Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

J/ψ production at midrapidity in p-Pb collisions at $ \sqrt{s_{\textrm{NN}}}$ = 8.16 TeV

The production of inclusive, prompt and non-prompt J/ψ was studied for the first time at midrapidity (–1.37 < y cms < 0.43) in p-Pb collisions at $\sqrt{s_{NN}}$ = 8.16 TeV with the ALICE detector at the LHC. The inclusive J/ψ mesons were reconstructed in the dielectron decay channel in the transverse momentum (p T ) interval 0 < p T < 14 GeV/c and the prompt and non-prompt contributions were separated on a statistical basis for p T > 2 GeV/c. The study of the J/ψ mesons in the dielectron channel used for the first time in ALICE online single-electron triggers from the Transition Radiation Detector, providing a data sample corresponding to an integrated luminosity of 689 ± 13 μb –1 . The proton-proton reference cross section for inclusive J/ψ was obtained based on interpolations of measured data at different centre-of-mass energies and a universal function describing the p T -differential J/ψ production cross sections. The p T -differential nuclear modification factors R pPb of inclusive, prompt, and non-prompt J/ψ are consistent with unity and described by theoretical models implementing only nuclear shadowing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved particle-flow event reconstruction with scalable neural networks for current and future particle detectors

Abstract Efficient and accurate algorithms are necessary to reconstruct particles in the highly granular detectors anticipated at the High-Luminosity Large Hadron Collider and the Future Circular Collider. We study scalable machine learning models for event reconstruction in electron-positron collisions based on a full detector simulation. Particle-flow reconstruction can be formulated as a supervised learning task using tracks and calorimeter clusters. We compare a graph neural network and kernel-based transformer and demonstrate that we can avoid quadratic operations while achieving realistic reconstruction. We show that hyperparameter tuning significantly improves the performance of the models. The best graph neural network model shows improvement in the jet transverse momentum resolution by up to 50% compared to the rule-based algorithm. The resulting model is portable across Nvidia, AMD and Habana hardware. Accurate and fast machine-learning based reconstruction can significantly improve future measurements at colliders.

Physics↗

Single particle detection system for strong-field QED experiments

Abstract Measuring signatures of strong-field quantum electrodynamics (SF-QED) processes in an intense laser field is an experimental challenge: it requires detectors to be highly sensitive to single electrons and positrons in the presence of the typically very strong x-ray and γ -photon background levels. In this paper, we describe a particle detector capable of diagnosing single leptons from SF-QED interactions and discuss the background level simulations for the upcoming Experiment-320 at FACET-II (SLAC National Accelerator Laboratory). The single particle detection system described here combines pixelated scintillation LYSO screens and a Cherenkov calorimeter. We detail the performance of the system using simulations and a calibration of the Cherenkov detector at the ELBE accelerator. Single 3 GeV leptons are expected to produce approximately 537 detectable photons in a single calorimeter channel. This signal is compared to Monte-Carlo simulations of the experiment. A signal-to-noise ratio of 18 in a single Cherenkov calorimeter detector is expected and a spectral resolution of 2% is achieved using the pixelated LYSO screens.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Introducing a Markov chain-based time calibration procedure for multi-channel particle detectors: application to the SuperFGD and ToF detectors of the T2K experiment

Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed must be able to efficiently correct for minimal mis-synchronisation between channels and achieve the best detector performance. We present an iterative time calibration method based on Markov Chains, suitable for detector systems with multiple readout channels. Starting from correlated hit pairs alone, and without requiring an external reference time measurement, the method solves for fixed per-channel offsets, with precision limited only by the intrinsic single-channel resolution. A mathematical proof that the method is able to find the correct time offsets to be assigned to each detector channel in order to achieve inter-channel synchronisation is given, and it is shown that the number of iterations to reach convergence within the desired precision is controllable with a single parameter. Numerical studies are used to confirm unbiased recovery of true offsets. Finally, the application of the calibration method to the Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF) detector at the upgraded T2K near detector (ND280) shows good improvement in overall timing resolution, demonstrating the effectiveness in a real-world scenario and scalability.

