Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Highly parallelisable simulations of time-dependent viscoplastic fluid flow with structured adaptive mesh refinement

We present the extension of an efficient and highly parallelisable framework for incompressible fluid flow simulations to viscoplastic fluids. The system is governed by incompressible conservation of mass, the Cauchy momentum equation, and a generalised Newtonian constitutive law. In order to simulate a wide range of viscoplastic fluids, we employ the Herschel-Bulkley model for yield-stress fluids with nonlinear stress-strain dependency above the yield limit. We utilise Papanastasiou regularisation in our algorithm to deal with the singularity in apparent viscosity. The resulting system of partial differential equations is solved using the IAMR (Incompressible Adaptive Mesh Refinement) code, which uses second-order Godunov methodology for the advective terms and semi-implicit diffusion in the context of an approximate projection method to solve adaptively refined meshes. By augmenting the IAMR code with the ability to simulate regularised Herschel-Bulkley fluids, we obtain efficient numerical software for time-dependent viscoplastic flow in three dimensions, which can be used to investigate systems not considered previously due to computational expense. We validate results from simulations using this new capability against previously published data for Bingham plastics and power-law fluids in the two-dimensional lid-driven cavity. In doing so, we expand the range of Bingham and Reynolds numbers which have been considered in the benchmark tests. Moreover, extensions to time-dependent flow of Herschel-Bulkley fluids and three spatial dimensions offer new insights into the flow of viscoplastic fluids in this test case, and we provide missing benchmark results for these extensions.

42 ENGINEERING↗

Assessment of Sodium Thermal Stratification Models Utilizing the TSTF Benchmark

As a result of certain transient scenarios, a thermally stratified layer of liquid sodium can develop in the bulk coolant volumes of a sodium-cooled fast reactor (SFR). In addition to the effects a stratification layer has on the temperature of the heat transport system, a stratification layer can also influence the transition to and establishment of natural circulation flow, which plays an important role in passive cooling and the inherent safety of a pool-type SFR. Therefore, the ability to accurately capture thermal stratification phenomena is important when demonstrating the safety basis of a pool-type SFR during transient sequences. The present work assesses various computational models with different fidelities in their ability to predict thermal stratification in the upper plenum of an SFR. Each computational model will be assessed using the data generated at the Thermal Stratification Test Facility (TSTF) located at the University of Wisconsin-Madison. Using measured flow rate and inlet temperature data, the measured temperature distributions of the tests are compared to the predictions of the lumped volume-based models in SAS4A/SASSYS-1, a 1D-based model in SAM, and a 3-D computational fluid dynamics (CFD) model using STAR-CCM+. The relative performance of the various computational methods is assessed with respect to key metrics such as bulk coolant temperature distribution and plenum exit temperature. A total of eight tests are analyzed, covering different combinations of flow rates (3 and 10 GPM) and upper internal structure (UIS) configurations (none, solid, porous, and open) The perfect mixing model of SAS4A/SASSYS-1 provides the highest accuracy when the flow rate is high and there is no UIS in the test vessel, as high flow rate injection promotes thermal mixing of the sodium in the test vessel. For most of the analyzed tests, the stratified volume model of SAS4A/SASSYS-1 is able to predict the delay in the outlet temperature drop and temperature distribution in the test vessel by a small number of layers to represent thermal stratification. However, the stratified volume model can only simulate a maximum of three temperature layers within a volume and when a layer approaches the elevation of the outlet, the predicted outlet temperature can demonstrate rapid, non-physical changes. The 1-D axial mixing model of SAM provides results that agree reasonably well with the measured data in the prediction of the temporal evolution of the outlet temperature with the exception of the case with a high flow rate and no UIS. The SAM 1-D model has a similar level of accuracy to CFD results when it comes to predicting the outlet temperature. CFD shows overall good agreement in predicting the temperature distribution in the test vessel and outlet temperature. As CFD can model the test vessel geometry in detail, it performs well in the cases of complex geometries such as tests that included a UIS and internal flow through the UIS resulting in active mixing of the coolant in the test vessel. Each of the models discussed in the present work has the potential to be useful during the various stages of reactor design, analysis, and licensing. The lumped-volume approach can be applied for fast turnaround safety calculations to obtain overall reactor behavior during transients. The 1-D models provide improved accuracy when stratification is expected for a relatively low increase in the computational cost. The CFD model can be utilized for confirmatory analysis of the 1-D model, when experimental measurements are not available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Film condensation with high heat fluxes and scaled experiments using pure steam for reactor containment cooling

