Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “faulting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Lessons Learned on Implementing Fault Detection, Isolation, and Recovery (FDIR) in a Ground Launch Environment

This paper's main purpose is to detail issues and lessons learned regarding designing, integrating, and implementing Fault Detection Isolation and Recovery (FDIR) for Constellation Exploration Program (CxP) Ground Operations at Kennedy Space Center (KSC). Part of the0 overall implementation of National Aeronautics and Space Administration's (NASA's) CxP, FDIR is being implemented in three main components of the program (Ares, Orion, and Ground Operations/Processing). While not initially part of the design baseline for the CxP Ground Operations, NASA felt that FDIR is important enough to develop, that NASA's Exploration Systems Mission Directorate's (ESMD's) Exploration Technology Development Program (ETDP) initiated a task for it under their Integrated System Health Management (ISHM) research area. This task, referred to as the FDIIR project, is a multi-year multi-center effort. The primary purpose of the FDIR project is to develop a prototype and pathway upon which Fault Detection and Isolation (FDI) may be transitioned into the Ground Operations baseline. Currently, Qualtech Systems Inc (QSI) Commercial Off The Shelf (COTS) software products Testability Engineering and Maintenance System (TEAMS) Designer and TEAMS RDS/RT are being utilized in the implementation of FDI within the FDIR project. The TEAMS Designer COTS software product is being utilized to model the system with Functional Fault Models (FFMs). A limited set of systems in Ground Operations are being modeled by the FDIR project, and the entire Ares Launch Vehicle is being modeled under the Functional Fault Analysis (FFA) project at Marshall Space Flight Center (MSFC). Integration of the Ares FFMs and the Ground Processing FFMs is being done under the FDIR project also utilizing the TEAMS Designer COTS software product. One of the most significant challenges related to integration is to ensure that FFMs developed by different organizations can be integrated easily and without errors. Software Interface Control Documents (ICDs) for the FFMs and their usage will be addressed as the solution to this issue. In particular, the advantages and disadvantages of these ICDs across physically separate development groups will be delineated.

Ferrell, Bob A.↗

NASA Space Flight Vehicle Fault Isolation Challenges

The Space Launch System (SLS) is the new NASA heavy lift launch vehicle and is scheduled for its first mission in 2017. The goal of the first mission, which will be uncrewed, is to demonstrate the integrated system performance of the SLS rocket and spacecraft before a crewed flight in 2021. SLS has many of the same logistics challenges as any other large scale program. Common logistics concerns for SLS include integration of discrete programs geographically separated, multiple prime contractors with distinct and different goals, schedule pressures and funding constraints. However, SLS also faces unique challenges. The new program is a confluence of new hardware and heritage, with heritage hardware constituting seventy-five percent of the program. This unique approach to design makes logistics concerns such as testability of the integrated flight vehicle especially problematic. The cost of fully automated diagnostics can be completely justified for a large fleet, but not so for a single flight vehicle. Fault detection is mandatory to assure the vehicle is capable of a safe launch, but fault isolation is another issue. SLS has considered various methods for fault isolation which can provide a reasonable balance between adequacy, timeliness and cost. This paper will address the analyses and decisions the NASA Logistics engineers are making to mitigate risk while providing a reasonable testability solution for fault isolation.

Bramon, Christopher↗

Segregation and Phase Transformations Along Superlattice Intrinsic Stacking Faults in Ni-Based Superalloys

In this study, local chemical and structural changes along superlattice intrinsic stacking faults combine to represent an atomic-scale phase transformation. In order to elicit stacking fault shear, creep tests of two different single crystal Ni-base superalloys, ME501 and CMSX-4, were performed near 750 degrees Centigrade using stresses of 552 megapascals and 750 megapascals, respectively. Through high resolution Scanning Transmission Electron Microscopy (STEM) and state-of-the-art energy dispersive x-ray spectroscopy, ordered compositional changes were measured along SISFs (Superlattice Intrinsic Stacking Faults) in both alloys. For both instances, the elemental segregation and local crystal structure present along the SISFs are consistent with a nanoscale to D019 (ordering of a hexagonal close-packed crystal) phase transformation. Another notable observation is prominent Cr- and Co-rich Cottrell atmospheres and new evidence of more complex reordering processes responsible for the formation of these faults. These findings are further supported using density functional theory calculations and High Angle Annular Dark Field (HAADF) STEM image simulations.

