Algebraic Multigrid with Filtering: An Efficient Preconditioner for Interior Point Methods in Large-Scale Contact Mechanics Optimization

Large-scale contact mechanics simulations are crucial in many engineering fields such as structural design and manufacturing. In the frictionless case, contact can be modeled by minimizing an energy functional; however, these problems are often nonlinear, nonconvex, and increasingly difficult to solve as mesh resolution increases. In this work, we employ a Newton-based interior-point (IP) filter line-search method, an effective approach for large-scale constrained optimization. While this method converges rapidly, each iteration requires solving a large saddle-point linear system that becomes ill-conditioned as the optimization process converges, largely due to IP treatment of the contact constraints. Such ill-conditioning can hinder solver scalability and increase iteration counts with mesh refinement. Here, to address this, we introduce a novel preconditioner, algebraic multigrid with filtering (AMGF), tailored to the Schur complement of the saddle-point system. Building on the classical AMG solver, commonly used for elasticity, we augment it with a specialized subspace correction that filters near null space components introduced by contact interface constraints. Through theoretical analysis and numerical experiments on a range of linear and nonlinear contact problems, we demonstrate that the proposed solver achieves mesh independent convergence and maintains robustness against the ill-conditioning that notoriously plagues IP methods. These results indicate that AMGF makes contact mechanics simulations more tractable and broadens the applicability of Newton-based IP methods in challenging engineering scenarios. More broadly, AMGF is well suited for problems, optimization or otherwise, where solver performance is limited by a low-dimensional subspace, such as those arising from localized constraints, interface conditions, or model heterogeneities. This makes the method widely applicable beyond contact mechanics and constrained optimization.

Mathematics and Computing↗

Bloom filter de-identifier

A bloom filter is a binary data structure that is designed to be memory efficient and able to determine whether an element is present in a set. The bloom filter is a probabilistic data structure. It can tell you whether an element, or set of elements, is likely to exist within a set. It can also tell you whether an element, or set of elements, does not exist within a set. So false positives are probable, but false negatives are not. Our novel approach utilizes the bloom filter to determine how many bigrams (two letter sequence) each value has in common. The resulting metric approximates the relative similarity of two text values.

Bleeker, Amelia↗

Particle Filter Based Inference Testing

The primary intent of PAR-FIT (Particle Filter based Inference Testing) is to provide hard inductive evidence that a machine learning model is capable and proven for an individual test input. By examining training data used to form the underlying model functional correlation, an estimate of the reliability that a model will make the correct prediction can be made. The Sequential Probability Ratio Test is used to derive a qualitative evaluation for reliability based on hypothesis testing. The PAR-FIT framework achieves this by implementing a particle filter and the sequential probability ratio test algorithms on the machine learning model training data to determine relevancy of new individual test samples to the training dataset. The kernel function evaluates the local proximity and density of training data used to derive a prediction outcome. Particles are used to probabilistically determine which training data to evaluate for proximity. For test samples that are within a close proximity to and surrounded by multiple training data points, the evaluated reliability of the prediction is high. For test samples that are anomalies not represented by the training dataset, in low density data clusters, or are far from existing data points, the evaluated reliability is low as insufficient training evidence exists to suggest the model is capable of making the correct prediction. Sequential Probability Ratio Test is further used to determine when a hypothesis on whether a signal can be rejected or accepted for use. The ratio test collects sequence information from the particle filter to test whether the signal is anomalous or normal via hypothesis testing of the underlying distributions.

Chen, Edward [Idaho National Laboratory (INL), Ida↗

Assessment of Low-Level Pu Isotope Ratio Measurements Using Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS/MS) Equipped with a Pre-Mass Filter

We present an initial investigation into the performance of a multicollector inductively coupled plasmamass spectrometer equipped with a pre-mass filter (Neoma MC-ICP-MS/MS) for making plutonium (Pu) isotope ratio measurements on solutions containing low level (i.e., pg mL –1 ) Pu concentrations. This assessment was achieved by comparison of the 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu ratios attained over a one month period on the MC-ICP-MS/MS with the long-term (∼1 year) performance observed on the predecessor MC-ICP-MS (Neptune Plus) instrument each equipped with an equipped with an APEXΩ desolvating nebulizer for repeated measurements of certified reference materials from New Brunswick Program Office (NBL PO) CRM 136a and CRM 137. The MC-ICP-MS/MS performance of repeated measurement of CRM 136a (n = 20) resulted in mean values of 240 Pu/ 239 Pu = 0.1448 ± 0.0006, 241 Pu/ 239 Pu = 0.00371 ± 0.00006, and 242 Pu/ 239 Pu = 0.00682 ± 0.00006 (k = 2). The CRM 137 (n = 20), analyzed during the same analytical sessions, produced mean values for 240 Pu/ 239 Pu = 0.2414 ± 0.0006, 241 Pu/ 239 Pu = 0.00464 ± 0.00007, and 242 Pu/ 239 Pu = 0.0157 ± 0.0001 (k = 2). These results closely align with the certificate values for CRM 136a and CRM 137 and are within the k = 2 envelopes defined by the long-term performance of the traditional MC-ICP-MS approach (Neptune Plus). Examination of the performance of the various Pu isotope ratios as a function of total Pu content revealed accurate results (<3% relative difference, or RD) above ∼50 fg total Pu. The results presented here demonstrate the capability of the MC-ICP-MS/MS making accurate and precise low level Pu isotopic measurements. While the intent of this work was not to investigate the functionality of the collision cell, the pre-mass filter was employed. Future studies are warranted to investigate the entire capability of the MC-ICP-MS/MS collision cell and pre-cell mass filter optimization for performing low level Pu isotope measurements, even in mixed matrix samples.