Condensation tests were performed using a newly developed test facility for scaling the passive containment cooling system (PCCS) to a small modular reactor (SMR). The PCCS of the SMR plays a pivotal role in ensuring greater safety, reliability, and compactness than what is afforded by traditional reactors. Therefore, a well-designed PCCS is essential to SMRs. However, previous studies and test data were unsuitable for scaling, due to high variation in the test geometry and operating conditions. This study intends to close this research gap by using a novel designed scaled test facility consisting of vertical condensing test sections featuring 1-, 2-, and 4-inch-diameter condensing tubes with annular water cooling, and by applying superheated and saturated steam with different steam mass flow ranges of 5–25 g/s. Further, the primary test data, including axial temperatures, mass flow rates, and pressures, were used in conjunction with a standard data reduction method to estimate critical parameters such as heat fluxes, heat transfer coefficients, and condensation rates. These scaled test data would support improving empirical correlations and validating condensation models to identify scaling distortion for SMR PCCSs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A study of solid particle flow characterization in solar particle receiver

The solid particle receiver (SPR) is a direct absorption receiver in which solar energy heats a curtain of falling ceramic particle to a temperature in excess of 1000 C. A small scale test platform was built to investigate particle flow properties. The curtain was comprised of approximately 697 {mu}m ceramic particles that were dropped within the receiver cavity of the test platform. Tests were conducted to experimentally determine the distribution of particles velocity, curtain thickness, and curtain opacity along a drop length of approximately 3 m. Velocity data were measured using a high speed digital camera to obtain images of the particle flow at 1000 frames per second with an exposure time of 100 {mu}s. Five mass flow rates ranging from 1 kg/s-m to 22 kg/s-m were examined, and it was found that all flows approached a terminal velocity of about 6-7 m/s in a vertical drop distance of 3 m. The experimental results were validated with computational results and were found in excellent agreement with the simulation results. In addition, a similar study was performed with various sizes of the particles to better understand how the particle flow characteristics were affected by the size of the particles. (author)

14 SOLAR ENERGY↗

Rotating Detonation Combustion for Gas Turbines: Modeling and System Synthesis to Exceed 65% Efficiency Goal (Phase II)

As of May 2019, all RDE test hardware and test operations were completed for this program. Over 700 hot fire tests were conducted at 4 facilities with 7 RDE assemblies, with the data available for future analysis. In particular, measured static and dynamic pressure and computational fluid dynamics (CFD) provided basis for pressure gain combustion (PGC) analysis of the Engineering Scale RDE. It was demonstrated via measurements and CFD that a carefully designed diffuser can recover some total pressure of the highly oscillatory RDE exhaust. In general, the isolator/injector is largest contributor of pressure losses; however a low loss design was demonstrated that improves significantly on previous natural-gas/air RDEs. Also, a tailored injector and mixing technique was demonstrated that allowed NG-air RDE operation with overall equivalence ratio of less than 0.6. CFD models by AR, the UofM and Purdue University were extensively used throughout the program to refine diffuser design for improved pressure recovery, to simulate injection and mixing, to estimate turbine interaction, to estimate combustor pressure gain anchored with test data and to provide input to other design and analytical tasks. CFD analyses were completed for many of the configurations tested at Purdue with the 13.4” RDE including the shark fin and low area ratio isolators. Results were compared favorably to available hot fire test particle image velocimetry (PIV) measurements and wave speeds. The results of these CFD analyses suggest a modest pressure gain of 33% with a sufficiently low area ratio isolator. A thermodynamic power plant system model was set up which utilizes an RDE combustor. The performance of the RDE combustor module was scaled based on measurements from the Engineering Scale RDE tests with low loss injector and tailored fuel flow. This combined model indicates potential for significant plant efficiency improvement. The successful tailored fuel injection test result with lower than .6 equivalence ratio has implication that a power plant can use a RDE combustor configuration where all the air flows through the combustion zone thereby not requiring a bypass mixer. In this configuration, the results of the natural gas combined cycle (NGCC) plant system indicate net efficiency of 66.4%.