STEM-EDS↗

The Effect Stacking Fault Segregation and Phase Transformations have on Creep Strength in Ni-based Superalloys

In this study, two commercially similar polycrystalline Ni-based disk superalloys (LSHR and ME3) were creep tested at 760C and 552MPa to approximately 0.3% plastic strain. LSHR consistently displayed superior creep properties at this stress/temperature regime even though the microstructural characteristics between the two alloys were comparable. High resolution structural and chemical analysis, however, revealed significant differences between the two alloys among active gamma prime shearing modes involving superlattice intrinsic and extrinsic stacking faults. In ME3, Co and Cr segregation and Ni and Al depletion were observed along the intrinsic faults - revealing a gamma prime -to- gamma phase transformation. Conversely in LSHR, an alloy with a higher W content, Co and W segregation was observed along the intrinsic faults. This observation combined with scanning transmission electron microscopy (STEM) simulations confirm a gamma prime-to-D019 phase transformation along the intrinsic faults in LSHR. Using experimental observations and density functional theory calculations, a novel local phase transformation strengthening mechanism is proposed that could be further utilized to improve the high temperature creep capabilities of Ni-base disk alloys.

Superalloy↗

Novel concept for detection of a fluid flow fault in a pumped fluid heat rejection system

A pumped fluid heat rejection system (HRS) requires continuous flow of the working fluid to ensure that the components controlled by the HRS stay within their allowable temperature limits. An interruption of flow could result in violations of hardware qualification limits and mission failure. Some of these violations can happen within a few hours. Hence, quick detection of a flow fault to invoke mitigation measures is very critical. In typical pumped fluid HRS, dual or triple pumps are employed to switch the backup units in case the primary unit were to fail. The key metric for the selection of a fault detection system is that it should detect the fault much before the fault’s impact on the thermal health of the HRS controlled components is realized. A trade study was conducted to select such a system for the Europa Clipper Mission to Europa, a moon of Jupiter that is planned for a launch in 2023. Out of the several concepts studied, the most attractive one was a novel and simple concept that uses a low power film heater attached to a section of the HRS tubing. While the fluid flows at its nominal rate, the high thermal coupling of the flowing fluid leads to the tube being close to the fluid’s temperature. However, when the flow stops, the heater warms the small thermal mass of the tubing to a high temperature in a short span of time (~15 minutes). This large temperature rise would then imply that the flow must have stopped. This paper will describe the various concepts considered, the chosen concept, its implementation, and the results of developments tests to validate its performance.

Schmidt, Tyler↗

Stress Promotion of the 1958 Mw∼7.8 Fairweather Fault Earthquake and Others in Southeast Alaska by Glacial Isostatic Adjustment and Inter-earthquake Stress Transfer