calibration and fitting methods↗

Radiation damage effects on solid state detectors

Totally depleted silicon diodes are discussed which are used as nuclear particle detectors in investigations of galactic and solar cosmic radiation and trapped radiation. A study of radiation and chemical effects on the diodes was conducted. Work on electron and proton irradiation of surface barrier detectors with thicknesses up to 1 mm was completed, and work on lithium-drifted silicon devices with thicknesses of several millimeters was begun.

Trainor, J. H.↗

Energy response characterization of current-mode MeV Cherenkov aerogel detectors

Current-mode Cherenkov aerogel detectors have been used to measure time resolved spectra of MeV radiographic x-ray sources and have been considered to replace gas Cherenkov systems. The simulations of the Cherenkov response of aerogel detectors have uncertainties in how to model the complex structure of aerogels. Data from three sites—the Idaho electron beam, the Los Alamos Site electron beam and microtron sources at Los Alamos—have been used to calibrate the relative energy response of 15 aerogels, varying in density from 10 to 430 mg/cm 3 , from incident electrons with energies from 1 to 12 MeV. Detector simulations need to introduce density variation in the aerogels to match the collected data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the Weak Mixing Angle in the DUNE near-Detector Complex

The planned DUNE experiment will have excellent sensitivity to the vector and axial couplings of the electron to the $Z$-boson via precision measurements of neutrino--electron scattering. We investigate the sensitivity of DUNE-PRISM, a movable near detector in the direction perpendicular to the beam line, and find that it will qualitatively impact our ability to constrain the weak couplings of the electron. We translate these neutrino--electron scattering measurements into a determination of the weak mixing angle at low scales and estimate that, with seven years of data taking, the DUNE near-detector can be used to measure $\sin^2\theta_W$ with better than 2% precision. We also discuss the impact of combining neutrino--electron scattering data with neutrino trident production at DUNE-PRISM.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reliable Transport over SpaceWire for James Webb Space Telescope (JWST) Focal Plane Electronics (FPE) Network

NASA's James Webb Space Telescope (JWST) faces difficult technical and budgetary challenges to overcome before it is scheduled launch in 2010. The Integrated Science Instrument Module (ISIM), shares these challenges. The major challenge addressed in this paper is the data network used to collect, process, compresses and store Infrared data. A total of 114 Mbps of raw information must be collected from 19 sources and delivered to the two redundant data processing units across a twenty meter deployed thermally restricted interface. Further data must be transferred to the solid-state recorder and the spacecraft. The JWST detectors are kept at cryogenic temperatures to obtain the sensitivity necessary to measure faint energy sources. The Focal Plane Electronics (FPE) that sample the detector, generate packets from the samples, and transmit these packets to the processing electronics must dissipate little power in order to help keep the detectors at these cold temperatures. Separating the low powered front-end electronics from the higher-powered processing electronics, and using a simple high-speed protocol to transmit the detector data minimize the power dissipation near the detectors. Low Voltage Differential Signaling (LVDS) drivers were considered an obvious choice for physical layer because of their high speed and low power. The mechanical restriction on the number cables across the thermal interface force the Image packets to be concentrated upon two high-speed links. These links connect the many image packet sources, Focal Plane Electronics (FPE), located near the cryogenic detectors to the processing electronics on the spacecraft structure. From 12 to 10,000 seconds of raw data are processed to make up an image, various algorithms integrate the pixel data Loss of commands to configure the detectors as well as the loss of science data itself may cause inefficiency in the use of the telescope that are unacceptable given the high cost of the observatory. This combination of requirements necessitates a redundant, fault tolerant, high- speed, low mass, low power network with a low Bit error Rate(1E-9- 1E-12). The ISIM systems team performed many studies of the various network architectures that meeting these requirements. The architecture selected uses the Spacewire protocol, with the addition of a new transport and network layer added to implement end-to-end reliable transport. The network and reliable transport mechanism must be implemented in hardware because of the high average information rate and the restriction on the ability of the detectors to buffer data due to power and size restrictions. This network and transport mechanism was designed to be compatible with existing Spacewire links and routers so that existing equipment and designs may be leveraged upon. The transport layer specification is being coordinated with European Space Agency (ESA), Spacewire Working Group and the Consultative Committee for Space Data System (CCSDS) PlK Standard Onboard Interface (SOIF) panel, with the intent of developing a standard for reliable transport for Spacewire. Changes to the protocol presented are likely since negotiations are ongoing with these groups. A block of RTL VHDL that implements a multi-port Spacewire router with an external user interface will be developed and integrated with an existing Spacewire Link design. The external user interface will be the local interface that sources and sinks packets onto and off of the network (Figure 3). The external user interface implements the network and transport layer and handles acknowledgements and re-tries of packets for reliable transport over the network. Because the design is written in RTL, it may be ported to any technology but will initially be targeted to the new Actel Accelerator series (AX) part. Each link will run at 160 Mbps and the power will be about 0.165 Watt per link worst case in the Actel AX.

