Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

The Fast Modular Reactor (FMR) - Development Plan of a New 50 MWe Gas-cooled Fast Reactor

General Atomics Electromagnetic Systems (GA-EMS) will be developing a new 50-megawatt electric (MWe) fast modular reactor (FMR), under the Department of Energy’s (DOE’s) Advanced Reactor Demonstration Program (ARDP), Advanced Reactor Concepts 2020 (ARC-20) development pathway, that provides safe, carbon free electricity, capable of incremental capacity additions. A modular design allows it to be factory-built and assembled on-site to keep the cost of capital low, while the dry-cooling facilitates siting to complement renewables in nearly any location. GA-EMS is committed to commercialization of the proposed reactor, with a demonstration by 2030, and deployment by the mid-2030s. The ultimate goal of the design is to develop flexible and dispatchable carbon-free power source for the 2035 US electricity market. The GAEMS- led team will verify that simplified characteristics (e.g., inert helium gas coolant, pellet-loaded fuel rod, installation-free of heat sink requirements, small and passive heat removal systems) of the FMR will result in a safe, maintainable, cost-effective, distributed, nuclear energygenerating station. Three key specific project objectives for the next three years include: Development of the conceptual design of the 50- MWe FMR plant, Achievement of Technology Readiness Level (TRL) 4 for key system and component technologies through in-pile tests, out-of-pile tests, and numerical experiments; and Development of robust techno-economic analysis (TEA) and pre-application licensing approach necessary for timely demonstration and eventual commercialization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Frozen Freedom: Unleashing Grocery Store Demand Flexibility: Preprint

Grocery stores consumed approximately 3% of total electricity used by commercial buildings in the U.S. in 2018 (EIA 2018), representing a unique end-use load profile characterized by the critical use of refrigerated display cases. Exploring demand response (DR) scenarios in grocery stores presents an opportunity to enhance the efficiency and sustainability of surrounding communities. In addition, recent studies demonstrate that implementing control algorithms considering demand flexibility strategies can lead to load and peak reductions in standalone refrigerated display cases. Because small business grocery stores operate on thin margins, the energy bill cost savings DR might provide could make a positive difference toward continued operations. Still, uncertainty remains about the extent of demand flexibility potential controls could provide when coupling refrigeration with whole building operation. To enhance economic viability and grid stability, it is essential to quantify the load flexibility capability of grocery stores. Advanced controls can optimize energy consumption by responding to load shedding, shifting, and DR events, as well as daily Time-of-Use (TOU) rates without compromising food safety. Using both quantitative data and interviews with community-based organizations, we developed a full-size store model and two small store models with controlled refrigerated cases, HVAC, and lighting systems based on actual grocery store properties. Through simulations, we have assessed load flexibility strategies with varied DR events. The results highlight potential for energy and peak reduction with advanced or basic controls. However, interviews and data indicate that more support is needed to make DR strategies consistently accessible to small grocery stores.

demand flexibility↗

Biconjugate Impedance Matching Control of the HERO WEC: Preprint

Effective control strategies are essential for maximizing the power output of wave energy converters (WECs). In this study, we explore the methodology of port-based modelling which can be used for bi-conjugate impedance matching, a type of reactive control that involves maximizing power transfer by setting the load (PTO) impedance to be the complex conjugate of the source impedance (WEC). Despite its foundational role in electrical engineering, this method has seen limited application in wave energy and has not yet been demonstrated in wave-powered desalination systems. We represent our complex multidisciplinary system as an equivalent circuit to explore frequency-based relations. The HERO WEC, a small-scale, modular point absorber (PA) designed for reverse osmosis desalination is used as a case study to demonstrate port-based modelling for control applications. Improving the performance of wave-powered water desalination systems could play a critical role in addressing freshwater scarcity for coastal communities, especially those in remote or disaster-prone regions.