We assess how recent glacial isostatic adjustment (GIA) and inter-earthquake stress transfer modulated the state of stress on major faults in Southeast Alaska, and how these effects may have influenced recent large and moderate earthquakes. The Glacier Bay Icefield has lost >3,000 km3 of ice since ca. 1770, with ice thinning up to 1.5 km, and the rest of southeast Alaska has been deglaciating since ca. 1900. The resulting GIA response in the solid earth produces present-day surface uplift rates of up to ∼4 cm/yr, among the fastest on Earth. This rapid deformation occurs directly alongside and atop the Fairweather Fault, which accommodates 4–5 cm/yr of right-lateral motion through slip in frequent large earthquakes, recently including a Mw∼7.8 earthquake in 1958. We find that the 1958 earthquake nucleated very close to the location of maximum GIA-induced Coulomb stress increase on the Fairweather Fault between 1770 and 1958 (estimated at ∼0.2–0.6 MPa), on the only section of fault where GIA-induced stress changes had involved both right-lateral shearing and unclamping. The September 10, 1899 Mw∼8.1 Yakutat Bay earthquake also promoted failure on at least the northwest part of the eventual 1958 rupture. In turn, the 1899 and 1958 earthquakes and GIA promoted failure along the St. Elias compressional margin, the site of a Mw∼7.4 event in 1979. While rapid tectonic loading is very likely the main driver of earthquakes in southeast Alaska, we estimate that 23 of 30 instrumentally constrained Mw ≥ 5.0 earthquakes in this region were also promoted by post-1770 GIA.

Chris Rollins↗

Reliability Models and Demonstration of a Fault-Tolerant Motor Concept for Vertical Takeoff and Landing Vehicles

This report documents the completion of the Revolutionary Vertical Lift Technology Project Annual Performance Indicator 24-3.2.4.1: “Apply and document reliability prediction for high reliability motor concept.” Two modeling tools were completed for calculation of reliability of fault-tolerant (FT) motors, and key FT operations of a modular FT motor were demonstrated experimentally. The two models are complementary tools for the stakeholder and user community. Both models employ Markov chain theory. The first model is a time-homogeneous Markov chain model, and the second is a time-inhomogeneous Markov-Weibull model. This report’s main sections are as follows: 1.0 Introduction, 2.0 Theory, 3.0 Motor Reliability Models, 4.0 Validation of FT Operation by Hardware Demonstration, and 5.0 Concluding Remarks. Novel contributions to the field include development of a modular FT motor concept for electrified vertical takeoff and landing (eVTOL) application, solution methods to solve the reliability calculations, development of figures of merit, and the introduction of “linked chains” to formulate a building-block approach for time-inhomogeneous Markov-Weibull modeling of motor reliability. Example case studies have been completed, and results are provided and discussed herein. A four-module FT motor concept was developed to a preliminary-design level of detail. This eVTOL FT motor concept was designed for galvanic, magnetic, and thermal isolation of stator winding faults. The reliability of the concept motor was calculated using a time-inhomogeneous Markov chain model. Employing average failure rate as a metric, 570 times greater reliability was achieved as compared to a baseline motor without fault tolerance. A demonstrator motor was built and tested. The testing demonstrated the key features of FT operation and validated the essential premises of the FT motor concepts presented herein. The experiments included successful demonstration of the feasibility of the following four key FT features: (1) terminal open-circuit operation, (2) thermal isolation after fault, (3) terminal short-circuit operation, and (4) internal short-circuit operation. These works indicate that FT modular motor drives offer promise for addressing the daunting reliability gap that electric aircraft propulsor drives are facing relative to the best conventional motor drive technology that is available today.

Electric Motor↗

Strategies for Fault Tolerance in Multicomponent Applications

This paper discusses on-going work with the Integrated Plasma Simulator (IPS), a framework for coupled multiphysics simulations of plasmas, to allow simulations to run through the loss of nodes on which the simulation is executing. While many different techniques are available to improve the fault tolerance of computational science applications on high-performance computer systems, checkpoint/restart (C/R) remains virtually the only one that see widespread use in practice. Our focus here is to augment the traditional C/R approach with additional techniques that can provide a more localized and tailored response to faults based on the ability to restart failed tasks on an individual basis, and the use of information external to the application itself in order to guide decision-making, in many cases avoiding the need to stop and restart the entire simulation. This capability involves several features within the IPS framework, and leverages the Fault Tolerance Backplane, a publish/subscribe event service to disseminate fault-related information throughout HPC systems, to obtain information from the Reliability, Availability and Serviceability (RAS) subsystem of the HPC system. This work is described in the context of Cray XT-series computer systems for concreteness, but is applicable to other environments as well. As part of the analysis of this work, we discuss the requirements to generalize this approach to other complex simulation applications beyond the Integrated Plasma Simulator.