02 PETROLEUM↗

Visualization of flow interaction in a channel flow produced by a pair of helically coiled rods

Helically coiled tubes have been considered in the design of steam generators or heat exchangers of next generation nuclear power plants. Its compactness, efficiency, and the capability to absorb thermal expansion are desirable for nuclear reactor designs. However, the complex flow generated by the helically coiled geometry can result in flow induced vibration (FIV). In order to predict the FIV, there have been efforts using Computational Fluid dynamics (CFD)4, 5 to be coupled with multi-mechanics simulations. However, it is required to validate CFD to have confidence in capturing the flow structure characteristics of the transient complex flow behavior and fluctuation. In the present study, a simplified helically coiled steam generator (HCSG) design experiment was built acquiring data for CFD validation purpose. It is not perfect representation of the multiple rods, however, the current test facility produced transient data of the flow interaction between the rods and flow fluctuations near the rods. Particle Image Velocimetry (PIV) was applied to visualize the turbulent flow in a channel with slant rods. The two dimensional turbulent flow fields were analyzed. The velocity components were defined as below. u = U + u' (1) v = V + v' (2) where u is the lateral velocity on x-axis, v is the vertical velocity on y-axis, U and V are the mean velocities, and u' and v' are the fluctuation. Reynolds number, Re, was calculated using the rod diameter, d = 15.9 mm, and the upstream approach velocity, V{sub 0} = 0.5 m/s. Re = V{sub 0} d/η (3) where η is the kinematic viscosity of water. The experiment was conducted at Re ≅ 9,000 considering the currently reasonable computing power. Flow visualization in a flow channel produced by helically coiled rods was performed using PIV. The mean velocity field and streamlines were presented in this paper. The vortical flow structures in the cavity between rods were observed. Because of the asymmetric geometry, the flow profile was skewed. Additional measurements and transient analysis will be conducted to produce benchmark data for FIV study using CFD. Also, a test facility with a 5-rod heat exchanger design is operating to produce more data as a further work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Catalytic Reduction of Residual Oxygen for the Purification of Carbon Dioxide Streams from Pressurized Oxy-Combustors

Pressurized oxy-combustion (OC) is regarded as an energy-efficient alternative to atmospheric OC. To utilize the captured carbon dioxide (CO2) from pressurized OC for enhanced oil recovery or carbon storage in geological formations, the CO2 product stream must meet the required purity specifications. One major impurity in OC flue gases is residual O2 (e.g., 3 vol%). In this study, a catalytic approach has been investigated to remove the residual O2 through a reduction reaction with injected methane (CH4) in a reverse-flow fixed-bed (RFFB) reactor. The performance was tested for a supported copper (Cu)-based catalyst synthesized by incipient wetness impregnation and a cobalt-manganese (CoMn) oxide catalyst synthesized by a coprecipitation method. A commercial Cu-based catalyst was also studied as the reference. Experimental results revealed that under the reverse-flow operation, the temperature profiles in the reactor were symmetrical on both sides of the catalyst zone and were more homogenous than those under the conventional one-direction-flow operation. Among the tested catalysts, the CoMn catalyst was the most reactive for promoting the reduction of O2 with CH4, able to attain >95% O2 removal at 475 °C and a gas hourly space velocity (GHSV) of 18,000 h-1 with a feed gas containing 3 vol% O2. Under all experiments, the concentrations of carbon monoxide (CO) were lower than 30 ppmv in the effluent gas streams. The reaction between O2 and CH4 could be depicted by using the Mars–van Krevelen redox mechanism based on a two-step reduction–oxidation reaction pathway.

