Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrode design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Quasi-steady plasma accelerators

Results are reported from a continued study of MPD thrusters operating in the quasi-steady mode and using electrode vapor as the propellant. Testing methods were refined, and performance data is now available for a fairly wide range of thruster geometries. Performance was found to be strongly dependent on thruster geometry, with some designs showing approximately twice the efficiency obtained during the preceding contract period. The radial clearance between electrodes, the attachment point of the arc on the cathode, and the electrical resistance of the electrodes appear to be important design variables.

Ducati, A. C.↗

Final Technical Report: SISGR: The Influence of Electrolyte Structure and Electrode Morphology on the Performance of Ionic-Liquid Based Supercapacitors: A Combined Experimental and Simulation Study

Obtaining fundamental understanding and developing predictive modeling capabilities of electrochemical interfaces can significantly shorten the development cycles of electrical double layer capacitors (EDLCs). A notable improvement in EDLC performance has been achieved due to recent advances in understanding charge storage mechanisms, development of advanced nanostructured electrodes and electrochemically stable electrolytes. The development of new generation of EDLCs is intimately linked to that of nanostructured carbon materials which have large surface area, good adsorption/desorption properties, good electrical conductivity and are relatively inexpensive. To address these scientific challenges the efforts of an interdisciplinary team of modelers and experimentalists were combined to enhance our understanding of molecular level mechanisms controlling the performance of EDLCs comprised of room temperature ionic liquid (RTIL) electrolytes and nanostructured carbon-based electrodes and to utilize these knowledge in the design of a new generation of materials and devices for this energy storage application. Specifically our team efforts included: atomistic molecular dynamics simulations, materials science and electrode/device assembly, and synthesis and characterization of RTIL electrolytes.

25 ENERGY STORAGE↗

Nanostructures for Electrical Energy Storage (NEES) (2020 Final Technical Report)

Nanostructures for Electrical Energy Storage (NEES, www.efrc.umd.edu) was an Energy Frontier Research Center supported by the DOE Office of Science, Basic Energy Sciences, from 8/1/2009 to 7/31/2020. Led by the University of Maryland, NEES enjoyed extensive collaborations with its funded partners, including two DOE Laboratories and six universities. The NEES vision has been to reveal a set of scientific insights and design principles that can underpin a next-generation electrical energy storage approach, building on advances in nanoscale science and technology to achieve simultaneous high power and high energy over extended charge/discharge cycling. The vision is motivated by the recognition that scaling into the nano regime opens the door to new physical phenomena and that the tools enlisted in nanoscale research provide major new opportunities for the synthesis not only of materials at molecular scale but for structures at nano scale and above. NEES has translated this vision into its research program based on two observations. First, while the behavior of ions and electrons in electrolytes and in electrode materials is crucial to electrical energy storage (or more appropriately electrochemical energy storage), it is the transport of ion and electron charge between different structural components of a storage device that ultimately determine its performance. With it well recognized that the choice of electrode materials typically constrain ion transport kinetics as well as maximum ion concentration, the search for better electrode materials has been a primary driver of battery research. At the same time the synthesis of electrodes is typically based on aggregation of particles with varying size, shape, and orientation in the electrode. Together with the presence of additional materials to impart electrical conductivity and cohesion to the composite electrode, change in electrode materials is necessarily accompanied by structural changes at the nano/micro scale that are difficult to categorize and manage. From the beginning, NEES’ vision has been to create and study simpler, highly controlled spatial arrangements of known materials as battery components (electrodes, current collectors, and electrolyte) and to understand how design and structure above the molecular scale determines the energy storage performance available from known materials. Second, advances in nanoscience dramatically expanded the portfolio of synthesis methods, structural motifs, and new phenomena available for research. Some of these gave rapid access to new building blocks at the deep nanoscale (e.g., carbon nanotubes grown by self-assembly, nanoscale arrays formed by electrochemical self-alignment, monolayer films controlled by self-limiting reaction). Such advances served as the enabler for the NEES vision to be pursued experimentally through study of 3D structures created and controlled at the nano, micro, and meso scales. Here, we use meso as in the BES MESO Report, implying not only intermediate or varying length scales, but very much the way behavior is influenced by other factors including aggregation of nanocomponents at different densities and spatial configurations, statistical variations in the aggregates, hierarchical architectures in which they can be assembled, or local 3D configurations that result from the architectures. Over its life cycle, NEES has pursued two overarching goals: (1) to understand the scientific fundamentals of electrochemical storage from the nanoscale to the mesoscale; and (2) to create and learn from innovative, controlled, heterogeneous nanostructures, where such nanostructures can enable the first goal and serve as models for future paradigms in energy storage. Specific goals have included: Synthesize heterogeneous nanostructures comprised of multiple materials arranged in controlled fashion and characterize their behavior; Demonstrate and elucidate design principles for achieving simultaneous high power and high energy; Develop materials processes which enable precision control of thin layers and 3D structures; Investigate the impact of artificial interphases on electrode stability during ion insertion/deinsertion; Create dense arrays of nanostructures to understand how the architecture of these assemblies, along with nanostructure design, influences energy storage behavior at the mesoscale; Identify and understand the consequences of nanoconfinement and local inhomogeneities in 3D mesoscale arrays; Develop and apply computational models to stimulate, guide and interpret experiments.