16 TIDAL AND WAVE POWER↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulate Wind Loading on RUTE SunTracker: Cooperative Research and Development (Final Report)

RUTE produces and delivers efficient, sustainable structural foundation systems for the wind and solar industries, instrumental in the effort to lower the cost of clean electricity and reduce CO2. RUTE's SunTracker is a high-clearance agrivoltaic solar array. The system uses raised cables, providing support with less materials and cost. These cables can provide tracking for increased energy generation and greater revenue, allowing the land beneath to be used for other means simultaneously. RUTE provided data files that NREL will use to perform computational fluid dynamics (CFD) simulations to characterize and predict wind loading on the 6x6 RUTE SunTracker photovoltaic (PV) array. Varying both the panel orientations and wind speeds provides information on how the array can manage a variety of weather conditions. These results, in turn, inform RUTE's design and construction of these arrays.

14 SOLAR ENERGY↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network - that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest-in the sense of electrical distance - from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for realtime operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

distribution service transformer↗

The value of hydropower flexibility for electricity system decarbonization

Hydropower is an abundant, dispatchable, clean energy resource that will play an important role in supporting the clean energy transition. In particular, dispatchable hydropower can provide the operational flexibility that will be required in future systems with high variable renewable energy penetrations. However, the theoretical operational flexibility of hydropower can be restricted in practice by various non-power constraints. In this paper, we quantify how increasing the operational flexibility of dispatchable hydropower resources with reservoirs impacts least-cost generation portfolios and supports power system decarbonization. Specifically, we conduct a capacity expansion analysis of a two-zone system: a hydro-dominated region and a neighboring region with aggressive decarbonization targets that are represented by the United States Pacific Northwest and California respectively. We then introduce a quantifiable index for characterizing the operational flexibility of reservoir hydropower and assess how changes in this metric impact the system-optimal generation portfolio. We find that increasing hydropower flexibility leads to more investment in wind generation, less investment in natural gas generation, lower system costs, and lower system emissions. We further demonstrate a substitution effect between the grid services provided by flexible hydropower operation, increased transmission capacity on a congested line, and energy storage resources. Finally, we show that increasing the operational flexibility of hydropower increases the effective load carrying capability of both hydropower and wind resources. This research supports a more nuanced understanding of how hydropower can support electricity system decarbonization and may motivate reassessing the cost-benefit tradeoffs of non-power constraints that restrict operational flexibility.

Capacity expansion modeling↗

The Distribution System Operator with Transactive (DSO+T) Study

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. Using a highly interdisciplinary co-simulation and valuation framework, this assessment encompasses the entire electrical delivery system from bulk system generation and transmission, through the distribution system, to the modeling of individual customer buildings and flexible assets (including heating, ventilation, and air conditioning [HVAC] units, water heaters, batteries, and electric vehicles). The study exercises a transactive energy retail market coordination scheme designed to integrate with an existing day-ahead and real-time competitive wholesale electricity market. Software decision-making agents are designed for the retail market operator as well as various price-responsive flexible assets. The engineering and economic performance of the transactive energy scheme is studied for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distribution System Operator with Transactive (DSO+T) Study: Volume 1 (Main Report)

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. Using a highly interdisciplinary co-simulation and valuation framework, this assessment encompasses the entire electrical delivery system from bulk system generation and transmission, through the distribution system, to the modeling of individual customer buildings and flexible assets (including heating, ventilation, and air conditioning [HVAC] units, water heaters, batteries, and electric vehicles). The study exercises a transactive energy retail market coordination scheme designed to integrate with an existing day-ahead and real-time competitive wholesale electricity market. Software decision-making agents are designed for the retail market operator as well as various price-responsive flexible assets. The engineering and economic performance of the transactive energy scheme is studied for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Hanford Lead Canister Collaboration