36 MATERIALS SCIENCE↗

Performance of the Fluidized Bed Steam Reforming product under hydraulically unsaturated conditions

Several candidates for supplemental low-activity waste (LAW) immobilization at the Hanford site in Washington State, USA are being considered. One waste sequestering technology considered is Fluidized Bed Steam Reforming (FBSR). The granular product resulting from the FBSR process is composed primarily of an insoluble sodium aluminosilicate matrix with the dominant phases being feldspathoid minerals with a 1:1:1 molar ratio of Na, Al and Si. To demonstrate the durability of the product, which can be disposed of at the unsaturated Integrated Disposal Facility (IDF) at Hanford, a series of tests has been performed using the Pressurized Unsaturated Flow (PUF) system, which allows for the accelerated weathering of the solid materials. The system maintains hydraulically unsaturated conditions, thus mimicking the open-flow and transport properties that will be present at the IDF. Two materials were tested using the system: 1) the FBSR granular product and 2) the FBSR granular product encapsulated in a geopolymer to form a monolith. Results of the experiments show a trend of relatively constant effluent concentration of Na, Si, Al, and Cs as a function of time from both materials. The elements I and Re show a steady release throughout the yearlong test from the granular material but their concentrations seem to be increasing at one year from the monolith material. This result suggests that these two elements may be present in the sodalite cage structure rather than in the predominant nepheline phase because their release occurs at a different rate compared to nepheline phase. Also, these elements to not seem to reprecipitate when released from the starting material. Calculated one-year release rates for Si are on the order of 10 6 g/(m2 d) for the granular material and 10 5 g/(m2 d) for the monolith material while Re release is seen to be two orders of magnitude higher than Si release rates. SEM imaging and XRD analysis show how the alteration of the two materials is dependent on their depth in the column. This phenomenom is a result of depth-dependent solution concentrations giving rise chemical environments that may be supersaturated with respect to a number of mineral phases.

Fluidized Bed Steam Reforming↗

Assessing Adaptive Mesh Refinement (AMR) in a Forced Shallow-Water Model with Moisture

Two forced shallow-water flow scenarios are explored in a 2D fourth-order finite-volume dynamical core with adaptive mesh refinement (AMR) to investigate AMR’s ability to track and resolve complex evolving features. Traditional shallow-water test cases are mainly characterized by large-scale smooth flows that do not effectively test the multiscale abilities of variable-resolution and AMR models to resolve sharp gradients and small-scale flow filaments. Therefore, adding forcing mechanisms to the shallow-water system to model key atmospheric processes adds complexity and creates small-scale phenomena. These can serve as foci for dynamic grid refinement while remaining simple enough to study the numerical design of a model’s dynamical core. The first shallow-water flow scenario represents a strengthening, tropical cyclone–like, vortex that is driven by a Betts–Miller-like convection scheme. The second shallow-water test is built upon a barotropically unstable jet with an added Kessler-like warm rain scheme that leads to precipitating frontal zones. The key feature of both tests is that there is significant sensitivity to the model grid while converging (structurally) at high resolution. Both test cases are investigated for a series of uniform resolutions and a variety of AMR tagging criteria. The AMR simulations demonstrate that grid refinement can resolve local features without requiring global high-resolution meshes. However, the results are sensitive to the refinement criteria. Criteria that trigger refinement early in a simulation reproduce the uniform-resolution reference solutions most reliably. Finally, in contrast, AMR criteria that delay refinement for several days require careful tuning of the AMR thresholds to improve results compared with uniform-resolution simulations.

54 ENVIRONMENTAL SCIENCES↗

Utah FORGE: Wells 16A(78)-32 and 16B(78)-32 Extended Circulation Test Data - August and September 2024

The dataset includes data collected during an extended circulation test conducted at the Utah FORGE site between August 8 and September 5, 2024. It provides uncorrected, raw digital data from the test, along with calibration information and a final report detailing the test procedures and corrections. The data is bundled in a single .zip file containing both field calibration and test data. Files include manual calibration data for temperature, pressure, and flow meters, as well as uncorrected, time-stamped measurements recorded in 30-second intervals, such as wellhead pressures, flow rates, and temperatures for wells 16A(78)-32 and 16B(78)-32. Additionally, the final report offers insights into the test methodology and provides guidelines on how to apply field calibrations to correct the raw Pason data.

