Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “field test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Water Recovery From Cooling Tower Plumes

According to studies by the UN and the US State Department, we are on the path to an extreme freshwater shortage by 2030. The US’s largest water withdrawal source is power plants, which account for 39% of total US freshwater withdrawals, mostly for cooling. Cooling towers are the most common cooling system. To solve these problems and enable efficient water- based cooling – Infinite Cooling’s novel technology uses electric fields to ionize the air, charge the escaping water leaving cooling towers and direct the water toward mesh collectors where it collects and gets recycled for use in the cooling system. This technology was developed at MIT and was reduced to practice on a lab-scale prototype, and a prototype at the MIT Cogeneration Power Plant. This DOE award funded taking this technology from a lab-scale prototype to TRL 5 on an operating cooling tower in the field at the MIT Nuclear Research Laboratory. The funding helped to design and optimize an electrostatic plume collection system and test it in high-fidelity lab setting and in actual field conditions on a cooling tower. Throughout the award, Infinite Cooling investigated the formation of plumes on cooling towers, used that information to optimize the design, material and electrical properties of the collection device and quantified the collection yield via flow rate and water quality.

20 FOSSIL-FUELED POWER PLANTS↗

V31 Test Report

The V31 containment vessel was procured by the US Army Recovered Chemical Materiel Directorate (RCMD) as a third-generation EDS containment vessel. It is the fifth EDS vessel to be fabricated under Code Case 2564 of the 2019 ASME Boiler and Pressure Vessel Code, which provides rules for the design of impulsively loaded vessels. The explosive rating for the vessel, based on the code case, is twenty-four (24) pounds TNT-equivalent for up to 1092 detonations. This report documents the results of explosive tests that were performed on the vessel at Sandia National Laboratories in Albuquerque, New Mexico to qualify the vessel for field operations use. There were three design basis configurations for qualification testing. Qualification test (1) consisted of a simulated M55 rocket motor and warhead assembly of 24lbs of Composition C-4 (30 lb TNT equivalent). This test was considered the maximum load case, based on modeling and simulation methods performed by Sandia prior to the vessel design phase. Qualification test (2) consisted of a regular, right circular cylinder, unitary charge, located central to the vessel interior of 19.2 lb of Composition C-4 (24 lb TNT equivalent). Qualification test (3) consisted of a 12-pack of regular, right circular cylinders of 2 lb each, distributed evenly inside the vessel (totaling 19.2 lb of C-4, or 24 lb TNT equivalent). All vessel acceptance criteria were met .

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Combined-Accelerated Stress Testing for Advanced Reliability Assessment of Photovoltaic Modules

New and previously undiscovered degradation mechanisms continue to be identified after field exposure in new photovoltaic module designs or materials oftentimes results in significant losses in investment. This is despite passing certification tests. Testing is insufficient largely due to their single-or double-stress nature. A Combined-Accelerated Stress Test (C-AST) has recently been developed. The test combines multiple stress factors of the natural environment to better replicate conditions experienced by modules in the field and detect mechanisms not a-priori known in new materials and designs.

accelerator factor modeling↗

HTS Dipole Magnet Model for the Persistent Current Operation

Recent advances in the fabrication of high-temperature superconducting (HTS) coils allow the design of superconducting accelerator magnets that work in a persistent current mode. Many various, rather low-field magnets in particle accelerators operate in the DC current mode. Fermilab designed, fabricated, and tested an HTS dipole magnet model that has 20-mm air gap and a magnetic field up to 0.5 T. The magnet has a primary copper coil that for a short period pumps the energy in the short-circuited secondary HTS coil. Here, the current paper presents the design, fabrication, and testing of this magnet at liquid-nitrogen temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advanced Diagnosis and Accelerated Testing of Balance of System Components for Utility Scale PV Installations: October 1, 2022-September 30, 2024