The Hanford Site, Management of the Cesium and Strontium Capsules (MCSC) Project is preparing to place cesium and strontium material into dry storage using stainless steel canisters that are housed inside vertical concrete casks. Part of the site’s aging management program is to use a spare canister system as a leading indicator canister to provide advance warning for signs of chloride induced stress corrosion cracking (CISCC) or any other kind of canister degradation that might take place over the system’s 300-year design life. The Hanford Lead Canister (HLC) will use electric heaters to simulate the decay heat of cesium and strontium to ensure the HLC simulates the environment and conditions the capsule-loaded systems will experience. In addition to being part of the site’s aging management program, the HLC is being made available for research and development that advances the industry regarding canister mitigation and repair (M&R). The HLC system closely resembles current spent nuclear fuel (SNF) dry storage systems, making the HLC useful for demonstrating technologies or performing research that is relevant to SNF canisters . Several organizations are collaborating to prepare the HLC, along with technical strategy, to perform the needed research and development activities, to include the Pacific Northwest National Laboratory (PNNL), Central Plateau Cleanup Company (CPCCo), and the Electric Power Research Institute (EPRI). In one example of this collaborative research, EPRI is planning to use the HLC to demonstrate in-situ M&R technologies under controlled conditions before the HLC is deployed at Hanford. There is a period of several years when the HLC will be available for canister M&R activity before it is deployed. This paper describes the development of the HLC, its role in the Hanford site’s MCSC Project aging management program, and some of the research activities that are planned for the HLC.

Klymyshyn, Nicholas A.↗

Optimal Siting of EV Fleet Charging Station Considering EV Mobility and Microgrid Formation for Enhanced Grid Resilience

Coordinating infrastructure planning for transportation and the power grid is essential for enhanced reliability and resilience during operation and disaster management. This paper presents a two-stage stochastic model to optimize the location of electric vehicle fleet charging stations (FEVCSs) to enhance the resilience of a distribution network. The first stage of this model deals with the decision to place an FEVCS at the most favorable and optimized location, whereas the second stage aims to minimize the weighted sum of the value of lost load in multiple potential scenarios with different faults. Indeed, the second stage is a joint grid restoration scheme with network reconfiguration and microgrid formation using available distributed generators and fleet electric vehicles. The proposed model is tested on a modified IEEE-33 node distribution network and a four-node transportation network. Case studies demonstrate the effectiveness of the proposed model.

25 ENERGY STORAGE↗

Brick Schema Standardized Plug Load Control Strategies for Load Reduction: Preprint

Plug loads comprise a significant percentage of commercial building energy consumption. Applying intelligent controls to turn off plug loads when unused can provide dynamic load reduction and flexibility, which are key traits of grid-interactive efficient buildings. This capability is important for equitable decarbonization as it can enable disadvantaged communities to electrify buildings without costly upgrades to electrical infrastructure. In this work, we present the effectiveness of various control strategies along with the operational lessons that informed their design. During a three-year period, we operated over 600 smart outlets in 12 university office buildings. The attached plug loads consisted primarily of printers, TVs, water dispensers, and copiers. After recording baseline power measurements for one year, we designed plug load control (PLC) strategies for each plug load type, use, and for different risk tolerance levels because PLC can potentially be disruptive to daily work. We used the Brick Schema to facilitate the management of plug load locations and other metadata. For advanced controls, we integrated the smart plugs with heating, ventilation, and air conditioning (HVAC) systems through the campus building automation system. We found static schedules to be the least disruptive and most predictable for occupants, resulting in 38% and 66% energy savings in two studies. For printers, print server-triggered PLC produced 86% savings, the highest of all strategies with minimal occupant impact. Scheduling of water dispensers and digital signage TVs produced 49% and 70% savings respectively with opportunities to improve performance with the use of HVAC occupancy data.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Real-Time Implementation of Smart Wireless Charging of On-Demand Shuttle Service for Demand Charge Mitigation