25 ENERGY STORAGE↗

Final Report for completed IPP Project:"Development of Plasma Ablation for Soft Tissue and Bone Surgery"

ArthroCare is a medical device company that develops, manufactures, and markets an advanced surgical tool, a plasma electro-surgical system for cutting and removing tissue. The hand-held electrical discharge device produces plasma in a biocompatible conductive fluid and tissue to which it is applied during surgery. Its products allow surgeons to operate with increased precision and accuracy, limiting damage to surrounding tissue thereby reducing pain and speeding recovery for the patient. In the past, the design of ArthfoCare's plasma wands has been an empirical undertaking. One goal of this R&D program was to put the phenomena involved on a sound scientific footing, allowing optimization of existing plasma based electro-surgery system technology, and the design and manufacture of new and improved kinds of scalpels, in particular for the surgical cutting of bone. Another important related goal of the program was to develop, through an experimental approach, new plasma wand approaches to the cutting ('shaving') of hard bone tissue. The goals of the CRADA were accomplished - computer models were used to predict important parameters of the plasma discharge and the bone environment, and several different approaches to bone-shaving were developed and demonstrated. The primary goal of the project was to develop and demonstrate an atmospheric-pressure plasma tool that is suitable for surgical use for shaving bone in humans. This goal was accomplished, in fact with several different alternative plasma approaches. High bone ablation speeds were measured. The use of probes ('plasma wand' - the surgical tool) with moving active electrodes was also explored, and there are advantages to this method. Another important feature is that the newly-exposed bone surface have only a very thin necrosis layer; this feature was demonstrated. This CRADA has greatly advanced our understanding of bone removal by atmospheric pressure plasmas in liquid, and puts ArthroCare in a good position to develop the techniques for commercial (surgical) application.

43 PARTICLE ACCELERATORS↗

Final Report DE-FG02-04ER63719

The studies completed under this grant significantly advanced the understanding and design of strategies for in situ uranium bioremediation. Novel strategies identified show promise to make in situ uranium bioremediation technically simpler and less expensive. As detailed, important findings included: (1) Development of an electron donor delivery strategy to prolong the in situ activity of Geobacter species and enhance the removal of uranium from the groundwater; (2) Demonstration that reproducible year-to-year field experiments were possible at the ERSP study site in Rifle, CO, making hypothesis-driven field experimentation possible; (3) Elucidation of the geochemical and microbiological heterogeneities with the subsurface during in situ uranium bioremediation, which must be accounted for to accurately model the bioremediation process; (4) The discovery that most of the U(VI) contamination at the Rifle site is sediment-associated rather than mobile in the groundwater, as previously considered; (5) The finding that unlike soluble U(VI), sediment-associated U(VI) is not microbially reducible; (6) The demonstration that electrodes may be an effective alternative to acetate as an electron donor to promote microbial U(VI) reduction in the subsurface with the added benefit that electrode-promoted microbial U(VI) reduction offers the possibility of removing the immobilized uranium from the subsurface; and (7) The finding that, after extended acetate inputs, U(VI) continues to be removed from groundwater long after the introduction of acetate into the subsurface is terminated and that this appears to be due to adsorption onto biomass. This potentially will make in situ uranium bioremediation much less expensive than previously envisioned.

54 ENVIRONMENTAL SCIENCES↗

Impact of gate geometry on ionic liquid gated ionotronic systems

Ionic liquid electrolytes are gaining widespread application as a gate dielectric used to control ion transport in functional materials. This letter systematically examines the important influence that device geometry in standard “side gate” 3-terminal geometries plays in device performance of a well-known oxygen ion conductor. We show that the most influential component of device design is the ratio between the area of the gate electrode and the active channel, while the spacing between these components and their individual shapes has a negligible contribution. Finally, these findings provide much needed guidance in device design intended for ionotronic gating with ionic liquids.