99 GENERAL AND MISCELLANEOUS↗

Building a Fault Tolerant MPI Application: A Ring Communication Example

Process failure is projected to become a normal event for many long running and scalable High Performance Computing (HPC) applications. As such many application developers are investigating Algorithm Based Fault Tolerance (ABFT) techniques to improve the efficiency of application recovery beyond what existing checkpoint/restart techniques alone can provide. Unfortunately for these application developers the libraries that their applications depend upon, like Message Passing Interface (MPI), do not have standardized fault tolerance semantics. This paper introduces the reader to a set of run-through stabilization semantics being developed by the MPI Forum's Fault Tolerance Working Group to support ABFT. Using a well-known ring communication program as the running example, this paper illustrates to application developers new to ABFT some of the issues that arise when designing a fault tolerant application. The ring program allows the paper to focus on the communication-level issues rather than the data preservation mechanisms covered by existing literature. This paper highlights a common set of issues that application developers must address in their design including program control management, duplicate message detection, termination detection, and testing. The discussion provides application developers new to ABFT with an introduction to both new interfaces becoming available, and a range of design issues that they will likely need to address regardless of their research domain.

99 GENERAL AND MISCELLANEOUS↗

OpenStudio - Fault Modeling

This software record documents the OpenStudio fault model development portion of the Fault Detection and Diagnostics LDRD project.The software provides a suite of OpenStudio measures (scripts) for modeling typical HVAC system faults in commercial buildings and also included supporting materials: example projects and OpenStudio measures for reporting fault costs and energy impacts.

Frank, Stephen↗

Wide area fault detection method using PMU data

The embodiments herein are directed to monitoring in real time, power system data so as to provide insights into global operation of a power grid. Such a scheme disclosed herein utilizes rules, which are created by analyzing PMU measurement data, in order to detect the fault location (bus and line) and fault type. Three common types of faults in a power grid, single-line-to-ground (SLG), line-to-line (LL), and three phase faults, can be detected using the methods herein.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integral light sources and detectors for an optical sensor to detect battery faults

Light is transmitted from a light source through or from a separator of a battery cell and received by one or more light detectors. The light that is normally transmitted through the separator is scattered, absorbed, wavelength-shifted or otherwise distorted by an impending fault in the vicinity of or within the separator. The change in light due to the impending fault is measured by a detector and a signal from the detector is processed to identify the impending fault so that a warning can be generated indicative of the impending fault. In particular, one or both of the light source and detector are enclosed within a battery cell housing.

36 MATERIALS SCIENCE↗

Optical waveguide methods for detecting internal faults in operating batteries

Light is transmitted from a light source through or from a separator of a battery cell and received by one or more light detectors. The light that is normally transmitted through the separator is scattered, absorbed, wavelength-shifted or otherwise distorted by an impending fault in the vicinity of or within the separator. The change in light due to the impending fault is measured by a detector and a signal from the detector is processed to identify the impending fault so that a warning can be generated indicative of the impending fault. In particular, the separator and a battery cell electrolyte can be selected to provide waveguide properties.