A study of the durability of PV Balance of System components was performed. Specifically, wire cable jackets and cable connectors were examined within the direct current (DC) PV Power Transmission Chain (PTC). Degraded and failed samples have been obtained from utility PV installations to provide feedback on the degradation modes and the related damage-enabling considerations in today's PV systems. An industry interface group (including system owners, system inspectors, component manufacturers, and test labs) was used to help identify and obtain field-failed samples, for feedback (including samples and experimental design), and to facilitate the subsequent dissemination of the results of this study. Samples were empirically studied using accelerated stress testing with steady-state conditions (cable jackets) in addition to combined-accelerated stress testing (cable jackets, connectors and uncapped connectors). Steady-state accelerated testing has been performed using at least one applied stressor (e.g. UV light) to aid understanding of jacket durability relative to its application. Component- and material-focused failure analysis was conducted to develop an understanding and advise the PV industry. In-depth characterization will be applied selectively to field- and artificially aged-samples, to gain scientific understanding of the structural, chemical, electrical, mechanical, and thermal properties enabling degradation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MDPCT1 Quench Data and Performance Analysis

MDPCT1 is a four-layer cos-theta Nb3Sn dipole demonstrator developed and tested at FNAL in the framework of the U.S. Magnet Development Program. The magnet reached record fields for accelerator magnets of 14.1 T at 4.5 K in the first test and 14.5 T at 1.9 K in the second test and then showed large degradation. While its inner coils performed exceptionally well with only two quenches up to 14.5 T and no evidence of degradation, the outer coils degraded over the course of testing. By adopting new measurement and analysis techniques at FNAL we are discussing in detail what happened. Both success and failure in our diagnostics are discussed. The evolution of techniques over the course of two tests (and three thermal cycles) shows the path to address challenges brought by the first four-layer magnet tested at FNAL. This paper presents the analysis of quench data along with diagnostic features and complementary measurements taken in support of the magnet performance analysis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

PV Lifetime Project (2021 NREL Annual Report)

DOE's PV Lifetime project was initiated in 2016 with the goal of accurately characterizing the early-life evolution of photovoltaic (PV) field performance. Different PV cell and module technologies result in different initial performance loss rates due to effects like light-induced degradation (LID) and light & elevated temperature-induced degradation (LeTID). To accurately characterize the initial field performance loss requires the use of high-accuracy indoor IV curve measurements at standard test conditions. Therefore, PV modules involved in this study are removed from the field once or twice per year and brought indoors for measurement. Current samples deployed and monitored in this way include Jinko Solar (2016), Trina Solar (2016), Hanwha Q-Cells (2017), Panasonic (2018), LG (2018), Canadian Solar (2018), Mission Solar (2019). More recently, modules from Sunpreme (2019), and LONGi (2020) have been deployed but not yet analyzed. Overall annual performance loss rates are as follows: our first modules to be deployed (Jinko and Trina) have annual median performance loss rate between -0.4%/yr and -0.9%/yr, mainly concentrated in the first year. The QCells mono-PERC and multi-PERC modules have an annual degradation rate of -0.76%/yr and -0.69%/yr respectively, also concentrated in the first year of operation. Panasonic and LG modules displayed negligible performance loss in the past two years, at 0.1%/yr and -0.0%/yr respectively. They also were the only modules with initial IV curve measurements consistently above the nameplate rating. Possibly relatedly, these are also the only two N-type silicon module types analyzed so far. Canadian Solar multi-PERC modules demonstrated a -1.3%/yr degradation rate which actually accelerated in the past year, so this will be a module type to monitor in future years. Mission Solar modules exhibited strong recoverable performance loss, consistent with LeTID susceptibility. (The same is true for the Jinko JKM260 module type). Annual performance loss actually showed improvement in time at +0.3%/yr after 2 years in the field, although the module initially was measured at 3% below nameplate rating. These modules could therefore be experiencing a form of post-LeTID recovery. Initial measurements have been conducted on the next two module types - Sunpreme n-HIT and LONGi bifacial mono-PERC. We will report on initial year-1 performance change for these modules in the next PV Lifetime annual report. For the remaining modules, an additional year of field exposure will provide greater certainty in annual degradation rates, particularly for those with degradation concentrated in the initial year of field deployment.