CRM↗

A source-synchronous filter for uncorrelated receiver traces from a swept-frequency seismic source

We have developed a novel algorithm to reduce noise in signals obtained from swept-frequency sources by removing out-of-band external noise sources and distortion caused from unwanted harmonics. The algorithm is designed to condition nonstationary signals for which traditional frequency-domain methods for removing noise have been less effective. The source synchronous filter (SSF) is a time-varying narrow band filter, which is synchronized with the frequency of the source signal at all times. Because the bandwidth of the filter needs to account for the source-to-receiver propagation delay and the sweep rate, SSF works best with slow sweep rates and moveout-adjusted waveforms to compensate for source-receiver delays. The SSF algorithm was applied to data collected during a field test at the University of California Santa Barbara’s Garner Valley downhole array site in Southern California. At the site, a 45 kN shaker was mounted on top of a one-story structure and swept from 0 to 10 Hz and back over 60 s (producing useful seismic waves greater than 1.6 Hz). The seismic data were captured with small accelerometer and geophone arrays and with a distributed acoustic sensing array, which is a fiber-optic-based technique for the monitoring of elastic waves. The result of the application of SSF on the field data is a set of undistorted and uncorrelated traces that can be used in different applications, such as measuring phase velocities of surface waves or applying convolution operations with the encoder source function to obtain traveltimes. Lastly, the results from the SSF were used with a visual phase alignment tool to facilitate developing dispersion curves and as a prefilter to improve the interpretation of the data.

58 GEOSCIENCES↗

An Improved Representation of Vegetative Filter Strips in SWAT

Abstract. Vegetative filter strips (VFS) are popular conservation practices installed at the edges of agricultural fields to reduce losses of pollutants from agricultural areas to receiving waterbodies. The recent interest in using VFS areas as multifunctional landscapes necessitates an improved depiction of VFS in simulation models. This study is aimed to enhance the physical representation of VFS in the Soil and Water Assessment Tool (SWAT) to improve the representation of ecohydrologic processes and land management practices in VFS areas. The proposed enhancement enables routing of water, sediment, and nutrients from the source area through the VFS area and makes the infiltrated water and nutrients available for filter crop uptake. The improvements are implemented in SWAT by modifying input files through Matlab scripts and by changing SWAT subroutines to enable routing. The model improvements are tested with three paired watershed studies with and without edge-of-field VFS in central Iowa. The improved model estimated 46% runoff reduction, 91% sediment reduction, 83% total phosphorus reduction, and 54% nitrate reduction with VFS, and these estimates closely matched the measured VFS reductions. The improved model was able to represent increased infiltration, soil moisture, and denitrification in the VFS area, along with accurately capturing crop yields in the source and VFS areas. Overall, the results indicate improved physical representation of VFS in SWAT. Keywords: Conservation measures, Flexible buffer strips, Multifunctional buffers, SWAT model, Vegetative filter strips.

Agriculture↗

High resolution on-chip optical filter array based on double subwavelength grating reflectors

An optical filter array consisting of vertical narrow-band Fabry-Pèrot (FP) resonators formed by two highly reflective high contrast subwavelength grating mirrors is reported. The filters are designed to cover a wide range of operation wavelengths ( Δλ/λ=5%) just by changing the in-plane grating parameters while the device thickness is maintained constant. In conclusion, operation in the telecom band with transmission efficiencies greater than 40% and quality factors greater than 1,000 are measured experimentally for filters fabricated on the same substrate.