Saunders, James H.↗

Characterizing natural fractures and sub-seismic faults for well completion of Marcellus shale in the MSEEL Consortium project, West Virginia, USA

The Middle Devonian Marcellus shale play has emerged as a major world-class hydrocarbon accumulation and represents one of the largest and most prolific shale plays in the world. According to many outcrop studies in the region, natural fractures are well developed in the Marcellus Shale. However, evaluating fractures in the subsurface is often a significant challenge due to a lack of sufficient data. Therefore, in the Marcellus Shale Energy and Environment Laboratory (MSEEL) consortium project, significant efforts have been made to acquire high-quality image logs in the Marcellus laterals. The project provided tremendous opportunities to characterize the natural fractures and sub-seismic faults and to evaluate their impact on well stimulation. In this study, about 70,000 ft of acquired high-resolution logging while drilling (LWD) acoustic images from five long laterals located in Monongalia County, West Virginia, were processed and interpreted. In addition, the study used high-quality micro-resistivity images from a pilot well, allowing the evaluation of natural fractures in the entire Marcellus vertical sequence. Based on the available acoustic images, the natural fractures were classified into three basic categories: high-amplitude fractures, low-amplitude fractures, and faults. Further, larger open fractures can also be determined when a low-amplitude fracture is evident on caliper images. The fractures in the Marcellus usually have a medium to high angle dip; however, multiple fracture sets in terms of strike orientation were clearly observed in all the laterals. The fracture set with a strike at NE-SW (or 60-240 deg) seems to be the predominant one in all the wells. A few other sets, including those with N-S, NWW-SEE, and E-W strikes, were also observed. Several sub-seismic faults, with mostly a low dip angle and a NE-SW strike, have also been seen in two of the laterals. The fracture density is variable across all the laterals, ranging from very low (or none) to very high (up to 5 fractures per ft). The average fracture density for all the laterals is about 1 fracture per 10 ft. In the vertical sequence, the natural fracture development showed a clear preference for shale or shaly facies over carbonate-rich or thin limestone layers. The interpreted fracture and fault data were used as input data for the stimulation design with the purpose of better understanding the fractures’ impact on well stimulation. Production data from the laterals were also used to evaluate the natural fractures’ influence on well performance. The quality image database and the consistent interpretation results for the entire project enabled a systematic approach to characterizing fractures and, more importantly, to evaluating the impact of fractures on well stimulation and production.

03 NATURAL GAS↗

CEBAF C100 Fault Classification based on Time Domain RF Signals

The CEBAF 12 GeV upgrade project, which was completed and commissioned in 2014, included the construction and installation of 80 new 7-cell superconducting cavities that were configured in 10 cryomodules. In 2018, the software and hardware in the digital low level RF systems were configured such that a fault would trigger an acquisition process which records waveform records of 17 of the RF signals for each of the 8 cavities within the cryomodule for subsequent analysis. These waveforms are especially useful in C100 cryomodules as there is a 10% mechanical coupling between adjacent cavities. When one cavity has a fault and the gradient is reduced quickly, it will mechanically deform due relaxation of the Lorentz force effects. This deformation change causes perturbations in the adjacent cavities which, in turn, causes a cascade of cavity faults that are difficult to understand without the time domain data. This contribution will describe the types of faults encountered during operation and their signatures in the time domain data, as well as how is being used to modify the setup of the machine and implement improvements to the cryomodules.

Powers, T.↗

Fault Characterization and Diagnostics Supporting Condition-Based Operation and Maintenance of Gas Turbine Engines