15 GEOTHERMAL ENERGY↗

A comparative analysis of numerical approaches for the description of gas flow in clay-based repository systems: From a laboratory to a large-scale gas injection test

There is nowadays a consensus among many countries that geological disposal is a favourable solution for the long-term management. Although different host formations and different barrier systems are under consideration around the world, clay-based materials form an important component for waste isolation in most national programmes. Hence, a good comprehension of the effect of gas flow on the hydro-mechanical behaviour of clay-based soils is essential, both at laboratory and field scale. Task B under the international cooperative project DECOVALEX-2023 has recently shown that, after some enhancement, models can be employed to reproduce laboratory scale tests, even with different sample geometries 37 . However, further work is required to understand whether they can be applied to simulate a large-scale experiment. Up-scaling of models for the advective transport of gas through clay-based low permeable material presents a number of problems related to the difficulty in obtaining consistent hydrogeological parameters and constitutive relationships at both laboratory and field scale. Based on a unique dataset from a large-scale gas injection test (Lasgit) performed at the Äspö Hard Rock Laboratory (Sweden), Task B within DECOVALEX-2023 has explored the refinement of these numerical strategies applied to the simulation of gas flow. Work performed within the task reveals that codes do not need to be substantially modified from the laboratory models to reproduce full-scale tests: indeed, model parameters calibrated and validated at laboratory scale have been applied to predict field scale gas flow at Lasgit, including peak gas pressure and injected cumulative gas volume. By means of (1) the introduction of interfaces between blocks to reflect the experimental configuration and the (2) adjustment of some parameters (e.g., higher permeability), the updated models are able to represent most of the key features observed in the experimental data, even at a large scale.

Tamayo-Mas, E↗

Full Coverage Shaped Hole Film Cooling in an Accelerating Boundary Layer with High Free-Stream Turbulence

Full coverage shaped-hole film cooling and downstream heat transfer measurements have been acquired in the accelerating flows over a large cylindrical leading edge test surface. The shaped holes had an 8° lateral expansion angled at 30° to the surface with spanwise and streamwise spacings of 3 diameters. Measurements were conducted at four blowing ratios, two Reynolds numbers and six well documented turbulence conditions. Film cooling measurements were acquired over a four to one range in blowing ratio at the lower Reynolds number and at the two lower blowing ratios for the higher Reynolds number. The film cooling measurements were acquired at a coolant to free-stream density ratio of approximately 1.04. The flows were subjected to a low turbulence condition (Tu = 0.7%), two levels of turbulence for a smaller sized grid (Tu = 3.5%, and 7.9%), one turbulence level for a larger grid (8.1%), and two levels of turbulence generated using a mock aero-combustor (Tu = 9.3% and 13.7%). Turbulence level is shown to have a significant influence in mixing away film cooling coverage progressively as the flow develops in the streamwise direction. Effectiveness levels for the aero-combustor turbulence condition are reduced to as low as 20% of low turbulence values by the furthest downstream region. The film cooling discharge is located close to the leading edge with very thin and accelerating upstream boundary layers. Film cooling data at the lower Reynolds number, show that transitional flows have significantly improved effectiveness levels compared with turbulent flows. Downstream effectiveness levels are very similar to slot film cooling data taken at the same coolant flow rates over the same cylindrical test surface. However, slots perform significantly better in the near discharge region. These data are expected to be very useful in grounding computational predictions of full coverage shaped hole film cooling with elevated turbulence levels and acceleration. IR measurements were performed for the two lowest turbulence levels to document the spanwise variation in film cooling effectiveness and heat transfer.

20 FOSSIL-FUELED POWER PLANTS↗

SAM Two-Phase Flow Model Development and Applications for Operational Transients in Advanced Reactors

As advanced nuclear technologies continue to develop, the need for the flexible operation and generation of these advanced reactors becomes necessary to maximize economic potential. As large-scale experiments are not always feasible, modeling and simulations of advanced reactors play a crucial role in design optimization and analysis. The SAM (System Analysis Module) code developed at Argonne National Laboratory is a state-of-the-art system-level thermal-hydraulic code aimed at simulating advanced reactor systems. Recent code developments have implemented two-phase flow modeling using the homogeneous equilibrium model, and a new steam generator component has been developed to utilize the two-phase flow implementation. In addition to verification tests, a load-following simulation was performed to model a realistic load-following transient in a proposed integrated system consisting of a conceptual advanced reactor known as the Advanced Burner Test Reactor (ABTR) and thermal energy storage (TES) tanks. The integrated system model uses two large TES tanks designed for sodium and a model helical coil steam generator to simulate the operational load-following transient. The flow rates of the feedwater and secondary loops are regulated to meet a prescribed steam generator load consistent with the electricity demand over a 24-h period. In conclusion, the results found the ABTR system was able to maintain stable reactor conditions and primary- and secondary-side characteristics over the course of the load-following transient.

