, axial velocities vary from 4 to 14 km/s; radial velocities vary from 0 to 4 km/s; and swirl velocities are shown to be relatively small. Temperatures from 1000 to 5000 K indicate high dissociation fractions.

Liebeskind, John G.↗

Fluorescence Reveals Contamination From Adhesives

Contamination of nearby surfaces from ingredients in some adhesive materials detected by ultraviolet illumination and observation of resulting fluorescence. Identification of contaminants via telltale fluorescence not new; rather, significance lies in method of implementation and potential extension to wider variety of materials and applications.

Nikolia, William↗

Fluorescent-Antibody Measurement Of Cancer-Cell Urokinase

Combination of laboratory techniques provides measurements of amounts of urokinase in and between normal and cancer cells. Includes use of fluorescent antibodies specific against different forms of urokinase-type plasminogen activator, (uPA), fluorescence microscopy, quantitative analysis of images of sections of tumor tissue, and flow cytometry of different uPA's and deoxyribonucleic acid (DNA) found in suspended-tumor-cell preparations. Measurements provide statistical method for indicating or predicting metastatic potentials of some invasive tumors. Assessments of metastatic potentials based on such measurements used in determining appropriate follow-up procedures after surgical removal of tumors.

Morrison, Dennis R.↗

Planar laser-induced fluorescence imaging of OH in the exhaust of a bi-propellant thruster

Planar laser-induced fluorescence imaging of the hydroxyl radical has been performed on the flow produced by the exhaust of a subscale H2/O2 fueled bi-propellant rocket engine. Measurements were made to test the feasibility of OH (0,0) and (3,0) excitation strategies by using injection seeded XeCl and KrF excimer lasers, respectively. The flow is produced with hydrogen and oxygen reacting at a combustor chamber pressure of 5 atm which then exhausts to the ambient. The hydroxyl concentration in the exhaust flow is approximately 8 percent. Fluorescence images obtained by pumping the Q1(3) transition in the (0,0) band exhibited very high signals but also showed the effect of laser beam absorption. To obtain images when pumping the P1(8) transition in the (3,0) band it was necessary to use exceptionally fast imaging optics and unacceptably high intensifier gains. The result was single-shot images which displayed a signal-to-noise ratio of order unity or less when measured on a per pixel basis.

Paul, Phillip H.↗

An investigation of nonsimultaneous laser-induced fluorescence

An alternative to simultaneous, two-line laser-induced fluorescence for thermodynamic property measurement is presented. This spectroscopic approach is similar to multiple-overheat hot-wire anemometry and is based on laser excitation of different fluorescence transitions for separate, sequential wind tunnel runs. Both fluctuating and mean thermodynamic property measurements seem to be achievable with this method without exciting the transitions during the same laser pulse.

Fletcher, D. G.↗

Measurements of KrF laser-induced O2 fluorescence in high-temperature atmospheric air

Conditions for obtaining laser-induced O2 fluorescence using a tunable KrF laser has been determined theoretically and experimentally. With this laser source, O2 rotational temperature measurement is possible even in the absence of vibrational equilibrium. Temperature measurement using a two-line excitation scheme has been demonstrated in a high-temperature atmospheric-air furnace. A measurement uncertainty of 10.7 percent for the temperature range 1325-1725 K was realized. At atmospheric pressure, O2 LIF measurements are possible for air temperatures above 1250 K. Interference from OH fluorescence in reacting flows can be avoided by the proper selection of O2 transitions. Depletion of the ground state population by the incident laser is negligible for intensities below 7.5 x 10 to the 6th W/sq cm/per cm.

Grinstead, Jay H.↗

Performance of a multistep fluorescence-gated proportional counter for hard X-ray astronomy

Results from the first flight of our proportional counter in an imaging telescope led us to rebuild the detector. We have used a Penning gas mixture (xenon + 1 percent isobutylene) and introduced a preamplification region to improve the energy resolution. We have rebuilt the pressure vessel making novel use of molybdenum as the housing material in order to reduce the residual instrument background, particularly in the fluorescence-gated mode for which the detector design has been optimized. We have also increased the sensitive gas depth from 9 to 14 cm to further increase the sensitivity to both fluorescent pairs and conventional singles. Our calibrations have shown that the overall energy resolution of the detector has been enhanced by a factor of 2, and we predict that the sensitivity at float will increase by a factor of 3 in the 50-70 keV energy band.

Dietz, K. L.↗

Induced ClO vacuum ultraviolet fluorescence

Some vibronic transitions of ClO such as G(v-prime = 11 )-X(v-double prime = 10), G(v-prime = 5)-X(v-double prime = 3) and H(v-prime = 4)-X(v-double prime = 2), which promote overtones of X(2pi3/2) to bound Rydberg states, are nearly resonant with the 130.6 nm O-atom emission line and possess sizable Franck-Condon factors. On this basis broadband detection of 'O atom' fluorescence in experiments involving vibrationally excited ClO(X) is ascribed to the radiative decay of ClO(G, H) rather than to the formation of O atoms; these observations raise the probability of monitoring ClO(X; v = 0) by VUV-induced fluorescence.