14 SOLAR ENERGY↗

Multiscale spatial analysis of fracture arrangement and pattern reconstruction using Ripley's K-function

This work presents novel multiscale spatial data analytics using Ripley's K-function, as a measure of spatial interaction, to study one-dimensional arrangement of fractures. Fracture spatial arrangements are classified into clustered, anticlustered, or indistinguishable from random by testing statistical significance of the calculated Ripley's K-function. Characterizations of fracture arrangements are performed as a function of length scale and position. Analysis of the K-function along the study interval identifies where fracture clustering and anticlustering occur. Here, a simulation technique is also introduced here to statistically reconstruct spatial arrangements and to generate fracture realizations that are spatially similar to the fractures observed in the field. With this simulation technique, one can also fill spatial gaps in fracture measurements where data are absent, unreliable, or unused. Synthetic as well as field-measured 1D fracture datasets are used for testing and demonstration. Methods introduced in this work can be readily applied to fracture datasets observed in outcrops, borehole image logs, and cores.

58 GEOSCIENCES↗

Gravitational effective field theory islands, low-spin dominance, and the four-graviton amplitude

Abstract We analyze constraints from perturbative unitarity and crossing on the leading contributions of higher-dimension operators to the four-graviton amplitude in four spacetime dimensions, including constraints that follow from distinct helicity configurations. We focus on the leading-order effect due to exchange by massive degrees of freedom which makes the amplitudes of interest infrared finite. In particular, we place a bound on the coefficient of the R 3 operator that corrects the graviton three-point amplitude in terms of the R 4 coefficient. To test the constraints we obtain nontrivial effective field-theory data by computing and taking the large-mass expansion of the one-loop minimally-coupled four-graviton amplitude with massive particles up to spin 2 circulating in the loop. Remarkably, we observe that the leading EFT coefficients obtained from both string and one-loop field-theory amplitudes lie in small islands. The shape and location of the islands can be derived from the dispersive representation for the Wilson coefficients using crossing and assuming that the lowest-spin spectral densities are the largest. Our analysis suggests that the Wilson coefficients of weakly-coupled gravitational physical theories are much more constrained than indicated by bounds arising from dispersive considerations of 2 → 2 scattering. The one-loop four-graviton amplitudes used to obtain the EFT data are computed using modern amplitude methods, including generalized unitarity, supersymmetric decompositions and the double copy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Criticality analysis of nuclear binding energy neural networks

Machine learning methods, in particular deep learning methods such as artificial neural networks (ANNs) with many layers, have become widespread and useful tools in nuclear physics. However, these ANNs are typically treated as ‘black boxes’, with their architecture (width, depth, and weight/bias initialization) and the training algorithm and parameters chosen empirically by optimizing learning based on limited exploration. We test a non-empirical approach to understanding and optimizing nuclear physics ANNs by adapting a criticality analysis based on renormalization group flows in terms of the hyperparameters for weight/bias initialization, training rates, and the ratio of depth to width. This treatment utilizes the statistical properties of neural network initialization to find a generating functional for network outputs at any layer, allowing for a path integral formulation of the ANN outputs as a Euclidean statistical field theory. We use a prototypical example to test the applicability of this approach: a simple ANN for nuclear binding energies. We find that with training using a stochastic gradient descent optimizer, the predicted criticality behavior is realized, and optimal performance is found with critical tuning. However, the use of an adaptive learning algorithm leads to somewhat superior results without concern for tuning and thus obscures the analysis. Nevertheless, the criticality analysis offers a way to look within the black box of ANNs, which is a first step towards potential improvements in network performance beyond using adaptive optimizers.

artificial neural network↗

GFiRe—Gauge Field integrator for Reheating

We present a new numerical algorithm and code, GFiRe, for solving the nonlinear evolution of Abelian gauge fields coupled to complex scalar fields in homogeneous and isotropic spacetimes. We adopt a hybrid approach to solving the system: the spatial derivatives are discretized using standard Lattice Gauge Field Theory techniques, whereas the time evolution of the fields and scale factor is implemented with explicit, composite, symplectic integrators. An important property of our compound algorithm is that the discretized Gauss constraint is respected exactly, regardless of the order of the symplectic integrator. This remains true even when the background expansion is computed “self-consistently”; that is, when the expansion history is computed using spatial averaged components of the energy momentum tensor in the simulation volume. Hence, our code can also be used in cases where the fields dominate the energy density of the universe, for example, during reheating after inflation. We test the algorithm in scenarios of reheating where the inflaton is a complex scalar field with a potential ∝(2|Φ| 2 - v 2 ) 2 and is coupled to an Abelian gauge field. Tracing the evolution of the system through complex dynamics (including resonant excitation of fields, backreaction, formation of solitons, and changes in the equation of state) in a self-consistently expanding universe, we find the energy conservation violation (<10 -4 ) to be very stable and the Gauss constraint violation (<10 -6 ) to be dominated by differencing noise.