Rakow, Glenn↗

Development of mercuric iodide uncooled x ray detectors and spectrometers

The results obtained in the development of miniature, lowpower, light weight mercuric iodide, HgI2, x ray spectrometers for future space missions are summarized. It was demonstrated that HgI2 detectors can be employed in a high resolution x ray spectrometer, operating in a scanning electron microscope. Also, the development of HgI2 x ray detectors to augment alpha backscattering spectrometers is discussed. These combination instruments allow for the identification of all chemical elements, with the possible exception of hydrogen, and their respective concentrations. Additionally, further investigations of questions regarding radiation damage effects in the HgI2 x ray detectors are reported.

Iwanczyk, Jan S.↗

Measuring the Muon Neutrino Magnetic Moment in the NOvA Near Detector

Measuring an enhanced neutrino magnetic moment would be a clear indication of physics beyond the Standard Model, shedding light on the correct beyond Standard Model theory or the potential Majorana nature of neutrinos. It would manifest in the NOvA near detector as an excess of neutrino-on-electron elastic scattering interactions at low electron recoil energies. Leveraging an intense and highly pure muon neutrino beam, along with a finely segmented liquid scintillator detector technology specifically designed for electromagnetic shower separation, enables NOvA to achieve a potentially world-leading sensitivity in probing the effective muon neutrino magnetic moment. This analysis, based on neutrino data collected between 2014 and 2021, corresponding to an exposure of $13.8\times10^{20}$ protons-on-target, yields a result consistent with the Standard Model-only hypothesis with a p-value of 0.31. An upper limit on the effective muon neutrino magnetic moment is set at $\mu_{\nu_\mu}<19.1\times 10^{-10}\mu_B$ at $90\%$ confidence level. Despite facing statistical limitations stemming from low cross section of the signal process, systematic uncertainties have a significant impact on this result. To address these challenges, the NOvA Test Beam experiment focuses on mitigating some of the largest systematic uncertainties within NOvA by investigating particle interactions and energy deposition in a small-scale replica NOvA detector. This thesis describes the calibration of the NOvA Test Beam detector, which is a crucial step in analysing the Test Beam data before they can be utilised to reduce NOvA systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Processings of the Workshop on Electron Contamination in X-Ray Astronomy Experiments

The proceedings of a conference to investigate the effects of extraterrestrial radiation and particle contamination of X-ray astronomical data are presented. The subjects discussed include the following: (1) electrons at low altitudes which affect soft X-ray astronomy, (2) the geographical distribution of 100 keV electrons above the earth's atmosphere, (3) midlatitude electron precipitation, (4) particle background observed by X-ray detectors on board Copernicus satellite, and (5) a survey of trapped low energy electrons near the inner boundary of the inner radiation zone as determined by OSO-7.