Advanced Burner Test Reactor (ABTR)↗

Performance Evaluation of a Prototype Moving Packed-Bed Particle/sCO 2 Heat Exchanger

Particle heat exchangers are a critical enabling technology for next generation concentrating solar power (CSP) plants that use supercritical carbon dioxide (sCO 2 ) as a working fluid. This report covers the design, manufacturing and testing of a prototype particle-to-sCO 2 heat exchanger targeting thermal performance levels required to meet commercial scale cost targets. In addition, the the design and assembly of integrated particle and sCO 2 flow loops for heat exchanger performance testing are detailed. The prototype heat exchanger was tested to particle inlet temperatures of 500 °C at 17 MPa which resulted in overall heat transfer coefficients of approximately 300 W/m 2 -K at the design point and cases using high approach temperature with peak values as high as 400 W/m 2 -K

14 SOLAR ENERGY↗

Bench-scale studies of in-duct mercury capture using cupric chloride-impregnated carbons

A brominated activated carbon (Darco Hg-LH) and cupric chloride-impregnated activated carbon (CuCl{sub 2}-ACs) sorbent have been tested in a bench-scale entrained-flow reactor system which was developed for simulating in-flight mercury capture in ducts upstream of particulate matter control devices. The bench-scale experimental system has been operated with the conditions of a residence time of 0.75 s and a gas temperature of 140{sup o}C to simulate typical conditions in the duct of coal-fired exhaust gas. In addition, sorbent deposition on walls which can occur in a laboratory-scale system more than in a full-scale system was significantly reduced so that additional mercury capture by the deposited sorbent was minimized. In the entrained-flow system, CuCl{sub 2}-ACs demonstrated similar performance in Hg adsorption and better performance in Hg{sup 0} oxidation than Darco Hg-LH. In addition, the carbon content of those sorbents was found to determine their Hg adsorption capability in the entrained-flow system. The bench-scale entrained-flow system was able to demonstrate the important Hg adsorption and oxidation characteristics of the tested sorbents. 18 refs., 9 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Full coverage shaped-hole film cooling in an accelerating boundary layer with high freestream turbulence

Full coverage shaped-hole film cooling and downstream heat transfer measurements have been acquired in the accelerating flows over a large cylindrical leading edge test surface. The shaped holes had an 8 deg lateral expansion angled at 30 deg to the surface with spanwise and streamwise spacings of 3 diameters. Measurements were conducted at four blowing ratios, two Reynolds numbers, and six well documented turbulence condi-tions. Film cooling measurements were acquired over a four to one range in blowing ratio at the lower Reynolds number and at the two lower blowing ratios for the higher Reynolds number. The film cooling measurements were acquired at a coolant to free-stream density ratio of approximately 1.04. The flows were subjected to a low turbulence (LT) condition (Tu = 0.7%), two levels of turbulence for a smaller sized grid (Tu = 3.5%and 7.9%), one turbulence level for a larger grid (8.1%), and two levels of turbulence generated using a mock aerocombustor (AC) (Tu = 9.3% and 13.7%). Turbulence level is shown to have a significant influence in mixing away film cooling coverage progressively as the flow develops in the streamwise direction. Effectiveness levels for the AC turbu-lence condition are reduced to as low as 20% of LT values by the furthest downstream region. The film cooling discharge is located close to the leading edge with very thin and accelerating upstream boundary layers. Film cooling data at the lower Reynolds number show that transitional flows have significantly improved effectiveness levels compared with turbulent flows. Downstream effectiveness levels are very similar to slot film cooling data taken at the same coolant flow rates over the same cylindrical test surface. However, slots perform significantly better in the near discharge region. These data are expected to be very useful in grounding computational predictions of full coverage shaped-hole film cooling with elevated turbulence levels and acceleration. Lastly, infrared (IR) measurements were performed for the two lowest turbulence levels to document the spanwise variation in film cooling effectiveness and heat transfer.