79 ASTRONOMY AND ASTROPHYSICS↗

Heavy Oil Polymer EOR in the Challenging Alaskan Arctic - It Works!

Under co-sponsorship of the US Department of Energy and Hilcorp Alaska LLC the first ever polymer field pilot commenced on 8/28/2018 in the Schrader Bluff heavy oil reservoir at the Milne Point Field on Alaska North Slope (ANS). The primary objective of the pilot is to prove the efficacy of polymer Enhanced Oil Recovery (EOR) to unlock the vast heavy oil resources on ANS. More than two and half years after startup, the polymer injection, supporting laboratory experiments and simulation studies steadily continue. The pilot started injecting hydrolyzed polyacrylamide (HPAM), at a concentration of 1,750 ppm to achieve a target viscosity of 45 cP, into the two horizontal injectors in the flood pattern. Production is monitored in the two horizontal producers. Based on laboratory measurements of polymer viscosity at reservoir conditions, the team decided to reduce polymer concentration to 1,200 ppm since July 2020 in an effort to control injection pressure and optimize polymer utilization. Quality control (QC) on the field ensures uniform polymer solution properties. Representative rock and fluid systems and test conditions are utilized in the corefloods on polymer retention, effect of injection water salinity, polymer loading, and their combinations on oil recovery. A history matched reservoir simulation model for forecasting oil recovery was developed on the basis of all the available field data. Field concerns related to the post-polymer breakthrough impact on flow assurance is addressed via specialized laboratory tests. Notwithstanding early operational disruptions and hydration issues, continuous polymer injection in both injectors has been achieved. To date, 950,000 lbs of polymer or 2 million barrels of polymer solution, equating to 13% of total pore volume (PV), has been placed in the flood pattern, serving as an effective indicator of adequate polymer injectivity. So far, the success of polymer EOR is evident from drastically reduced water cut in the producers, an estimated incremental 1,000 bopd over waterflood, and a favorable polymer utilization of 1.7 lbs/barrel of incremental oil. Polymer breakthrough was observed 26 months after the start of polymer injection. Main observations from corefloods are unusually high polymer retention values in some cases and a positive response to low salinity water. Although the heterogeneity in the flood pattern and exceptionally low water cut pose some challenges, persistent novel and justifiable simulation approaches have resulted in a robust history matched model. Experimental results on produced fluids treatment provide operational guidance for improved oil-water separation and mitigation of heater tube fouling. The ongoing success of the pilot is a key indicator of bringing the team ever closer to meeting the project’s primary objective. The encouraging results of the pilot is one of the drivers that has provided the impetus to apply polymer EOR throughout the Milne Point Field, which would increase oil recovery and extend the economic life of the Trans Alaska Pipeline System. The scientific knowledge, including the many lessons learned from this pilot also has referential value for other potential heavy oil EOR projects throughout the world. The collected data, operational lessons learned, and the overall success of the pilot are summarized in the paper.

None, None↗

Characterization of flow and transport in a fracture network at the EGS Collab field experiment through stochastic modeling of tracer recovery

Energy extraction from subsurface reservoirs is important for addressing the increasing energy demand and environmental concerns such as global warming. However, the characterization of subsurface reservoirs, particularly reservoirs dominated by fracture networks remains a challenge due to the lack of means to directly observe subsurface processes. This study explores the feasibility and efficacy of characterizing fracture flow and transport processes in an enhanced geothermal system (EGS) testbed through stochastic tracer modeling. There are two enabling factors that allow application of stochastic modeling to characterize a subsurface reservoir. First, an abundance of geological and geophysical measurements enables the development of a high-fidelity and well-constrained fracture network model. Second, high-performance computing (HPC) allows running massive realizations efficiently. Six conservative tracer tests were stochastically modeled and produced satisfactory realizations that successfully reproduce field tracer recovery data from each tracer test. The evolution of flow and transport processes in the fracture network was then analyzed from these satisfactory realizations. This work demonstrates that stochastic tracer modeling on a high-fidelity fracture network model is feasible and can provide important insights regarding flow and transport characteristics in subsurface fractured reservoirs.