36 MATERIALS SCIENCE↗

High laser fluence ITO coatings utilizing a Fabry-Perot thin film filter to reduce effective absorption

Laser-induced damage threshold of transparent conductors, such as Indium Tin Oxide (ITO), is limited by their high optical absorption due to free carriers. However, the effective absorption of a transparent conductor thin film can be reduced by an order of magnitude, without changing the electrical characteristics of the film, when placed in a low electric field section of a multilayer coating. A Fabry-Perot thin film interference filter has both high transmittance and low electric field positions, so it is an ideal thin film structure for this application. Although Fabry-Perot interference filters are not known as particularly high laser-induced damage resistant coatings due to their resonant characteristics, a laser-induced damage threshold (LIDT) improvement of up to 8× was observed with this technique compared to single layer ITO coatings fabricated using either radio frequency magnetron sputtering or electron-beam deposition. Additionally, an approximately 4× LIDT improvement for a Fabry-Perot interference filter has been observed by the addition of ITO into the multilayer structure.

47 OTHER INSTRUMENTATION↗

Penalized ensemble Kalman filters for high dimensional non-linear systems

The ensemble Kalman filter (EnKF) is a data assimilation technique that uses an ensemble of models, updated with data, to track the time evolution of a usually non-linear system. It does so by using an empirical approximation to the well-known Kalman filter. However, its performance can suffer when the ensemble size is smaller than the state space, as is often necessary for computationally burdensome models. This scenario means that the empirical estimate of the state covariance is not full rank and possibly quite noisy. To solve this problem in this high dimensional regime, we propose a computationally fast and easy to implement algorithm called the penalized ensemble Kalman filter (PEnKF). Under certain conditions, it can be theoretically proven that the PEnKF will be accurate (the estimation error will converge to zero) despite having fewer ensemble members than state dimensions. Further, as contrasted to localization methods, the proposed approach learns the covariance structure associated with the dynamical system. These theoretical results are supported with simulations of several non-linear and high dimensional systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calculating Probability Densities with Homotopy and Applications to Particle Filters

In this work, we explore a homotopy sampling procedure and its generalization, loosely based on importance sampling, known as annealed importance sampling. The procedure makes use of a known probability distribution to find, via homotopy, the unknown normalization of a target distribution, as well as samples of the target distribution. We propose a reformulation of the method that leads to a rejection sampling alternative. Estimates of the error as a function of homotopy stages and sample averages are derived for the algorithmic version of the method. These estimates are useful in making computational efficiency decisions on how the calculation should proceed, given a computer architecture. Consideration is given to how the procedure can be adapted to Bayesian stationary and nonstationary estimation problems. The connection between homotopy sampling and thermodynamic integration is made. Emphasis is placed on the non-stationary problems, and in particular, on a sequential estimation technique known as particle filtering. It is shown that a modification of the particle filter framework to include the homotopy process can improve the computational robustness of particle filters.

97 MATHEMATICS AND COMPUTING↗

Results for Actinide Removal Process 512-S Guard Filter Analyses

The Actinide Removal Process (ARP) removes Sr and actinides by adsorption to monosodium titanate (MST) from radioactive salt solutions that have been stored at the Savannah River Site (SRS). The MST solids are then removed by filtration. Material from the 512-S Late Wash Precipitate Tank (LWPT) is cross-flow filtered and the filtrate sent through a secondary filter (guard filter) to the Late Wash Hold Tank (LWHT) for further processing in the Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Aluminum Nitride Based MEMS IF Filter Array for Analog Spectral Processors

The purpose of this project was to enable new levels of performance in radio frequency systems, such as adaptability, size and stability, based on aluminum nitride microresonator technology. Early in the project, in 2008, Sandia developed arrays of filters for realizing high scan rate spectrum analyzers at 20 MHz and Rockwell Collins demonstrated a high scan rate spectrum analyzer leveraging this technology in 2009. The filter arrays, because of the transduction physics, demonstrated massively reduced size, loss and impedance compared to existing filter technologies. These device level benefits translated to reduced size and power for the spectrum analyzers at the system level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radio Frequency Sensing of Particulate Matter Accumulation on a Gasoline Particulate Filter

Filter Sensing Technology’s radio frequency (RF) sensor for particulate filter on-board diagnostics (OBD) was studied on a lean gasoline engine at the National Transportation Research Center (NTRC) at Oak Ridge National Laboratory (ORNL). The response of the RF sensor to particulate matter (PM) or “soot” accumulation on the gasoline particulate filter (GPF) installed in the engine exhaust was evaluated. In addition, end plugs of the GPF were purposely removed, and subsequent changes to the RF sensor measured soot loading on the GPF were characterized. Results from the study showed that the RF sensor can accurately measure soot accumulation on a GPF; furthermore, the predicted decreased soot accumulation due to plug removal was detected by the RF sensor. Overall, the studies were short and preliminary in nature; however, clearly, the RF sensor demonstrated the capability of measuring GPF soot loading at a level suitable for use in lean gasoline engine emission control OBD and control.