Holt, S. S.↗

Mechanical Design and Development of TES Bolometer Detector Arrays for the Advanced ACTPol Experiment

The next generation Advanced ACTPol (AdvACT) experiment is currently underway and will consist of four Transition Edge Sensor (TES) bolometer arrays, with three operating together, totaling 5800 detectors on the sky. Building on experience gained with the ACTPol detector arrays, AdvACT will utilize various new technologies, including 150 mm detector wafers equipped with multichroic pixels, allowing for a more densely packed focal plane. Each set of detectors includes a feedhorn array of stacked silicon wafers which form a spline pro le leading to each pixel. This is then followed by a waveguide interface plate, detector wafer, back short cavity plate, and backshort cap. Each array is housed in a custom designed structure manufactured from high purity copper and then gold plated. In addition to the detector array assembly, the array package also encloses cryogenic readout electronics. We present the full mechanical design of the AdvACT high frequency (HF) detector array package along with a detailed look at the detector array stack assemblies. This experiment will also make use of extensive hardware and software previously developed for ACT, which will be modi ed to incorporate the new AdvACT instruments. Therefore, we discuss the integration of all AdvACT arrays with pre-existing ACTPol infrastructure.

Advanced ACTPol (AdvACT)↗

CEPS - A Compact Electron-Proton Spectrometer

Small mass/power sensors are needed for autonomous Moon surface ops that provide alerts to impending adverse space weather conditions. In order to use current operational forecasting tools, a sensor capable of measuring both high-energy electrons and protons is needed. By combining high-TRL Timepix technology with a CdTe layer, this project leverages known technology to fill a critical gap for surface operations. The proposed work will bring ability to provide warnings to crews to shelter with a device that can easily be carried on the Lunar and Martian surfaces.

Radiation↗

The ABCs of phase retrieval: Connecting the acronyms of scanning transmission electron microscopy

High-resolution scanning transmission electron microscopy (S/TEM) is an indispensable tool for characterizing the structure and properties of materials down to the atomic scale. Conventional S/TEM imaging, however, is limited by the phase problem, whereby the phase of the electron exit wave is lost upon detection. Recent advances in diffractive imaging and 4D-STEM have enabled a range of phase-retrieval techniques that computationally reconstruct the missing information encoded in the phase of the transmission function. These approaches offer improved dose efficiency and enhanced sensitivity to weakly scattering signals, extending quantitative imaging to beam-sensitive materials composed of light elements. In this work, we introduce the phase problem in electron microscopy and survey the diverse landscape of phase-retrieval techniques used in the field. Despite their many acronyms and algorithmic variations, these techniques share a common physical and mathematical foundation. We present a unified framework that connects these seemingly distinct methods, from parallax imaging and tilt-corrected bright-field (tcBF-STEM), to aberration-corrected bright-field (acBF-STEM), optimum bright-field (OBF-STEM) and single-sideband (SSB) ptychography, as well as first-moment integrated center of mass techniques (iCOM) and iterative ptychographic algorithms. Based on these insights, we discuss the opportunities and practical limitations of applying these methods across different materials systems, detector designs, and microscope configurations.Graphical abstractRepresentative electron microscopy configurations used for phase retrieval and diffractive imaging in S/TEM: (a) Zernike phase-contrast transmission electron microscopy (TEM), (b) small-convergence-angle four-dimensional scanning transmission electron microscopy (4D-STEM) for nanobeam-based phase reconstruction methods, and (c) large-convergence-angle 4D-STEM for ptychographic and related diffractive imaging techniques reviewed in this work.