Condition-Based Operation and Maintenance (CBOM) is the state-of-the-art in maintenance approaches for gas turbine engines. CBOM applies engine sensor information to the optimization of future operation and maintenance procedures; this technique reduces costs for engine operators by minimizing unplanned outages and catastrophic engine degradation. However, due to the complexities of gas turbine operation and the lack of available engine sensors, further development is required to fully realize the benefits of CBOM. In the turbine section, rotating components interact with high temperature flows, which creates intense thermal and mechanical stresses. As a result, there are numerous mechanisms of component degradation in the turbine section. Furthermore, turbine components – like stator vanes and rotor blades – are among the most expensive in the engine because they are complex to design and manufacture. For these reasons, this dissertation addresses two main questions: (i) which parameters or faults within the turbine section are most important to monitor, and (ii) how can these parameters or faults be monitored in an engine-relevant environment? Although many turbine parameters and faults have been investigated in the open literature, there are some faults that are still not well understood. Rotor-casing eccentricity, which causes a non-constant blade tip clearance around the annulus, has not been investigated in terms of its effects on turbine efficiency. Therefore, the first study in this dissertation quantifies overall and local turbine efficiency for varying levels of rotor-casing eccentricity. Results showed negligible variations to overall turbine efficiency, meaning rotor-casing eccentricity only becomes relevant to CBOM when its severity causes rotordynamic issues. Purge flow is critical to turbine hardware longevity because it prevents ingestion of hot main gas path (MGP) flow into the under-platform regions. Despite its importance, there are currently no methods for monitoring purge flow performance in an engine environment. Therefore, the second study in this dissertation develops a predictive model for sealing effectiveness using inputs from two fast-response pressure sensors. Results exhibited low prediction errors across a full range of purge flow rates, which supports the viability of the modelling approach for CBOM. The final two studies in this dissertation address blade coolant flow monitoring. This cooling flow is responsible for protecting the turbine blades from the MGP flow, which exits the combustor at temperatures greater than the blade melting point. These studies showed that temperature measurements on the blade surface can be used to accurately predict blade coolant flow rate, and that defining the candidate features relative to the coolant trajectory is important for maintaining accuracy as coolant flow rate degradation occurs. This work enables blade coolant flow monitoring, which is currently not possible through existing condition monitoring techniques.

condition-based, gas turbines, diagnostics,↗

Assessing the Impact of Variable Air Volume Box Damper Stuck Faults Using a Building Automation System and Building Energy Simulation Model

The study examines the impact of variable air volume (VAV) damper stuck faults on the system operation, building indoor conditions, and reheating energy consumption. This study includes both experimental and simulation studies for five test scenarios, including a fault-free scenario. We implemented VAV damper stuck fault through the building automation system (BAS). Results show that a damper stuck in a high opening position (60% damper opening) results in supplying an excessive amount of cold air from the rooftop unit (RTU) to the conditioned zone, increasing reheating energy consumption. The results of this research can serve as a foundational resource for developing fault detection algorithms.

Jung, Sungkyun↗

Ground-Motion Simulations of Scenario Earthquakes on the Hayward Fault

We compute ground motions in the San Francisco Bay area for 35 Mw 6.7-7.2 scenario earthquake ruptures involving the Hayward fault. The modeled scenarios vary in rupture length, hypocenter, slip distribution, rupture speed, and rise time. This collaborative effort involves five modeling groups, using different wave propagation codes and domains of various sizes and resolutions, computing long-period (T > 1-2 s) or broadband (T > 0.1 s) synthetic ground motions for overlapping subsets of the suite of scenarios. The simulations incorporate 3-D geologic structure and illustrate the dramatic increase in intensity of shaking for Mw 7.05 ruptures of the entire Hayward fault compared with Mw 6.76 ruptures of the southern two-thirds of the fault. The area subjected to shaking stronger than MMI VII increases from about 10% of the San Francisco Bay urban area in the Mw 6.76 events to more than 40% of the urban area for the Mw 7.05 events. Similarly, combined rupture of the Hayward and Rodgers Creek faults in a Mw 7.2 event extends shaking stronger than MMI VII to nearly 50% of the urban area. For a given rupture length, the synthetic ground motions exhibit the greatest sensitivity to the slip distribution and location inside or near the edge of sedimentary basins. The hypocenter also exerts a strong influence on the amplitude of the shaking due to rupture directivity. The synthetic waveforms exhibit a weaker sensitivity to the rupture speed and are relatively insensitive to the rise time. The ground motions from the simulations are generally consistent with Next Generation Attenuation ground-motion prediction models but contain long-period effects, such as rupture directivity and amplification in shallow sedimentary basins that are not fully captured by the ground-motion prediction models.

58 GEOSCIENCES↗