36 MATERIALS SCIENCE↗

Cathode degradation and erosion in high pressure arc discharges

The various processes which control cathode erosion and degradation were identified and evaluated. A direct current arc discharge was established between electrodes in a pressure-controlled gas flow environment. The cathode holder was designed for easy testing of various cathode materials. The anode was a water cooled copper collector electrode. The arc was powered by a dc power supply with current and voltage regulated cross-over control. Nitrogen and argon were used as propellants and the materials used were two percent thoriated tungsten, barium oxide impregnated porous tungsten, pure tungsten and lanthanum hexaboride. The configurations used were cylindrical solid rods, wire bundles supported by hollow molybdenum tubes, cylindrical hollow tubes, and hollow cathodes of the type used in ion thrusters. The results of the mass loss tests in nitrogen indicated that pure tungsten eroded at a rate more than 10 times faster than the rates of the impregnated tungsten materials. It was found that oxygen impurities of less than 0.5 percent in the nitrogen increased the mass loss rate by a factor of 4 over high purity nitrogen. At power levels less than 1 kW, cathode size and current level did not significantly affect the mass loss rate. The hollow cathode was found to be operable in argon and in nitrogen only at pressures below 400 and 200 torr, respectively.

Hardy, T. L.↗

Cathode degradation and erosion in high pressure arc discharges

The various processes which control cathode erosion and degradation were identified and evaluated. A direct current arc discharge was established between electrodes in a pressure-controlled gas flow environment. The cathode holder was designed for easy testing of various cathode materials. The anode was a water cooled copper collector electrode. The arc was powered by a dc power supply with current and voltage regulated cross-over control. Nitrogen and argon were used as propellants and the materials used were two percent thoriated tungsten, barium oxide impregnated porous tungsten, pure tungsten and lanthanum hexaboride. The configurations used were cylindrical solid rods, wire bundles supported by hollow molybdenum tubes, cylindrical hollow tubes, and hollow cathodes of the type used in ion thrusters. The results of the mass loss tests in nitrogen indicated that pure tungsten eroded at a rate more than 10 times faster than the rates of the impregnated tungsten materials. It was found that oxygen impurities of less than 0.5 percent in the nitrogen increased the mass loss rate by a factor of 4 over high purity nitrogen. At power levels less than 1 kW, cathode size and current level did not significantly affect the mass loss rate. The hollow cathode was found to be operable in argon and in nitrogen only at pressures below 400 and 200 torr, respectively.

Hardy, T. L.↗

Ion Conducting Polymer Interfaces for Lithium Metal Anodes: Impact on the Electrodeposition Kinetics

Electrochemical cells that utilize metals (e.g., lithium, sodium, zinc) as anodes are under intense investigation as they are projected to replace the current lithium-ion batteries to serve as a more energy-dense option for commercial applications. In addition, metal electrodes provide opportunities for fundamental research of different phenomena, such as ion transport and electrochemical kinetics, in the complex environment of reactive metal-electrodeposition. In this work, computationally and experimentally the competing effects related to transport and kinetics during the metal electrodeposition process are examined. Using Brownian dynamics simulations, it is shown that slower deposition kinetics results in a more compact and uniform Li morphology. This finding is experimentally implemented by designing ion-containing polymeric coatings on the electrodes that simultaneously provide pathways for lithium-ion transport, while impeding the charge transfer (Li + + e - → Li) at heterogeneous surfaces. It is further shown that these ionic polymer interfaces can significantly extend the cell-lifetime of a lithium metal battery in both ether-based and carbonate-based electrolytes. Through theoretical and experimental investigations, it is found that a low kinetic to transport rate ratio is a major factor in influencing the Li plating morphology. The plating morphology can be further fine-tuned by increasing ionic conductivity.

36 MATERIALS SCIENCE↗

Plasmonic enhanced ultrafast switch.

Ultrafast electronic switches fabricated from defective material have been used for several decades in order to produce picosecond electrical transients and TeraHertz radiation. Due to the ultrashort recombination time in the photoconductor materials used, these switches are inefficient and are ultimately limited by the amount of optical power that can be applied to the switch before self-destruction. The goal of this work is to create ultrafast (sub-picosecond response) photoconductive switches on GaAs that are enhanced through plasmonic coupling structures. Here, the plasmonic coupler primarily plays the role of being a radiation condenser which will cause carriers to be generated adjacent to metallic electrodes where they can more efficiently be collected.