This paper presents a smart charge management strategy for an on-demand electric shuttle operating at the National Renewable Energy Laboratory (NREL) campus and supported by an inductive charger at the vehicle's waiting spot. A new control algorithm has been proposed for mitigating the demand charges incurred from the wireless charger. It monitors the shuttle, wireless charger, renewable energy generation, and other loads and regulates charging behavior for demand charge mitigation. Within the control algorithm, an energy prediction is made to estimate the mobility needs of the vehicle and maintain uninterrupted service during operation while still minimizing peak demand. The proposed controller is designed and optimized using a Simulink model for the entire system. It is then implemented and tested in real time at the NREL campus using online cloud services. Two vehicle-use cases' charge-sustaining and charge-depletion operation' are tested under different campus power profiles and drive cycles to assess the controller's performance. In this work, the proposed controller showed a robust performance under different driving scenarios, with high correlation between simulation and experimental data. The results show that proper demand response can be achieved, with an average of 94% reduction of charging loads during peak demand events.

33 ADVANCED PROPULSION SYSTEMS↗

Transient Optimization of the Cryogenic Moderator System Controller at the Spallation Neutron Source for Improved Performance

The high-energy neutron beam generated at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is moderated to use cold (slow) neutrons for scientific discoveries. The Cryogenic Moderator System (CMS) removes heat from the neutron beam using cryogenic hydrogen (H 2 ) moderators connected via heat exchangers to a helium (He) refrigeration loop that dissipates heat using a compressor-brake system. However, the CMS is affected by sporadic losses in beam power, referred to as "beam trips," as these events generate significant disturbances in cooling requirements. To accommodate the heat load transients during beam trips, the CMS uses a decentralized control strategy consisting of four flow valves and one electric heater adjusted by independent proportional-integral (PI) controllers. During the CMS’s initial commissioning, the PI gains were calibrated based only on tracking performance, overlooking their effectiveness in disturbance rejection. A data-driven, control-oriented closed-loop model was developed to recalibrate the PI gains and minimize the transient disturbances caused by beam trips. The model consists of three main components: (1) a physics-based model of the He refrigeration loop, (2) a machine-learning model of the cryogenic H 2 cooling trains, and (3) the control logic used for feedback set-point tracking. Experimental results showed that the recalibrated gains obtained in this study improved the CMS’s transient response during beam trips.

Maldonado Puente, Bryan↗

Enhanced Hanford Low-Activity Waste Glass Property Data Development: Phase 5 and Phase 6

This report summarizes the data collected on two test matrices of low-activity waste (LAW) glass compositions intended to expand the composition-property database: Low-Activity Waste (LAW) Phase 5: Expansion of LAW Glass Composition Boundaries and LAW Phase 6: High PCT and VHT Response Glass Matrix. Both matrix glass compositions were statistically designed to expand the LAW glass composition region. The analyses performed on these glasses include chemical composition (for target compositional verification), density, viscosity, electrical conductivity, crystal fraction, container centerline cooling with crystal identification, the product consistency test (PCT) response, the vapor hydration test (VHT) response, and sulfur solubility. Because of the slightly different scope of the two matrices, not all methods were applied to both matrices. Specifically, the following measurements were taken only on the LAW Phase 5: Expansion of LAW Glass Composition Boundaries glasses: crystal fraction as a function of temperature, density (ρ), viscosity (η), and electrical conductivity (EC, e). Combined, these data contribute a significant amount, 51 glasses, to the database for high LAW loaded enhanced waste glasses. Most of these data are focused near the boundaries of acceptable PCT and VHT responses, where prediction uncertainties are most impactful.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and Test Progress Towards a Supercritical Carbon Dioxide-Based Gas Turbine Waste Heat Recovery System

Supercritical carbon dioxide systems are the focus of significant recent research efforts and promise compact, high-efficiency architecture for gas turbine waste heat recovery for pipeline gas turbines. The waste heat recovery system improves operating efficiency by converting waste heat to additional electric power, which increases overall system efficiency by 35% at the design point, and also significantly improves part-load performance. This paper describes the system design and component selection for a 5.7 MWe waste heat recovery system based on an integrally-geared compressor-expander architecture, including the thermodynamic cycle development, system architecture and component trade studies, and final selection. Validation test results for critical first-of-a-kind compressor and turbine component technologies are also presented, demonstrating full-pressure performance and progress towards commercialization.