36 MATERIALS SCIENCE↗

Developing a GUI for the Robotic Test Stand

The introduction of this poster explains the technology behind DUNE’s far and near detectors and how passing neutrinos generate electrons that drift into a wire grid. I then explain how 3 ASICs manage signals received from electron interception. Next, the poster states how COLDATA chips are undergoing quality control by a Robotic Test Stand using a state machine. I further explained how earlier tests were done via a command line script and the necessity to implement a user-friendly Graphical User Interface with new features a command line can’t implement. For the implementation section, tools and methods for implementation are listed such as Python, tkinter, and GitHub as well as how multithreading and queue implementation was necessary for GUI functionality. Then, I elaborated on the GUIs new features. Finally, I explain how the GUI will be distributed across multiple institutions and future changes planned for the GUI. Photos of the RTS, far detector cave, diagram of anode assembly plane, COLDATA chips, set up tab, result tab, and legacy command line interface are shown.

Gutierrez Villanueva, Jaziel [DuPage Coll.]↗

Role of deep levels and barrier height lowering in current-flow mechanism in 150 μ m thick epitaxial n-type 4H–SiC Schottky barrier radiation detectors

Schottky barrier detectors (SBDs) require larger surface areas than conventional electronics to increase the detection efficiency although such SBDs manifest large diode ideality factors due to inhomogeneous areal distribution of surface barrier height (SBH). Inhomogeneous SBH distributions lead to various current flow mechanisms in SBDs, which need to be identified to optimize detector performance. In this Letter, we identify the current flow mechanism in large area Schottky barrier diodes for radiation detection fabricated on 150 μm thick n-4H–SiC epitaxial layers. The analysis of temperature-dependent forward current–voltage (I–V–T) characteristics of SBDs revealed two linear regions in current–voltage curves up to 450 K, one corresponding to the current flow through a low barrier patch, while the other corresponds to that of average barrier distribution. Applying a SBH distribution model to the reverse I–V–T characteristics, an activation energy of 0.76 eV for the current flow over the Schottky barrier was calculated. Additionally, the activation energy did not directly correspond to any of the defect levels observed from the deep level transient spectroscopy (DLTS). Above 450 K, a Schottky type barrier lowering suggested a current flow through a low barrier patch of ≈ 0.8 eV. The absence of any SBH lowering below 450 K indicated that the current corresponded to a neutrally charged trap level at ≈ 0.6 eV below the conduction band edge, which was consistent with DLTS measurements revealing the presence of an electron trap level Z1/2 at 0.59 eV below the conduction band edge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Ray Detector for 1 to 30 keV

Array of silicon X-ray detecting diodes measures photon energy and provides image of X-ray pattern. Regardless of thickness of new X-ray detector, depletion region extends through it. Impinging X-rays generate electrons in quantities proportional to X-ray energy. X-ray detector is mated to chargecoupled-device array for image generation and processing. Useful in industrial part inspection, pulsed-plasma research and medical application.

Alcorn, G.↗

Further developments of electrographic image detectors

This paper reports the current status of a program to develop far- and middle-ultraviolet-sensitive electrographic detectors. These include large-format, semitransparent-photocathode detectors and opaque-photocathode electrographic Schmidt cameras. Modifications of a previously-demonstrated far-UV large-format detector to make it suitable for possible Shuttle/Spacelab space astronomy investigations have been implemented and tested. Middle-ultraviolet-sensitive large-format and Schmidt electrographic detectors are now in the laboratory development stage. Cesium telluride photocathodes are used to provide sensitivity in the 1700-3100 A spectral range, and techniques for processing these photocathodes are discussed. The preparation and use of polyimide barrier membranes, for protecting the photocathodes from deterioration by film outgassing, are described. A new opaque-photocathode vacuum-ultraviolet-sensitive electrographic detector has been demonstrated, which is based on an oblique-focusing electron optical system similar to that used by Princeton with electron-bombarded CCD arrays. Test results and potential applications of this detector are described.

Carruthers, G. R.↗