42 ENGINEERING↗

Investigation of the initial and volume recombination losses in gamma versatile cylindrical ionization chamber VGIC developed for gamma ray dosimetry

A versatile Gamma ionization chambers are used for flow control in systems with gamma nuclear reactors and reprocessing plants in and monitoring atmosphere around these facilities, this in order to protect staff. In the Laboratory Detection and Measures (LDM) Division for Study and Development of Nuclear Instrumentation (DSDNI) of CRNB, we designed, developed and characterized a versatile gamma ionization chamber (VGIC) to study experimentally its characteristics according to the geometry of the electrodes, the volume and pressure of the filler gas for the design of a gamma sealed chamber. The tests were conducted under the IEC (International Electro-technical Commission). In this paper, we present the results obtained in the various nuclear tests for characterization and calibration that we have made on the ionization chamber gamma VGIC prototype developed at our Department. To do this, three irradiators were operated at the Laboratory Calibration (SSDL) of the Department of Medical Physics Nuclear Research Center of Algiers (CRNA). Irradiator intensive gamma ({sup 60}Co: 1.25 MeV), one medium intensity gamma ({sup 137}Cs: 0.662 MeV) and 3rd low intensity ({sup 60}Co). Saturation curves and linearity were identified and the operating range and the sensitivity of the chamber have been deducted. The (I,V) characteristics of the chamber filled, with argon gas at 3 bar (0.3 M pa) pressure, for gamma ray irradiator sources were studied. To do so, the chamber was irradiated with gamma rays using different numbers of gamma sources (i.e. Up to 5). The plateau region is reached above 200 V and the detector operating voltage is found to be 600 V. It is observed that in the plateau region the slope is constant with an increase in the exposure rate. The (1/I, 1/V) and (I, l/V{sup 2}) characteristic curves reveal the presence of the initial and volume recombination losses. The volume recombination losses are found to be smaller than the initial recombination losses. Finally, in order to strengthen our results, we performed in the same conditions, a comparative characterization with another ionization gamma chamber type reference LND 504 (USA). (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wireless Self-Acquistion of 12-Lead ECG via Android Smart Phone

Researchers at NASA s Johnson Space Center and at Orbital Research, Inc. (a NASA SBIR grant recipient) have recently developed a dry-electrode harness that allows for self-acquisition of resting 12-lead ECGs by minimally trained laypersons. When used in conjunction with commercial wireless (e.g., Bluetooth(TM) or 802.11-enabled) 12-lead ECG devices and custom smart phone-based software, the collected 12-lead ECG data can also immediately be forwarded from any geographic location within cellular range to the user s physician(s) of choice. The system can also be used to immediately forward to central receiving stations 12-lead ECG data collected during space flight or during activities in any remote terrestrial location supported by an internet or cellular phone infrastructure. The main novel aspects of the system are first, the dry-electrode 12-lead ECG harness itself, and second, an accompanying Android(TM) smart phone-based wireless 12-lead ECG capability. The ECG harness nominally employs dry electrodes manufactured by Orbital Research, Inc, recently cleared through the Food and Drug Administration (FDA). However, other dry electrodes that are not yet FDA cleared, for example those recently developed by Nanosonic, Inc as part of another NASA SBIR grant, can also be used. The various advantageous features of the harness include: 1) laypersons can be quickly instructed on its correct use, remotely if necessary; 2) all tangled "leadwire spaghetti" is eliminated, as is the common clinical problem of "leadwire reversal"; 3) all adhesives and disposables are also eliminated, the harness being fully reusable; if multiple individuals intend to use use the same harness, then standard antimicrobial wipes can be employed to sterilize the dry electrodes (and harness surface if needed) between users; 5) padded cushions at the lateral sides of the torso function to press the left arm (LA) and right arm (RA) dry electrodes mounted on the cushions against sideward or downward-rested arms of the subject; 6) sufficient distal placement of the arm electrodes achieves good electrode abutment to the arms without the need for adhesives, straps, bands, bracelets, or gloves; 7) padding over the sternum avoids "tenting" in the V1 through V3 (and, when present, the V3R) electrode positions; 8) easy-to-don, one-piece design with an adjustable, front-side single point of connection and an adjustable shoulder strap; and 9) Lund or "modified Lund" placement of the dry electrodes, the results of which more effectively reproduce results from "standard" 12-lead ECG placements than do results from Mason-Likar placements. The main limitation of the harness is that "one size does not fit all", meaning that an appropriately sized harness (small, medium, large, etc) must be chosen on the basis of an individual's size. To facilitate the use of the harness with inexpensive, commodity-grade cell phones and tablet devices, 12-lead ECG software is also being developed to accompany the harness for wireless use with Android. For this part of the project, NASA has teamed with TopCoder, Inc and the Harvard-affiliated NASA Tournament Lab in sponsoring java-based software programming contests through TopCoder. While ECG signals from the harness can already be wirelessly received and thoroughly processed (locally or remotely) by commercial-grade conventional (as well as advanced) 12-lead ECG software running on Microsoft Windows(TM), the Android-based software, once completed, will "cast a wider net" by allowing for a greater percentage of cell phone owners to participate in inexpensive, store-and-forward recordings of 12-lead ECGs worldwide, including for example Android cell phone users in many remote, third-world locations. At the time of writing, the Android 12-lead ECG software platform consists of a basic but expanding graphical user interface and accompanying software that: 1) wirelessly receives the 12-lead ECG data stream from a Bluetooth-based, FDA-cleared 12-leaCG device attached to the harness; 2) locally stores the same data in binary format to the SD card on the Android cell phone; and 3) makes the data stream in available in real time, for now to TopCoder's java programming contestants.