58 GEOSCIENCES↗

The magnetic gradient scale length explains why certain plasmas require close external magnetic coils

Abstract The separation between the last closed flux surface of a plasma and the external coils that magnetically confine it is a limiting factor in the construction of fusion-capable plasma devices. This plasma-coil separation must be large enough so that components such as a breeding blanket and neutron shielding can fit between the plasma and the coils. Plasma-coil separation affects reactor size, engineering complexity, and particle loss due to field ripple. For some plasmas it can be difficult to produce the desired flux surface shaping with distant coils, and for other plasmas it is infeasible altogether. Here, we seek to understand the underlying physics that limits plasma-coil separation and explain why some configurations require close external coils. In this paper, we explore the hypothesis that the limiting plasma-coil separation is set by the shortest scale length of the magnetic field as expressed by the ∇ B tensor. We tested this hypothesis on a database of > 40 stellarator and tokamak configurations. Within this database, the coil-to-plasma distance compared to the minor radius varies by over an order of magnitude. The magnetic scale length is well correlated to the coil-to-plasma distance of actual coil designs generated using the REGCOIL method (Landreman 2017 Nucl. Fusion 57 046003). Additionally, this correlation reveals a general trend that larger plasma-coil separation is possible with a small number of field periods.

Physics↗

Mean-Field Ring Polymer Rates Using a Population Dividing Surface

Mean-field Ring Polymer Molecular Dynamics (MF-RPMD) offers a computationally efficient method for the simulation of reaction rates in multi-level systems. Previous work has established that, to model a nonadiabatic state-to-state reaction accurately, the dividing surface must be chosen to explicitly sample kinked ring polymer configurations where at least one bead is in a different electronic state than the others. Building on this, we introduce a population difference coordinate and a kink-constrained dividing surface, and we test the accuracy of the resulting mean-field rate theory on a series of bilinear coupling model systems. Here, we demonstrate that this new MF-RPMD rate approach is efficient to implement and quantitatively accurate for models over a wide range of driving forces, coupling strengths, and temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Alkaline-SDS cell lysis of microbes with acetone protein precipitation for proteomic sample preparation in 96-well plate format

Plate-based proteomic sample preparation offers a solution to the large sample throughput demands in the biotechnology field where hundreds or thousands of engineered microbes are constructed for testing is routine. Meanwhile, sample preparation methods that work efficiently on broader microbial groups are desirable for new applications of proteomics in other fields, such as microbial communities. Here, we detail a step-by-step protocol that consists of cell lysis in an alkaline chemical buffer (NaOH/SDS) followed by protein precipitation with high-ionic strength acetone in 96-well format. The protocol works for a broad range of microbes ( e . g ., Gram-negative bacteria, Gram-positive bacteria, non-filamentous fungi) and the resulting proteins are ready for tryptic digestion for bottom-up quantitative proteomic analysis without the need for desalting column cleanup. The yield of protein using this protocol increases linearly with respect to the amount of starting biomass from 0.5–2.0 OD*mL of cells. By using a bench-top automated liquid dispenser, a cost-effective and environmentally-friendly option to eliminating pipette tips and reducing reagent waste, the protocol takes approximately 30 minutes to extract protein from 96 samples. Tests on mock mixtures showed expected results that the biomass composition structure is in close agreement with the experimental design. Lastly, we applied the protocol for the composition analysis of a synthetic community of environmental isolates grown on two different media. This protocol has been developed to facilitate rapid, low-variance sample preparation of hundreds of samples and allow flexibility for future protocol development.