Colussi, A. J.↗

Erosion rate diagnostics in ion thrusters using laser-induced fluorescence

We have used laser-induced fluorescence (LIF) to monitor the charge-exchange ion erosion of the molybdenum accelerator electrode in ion thrusters. This real-time, nonintrusive method was implemented by operating a 30cm-diam ring-cusp thruster using xenon propellant. With the thruster operating at a total power of 5 kW, laser radiation at a wavelength of 390 nm (corresponding to a ground state atomic transition of molybdenum) was directed through the extracted ion beam adjacent to the downstream surface of the molybdenum accelerator electrode. Molybdenum atoms, sputtered from this surface as a result of charge-exchange ion erosion, were excited by the laser radiation. The intensity of the laser-induced fluorescence radiation, which is proportional to the sputter rate of the molybdenum atoms, was measured and correlated with variations in thruster operating conditions such as accelerator electrode voltage, accelerator electrode current, and test facility background pressure. We also demonstrated that the LIF technique has sufficient sensitivity and spatial resolution to evaluate accelerator electrode lifetime in ground-based test facilities.

Gaeta, C. J.↗

Laser induced fluorescence of dental caries

Significant differences between the optical spectra taken from sound regions of teeth and carious regions have been observed. These differences appear both in absorption and in laser induced fluorescence spectra. Excitation by the 488 nm line of an argon ion laser beam showed a peak in the emission intensity around 553 nm for the sound dental material while the emission peak from the carious region was red-shifted by approximately 40 nm. The relative absorption of carious region was significantly higher at 488 nm; however its fluorescence intensity peak was lower by an order of magnitude compared to the sound tooth. Implications of these results for a safe, reliable and early detection of dental caries are discussed.

Albin, S.↗

Two-Beam multiplexed laser-induced fluorescence measurements of an argon arcjet plume

We describe a multiplexed, laser-induced fluorescence (LIF) technique with which radial and axial profiles of vector velocities of excited propellant species were obtained in the exhaust plume from a 300-W argon arcjet. Although the arcjet is a prototype, and although argon is not an interesting propellant from a propulsion perspective, the technique clearly demonstrates how a narrowband, frequency-stabilized ring-dye laser can be used to obtain simultaneous measurements of two velocity components in an arcjet plume and how a third signal from an optogalvanic cell can be used as a frequency reference. We also show that much information on the flow can be obtained by analyzing the Doppler widths and fluorescence intensities of the LIF data. Specifically, the data identify a boundary layer in the radial direction of the plume and a shock in the downstream region of the flow. Also, some flow anisotropy is observed, consistent with the assumption that the magnitude of the mean flow velocity fluctuates. The peak velocity on centerline remains roughly constant at 3 km/s throughout the expansion.

Ruyten, Wilhelmus M.↗

Examining Thermally Sprayed Coats By Fluorescence Microscopy

True flaws distinquished from those induced by preparation of specimens. Fluorescence microscopy reveals debonding, porosity, cracks, and other flaws in specimens of thermally sprayed coating materials. Specimen illuminated, and dye it contains fluoresces, emitting light at different wavelength. Filters emphasize contrast between excitation light and emission light. Specimen viewed directly or photographed on color film.

Street, Kenneth W., Jr.↗

Squeezing in phase-conjugated resonance fluorescence

Emission of resonance fluorescence by an atom near the surface of a four-wave mixing phase conjugator is considered. The dipole radiation field, regarded as a Heisenberg-operator field, is decomposed into plane waves with the aid of Weyl's representation of the Green's function for the wave equation. Each plane-wave component which is incident on the surface of the nonlinear medium, is reflected as its phase-conjugate image. Summation of all reflected plane waves then yields the phase conjugate replica of the incident dipole radiation. This field adds to the radiation which is emitted by the atom into the direction away from the medium. The condition under which squeezing occurs in the emitted resonance fluorescence is investigated.

Arnoldus, Henk F.↗

Remote sensing x ray fluorescence spectrometry for future lunar exploration missions

Measurement of discrete line X-ray emission from space can be used to obtain both qualitative and quantitative elemental surface composition information. Remote orbital X-ray elemental analysis is the measurement of characteristic X-rays following the interaction of solar X-rays with the surface of a given solid body. Thus, X-ray emission from a surface is strongly dependent on the incident solar spectrum as well as on the chemical composition of the surface. In this paper, the relationship between the solar flux and the major lunar element fluorescence and scattered X-ray flux is characterized. A model was developed to calculate lunar surface X-ray fluorescence emission spectra under a variety of solar conditions and, in particular, conditions that might be expected for a Lunar Scout mission proposed for 1995 or 1996. This time period should be during solar minimum.

Clark, Pamela E.↗

Two-Photon/Laser-Induced Fluorescence (TP/LIF) sensor

The Two-Photon/Laser-Induced Fluorescence (TP/LIF) technique is based on the stepwise excitation of the OH transitions, X(exp 2)II, v(exp '') = 0 yields X(exp 2)II, v(exp '') = 1 (lambda = 2.9 microns) and X(exp 2)II v(exp '') = 1 yields A(exp2)Sigma, v' = 0 (lambda = 345 nm) with background free fluorescence monitoring of the A(exp 2)Sigma, v' = 0 yields X(exp 2)II, v(exp '') = 0 transition near 309 nm. This technique has awaited the advent of a suitable mid-infrared (2.9 microns) laser source. Turnable mid-IR lasers now exist that are capable of meeting the specifications required of a high sensitivity TP/LIF OH sensor.

Bradshaw, John D.↗