Schlegel, Todd T.↗

A Combined Experimental and Theoretical Study on the Activity and Selectivity of the Electrocatalytic Hydrogenation of Aldehydes

A detailed mechanistic study of the electrochemical hydrogenation of aldehydes is presented toward the goal of identifying how organic molecules in solution behave at the interface with charged surfaces and what is the best manner to convert them. Specifically, this study focuses on designing an electrocatalytic route for ambient temperature post-pyrolysis treatment of bio-oil. Aldehyde reductions are needed to convert biomass into fuels or chemicals. A combined experimental and computational approach is taken toward catalyst design to provide testable hypotheses regarding catalyst composition, activity, and selectivity. Electrochemical hydrogenation mechanisms for benzaldehyde and pentanal reduction are found to proceed by a coupled proton-electron transfer process. Initial results show that Au, Ag, Cu, and C catalysts exhibit the highest conversion to alcohol products. These catalysts are suitable because they show high cathodic onset potentials for H2 formation and low cathodic onset potentials for organic reduction. Conversion of aromatic aldehydes is found to be appreciably higher than aliphatic ones. Classical molecular dynamics simulations of solvent and substrate mixtures in an electrolytic cell were performed to assess how species concentrations vary at the solid/liquid interface and in the bulk as a function of applied voltage. Results show that an increase in voltage in the electrolytic cell decreases organic and increases water mole fractions at the solid/liquid interface. In this current study, charged cathodic surfaces result in carbonyl orientations at the surface that do not favor electron transfer. Repulsion of organic substrates to the bulk must be compensated by strong adhesion to the electrode surface. Implications on catalyst choice and process design are discussed.

Pyrolysis Oil upgrading, Atomistic Simulations, El↗

Mode rotation control in a tokamak with a feedback-driven biased electrode

Rotation of the plasma and MHD modes in tokamaks has been shown to stabilize resistive wall and tearing modes as well as improve confinement through suppression of edge turbulence. In this work, we control mode rotation with a biased electrode inserted into the plasma of the High Beta Tokamak-Extended Pulse’s facility in conjunction with its active GPU (Graphical Processing Unit) feedback system. We first characterize a negative linear relationship between the electrode voltage and mode rotation. Using this relationship, we design, simulate, and implement a proof-of-concept, GPU-based active-control system, which shows consistent success in controlling mode rotation in both feedforward and feedback operation. Controllability is limited by operating conditions, the electrode’s voltage range, and by the electrode’s proximity to the vessel’s walls. The final control system has a 15 μs cycle time, but the addition of various signal filters results in a full cycle latency of 200 μs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synergetic effect in a mixture of noble gases around the Paschen minimum

DC and pulse breakdown in the He-Ar gas mixture are investigated for small pressures and inter-electrode gaps. Expressions for calculating the breakdown voltage of a gas mixture are derived, assuming that breakdown occurs by way of the Townsend breakdown mechanism and that Maxwell spectrum can be used for the free electron gas. The parameters considered in experiments have been chosen so as to be of interest in designing gas-filled surge arresters. The obtained results demonstrate that the derived breakdown voltage expressions are correct, and that a suitable choice of parameters can produce a positive synergetic effect with regard to gas-filled surge arrester design. The latter issue is especially interesting for lowering the dc breakdown voltage of unconditioned electrodes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