59 BASIC BIOLOGICAL SCIENCES↗

Insights Into Seismicity Associated With Flexibly Operating Enhanced Geothermal System From Real‐Time Distributed Acoustic Sensing

Enhanced Geothermal Systems (EGS) have the capacity to broaden the accessible resource pool for geothermal power generation. Traditionally viewed as a “baseload” resource, their flexible operation might also enable dispatchable load‐following generation and long‐term energy storage, aligning them with the evolving landscape of decarbonized electricity systems. However, increasing permeability and extracting energy during EGS operations can induce microseismic events; for many prior EGS efforts, some associated seismicity has been observed. While energetically beneficial, the flexibility of EGS operations prompts our inquiry into whether new types of operations will yield previously unseen seismicity patterns. We demonstrate the use of distributed acoustic sensing (DAS) with real‐time edge computing to monitor seismicity during a pilot test of a cyclically operated EGS facility at the Blue Mountain geothermal field. Our focus lies in uncovering seismicity insights from the real‐time microseismic catalog, particularly during load‐following dispatchability tests simulating flexible EGS operation. Here, we find that variations in pore pressure consistently correlate with seismicity, and that controlling pressure cycles during flexible operations appears to constrain microseismic activity during subsequent cycles. The spatio‐temporal evolution of microseismic clouds recorded during cyclic injection cycles fits diffusive models over our available observation period. Additionally, seismicity elevation lags behind pore pressure increases, likely due to pressure diffusion to the fracture system boundary. Through real‐time monitoring, we offer novel insights into seismicity associated with flexibly operating EGS. Our findings suggest that leveraging DAS and edge computing can inform EGS operations and help mitigate induced seismicity.

Chamarczuk, Michal [Rice Univ., Houston, TX (Unite↗

Advancement of Commercial Intumescent Expanding Foams for Deactivation and Decommissioning in the Nuclear Sector - 20198

Florida International University (FIU), in collaboration with The Department of Energy's Office of Environmental Management (DOE-EM), Savannah River National Laboratory (SRNL), and sites across the Savannah River complex, have identified an operational requirement for a fixative technology that is intended to immobilize and/or isolate residual contamination within a 3-dimensional space. Fixation of radiological contamination can reduce worker risk and mitigate potentially hazardous conditions, however nearly every marketed contamination fixative has been found to be flammable; a significant concern in radiological facilities. Coupled with this, industry fixatives are normally used as a thin coating which can present problems when attempting to stabilize irregular geometry or areas that are difficult to access whilst ensuring full coverage. The technical evaluation and advancement of commercial-off-the-shelf (COTS) polyurethane foams has yielded a down-selected candidate that shows potential in meeting the requirements to support deactivation and decommissioning activities. Several performance criteria have been established and tested to progress the technology readiness level towards an active field demonstration (TRL-7). Such criteria include: mechanical failure limits, adhesive and cohesive properties, thermal/fire resilience, determining thermal behavior, ability to immobilize contamination, and a means of non-destructive evaluation of applications. The test scenario examined was targeted towards an application for decommissioning nuclear pipework, in which the down-selected polyurethane foam would act as a barrier to segregate pipework and mitigate the potential for release during cutting, packaging, and storage operations. Testing carried out at SRNL included: mechanical evaluation of tensile, compressive, and adhesion strength by dynamic mechanical analysis (DMA), as well as thermogravimetric analysis (TGA). FIU examined the foam's fixative properties by utilizing phosphorescent europium-dysprosium doped strontium aluminate powder to investigating the extent to which contamination can be immobilized. FIU has also exploited previous successes in the field of intumescent technologies to assess the down-selected foam's tolerance to an extreme fire scenario, while maintaining the ability to effectively mitigate a contamination release. Parallel to this, extensive thermal investigations were carried out to determine the upper boundary of anticipated heat generation during the curing process as heat generation has the potential to compromise rubber parts of contaminated enclosures. These investigations subsequently yielded a promising method for a non-destructive application evaluation by means of infrared thermography. Utilizing the high sensitivity of modern IR cameras, coupled with the heat generated during the curing process of the polyurethane foam, FIU has been exploring the concept of monitoring the external pipe surface for indications of an irregular or abnormal application, thus informing operational decision making. The testing carried out utilized several current 'best fit' ASTM standards, which serve as helpful guidelines for testing, however, a precise definition of the operational parameters and requirements is still necessary. With continued collaboration with SRNL, FIU aims refine said definitions and develop new standards by which this, and other decommissioning technologies, can be accredited by relevant standards based testing. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