33 ADVANCED PROPULSION SYSTEMS↗

Unreviewed Disposal Question Evaluation: Disposal of the West Valley Demonstration Project Fuel Receiving and Storage Debris and Filters at the Area 5 Radioactive Waste Management Site, Nevada National Security Site, Nye County, Nevada

This Unreviewed Disposal Question Evaluation assesses whether the West Valley Demonstration Project (WVDP) Fuel Receiving and Storage (FRS) Debris and Filters waste stream is suitable for shallow land burial at the Area 5 Radioactive Waste Management Site on the Nevada National Security Site. Disposal of the WVDP FRS Debris and Filters low-level waste meets all DOE M 435.1-1 performance objectives. The WVDP FRS Debris and Filters waste stream is recommended for acceptance with the condition that the total 226Ra activity not exceed 2E9 Bq.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multichannel Deconvolution of Vibrational Shock Signals: An Inverse Filtering Approach

When transporting critical systems of national security interest, out-of-the ordinary, impulsive events that can potentially be undetected and affect overall system performance are of great concern. Impulsive events that can occur are essentially pulse-like, transient signals of short duration that evolve from various phenomena. Here the event can be created by either the dropping of a test object, the system, subjecting it to a compact high-energy blow or being struck unintentionally during transit resulting in potential damage. The intensity and location of the strike can cause an inoperability condition that is unacceptable in a national security environment. Therefore, it is essential to detect, classify and localize damage of any test object subjected to an impulsive-event. This effort was targeted to evaluate the vibrational response of test objects that are subjected to “transport” shocks and roadway vibrations during shipping and handling. Any potential damage that could be inflicted during transportation must not only be detected, but also be evaluated to determine the operational readiness of a test object before and after transport. This event is a critical task that must be addressed as part of the Lawrence Livermore National Laboratory (LLNL) national security mission. The estimation of excitation signals from noisy data is termed the deconvolution problem in the signal processing literature. The deconvolution problem is based on recovering the input excitation signal from a system characterized by its impulse response sequence. Using this model of the system, an “inverse” representation or filter is developed to remove the system from the measured data and recover the input. Deconvolution techniques have existed for a long-time; however, transient deconvolution presents a few uncommon problems, since the signal has a finite-length time duration resulting in a limited amount of data containing information about the excitation process. The transient is wideband in the frequency domain relative to any measurement sensor implying that the smaller bandwidth sensor system “filters” the excitation eliminating some of its essential information for recovery. This fact, coupled with the filtering effect of the test object itself makes this excitation recovery (deconvolution) problem a challenge for signal processing.

42 ENGINEERING↗

Quantitative form and fit of N95 filtering facepiece respirators are retained after dry and humid heat treatments for coronavirus deactivation

Re-use of filtering facepiece respirators (FFRs, commonly referred to as N95s) normally meant for single use only is becoming common in healthcare facilities due to shortages caused by the COVID19 pandemic. Here we report that mouse hepatitis virus (MHV) initially seeded on FFR filter material is inactivated (6 log reduction as measured by 50% tissue culture infective dose (TCID50)) after dry heating at 75 °C for 30 minutes. We also find that the quantitative fit of FFRs after heat treatment at this temperature, under dry conditions or at 90% relative humidity, is not affected by single or ten heating cycles. Previous studies have reported that the filtration efficiency of FFR filters is not negatively impacted by these heating conditions. These results suggest that thermal inactivation of coronaviruses is a potentially rapid and widely deployable method to re-use N95 FFRs in emergency situations where reusing FFRs is a necessity and broad-spectrum sterilization is unavailable. However, we also found that a heat source that emits radiation (e.g., an exposed heating element) results in rapid qualitative degradation of the FFR. Finally, we discuss differences in the results reported here and other recent studies investing heat as a means to recycle FFRs and suggest that overall wear time and donning/doffing cycles are important factors that need to be considered.

36 MATERIALS SCIENCE↗

Nuclear Canister Filter Test System UPC Plan

LANL has purchased “Hagan” canisters and “SAVY” canisters from NFT Inc (Golden CO). This document provides instruction for calibrating a LANL-designed FTS Filter Test System. The FTS device measures the amount of oil droplet aerosol captured in filters of nuclear material canisters at Los Alamos National Laboratory (LANL). The FTS device is intended to evaluate canister filters manufactured by NFT. The Los Alamos Standards and Calibration Lab (S&CL) does not support the calibration of aerosol generation or counting instrumentation. For operations inside the LANL TA-55 PF4 facility, the LANL FTS system could be potentially contaminated. LANL has constructed two (2) FTS devices, one in TA-55, the other in TA-3.

42 ENGINEERING↗

Assembly Operations Welding Filter(s) in Drum Calculation

This calculation documents the estimation of temperature and pressure rise inside a 55-gal TRU waste drum with a HEPA filter containing Titanium and Tantalum fume dust based on operational history. Actual Titanium values are believed to be less than 10g on any given filter. Actual Tantalum values are believed to be less than 1g on any given filter

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