wilkes, Jason↗

Flexible FlueCO2

Carbon dioxide (CO2) emission reductions remain a significant challenge on the path to clean energy. There are increasing legislative, social, and environmental factors motivating CO2 emissions reduction from power plants with carbon capture and storage (CCS). CCS in natural gas combined cycle (NGCC) power plants is critical to achieve a net-zero carbon electricity grid. Enhanced 45Q tax credits provide new incentives, but currently available technologies are unable to profitably operate in grids with deep variable renewable penetration which require flexible NGCC operation. Luna Labs has developed the FlueCO2 membrane to enable a profitable NGCC-CCS process. The FlueCO2 membrane couples steam transport across the membrane to CO2 transport in the opposite direction, enabling high capture efficiencies and low energy costs even at low CO2 concentrations. The dual-phase membrane can operate in the range of typical flue gas temperatures and pressures and does not require temperature or pressure cycling. Luna Labs’ FlueCO2 technology enables flexible and profitable operation of NGCC plants with lower capital investment and impact on electricity prices. In this Phase 1 project, Luna Labs utilized experimental testing, modeling, process simulation, and standardized costing methodologies to evaluate the techno-economic value of a 650 MW greenfield NGCC plant with FlueCO2 (NGCC-FlueCO2). Key design requirements for operation were established and plant performance under load-leveling conditions was validated through computational fluid dynamics and process modeling. Luna Labs developed a dynamic modeling tool which modeled plant operational modes across a variety of tax structures and electricity pricing scenarios to project the overall Net Present Value (NPV) of the NGCC-FlueCO2. FlueCO2 minimizes the impact of CCS integration on plant operation by integrating directly into the NGCC heat recovery steam generator (HRSG). By tapping into the plant’s low-pressure (LP) steam, operators can divert LP steam to the greenfield NGCC and/or CCS process in response to dynamic markets. Since FlueCO2 will not significantly affect HRSG (or NGCC) operation, CCS only turns off during peak power demand (>$250/MWh). Under baseload conditions, FlueCO2 lowers the capital (37%), energy (36%) and carbon capture (<$40/tonne) costs and can increase the overall plant lifetime NPV by approximately ~$1B in comparison with NGCC solvent-based capture reference cases (NETL Case 31B). Luna Labs has shared its costing tools with several interested partners and customers, which follows a generalizable approach to costing analysis.

Kelly, Jesse↗

Carbon emission responsive building control: A case study with an all-electric residential community in a cold climate

In the United States, buildings account for 35% of total energy-related carbon dioxide emissions, making them important contributors to decarbonization. Carbon intensities in the power grid are time-varying and can fluctuate significantly within hours, so shifting building loads in response to the carbon intensities can reduce a building’s operational carbon emissions. This paper presents a rule-based carbon responsive control framework that controls the setpoints of thermostatically controlled loads responding to the grid’s carbon emission signals in real time. Based on this framework, four controllers are proposed with different combinations of carbon accounting methods and control rules. To evaluate their performance, we performed simulation studies using models of a 27-home, all-electric, net zero energy residential community located in Basalt, Colorado, United States. The carbon intensity data of four future years from the Cambium data set are adopted to account for the evolving resource mix in the power grid. Various performance metrics, including energy consumption, carbon emission, energy cost, and thermal discomfort, were used to evaluate the performance of the controllers. Sensitivity analysis was also conducted to determine how the control thresholds and intervals affect the controllers’ performance. Simulation results indicate that the carbon responsive controllers can reduce the homes’ annual carbon emissions by 6.0% to 20.5%. However, the energy consumption increased by 0.9% to 6.7%, except in one scenario where it decreased by 2.2%. Compared to the baseline, the change in energy cost was between –2.9% and 3.4%, and thermal discomfort was also maintained within an acceptable range. The little impact on energy cost and thermal discomfort indicates there are no potential roadblocks for customer acceptance when rolling out the controllers in utility programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