20 FOSSIL-FUELED POWER PLANTS↗

The Hydrogeologic Character of the Lower Tuff Confining Unit and the Oak Springs Butte Confining Unit in the Tuff Pile Area of Central Yucca Flat

The lower tuff confining unit (LTCU) in the Yucca Flat Corrective Action Unit (CAU) consists of a monotonous sequence of pervasively zeolitized volcanic tuff (i.e., mostly bedded with lesser nonwelded to poorly welded tuff; not fractured) (Bechtel Nevada, 2006). The LTCU is an important confining unit beneath Yucca Flat because it separates the alluvial and volcanic aquifers, where many underground nuclear tests were conducted, from the regional lower carbonate aquifer. Recent sub-CAU-scale modeling by Los Alamos National Laboratory in the Tuff Pile area of Yucca Flat (Boryta, et al., in review) includes postulated low-porosity, high-permeability zones (i.e., fractured welded-tuff aquifers) within the LTCU. This scenario indicates that such postulated low-porosity, high-permeability zones could provide fast-path lateral conduits to faults, and eventually to the lower carbonate aquifer. A fractured and faulted lower carbonate aquifer is postulated to provide a flow path(s) for underground test-derived contaminants to potential offsite receptors. The ramifications of such a scenario are obvious for groundwater flow and contaminant migration beneath Yucca Flat. This paper describes the reasoning for not including postulated low-porosity, high-permeability zones within the LTCU in the Tuff Pile area or within the LTCU in the Yucca Flat CAU-scale model. Both observational and analytical data clearly indicate that the LTCU in the Tuff Pile area consists of pervasively zeolitic, nonwelded to poorly welded tuffs that are classified as tuff confining units (i.e., high-porosity, low-permeability). The position regarding the LTCU in the Tuff Pile area is summarized as follows: • The LTCU in the Tuff Pile area consists of a monotonous sequence of predominantly zeolitic nonwelded to poorly welded tuffs, and thus is accurately characterized hydrogeologically as a tuff confining unit (aquitard) in the Yucca Flat-Climax Mine hydrostratigraphic framework model (Bechtel Nevada, 2006). • No welded-tuff (or lava-flow aquifers), referred to as low-porosity, high-permeability zones in Boryta et al. (in review), are present within the LTCU in the Tuff Pile area. • Fractures within the LTCU are poorly developed, a characteristic of zeolitic tuffs; and fracture distributions are independent of stratigraphic and lithologic units (Prothro, 2008). • Groundwater flow and radionuclide transport will not be affected by laterally extensive zones of significantly higher permeability within the LTCU in the Tuff Pile area. Although not the primary focus of this report, the hydrogeologic character of the Oak Spring Butte confining unit (OSBCU), located directly below the LTCU, is also discussed. The OSBCU is lithologically more diverse, and does include nonwelded to partially welded ash-flow tuffs. However, these older ash-flow tuffs are poorly welded and altered (zeolitic to quartzofeldspathic), and consequently, would tend to have properties similar to a tuff confining unit rather than a welded-tuff aquifer.

54 ENVIRONMENTAL SCIENCES↗

Computer Programs For Analysis Of Thermally Reactive Tracer Tests In Geothermal Reservoirs

The Tracer Analysis Toolbox (TAT) is a stand-alone executable software package that focuses on reservoir monitoring, using changes in concentration of thermally degrading tracers between and injection well and a production well to reflect the temperature-time histories along flow paths through the reservoir. By conducting such tests periodically, the thermal evolution of the flow paths connecting injection wells to production wells can be monitored. Because this approach is sensitive to temperature along the whole path, it can detect changes well before they occur at the distal end of the path (i.e., the production well). Thus, the thermally degrading tracer method provides early detection of thermal decline before it impacts that well. The goal of TAT is to simplify planning of a reactive tracer monitoring campaign and interpretation of results by providing: (1) tracer test planning and analysis tools to define the necessary kinetic parameters, injection concentrations, and other tracer parameters that are suitable for the expected reservoir residence time and temperature, (2) identification of tracers with suitable characteristics (defined by (1)) and (3) a suite of analysis programs to analyze tracer test results.

Plummer, MitchellAaron [Idaho National Laboratory ↗